  • Replace IR Detectors (AFFF), Hangar 139, NAS Oceana, Virginia Beach, VA

    Type : Bid Notification

    Due : 05 Jul, 2022 (21 months ago)
    Posted : 22 months ago
    Started : 06 Jun, 2022 (22 months ago)

    REPLACE IR DETECTORS (AFFF) , NAS OCEANA HANGAR 139, VIRGINIA BEACH, VIRGINIA. The Project Site islocated at Naval Air Station Oceana Building 139. This facility is an aircraft corrosion controlhangar along the flight line.

    From: Federal Government (Federal)

  • Replace IR Detectors (AFFF), Hanger 145, NAS Oceana, Virginia Beach, VA

    Type : Bid Notification

    Due : 08 Feb, 2022 (about 2 years ago)
    Posted : about 2 years ago
    Started : 02 Feb, 2022 (about 2 years ago)

    Generally, the scope of work involves demolition of existing Infrared (IR) Detectors and associated components of the AFFF Fire Protection Systems and providing new detectors, control panels and associated components and wiring for a complete and operational AFFF system. Work must include all labor, material, design, testing and oversight for a complete system.MACC GROUP ID: ML-C00057 CONTRACT HOLDERS ONLY

    From: Federal Government (Federal)

  • NOTICE OF INTENT: High-Temperature Flow Through Infrared Detector for High Temperature Size Exclusion Chromatography Instrument

    Type : Bid Notification

    Due : 15 Sep, 2023 (7 months ago)
    Posted : 7 months ago
    Started : 08 Sep, 2023 (7 months ago)

    NIST needs to maintain state-of-the-art capabilities for standards certifications, texting, and polymer separations research, we seek to replace our current IR 4 detector with once capable of 10x greater sensitivity.

    From: Federal Government (Federal)

  • Bid 22-19 FTIR & IR Microscope

    Type : Bid Notification

    Due : 09 Dec, 2021 (about 2 years ago)
    Posted : about 2 years ago
    Started : 08 Nov, 2021 (about 2 years ago)

        The IR microscope detector compartment must be designed for single or optional dual detector  operation (software controlled).  A wide range of MCT detectors must include a stainless‐steel  body design and provide an 18‐hour liquid nitrogen hold time.    The IR microscope must incorporate continuous view of the sample and surrounding medium  through both  the eyepieces and video display even during data collection.   

    From: University of Southern Mississippi (Higher Education)

  • HVAC & Fire Alarm Replacement - Lake Forest Elementary (Drawings)

    Type : Bid Notification

    Due : 17 Nov, 2022 (17 months ago)
    Posted : 18 months ago
    Started : 03 Oct, 2022 (18 months ago)

    CEILING MOUNTED CARBON MONOXIDE DETECTOR. DETECTOR TO BE US2075 LISTED. FIRE ALARM SYSTEM STROBE UNIT ONLY, CEILING MOUNTED FIRE ALARM SYSTEM SPEAKER/STROBE UNIT, CEILING MOUNTED DUCT MOUNTED SMOKE DETECTOR. SMOKE DETECTOR, SAME AS ABOVE, EXCEPT SUPPLIED WITH 120 VOLT AUXILIARY CONTACTS. AREA SMOKE DETECTOR.

    From: Greenville County Schools (School)

  • ELEVATOR PREVENTATIVE MAINTENANCE AND REPAIRS

    Type : Bid Notification

    Due : 03 Apr, 2024 (16 days ago)
    Posted : 1 month ago
    Started : 27 Feb, 2024 (1 month ago)

    Replace defective light bulbs and broken glass rods. P. Test for operation and timing of coded stations. Q. Test bells, horns and chimes for maximum audibility. R. Test annunciators for proper indication. S. Test auxiliary equipment ie. doorholder - fan shut-down etc. T. Clean film/debris from smoke/heat/duct detectors. 1. Sensitivity test non-analogue smoke detectors are to be completed every 2 years. 635-25-22935 FA Page 6 of 9 2.

    From: Indiana (State)

  • PREVENTATIVE MAINTENANCE FOR FIRE SPRINKLER SYSTEM

    Type : Bid Notification

    Due : 03 Apr, 2024 (16 days ago)
    Posted : 28 days ago
    Started : 07 Mar, 2024 (1 month ago)

    Replace defective light bulbs and broken glass rods. P. Test for operation and timing of coded stations. Q. Test bells, horns and chimes for maximum audibility. R. Test annunciators for proper indication. S. Test auxiliary equipment ie. doorholder - fan shut-down etc. T. Clean film/debris from smoke/heat/duct detectors. 1. Sensitivity test non-analogue smoke detectors are to be completed every 2 years. 635-25-22935 FA Page 6 of 9 2.

    From: Indiana (State)