Intent to Sole Source

expired opportunity(Expired)
From: Federal Government(Federal)
W81XWH-22-Q-0993

Basic Details

started - 01 Jul, 2022 (22 months ago)

Start Date

01 Jul, 2022 (22 months ago)
due - 16 Jul, 2022 (21 months ago)

Due Date

16 Jul, 2022 (21 months ago)
Bid Notification

Type

Bid Notification
W81XWH-22-Q-0993

Identifier

W81XWH-22-Q-0993
DEPT OF DEFENSE

Customer / Agency

DEPT OF DEFENSE (710996)DEPT OF THE ARMY (133387)MEDCOM (5566)USAMRAA (1033)
unlockUnlock the best of InstantMarkets.

Please Sign In to see more out of InstantMarkets such as history, intelligent business alerts and many more.

Don't have an account yet? Create a free account now.

INTENT TO SOLE SOURCE:This notice announces the intent by the U.S. Army Medical Research Acquisition Activity (USAMRAA) in support of the U.S. Army Aeromedical Research Laboratory (USAARL) to award a firm-fixed priced, sole source, Indefinite Delivery/Indefinite Quantity (IDIQ) contract to APDM Wearable Technologies, under the authority of 41 USC 1901, as implemented in FAR 13.501(a)(1)(ii), sole source (including brand name) under the authority of simplified procedures for certain commercial items. This requirement is for the delivery of Opal Sensors, Inertial Measurement Units (IMU), and Motion Capture Systems in support of USAARL. The Government intends to issue delivery orders for material supplies against a firm-fixed price contract vehicle with a 5 year ordering period.APDM Wearable Technologies is the sole manufacturer as well as the sole distributor of APDM Opal Sensors, Inertial Measurement Units (IMU), and Motion Capture Systems. There are no authorized licensed resellers
for APDM Wearable Technologies equipment and supplies.Essential requirements are:1. Sensors – all sensors shall have the following capabilities.Body-mounted using strapsShall have the capability to be located on multiple body regions using available straps; including, head, upper torso, lower torso, upper arm, lower arm.Device synchronizationUp to 24 sensors shall be able to synchronize using an internal network system to enable time synchronization across all devices in use.Multiple internal network channels shall be available in order to use multiple systems of sensors recording on different channels at one time.Sensors shall be compatible with a wireless base-station to provide live streaming of data when connected. Shall have a range of at least 30m line of site, or 10m indoor.Sensors shall be able to wirelessly synchronize with no access to a common base station.Device Sampling RateShall be capable of sampling up to 800HzShall be adjustableDevice InstrumentationDevices shall include a minimum of 10 degrees of freedom of measurement, including 3 axes of acceleration, 3 axes of angular rate, 3 axes of heading (magnetometer/compass/etc.), and a minimum of 1 barometer measurement.Accelerometer Specifications:At least +/- 200g per axis3-axisAt least 16 bit resolutionGyroscope Specifications:At least +/- 2000 DPS3-AxisAt least 16 bit resolutionMagnetometer Specifications:At least +/- 8 Gauss3-AxisAt least 12 bit resolutionBarometer Specifications:Shall be able to measure pressure changes resulting in changes in altitude as a function of time.Device Data AvailabilityRaw kinematic data providedProcessed data (e.g., sensor orientation) via sensor fusion shall be provided in both Quaternions and Euler AnglesBatteryAt least 8 hours wireless streamingAt least 12 hours synchronous loggingAt least 16 hours asynchronous loggingStorageAt least 8 Gb internal storage (~450 hours of logged data)Device Weight and DimensionsShall be small and secured as to not interfere with military operations and worn under PPEShall be less than 30 grams including batteryShall be less than 44 x 40 x 14 mm (LxWxH)2. AccessoriesDocking stationsShall hold a minimum of 6 sensors in docked position with ability to add additional sensors through cable output.Shall be compatible with sensors described in item #1Shall plug into a computer and download data from all sensors plugged into the stationWireless Access PointShall be able to connect to up to 24 sensors at one time.Shall be compatible with sensors described in item #1Shall connect to the computer and enable wireless streaming and logging of data from connected sensorsStrapsShall have multiple straps available depending on desired mounting location.  Locations include: head, upper arm, lower arm, hand, upper torso (i.e., sternum), lower torso (i.e., belly), upper leg, lower leg, and foot.Shall be compatible with sensors described in item #1.Shall be elastic and able to accommodate multiple adult sizes through elasticity as well as adjustability with Velcro (or other) attachments. Carry CaseShall be capable of containing at least 5 sensors, associated straps, charging docking station, and wireless access point.Associated cables: all power and data transfer cables to charge and operate the system and sensors3. SoftwarePost-processing software:Shall automatically produce joint angle estimates and spatiotemporal gait and balance outcomes for several built in functional tests.Shall provide instructions for precise body placement of the sensor, sensor alignment pose, and calibration pose necessary to be able to produce joint angles over time during any activity.Pre-processing and sensor setup software:Shall provide access to raw and processed IMU dataShall provide processed IMU data include sensor orientations, synchronized time among all sensors, scaled, and calibrated accelerometer, angular rate, magnetometer, and barometer data.4. Packages5-Sensor plus Post-processing Software Package which includes: 7 Opal sensors (as described above), 2 small straps, 2 medium straps, a sternum strap, a lumbar strap, carry case, access point, docking station, controller, and Post-processing software.5-Sensor plus Pre-processing and sensor setup Software Package which includes: 7 Opal sensors (as described above), 2 small straps, 2 medium straps, a sternum strap, a lumbar strap, carry case, access point, docking station, controller, and Pre-processing and sensor setup software.The North American Industry Classification System (NAICS) for this requirement is 334510 – Electromedical and Electrotherapeutic Apparatus Manufacturing and PSC 5963 - Electronic Modules.This announcement fulfills the synopsis requirements under FAR 5.203(a). This Special Notice of Intent is not a request for competitive quotes and no solicitation document exists for this requirement; however, if a vendor challenges the basis for this requirement, please submit a capability statement that includes sufficient detail and with convincing evidence that clearly demonstrates the capability to provide the above mentioned equipment. A determination by the Government not to compete this proposed contract based upon responses to this notice is solely within the discretion of the Government.  A request for documentation or additional information or submissions that only ask questions will not be considered as an affirmative response.  A determination by the Government not to compete based on responses to this notice is solely within the discretion of the Government. Information received in response to this notice will be considered solely for the purpose of determining whether a competitive procurement or a sole source procurement is in the best interest of the Government.All questions and responses concerning this notice shall be emailed to Jeff Flook, jeffrey.l.flook.civ@mail.mil.Capability statements are due, in writing, to the email address listed above no later than 10:00 AM EST, 16 July 2022. Capability statements shall be submitted via email ONLY as Microsoft Word or Adobe PDF attachment. No phone calls will be accepted.

,
  21702  USALocation

Place Of Performance : N/A

Country : United StatesState : MarylandCity : Frederick

You may also like

Notice of Intent to Sole Source

Due: 06 May, 2024 (in 1 day)Agency: EPA

Intent to sole source

Due: 06 May, 2024 (in 2 days)Agency: JUSTICE, DEPARTMENT OF

NOTICE OF INTENT TO SOLE SOURCE TO ASSOCIATED ENVIRONMENTAL SYSTEMS

Due: 06 Sep, 2024 (in 4 months)Agency: DEPT OF DEFENSE

Please Sign In to see more like these.

Don't have an account yet? Create a free account now.

Classification

naicsCode 334510Electromedical and Electrotherapeutic Apparatus Manufacturing
pscCode 5963Electronic Modules