LYNX Bottle, Cage & Rack Washer

expired opportunity(Expired)
From: Federal Government(Federal)
918923

Basic Details

started - 15 Jun, 2018 (about 5 years ago)

Start Date

15 Jun, 2018 (about 5 years ago)
due - 20 Jun, 2018 (about 5 years ago)

Due Date

20 Jun, 2018 (about 5 years ago)
Bid Notification

Type

Bid Notification
918923

Identifier

918923
Department of Agriculture

Customer / Agency

Department of Agriculture
[object Object]

SetAside

SBA(Total Small Business Set-Aside (FAR 19.5))
unlockUnlock the best of InstantMarkets.

Please Sign In to see more out of InstantMarkets such as history, intelligent business alerts and many more.

Don't have an account yet? Create a free account now.

The U.S. Department of Agriculture, ARS, WBSC, Peoria, IL, intends to award a sole source procurement to LYNX Product Group, 650 Lake Street, Wilson, NY 14172 for LYNX Model 410LX Cage & Rack Washer and LYNX Model 340LX Cage & Bottle Washer.The following equipment will be provided by LYNX Product Group:One (1) LYNX Model 410LX Cage & Rack Washer with the following features and options:A. Compartment: 46˝ wide x 85˝ high x 88˝ longB. Overall Unit: 86˝ wide x 104˝ high x 95˝ longC. Double Door for Pass Through Operation - 1/3 View Glass DoorsD. Stainless Steel Insulated ConstructionE. Pit MountedF. Stainless Steel Recirculating Components and PipingG. Stainless Steel Steam Coil HeatingH. One (1) 10HP Stainless Steel Treatment PumpI. Oscillating Jet SystemJ. Automatic Self Cleaning ScreenK. Temperature GuaranteesL. Incoming Utility GaugesM. Illuminated Wash CompartmentN. Personnel Safety FeaturesO. Color Graphic Touch Screen Micro-Computer Control SystemP. 12 - Programmable Automatic
Multi-Phase Treatment CyclesQ. Automatic DamperR. Reusable/ throw-away Alkaline Detergent Side Tank (non-heated)S. Feeder Bottle Wash SystemT. Barrier Wall Flange - One (1) WallU. Thumb Drive Recording System - USBV. Low Pressure Steam PackageW. Factory Programmed Software Restoration KitX. Modem for On-Line Service DiagnosticsY. Ethernet Computer ConnectionZ. UL Listed Control PanelAA. Reline Pit with Stainless SteelBB. Portable Pit PadsCC. LYNX OPTI-Wash IDD. Removal of Existing Unit & DisposeEE. Connections to HVACFF. Knock-Down ShipmentGG. Freight to the Job SiteHH. Reassembly or Supervision by LYNX TechniciansII. Unload, Uncrate and Set in PlaceJJ. Checkout, Testing & StartupKK. Onsite TrainingLL. Two (2) Year Warranty - Parts & LaborSpecifications for the cage and rack washer are: 1) must be able to fit into the existing pit, 96" L X 92"W X 13"D. The pit must have a stainless steel liner fabricated and installed prior to washer installation. 2) It must have pass through capability with each of the two doors having glass windows for viewing. The hinges on the dirty side door needs to be on the right side and the ones on the clean side, the left. 3) It requires a side tank for storing and reusing alkaline detergent. 4) The services must be on the left hand side. 5) Washing compartment must be at least 46"W X 85"H X 88"L. 6) Loading and unloading ramps must be supplied.One (1) LYNX Model 340LX Cage & Bottle Washer with the following features and options:A. Compartment: 48" wide x 32" high x 48" deepB. Overall Unit: 72" wide x 82" high x 55" deepC. Drop Down Door with Rolling Load PlatformD. Pass Through OperationE. Stainless Steel Insulated ConstructionF. Stainless Steel Recirculating Components and PipingG. Stainless Steel Steam Coil HeatingH. One (1)7½HP Stainless Steel Treatment PumpI. Oscillating Jet SystemJ. Automatic Self Cleaning ScreenK. Temperature GuaranteesL. Incoming Utility GaugesM. Right Services and UtilitiesN. Illuminated Wash CompartmentO. Personnel Safety FeaturesP. Color Graphic Touch Screen Micro-Computer Control SystemQ. 12 - Programmable Automatic Multi-Phase Treatment CyclesR. Automatic DamperS. Barrier Wall Flange - One (1) WallT. Thumb Drive Recording System - USBU. Low Pressure Steam PackageV. LYNX OPTI WashW. Removal of Existing Unit & DisposeX. Connections to HVACY. Factory Programmed Software Restoration KitZ. Modem for On-Line Service DiagnosticsAA. Ethernet Computer ConnectionBB. UL Listed Control PanelCC. Freight to the Job SiteDD. Knocked Down Construction with ReassemblyEE. Unload, Uncrate and Set in PlaceFF. Checkout, Testing & StartupGG. Onsite TrainingHH. Two (2) Year Warranty - Parts & LaborSpecifications for the cage and bottle washer are: 1) Must have pass through capability with two drop down doors, each containing glass for viewing. 2) Services must be on the right side. 3) Washing compartment must be at least 48"W X 32"H X 48"L.Our washroom is in the basement of our animal facility and is accessible only by normal sized doors and elevators. The dimensions are as follows, doorway width is 42", hallway width is 61", elevator width is 48", elevator height is 84", and elevator length is 97".Pursuant to the authority of 41 U.S.C. 253(c)(1) and FAR 6.302-1, Only one responsible source and no other supplies or services will satisfy agency requirements. The equipment will be provided for the USDA-ARS-NPA, GRAND FORKS HUMAN NUTRITION RES. CENTER (GFHNRC), GRAND FORKS, ND, 58203. The Government intends to award a firm fixed price purchase order on or about June 20, 2018. This Notice of Intent is not considered a Request for Quotation (RFQ) nor is it a Request for Proposals (RFP). No solicitation document is available and telephone requests will not be honored. Interested persons may identify their interest and capability to respond to this requirement. A determination by the Government not to compete this proposed contract based on responses to this notice is solely within the discretion of the Government. The Government will consider all responses received by 11:00AM Central Standard Time, June 20, 2018. Information received will be considered solely for determining whether to conduct a competitive procurement. Inquiries will only be accepted via email/mail to the Contracting Officer at the following address:

USDA-ARS-NPAGRAND FORKS HUMAN NUTRITION RES. CENTER(GFHNRC)2420 2nd Ave NorthGRAND FORKS, NDLocation

Place Of Performance : USDA-ARS-NPA GRAND FORKS HUMAN NUTRITION RES. CENTER (GFHNRC) 2420 2nd Ave North

Country : United States

You may also like

PM BOTTLE AND CAGE WASHERS

Due: 14 Oct, 2025 (in 17 months)Agency: VETERANS AFFAIRS, DEPARTMENT OF

LYNX CAGE AND RACK WASHER, TUNNEL WASHER, AND BEDDING DISPENSER.

Due: 30 Apr, 2025 (in 12 months)Agency: VETERANS AFFAIRS, DEPARTMENT OF

Animal Cage Transport Inserts

Due: 09 May, 2024 (in 6 days)Agency: Dept of Bus & Neighbrhood Serv

Please Sign In to see more like these.

Don't have an account yet? Create a free account now.

Classification

NAISC: 333999 GSA CLASS CODE: 65
naicsCode 333999
pscCode 65MEDICAL/DENTAL/VETERINARY EQPT/SUPP