Type : Bid Notification
NUWCDIVNPT Multiple Award Construction Contract (MACC). Please see attached solicitation and attachments for complete requirement details. Please see Amendment 0001 attached.
NUWCDIVNPT Multiple Award Construction Contract (MACC). Please see attached solicitation and attachments for complete requirement details. Please see Amendment 0001 attached.
This construction project includes interior renovation/repairs to NUWCDIVNPT Building 1319 Lobby (originally constructed in 1996). The project includes demolition, flooring replacement, ceiling replacement, lighting, wall construction, and provision of acoustical doors. Onsite contractor supervision will require two (2) qualified individuals serving the roles of superintendent, quality control manager, and site safety and health officer.
Proposals shall be submitted to Ashley.zannikos@navy.mil and leslie.brazil@navy.mil.Solicitation N66604-20-R-8249: This construction requirement is for the renovation of the second floor in a building located at NUWC Division Newport.
Answer #3: Contractor shall coordinate sequencing of work with the building occupants via the NUWCDIVNPT Construction Manager, i.e., the NUWCDIVNPT Code 1022 Contracting Officer’s Representative, to be identified at time of award in Section G of the contract.Question #4: Is there a requirement to perform work off hours?
Answer #3: Contractor shall coordinate sequencing of work with the building occupants via the NUWCDIVNPT Construction Manager, i.e., the NUWCDIVNPT Code 1022 Contracting Officer’s Representative, to be identified at time of award in Section G of the contract.Question #4: Is there a requirement to perform work off hours?
The Naval Undersea Warfare Center Division, Newport (NUWCDIVNPT) has a construction requirement for HVAC upgrades. Please see attached Solicitation (N6660423R0275) and all attachments, for full information and details regarding this requirement.Contractors do not have to be JCP certified to receive the Solicitation, including drawings, specifications, and photos, but they must have an active CAGE Code.
The Naval Undersea Warfare Center Division, Newport (NUWCDIVNPT) has a construction requirement for a replacement emergency generator. Please see attached Solicitation (N6660424Q0314) and all attachments, for full information and details regarding this requirement.Contractors do not have to be JCP certified to receive the Solicitation, including drawings, specifications, and photos, but they must have an active CAGE Code.