AGILENT GAS CHROMATOGRAPH TRIPLE QUADRUPOLE MASS SPECTROMETER INSTRUMENT SYSTEMS WITH TWO OPTION YEARS Solicitation ID/Procurement Identifier: GS07F0564X Ultimate Completion Date: Tue Aug 06 17:00:00 GMT 2024
AGILENT GAS CHROMATOGRAPH TRIPLE QUADRUPOLE MASS SPECTROMETER INSTRUMENT SYSTEMS WITH TWO OPTION YEARS Solicitation ID/Procurement Identifier: GS07F0564X Ultimate Completion Date: Tue Aug 06 17:00:00 GMT 2024
The department needs a sensitive, robust, and reliable triple quadrupole mass spectrometer instrument coupled with an UHPLC instrument for separation and an additional detection capable of detection of non-chromophore containing agrochemical surfactants that also provides near universal quantitation capabilities while being compatible with the UHPLC system and triple quadrupole mass spectrometer instrument.
Decription: Gas Chromatograph-Mass Spectrometer Instrument must include: a triple quadrupole electron ionization detector, a large capacity turbomolecular pump, a NIST Mass Spectral database library of compounds, software capable of setting up methods, carrying out GC-MS experiments, and comparing results to the NIST database, an autosampler unit for 20 to 30 samples with four cleaning solvent containers, an oilless rough pump, an ecology
Also, the open port interface is compatible with direct sampling of microdroplets from custom inkjet printers used for production of NIST standards.BRAND NAME ONLYOnly Advion Expression offers a mass spectrometer instrument that couples directly to the existing NIST owned Advion open port sampling interface and electrospray ionization source with single quadrupole mass analyzer.
The United States Geological Survey, Geology, Geophysics, and Geochemistry Science Center (GGGSC) requires a quadrupole inductively coupled plasma mass spectrometer (ICP-MS). The instrument will be used for laser ablation ICP-MS trace element analyses for a wide variety of applications as part of the mandated research programs of CMERSC and other parts of the USGS.
The instrument has an ionization source capable of handling 0.5uL/min to 200uL/min flow rates.5. The instrument has a mass range (m/z) of 5-2000 Da in triple quadrupole mode.6. The instrument has a mass range (m/z) of 50-2000 Da in linear ion trap mode.7. The instrument has a maximum scan speed of 12,000 Da/sec in triple quadrupole mode and 20,000 Da/sec in linear ion trap mode.8.
• The tribrid mass spectrometer must consist of three functioning mass analyzers: (1) quadrupole mass filter (2) linear ion trap and (3) Orbitrap.