The Department of Veterans Affairs intends to negotiate a sole source contract for a 12-month period with Sophion Bioscience Inc., 400 Trade Center Drive, Suite 6900, Woburn MA 01801 for the QChip-384 measurement plates used with the QUBE062 instrument Qube System for the VA West Haven CT Healthcare System located at 950 Campbell Ave, Bldg. 34, West Haven, CT 06516 on an as monthly basis.
A capability that is useful for studying state-dependent drug actions is to implement a dynamic protocol that can adjust and apply conditioning voltage protocols that are a target percentage of a measurement performed on the same cell earlier in the experimental protocol.
Biomechanics Force Plate Measurement System Product Service Code:- NAICS Code:- 334516 - Analytical Laboratory Instrument Manufacturing Primary point of contact:- Robert Cowins robert.cowins@nist.gov Phone Number 3019758335 Secondary point of contact:- Keith Bubar keith.bubar@nist.gov Phone Number 3019758329
BIOMECHANICS FORCE PLATE MEASUREMENT SYSTEM FOR NIST ENGINEERING LABORATORY Solicitation ID/Procurement Identifier: 1333ND20QNB730299 Ultimate Completion Date: Wed Sep 30 17:00:00 GMT 2020
Interested Parties can contact SSG Matthew Morgan - matthew.morgan.43@us.af.mil The solictitation is expected to be posted late August 2019 Force Plate System Overview -System software for the force plate measurement system that integrates 3D Force Plate measurement system with synchronized highspeed HD color video and displays userselected variables and statistical comparisons in realtime. -
The typical measurement times when measuring Alpha on a 96-well plate are 30 seconds / plate with Alpha HTS Option and 68 seconds / plate with Alpha Standard Option. Multiplexing is only possible on the Standard Option. Multiplexing can be performed on the dual detector model in parallel, on the single detector subsequently, resulting in ~2 times slower reading time.
• Plate interface time: less than five (5) seconds for each plate• Measurement rate: <10 seconds per measurement for one (1) electronic microtiter plate or measurement of six (6) electronic microtiter plates• Dimensions: The instrument can be placed inside a 37˚ incubator for real time monitoring of cell toxicity/cytotoxicityOne (1) - RTCA Analyzer with the following specifications:• Output test signal: 22mV ms+/_ (2% +5mVms) @
Record measurements, exclusive of coating, for all tank bottom plates. Provide UT thickness measurement on no less than five locations per plate and at indications from the screening technologies determined to be relevant. Mark relevant indications on tank surfaces in a neat and professional manner adjacent to the indication.
The report(s) must include a record of NDE findings with drawings depicting plate layout and thickness measurement locations. Incorporate engineering analysis, suitability for service analysis pursuant to paragraph SUITABILITY FOR SERVICE, corrosion rate determinations, and remaining service life calculations. Provide separate report for each tank inspected. Specify the due date for the next inspection. 5.2.