Tank, Hot Water Storage

expired opportunity(Expired)
From: Federal Government(Federal)
70Z08522Q30080B00

Basic Details

started - 21 Jun, 2022 (22 months ago)

Start Date

21 Jun, 2022 (22 months ago)
due - 07 Jul, 2022 (21 months ago)

Due Date

07 Jul, 2022 (21 months ago)
Bid Notification

Type

Bid Notification
70Z08522Q30080B00

Identifier

70Z08522Q30080B00
HOMELAND SECURITY, DEPARTMENT OF

Customer / Agency

HOMELAND SECURITY, DEPARTMENT OF (34261)US COAST GUARD (24383)SFLC PROCUREMENT BRANCH 2(00085) (3649)
unlockUnlock the best of InstantMarkets.

Please Sign In to see more out of InstantMarkets such as history, intelligent business alerts and many more.

Don't have an account yet? Create a free account now.

ITEM 1NSN:                          4520-00-533-7830PART NUMBER:        343410EDESCRIPTION:          BOILER HW AUXCage Code:               79230MFG:                         _____________________QUANTITY: 04 AY             UNIT PRICE: ___________       TOTAL: ___________  DESCRIPTIVE SPEC DATA:HEAT DELIVERY RATE IN BTU PER HOUR:   420000.0.IGNITION METHOD:    ELECTRODE.OVERALL HEIGHT:      61.000 INCHES NOMINAL.CURRENT TYPE:         AC/DC.FREQUENCY RATING:            50.0 HERTZ MINIMUM AND 60.0 HERTZ MAXIMUM.OVERALL DIAMETER:             24.000 INCHES NOMINALPRESSURE RATING:              30.0 POUNDS PER SQUARE INCH NOMINALCUBIC MEASURE:                  10.000 CUBIC FEETEND ITEM ID END USE HEATING SYSTEMS:  ONBOARD 157 WLM C.G. VESSELSHEATING SYSTEM DESIGN:   HOT WATER OR STEAMBOILER TYPE:             VERTICAL FIRE TUBEHORSEPOWER RATING:        NOT RATEDFIRING TYPE:             OILOIL BURNER TYPE:                PRESSURE ATOMIZINGOIL FOR WHICH DESIGNED:             2JACKET INCLOSURE
FEATURE INCLUDED:INSULATION TYPE:    FIBROUS GLASSRADIATION CAPACITY IN SQUARE FEET:    NOT RATEDUNPACKAGED UNIT WEIGHT:            885.00 POUNDSELEC VOLTAGE IN VOLTS:      220.0ELEC VOLTAGE IN VOLTS:     115.0PHASE:           SINGLEMATERIAL:     STEELINDIVIDUALLY PACKAGED IN ACCORDANCE WITH MIL-STD-2073-LE METHOD 10, UTILIZING CUSHIONING, BLOCKING AND BRACING INSIDE A TYPE V, STYLE B COVERED CRATE WITH LAG BOLTS CONFORMING TO ASTM D6039.PRESERVATION, PACKING, & MARKING SHALL BE IN ACCORDANCE WITH SPECIFICATIONS:SEE DESCRIPTIVE SPECIFICATION DATA DATED: 06/13/22SEE DESCRIPTIVE SPECIFICATION DATAYOU MUST BE AN AUTHORIZED DISTRIBUTOR OR DEALER OFSELAS HEAT TECHNOLOGY COMPANY LLC. AND PROVIDE WRITTEN DOCUMENTATION FROM SELAS HEAT TECHNOLOGY COMPANY LLCSubstitute parts are NOT acceptable. It is anticipated that a non competitive sole source purchase shall be awarded as result of this synopsis/ solicitation. It is the Governments belief that only SELAS HEAT TECHNOLOGY COMPANY LLC., and/or their authorized distributors can obtain the required technical and engineering data and genuine OEM parts required

COAST GUARD ISLAND, BLDG 50-7  ALAMEDA , CA 94501  USALocation

Place Of Performance : COAST GUARD ISLAND, BLDG 50-7 ALAMEDA , CA 94501 USA

Country : United StatesState : California

You may also like

KHI-FAC: HOT WATER STORAGE TANK REPLACEMENT SDA-URGENT

Due: 29 Apr, 2024 (in 10 days)Agency: STATE, DEPARTMENT OF

Gas Fired Hot Water Boilers: Service Contract

Due: 26 Apr, 2024 (in 7 days)Agency: COMMERCE, DEPARTMENT OF

HOT WATER HEATER TANK

Due: 01 Oct, 2024 (in 5 months)Agency: U.S. COAST GUARD

Please Sign In to see more like these.

Don't have an account yet? Create a free account now.

Classification

naicsCode 333414Heating Equipment (except Warm Air Furnaces) Manufacturing
pscCode 4520Space and Water Heating Equipment