J041--ANNUAL MAINTENANCE ON CHILLERS & COOLING TOWERS

expired opportunity(Expired)
From: Federal Government(Federal)
36C24820Q1094

Basic Details

started - 07 Jul, 2020 (about 3 years ago)

Start Date

07 Jul, 2020 (about 3 years ago)
due - 20 Jul, 2020 (about 3 years ago)

Due Date

20 Jul, 2020 (about 3 years ago)
Bid Notification

Type

Bid Notification
36C24820Q1094

Identifier

36C24820Q1094
VETERANS AFFAIRS, DEPARTMENT OF

Customer / Agency

VETERANS AFFAIRS, DEPARTMENT OF (103257)VETERANS AFFAIRS, DEPARTMENT OF (103257)248-NETWORK CONTRACT OFFICE 8 (36C248) (4776)

Attachments (1)

unlockUnlock the best of InstantMarkets.

Please Sign In to see more out of InstantMarkets such as history, intelligent business alerts and many more.

Don't have an account yet? Create a free account now.

SOURCES SOUGHT SYNOPSIS The Department of Veterans Affairs, Network Contracting Office 8 (NCO 8) is issuing this sources sought synopsis as a means of conducting market research to identify parties having an interest in and the resources to provide HVAC services by factory certified technicians for Trane (Water-Cooled & Air-Cooled) Chillers at the following Orlando VA Healthcare System (VAHCS) facilities: Orlando VA Medical Center (VAMC) located in Orlando, FL; Lake Baldwin VA Medical Center (VAMC) located in Orlando, FL; Lakemont Campus located in Orlando, FL and Viera VA Healthcare Center (VAHCC) located in Viera, FL. Scope: The Contractor shall provide preventive maintenance, repair services, or comprehensive (all-inclusive parts & labor) preventive maintenance & repair services program or equivalent for Trane (Water-Cooled & Air-Cooled) Chillers, in accordance with OEM specifications and recommendations, to preserve and enhance system reliability, improve efficiency, and extend
equipment life. In addition, cooling tower maintenance, eddy current testing, and chiller overhaul services may be performed on an as needed basis. The list of equipment includes: Manufacturer Model # Year placed into Service Description Location Trane CVHF485 2012 Chiller #1 CEP Baldwin VAMC Trane CVHF485 2012 Chiller #2 CEP Baldwin VAMC Trane CVHE045A 2011 Chiller #3 CEP Baldwin VAMC Trane CVHE500 2009 Chiller #4 CEP Baldwin VAMC Trane CGAM 100F 2012 Chiller #5 DOM Baldwin VAMC Trane CVHF485 2009 Chiller #1 Lakemont Campus Trane CVHF485 2009 Chiller #2 Lakemont Campus Marley MD 5018 2017 Cooling Tower #1 Lakemont Campus Marley MD 5018 2017 Cooling Tower #2 Lakemont Campus Trane CVHF1470 2012 Chiller # 1 Orlando VAMC Trane CVHF1470 2012 Chiller # 2 Orlando VAMC Trane CVHF1470 2012 Chiller # 3 Orlando VAMC Trane CVHF1470 2012 Chiller # 4 Orlando VAMC Trane CVHF1470 2012 Chiller # 5 Orlando VAMC EvapTech 1600 Tons 2012 Cooling Tower #1 Orlando VAMC EvapTech 1600 Tons 2012 Cooling Tower #2 Orlando VAMC EvapTech 1600 Tons 2012 Cooling Tower #3 Orlando VAMC EvapTech 1600 Tons 2012 Cooling Tower #4 Orlando VAMC EvapTech 1600 Tons 2012 Cooling Tower #5 Orlando VAMC McQuay AGZ180CHSNN 2015 Chiller #6 Orlando VAMC McQuay AGZ110CHSNN 2015 Chiller #7 Orlando VAMC Trane TBD Planned 2020 Chiller # 1 Viera VAHCC Trane TBD Planned 2020 Chiller # 2 Viera VAHCC Trane TBD Planned 2020 Chiller # 3 Viera VAHCC Marley TBD Planned 2020 Cooling Tower #1 Viera VAHCC Marley TBD Planned 2020 Cooling Tower #2 Viera VAHCC Marley TBD Planned 2020 Cooling Tower #3 Viera VAHCC Trane CGAM120F 2011 (est) Chiller #4 Viera VAHCC Trane (36) Roof Top Units Planned 2020 Roof Top Units Viera VAHCC The results of this market research will contribute to determining the method of procurement. The applicable North American Industry Classification System (NAICS) code assigned to this procurement is 238220 HVAC contractors. The size standard is $16,500,000.00. If your organization has the potential capacity to perform these contract services, please provide the following information: Organization name, address, telephone number, & email. Duns #. Federal Supply Schedule #, if applicable. Socio-Economic Category (SDVOSB, VOSB, WOSB, SB, Other, etc..). Web site address (if applicable). Provide a tailored capability statement addressing: Services and equipment included. Services and equipment excluded. List the number of factory certified CVHE / CVHF Centrifugal Water-Cooled Chiller technicians you employ. List any discount payment terms you may offer (e.g. 1% -10, Net 30). Provide possible warranty information. If subcontracting or teaming is anticipated to deliver technical capability, organizations shall address the administrative and management structure of such arrangements. The government will evaluate market information to ascertain potential market capacity to provide services consistent in scope and scale with those described in this notice and otherwise anticipated. BASED ON THE RESPONSES TO THIS SOURCES SOUGHT NOTICE/MARKET RESEARCH, THIS REQUIREMENT MAY BE SET-ASIDE FOR SMALL BUSINESSES, SOLE SOURCED, OR PROCURED THROUGH FULL AND OPEN COMPETITION. Telephone inquiries will not be accepted or acknowledged, and no feedback or evaluations will be provided to companies regarding their submissions. Submission Instructions: Interested parties who consider themselves qualified to perform the above-listed services are invited to submit a response to this Sources Sought Notice by 11:00 am (EST) on July 20, 2020. All responses under this Sources Sought Notice must be emailed to Kurt.Kramer@va.gov.

various locatations in central Florida. see enclosed document(s)  ,
  32827  USALocation

Place Of Performance : various locatations in central Florida. see enclosed document(s)

Country : United States

You may also like

ANNUAL CHILLER MAINTENANCE FOR IOWA CITY VA

Due: 31 Mar, 2026 (in 23 months)Agency: VETERANS AFFAIRS, DEPARTMENT OF

CENTRAL CHILLER PLANT, CHILLER AND COOLING TOWER MAINTENANCE/INSPECTION AND REPAIRS - IDIQ

Due: 10 Sep, 2025 (in 16 months)Agency: BUREAU OF RECLAMATION

COOLING TOWER MAINTENANCE

Due: 14 Jun, 2025 (in 13 months)Agency: VETERANS AFFAIRS, DEPARTMENT OF

Please Sign In to see more like these.

Don't have an account yet? Create a free account now.

Classification

naicsCode 238220Plumbing, Heating, and Air-Conditioning Contractors
pscCode J041Maintenance, Repair and Rebuilding of Equipment: Refrigeration, Air Conditioning, and Air Circulating Equipment