Metal Tank (Heavy Gauge) Manufacturing

expired opportunity(Expired)
From: Sandia National Laboratories(Federal)
2869

Basic Details

started - 04 Jun, 2023 (10 months ago)

Start Date

04 Jun, 2023 (10 months ago)
due - 26 Jun, 2023 (10 months ago)

Due Date

26 Jun, 2023 (10 months ago)
Bid Notification

Type

Bid Notification
2869

Identifier

2869
Sandia National Laboratories

Customer / Agency

Sandia National Laboratories
unlockUnlock the best of InstantMarkets.

Please Sign In to see more out of InstantMarkets such as history, intelligent business alerts and many more.

Don't have an account yet? Create a free account now.

Id2869Posting TypeSources SoughtPosting Published04-Jun-2023Posting Close26-Jun-2023 11:32Current Time (Albuquerque NM)26-Jun-2023 01:41Estimated RFQ Open26-Jun-2023Estimated Award01-Aug-2023NAICS332420: Metal Tank (Heavy Gauge) ManufacturingBusiness Size Standard750 employeesEstimated Period of PerformanceBefore September 2024Competition TypeSet-Aside - Small BusinessTitleHydrogen Storage SystemGeneral InformationThis section displays displays general information about this opportunity.# function _tableSortSubmit(formName,validate,sortEvent,table,val,stat,ptgt,parent) {if( ((typeof TUfromDragEvent != 'undefined') && TUfromDragEvent) || ((typeof TUhideEvt != 'undefined') && TUhideEvt) ) {TUfromDragEvent = false ; TUhideEvt = false;return;}if(parent!=null && parent.tagName =='TH' && parent.getAttribute('sortvalue') != null) { val = parent.getAttribute('sortvalue'); } var submitFunc = (ptgt == (void 0)) ? submitForm :
_submitPartialChange;submitFunc(formName,validate,{event:sortEvent,source:table,value:val,state:stat,partialTargets:ptgt });}TitleGeneral Information10Sources SoughtIf a Request for Quotation (RFQ) results from this posting and the supplier meets the specified requirements, the supplier may be provided an RFQ at a later date.20Buy American CertificationThe Buy American Act may be applicable. If a Request for Quotation (RFQ) is issued, all offerors shall be required to supply a Buy American Certification. Failure to provide the required information may render a proposal non-responsive.30 SUBCONTRACT AWARD BASIS - OPTIONS - 980F11 (05-17)Offeror shall quote its most favorable price and terms, since any subcontract resulting from this Request for Quotation (RFQ) may be awarded on the basis of initial offers. NTESS has limited funds for the completion of this project. Award is anticipated to be made to the responsible Offeror who meets NTESS' requirements and offers the lowest net cost to NTESS for the base requirement, or the base requirement plus those additive alternates or options, selected in consecutive order, the total of which falls within the available funds. Low net cost includes price, transportation charges, and payment discount terms. In order to maximize its expenditure of Government (taxpayer) funding, NTESS reserves the right to accept, reject, or negotiate any or all terms of the Offeror’s proposal. 40Sandia Registration RequiredThis is a Sources Sought / capabilities request. Do not submit a proposal in response to this request. Offerors shall be registered in the NTESS (Sandia) supplier database (iSupplier) to be eligible for award under this opportunity. Registration instructions may be found at http://www.sandia.gov/working_with_sandia/prospective_suppliers/supplier_registration.html 50Background InformationSandia National Laboratories (SNL) Albuquerque campus currently uses bulk hydrogen in several of its research and development facilities. SNL's increased demand and projected future demand for Hydrogen, and a desire to have onsite contingency storage, a bulk liquid storage tank and vaporization skid. The piping served by the two existing gaseous skids will be interconnected to be supplied by one new bulk liquid storage and vaporization location. The proposed location of the new bulk liquid storage is at the east location where gaseous tubes currently reside. This location is approximately 33' wide by 46'6" long. There is 9' high chain-link fencing on the north and west boundaries, and 15'8" tall, 18" thick blast walls on the east and south boundaries.function _richTblRefresh(formName,validate,ptgt,table,event,val) { return _submitPartialChange(formName,validate,{event:event,source:table,partialTargets:ptgt,value:val}); }function _tableRefresh(formName, tablerefresh, src, vld, val, sze, partialTargets){var i = val.indexOf(',');if (i >= 0){sze = val.substring(i+1);val = val.substring(0, i);}var submitFunc = (partialTargets == (void 0)) ? submitForm : _submitPartialChange;return submitFunc(formName,vld,{event:tablerefresh,source:src,value:val,size:sze,partialTargets:partialTargets});}Mandatory RequirementsThis section displays mandatory requirements associated with this opportunity. If you create a response, you must address each.#TitleMandatory Requirement10BUY AMERICAN CERTIFICATE - 980D19 (11-21)“Domestic end product” means—(1) An unmanufactured end product mined or produced in the United States; (2) An end product manufactured in the United States, if—(i) The cost of its components mined, produced, or manufactured in the United States exceeds 55 percent of the cost of all its components. Components of foreign origin of the same class or kind as those that the agency determines are not mined, produced, or manufactured in sufficient and reasonably available commercial quantities of a satisfactory quality are treated as domestic. Scrap generated, collected, and prepared for processing in the United States is considered domestic; or(ii) The end product is a COTS item.Note: "Assembly" may be considered "manufacturing", provided the assembly operations undertaken in the US make the item suitable for its intended use by NTESS and establish its identity. Operations performed after the item has been completed (e.g., packaging, testing) or to add a single component (e.g., one circuit) would not qualify as manufacturing. Certification(a) The offeror certifies that each end product with an anticipated value exceeding $10,000, except those listed in paragraph (b) of this provision, is a domestic end product and that for other than COTS items, the offeror has considered components of unknown origin to have been mined, produced, or manufactured outside the United States. The offeror shall list as foreign end products those end products manufactured in the United States that do not qualify as domestic end products, i.e., an end product that is not a COTS item and does not meet the component test in paragraph (2) of the definition of “domestic end product.” The terms “commercially available off-the-shelf (COTS) item,” “component,” “domestic end product,” “end product,” “foreign end product,” and “United States” are defined in FAR 52.225-1 Buy American—Supplies.Note: For purposes of valuation against the $10,000 threshold, NTESS considers the purchase of multiples of a single item (e.g., twenty N95 masks) and bulk purchases (e.g., 1000-pc reel of capacitors) an individual item.(b) Foreign End Products (enter N/A below, if no foreign end products will be provided):Line Item No. Country of Origin_________________________ ___________________________________________ ___________________________________________ ___________________________________________ ___________________________________________ _________________________________________20Statement of Work Item 1: Vertical Lliquid Hydrogen Storage TankDescription:Vertical liquid hydrogen storage tank, minimum size 4500 gallons ¿ maximum size 6000 gallons including all required manifolds, valves, pressure building/regulating systems, level gauges, pressure gauges, vent stacks, required safety devices to include tank pressure safeties, piping pressure safeties, manual shutoff valves, emergency shutoff valves. Tank shall be designed to operate at a supply pressure of 150 psig.Bulk liquid fill connection with required purge and vent connections and stack.Vaporizers/superheaters capable of providing gaseous hydrogen at a peak flow rate of 15 scfm, average flow rate of 6 scfm.All piping between tank liquid supply and vaporizers/superheaters.Provide System Drawings/Layout.Pertinent system operation and safety information.System startup support. 30Tank RequirementsTank and all components shall comply with all applicable codes and standards including but not limited to ASME, CGA, NFPA2, and NFPA55. All questions need to be submitted by no later than 6/13/23 to a require a response in time before the BOW closes.

1515 Eubank Blvd SE, Albuquerque, NM 87123, United StatesLocation

Address: 1515 Eubank Blvd SE, Albuquerque, NM 87123, United States

Country : United StatesState : New Mexico

You may also like

Operation of a marine and sheet metal shop [Lease / RP23-04]

Due: 21 Apr, 2044 (in about 20 years)Agency: Harbor (Port of LA, POLA)

COI Elens & Maichin Roofing & Sheet Metal, Inc.

Due: 01 May, 2024 (in 3 days)Agency: School District U-46

FABRICATION OF STAMPED SHEET METAL VOXEL

Due: 12 Jul, 2024 (in 2 months)Agency: NATIONAL AERONAUTICS AND SPACE ADMINISTRATION

Please Sign In to see more like these.

Don't have an account yet? Create a free account now.