65--Rem B Power System

expired opportunity(Expired)
From: Federal Government(Federal)
VA25017Q0418

Basic Details

started - 11 May, 2017 (about 7 years ago)

Start Date

11 May, 2017 (about 7 years ago)
due - 18 May, 2017 (about 7 years ago)

Due Date

18 May, 2017 (about 7 years ago)
Bid Notification

Type

Bid Notification
VA25017Q0418

Identifier

VA25017Q0418
Department of Veterans Affairs

Customer / Agency

Department of Veterans Affairs
unlockUnlock the best of InstantMarkets.

Please Sign In to see more out of InstantMarkets such as history, intelligent business alerts and many more.

Don't have an account yet? Create a free account now.

This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; proposals are being requested and a written solicitation will not be issued. The solicitation number is VA250-17-Q-0418 and is issued as a request for quotation (RFQ) in accordance with FAR Parts 12 and 13. The solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular 2005-95. The associated NAICS code is 339112 Surgical and Medical Instrument Manufacturing and small business size standard is 1,000 employees. This is a total service disabled veteran owned small business set-aside. The requirement is for the REM B Power System and accessories. The Rem B Power System will be delivered to the Louis Stokes VA Medical, 10701 East Boulevard, Cleveland OH 44106; this will also be the FOB
destination.This announcement constitutes the only solicitation; a formal, written solicitation will not be issued. PAPER COPIES OF THIS SOLICITATION WILL NOT BE AVAILABLE. This solicitation documents and incorporates provisions and clauses in effect through FAC 2005-95. It is the responsibility of the contractor to be familiar with the applicable clauses and provisions. The clauses may be accessed in full text at these addresses: https://www.acquisition.gov/Far/. The selected Offeror shall comply with the following commercial item terms and conditions, which are incorporated herein by reference: FAR 52.212-1, Instructions to Offerors -Commercial Items, FAR 52.212-3, Offeror Representations and Certifications-Commercial Items - the selected offeror shall submit a completed copy of the listed representations and certifications or confirm that the annual representations and certifications was completed electronically via the SAM website accessed through http://www.acquisition.gov; FAR 52.212-4, Contract Terms and Conditions-Commercial Items; 52.203-17, 52.203-99, and 52.204-4. FAR 52.212-5, Contract Terms and Conditions Required To Implement Statutes or Executive Orders-Commercial Items, paragraph (a) and the following clauses in paragraph (b): 52.203-6, 52.204-10, 52.209-6, 52.219-6, 52.219-8, 52.219-14, 52.219-27, 52.222-3, 52.222-19, 52.222-21, 52.222-26, 52.222-35, 52.222-36, 52.222-37, 52.222-40, 52.222-50, 52.223-18, 52.225-1, 52.225-13, and 52.232-33. The full text of the referenced FAR clauses may be accessed electronically at https://www.acquisition.gov/far/.Evaluation: will be made using the procedures under FAR 13. Offers will be evaluate using the Lowest price technically Acceptable (LPTA). The following VAAR Clauses apply852.203-70 Commercial Advertising 852.211-70 Service Data Manuals852.219-10 VA Notice of total service-disabled veteran-owned small business set-aside.852.232-72 Electronic submission of payment requests 852.246-70 Guarantee (at least one year)852.246-71 InspectionThe Following VAAR Provisions apply852.211-72 Technical Industry StandardsQuotes are to be emailed to Percy Johnson at percy.johnson2@va.gov, no later than 18 May 2017 3:00 p.m. EST.Contract Title: REM B POWER SYSTEMScope: The Cleveland VAMC Surgical Service is requesting to purchase RemB Power System to be utilized in the Operating RoomSpecific Task/Deliverables6400-015-000RemB Electric Micro Drill5100-015-250MicroDrill Series Straight Attachment5100-015-270MD Series Long Straight Attachment6400-031-000RemB Electric Oscillating Saw6400-034-000RemB Electric Sagittal Saw6400-037-000RemB Electric Reciprocating Saw6400-099-000RemB Universal Drive4100-062-000Wire Collet (07 - 1.8mm)4100-125-000Pin Collet (2.0 - 3.2mm)4100-131-0001/4" Drill with Key4100-132-0005/32" Drill with Key4100-110-000AO Small Drill4100-231-000Reamer5100-004-000TPS Cord6400-009-000RemB Electric Hand Switch6400-277-000Sterile Case7205-000-000System 7 Dual Trigger Rotary Handpiece7206-000-000System 7 Reciprocating Saw7208-000-000System 7 Sagittal Saw7203-026-000System 7 Dual Trigger Wire Collet7203-126-000Pin Collet (2.0 - 3.2mm)6203-131-0001/4" Keyed Chuck6203-113-000Hudson Attachment6203-135-000Hudson/Modified Trinkle Attachment6203-150-000Modified Trinkle6203-110-000AO Small Attachment7102-454-000System 7 3HP Insert Tray and Case7215-000-000Stryker SmartLife Battery Pack, LargeRemB DriverFully cannulated handpieceOscillating featureAccepts the same chucks as Cordless Driver II (color coded)Attachments available for drilling, reaming, wire and pin collets, sagittal saw attachment, high-speed bur and radiolucent driverRemB SawsLightweight Titanium designReciprocating Saw - easy, intuitive insertion/removal of blades without toolsSagittal Saw - rotating, indexing head for maximum blade positions, special mount facilitates larger bladeRemB Micro DrillLightweight Titanium designHigh speed, pencil grip drill used to bur, drill and shape bone in a variety of small bone proceduresStraight and angle MD Series attachmentsAccepts j-notch or straight shank bursSystem 7Sagittal saw is significantly quieter than previous generationsStryker SmartLiFE Li-Ion batteries with exclusive ACP Technology provide a longer, more reliable battery life (small battery runs 220% longer, large battery run 183% longer), increasing efficiency in the O.R.An innovative rotary handpiece offering substantially increased torque, providing optimum performance with an improved power-to-weight ratio (29% reduction in overall system weight)Sealed sterilization containers minimize processing time and reduce the use of blue wrap creating a more sustainable solutionDesign enhancements make it lighter, more powerful and easier to useWe require REM B Handpieces as a Name Brand only, since they are the only units that can plug into our existing Stryker CORE2 electronic drill consoles. We currently have one console in each operating room and they are utilized by numerous services within the Operating Room and Ambulatory Surgery.Performance Monitoring: The COR will work with the warehouse staff and biomedical engineering to ensure delivery and incoming inspection to determine for fitness for use. Security Requirements: The contractor will not have access to VA sensitive information. Government-Furnished Equipment or Special Considerations: Not ApplicableOther Pertinent Information or Special Considerations:NoneRisk Control: The Surgical Service will follow any safety recommendations given by the vendor for the equipment.Place of Performance: Cleveland VAMC 10701 East BlvdCleveland, OH 44106 Delivery Schedule:Details of delivery to be finalized by Cleveland VAMC and vendor after contract have been awarded.Period of Performance:One time purchase Contact Information: Percy Johnsonpercy.johnson2@va.gov614 257 5534Contract Specialist Office Address :Department of Veterans Affairs;Columbus;Chalmers P. Wylie Ambulatory Care Center;420 North James Road;Columbus OH 43219-1834 Location: Department of Veterans Affairs Outpatient Clinic Set Aside: Service-Disabled Veteran-Owned Small Business

Department of Veterans Affairs;Louis Stokes VA Medical Center;10706 East Boulevard;Cleveland OHLocation

Address: Department of Veterans Affairs;Louis Stokes VA Medical Center;10706 East Boulevard;Cleveland OH

Country : United StatesState : Ohio

Classification