Search results for: water control valve

Refine your Search
Apply several filters to get precise search results
Showing opportunity 1 - 10 of 676
  • Proposal for Prime Consultant Services Required for the Pre-Treatment Isolation Valves and Raw Water Control Valve Flowmeter at the ...

    Type : Bid Notification

    Due : 13 Oct, 2022 (18 months ago)
    Posted : 20 months ago
    Started : 28 Sep, 2022 (19 months ago)

    Bid Classification: Services Bid Type: RFP - Prime Consultant Bid Number: C11-72-22 Bid Name: Proposal for Prime Consultant Services Required for the Pre-Treatment Isolation Valves and Raw Water Control Valve Flowmeter at the Woodward Avenue Water Treatment Plant Bid Status: Open Bid Closing Date: Thu Oct 13, 2022 3:00:59 PM (EDT) Question Deadline: Mon Sep 26, 2022 3:00:00 PM (EDT) Bid Pricing: $56.75 - Download Only Duration in months: 24 Negotiation

    From: Hamilton (City)

  • 2830-- Service to remove and replace chilled water fan coil and chilled water control valve - Bldg. 1 Basement

    Type : Bid Notification

    Due : 21 Jun, 2021 (about 2 years ago)
    Posted : about 2 years ago
    Started : 15 Jun, 2021 (about 2 years ago)

    Contractor shall provide labor and material to install new 0-10 VDC chilled water control valve, connect chilled water valve lines from the isolation valve to the unit, connect drain line, and insulate newly installed line with Armaflex insulation. Contractor shall provide labor to leak check, start and test valve for proper operation. Upon completion contractor will contact COR (Gustavo Flores) to inform him of the completion of service.

    From: Federal Government (Federal)

  • 4420 SPECIAL Hot Water Control Valve - BH

    Type : Award

    Due : 01 Jul, 2022 (22 months ago)
    Posted : 22 months ago
    Started : 16 Jun, 2022 (22 months ago)

    SOW Armstrong 665 Control ValvesPurchase two Armstrong 665 Control Valves with Gasket kits. Deliver to 113 Comanche road Building 46    Attn. Facilities CJ

    From: Federal Government (Federal)

  • IDOC GRAHAM-24RM062 6900 Water control valves-JH

    Type : Bid Notification

    Due : 09 Nov, 2023 (5 months ago)
    Posted : 5 months ago
    Started : 30 Oct, 2023 (6 months ago)

    File 'Graham Water Control Valves B-39774 BOA~1.docx': File 'Graham Water Control Valves B-39774 BOA~1.docx' deleted . 2. File 'Graham Water Control Valves B-39774 BOA~2.docx': File 'Graham Water Control Valves B-39774 BOA~2.docx' added . Item Information Item # 1: ( 670 - 57 ) Accorn REVSP2 Electronic Valve System, Hot & Cold w/Piezo Pushbuttons or approved equivalent.

    From: Illinois (State)

  • Coastal Process Environmental Health Lab, Building System Cumulative Deficiencies

    Type : Bid Notification

    Due : 21 Apr, 2022 (about 2 years ago)
    Posted : about 2 years ago
    Started : 22 Mar, 2022 (about 2 years ago)

    Below is the proposed scope of work for this project: - Install Lightning Protection System at IMS Coker Hall, Coastal Processes, Fisheries Research Lab - Repairs to Electrical Distribution System at IMS Fisheries Research Lab - Replace Air Handling Unit 1, Ductwork, and Terminal Units at IMS Fisheries Research Lab - Repair Air Handling Units 1 and 2, Replace Chilled Water Control Valve and Water Heater at IMS Coastal Process Building

    From: North Carolina University (Higher Education)

  • Purchase of a Tandem Axle Trailer with 700 Gallon Dual Reel Mounted Jet Rodder for the Jefferson Parish Department of Sewerage

    Type : Bid Notification

    Due : 02 May, 2024 (in 4 days)
    Posted : 9 days ago
    Started : 17 Apr, 2024 (10 days ago)

    External lever for diverting the water flow to each hose reel. Flow control valve for further control of reel speed for safety of operator. Single lever water control valve shall regulate direction of water to hose reel or return to tank utilizing a high-pressure valve assembly. The lever shall be mounted externally outside the control panel for ease of maintenance. Water control valves located inside the control panel are unacceptable.

    From: Louisiana (State)

  • Saginaw Primary Care AHU Upgrade - 655-20-505: replace failing equipment and upgrade control components on the existing air handling system that serves t...

    Type : Bid Notification

    Due : 26 Feb, 2021 (about 3 years ago)
    Posted : about 3 years ago
    Started : 10 Feb, 2021 (about 3 years ago)

    The cooling coil is direct expansion (DX) supplied by a Trane 30 ton air cooled condensing unit and the heating coil is supplied from the heating hot water system. The condensing unit, cooling coil, heating coil, return fan, and return air, outside air, and face and bypass dampers have had issues due to age and are needing replacement. Damper actuators and the heating hot water control valve are pneumatic and need upgrading to electronic.

    From: Federal Government (Federal)