Kearney Regional Airport Terminal Expansion - Addendum No. 1

expired opportunity(Expired)
From: Kearney(City)

Basic Details

started - 11 Apr, 2022 (about 2 years ago)

Start Date

11 Apr, 2022 (about 2 years ago)
due - 26 Apr, 2022 (about 2 years ago)

Due Date

26 Apr, 2022 (about 2 years ago)
Bid Notification

Type

Bid Notification

Identifier

N/A
City of Kearney

Customer / Agency

City of Kearney
unlockUnlock the best of InstantMarkets.

Please Sign In to see more out of InstantMarkets such as history, intelligent business alerts and many more.

Don't have an account yet? Create a free account now.

Page 1 of 5 ADDENDUM NO. 1 TO TERMINAL EXPANSION AIP 3-31-0045-036 (CARES) At KEARNEY REGIONAL AIRPORT (EAR) KEARNEY, NE Addendum Date: April 19, 2022 To Prospective Bidders: The contract documents/specifications and plans for the above referenced project are hereby amended as follows: Specifications: Entry 1: Replace the Table of Contents (pages ‘v.’ through ‘x.’) with the attached revised Table of Contents (Attachment No. 1) The updated Table of Contents eliminates some architectural specifications that were not included in the final 100% Issued For Bid Specifications. The updated Table of Contents also includes the following architectural specifications that were included in the 100% Issued For Bid Specifications. DIVISION 12 FURNISHINGS: 12 2413 Roller Window Shades ADDED DIVISION 14 CONVEYING SYSTEMS 14 5400 Baggage Handling Systems ADDED Entry 2: Any and all references to the “No Later Than (NLT)” date of October 1, 2023 for project completion (Contract Time) in the contract
specifications are hereby eliminated. The other calendar day allowances per phase still remain in effect. Entry 3: Replace Davis Bacon Wage Rates, “NE20220066 02/25/2022” with the attached Davis Bacon Wage Rates. “General Decision Number: NE20220066 03/18/2022” to be used for building construction (Attachment No. 2). As of April 18, 2022, the Davis Bacon Wage Rate “General Decision Number: NE20220047 02/25/2022” (Construction Type: Heavy) is still current. Entry 4: In Article 5, replace specification section B-101 Airport Safety Measures, Paragraph 101- 2.1 (d) with the following. d. Furnish, place, maintain, move, and remove jersey barriers with chain link fence as required by the CSPP. Entry 5: In Article 5, replace specification section B-101 Airport Safety Measures, Paragraph 101- 5.1 Basis of Payment with the following. 101-5.1 Airport Safety Measures Payment for all airport safety measures costs will be made at the contract lump sum price for "Airport Safety Measures”. This price shall be full compensation for furnishing all labor, equipment, tools, materials, and incidentals necessary to complete all items listed in Section 101-2.1 above. Based upon the contract lump sum price for “Airport Safety Measures", partial payments for "Airport Safety Measures" will be allowed as follows: Page 2 of 5 a. With placement of airport safety measures for Phase 1A: 40% b. With removal of airport safety measures for Phase 1A and placement of safety measures for Phase 1B: 25% c. With removal of airport safety measures for Phase 1B and placement of safety measures for Phases 2 and 2A: 25% d. With removal of airport safety measures: 10% Entry 6: In Article 5, under specification section B-102 Construction Staking, Paragraph 102-2.1 (a), eliminate the following sentence. Ditches Liners: Construction stakes and/or blue tops along ditch flowlines (25-foot intervals) and at critical ditch locations specified on the plans. Entry 7: In Article 5, under specification section B-102 Construction Staking, Paragraph 102-2.1 (e), replace the entire paragraph with the following. e. Storm Drain, Water Main and Sanitary Sewer Pipe: Cut/Alignment stake/hub placed at 25-foot intervals and at pipe inverts and/or fittings. Entry 8: In Article 5, replace specification section B-102 Construction Staking, Paragraph 102-2.2 with the following. 102-2.2 Contractor Provided Construction Control Monuments. The Contractor will provide the following control monuments: • Two (2) horizontal and vertical control monuments for pavement and building construction. Two (2) additional horizontal and vertical control monuments may be required for construction of the Airside Inlet at Sta 1+00.00 if requested by the RPR. Entry 9: In Article 6, regarding City of Kearney Standard Specifications for Municipal Construction, Section 11 Concrete Curb, Curb and Gutters, Concrete Surfacing, Sidewalks, Driveways, and Bikeways, Paragraph 11-30 (A) Preparation of Subgrade, the City’s Testing Firm (Benesch) will perform density tests to verify acceptable moisture and compaction. The Contractor shall not include costs for these tests in their bid. Entry 10: Specification Section 07 5423 TPO Roofing (Induction Weld) At paragraph 2.1, subject to compliance with the specifications, add the following as an approved manufacturer: GAF www.gaf.com Entry 11: Specification Section 08 4233 Revolving Door Entrances At paragraph 2.1, subject to compliance with the specifications, add the following as an approved manufacturer: Duotour Automatic Revolving Door www.boonedam.us Entry 12: Specification section 230523 – VALVES FOR HVAC At paragraph 2.1, subject to compliance with the specifications, add the following as an approved manufacturer: Check Valves: Wheatley Entry 13: Specification section 232113 – HYDRONIC PIPING At paragraph 2.1.A.5 Automatic Flow-Control Valves, subject to compliance with the specifications, add the following as an approved manufacturer: Automatic Flow-Control Valves: NuTech http://www.gaf.com/ http://www.boonedam.us/ Page 3 of 5 Entry 14: Specification section 232113 – HYDRONIC PIPING Add specifications for chilled water buffer tanks to the project manual. Add Subsection 2.1.A.10 as follows: 10. Chilled/Heating Water Buffer Tanks: a. Amtrol, Inc. b. Cemline c. Wheeler d. Wessels e. American Wheatley Add Subsection 2.6.H. as follows: H. Chilled/Heating Water Buffer Tank: Buffer tank shall be ASME Code constructed and stamped in accordance with Section VIII of the ASME Code. Tank shall be registered with the National Board of Boiler and Pressure Vessel Inspectors and a certificate of shop inspection shall be furnished. ASME working pressure shall be 125 psi. Material of construction shall be Carbon Steel. Tank shall be furnished with flanged ends for piping connections NPS 2-1/2 and larger, threaded connections for NPS 2 and smaller, an air vent, R-13 (minimum) spray foam or flexible, elastomeric thermal insulation, and an internal baffle to divert water flow. Entry 15: Specification section 233113 – METAL DUCTS AND ACCESSORIES At paragraph 2.1.A Manufacturers, subject to compliance with the specifications, add the following as approved manufacturers Diffusers, Registers, Grilles: Metalaire Louvers: Air Balance Entry 16: Specification section 233600 – AIR TERMINALS At paragraph 2.1.A Manufacturers, subject to compliance with the specifications, add the following as approved manufacturers Metalaire Entry 17: Specification section 260500 – Basic Electrical Materials and Methods, 1.3 Add Subsection 1.3.C. as follows: C. All products shall comply with the Buy America Act. Entry 18: Specification section 263213 – Generator, Part 2.1A Add Blue Star Power Systems to list of approved manufacturers. Entry 19: Specification section 263213 – Generator, Part 2.1A, 2 Revise altitude to 1200 ft above sea level. Generator capacity shall not be less than 225 kW based on temperature and altitude derating. Entry 20: Specification section 263213 – Generator, Part 3.7B, 11, b Delete any references to utility paralleling. Generator is emergency stand-by. Entry 21: Specification section 283100 – Fire Alarm, Part 2.1A Add Gamewell-FCI E3 series to the list of approved manufacturers. Page 4 of 5 Plans: Entry 22: The sentence “Phase 2 has a Calendar Completion Date of October 1, 2023” on the Phase Schedule Notes on Plan Sheet CSPP.3 (C8/C42) shall be eliminated (struck through and disregarded)). A “No Later Than (NLT)” completion date does not apply to the Contract Time. Entry 23: Replace Sheet A0.4 with Revised Sheet A0.4 (Attachment No. 3) Updated with Energy Code ASHRAE 90.1 (2016) Standard. Entry 24: Replace Sheet M2.1 with Revised Sheet M2.1 (Attachment No 4) Revised pipe routing to avoid piping over Data Rooms. Entry 25: Replace Sheet M3.1 with Revised Sheet M3.1 (Attachment No 4) Revised pipe routing to avoid piping over Data Rooms. Entry 26: Replace Sheet M7.1 with Revised Sheet M7.1 (Attachment No 4) Added Mechanical ComCheck Report to plans. Entry 27: Add the following paragraph to General Power Note 18 on Sheet E0.0 As part of Phase 1, mechanical equipment serving existing building will be temporality relocated. See mechanical plans. Provide temporary conduit and wiring as required to extend existing circuit to relocated outdoor mechanical unit. Once new electrical service is in place, provide temporary plaques at each electrical service per NEC until old service is removed. Entry 28: Replace Sheet E0.2 with Revised Sheet E0.2 (Attachment No 5) Shifted site lighting poles to comply with aircraft wing-tip clearances. Removed (1) Type S1 Luminaire. Added (1) Type S2A luminaire mounted to building. Entry 29: Replace Sheet E2.1 with Revised Sheet E2.1 (Attachment No 5) Add electrical connection to ETD location. Add data outlet locations in TSA Office. Entry 30: Replace Sheet E3.1 with Revised Sheet E3.1 (Attachment No 5) Add data outlet locations in TSA Office. Entry 31: Replace Sheet E6.2 with Revised Sheet E6.2 (Attachment No 5) Revise schedule for Panel T. Entry 32: Replace Sheet E7.2 with Revised Sheet E7.2 (Attachment No 5) Detail 5 - Revise resolution for video wall. Page 5 of 5 Other: Entry 33: As per Note 5 on Plan Sheet AD1.0, the General Contractor shall coordinate with the “System Integrator” Contractor (TSA Approved Equipment Contractor). The following documents are attached to this addendum as supplemental information that is needed for coordination with the “System Integrator”. (Attachment No. 6) TSA System Integrators (contact information) Existing TSA Checkpoint Equipment Inventory TSA Statement of Work Entry 34: Attached to this addendum is the current plan holders list (as of April 19, 2022) for reference (Attachment No. 7). Entry 35: Attached to this addendum is the Agenda for the Pre-Bid Meeting that was conducted on Thursday, April 14 (Attachment No. 8). END OF CHANGES PER ADDENDUM NO. 1 Prepared by: Alfred Benesch & Company Signature of Preparer: _________________ 825 “M” Street, Suite 100 Lincoln, NE 68508 (402) 479-2200 FAX: (402) 479-2276 TERMINAL EXPANSION KEARNEY REGIONAL AIRPORT (EAR) KEARNEY, NEBRASKA AIP 3-31-0045-036 (CARES) ADDENDUM NO. 1 ATTACHMENT NO. 1 Table of Contents Kearney Regional Airport (EAR) Terminal Expansion (2022) Attachment No. 1 AIP No. 3-31-0045-036 Benesch Proj. No. 112045.00 v TABLE OF CONTENTS DIVISION NO./TITLE PAGE # PROPOSAL SUBMITTAL CHECKLIST i CERTIFICATION SHEET iii TABLE OF CONTENTS v ARTICLE 1 – CONTRACT DOCUMENTS REQUESTS FOR BIDS/INVITATION FOR BIDS RFB.1 NOTICE TO BIDDERS NTB.1 INSTRUCTIONS TO BIDDERS ITB.1 PROPOSAL FORM P.1 DBE Utilization Statement P.11 DBE Letter of Intent P.13 Tentative List of Subcontractors P.15 Certificate of Buy American Compliance For Total Facility P.17 Buy American Waiver Request P.19 Buy American Component Cost Calculation Table P.21 Buy American Conformance Listing P.23 Certificate of Bidder Regarding Tax Deliquency and Felony Convictions P.25 Signature of Bidder P.27 CONTRACT AGREEMENT C.1 List of Subcontractors C.7 Payment Bond C.9 Performance Bond C.11 Final DBE Confirmation Form C.15 ARTICLE 2 – SUPPLEMENTARY PROVISIONS SUPPLEMENTARY POVISIONS PAGE 1 OF 30 SPECIAL CONDITION SPECIFICATIONS SCS.1 ARTICLE 3 - DAVIS-BACON WAGE DETERMINATIONS DAVIS-BACON WAGE DETERMINATIONS DB.1 ARTICLE 4 – FAA GENERAL CONTRACT PROVISIONS SECTION 10– DEFINITION OF TERMS GP-10.1 SECTION 20 – PROPOSAL REQUIREMENTS AND CONDITIONS GP-20.1 SECTION 30 – AWARD AND EXECUTION OF CONTRACT GP-30.1 SECTION 40 – SCOPE OF WORK GP-40.1 SECTION 50 – CONTROL OF WORK GP-50.1 SECTION 60– CONTROL OF MATERIALS GP-60.1 SECTION 70 – LEGAL REGULATIONS AND RESPONSIBILITY TO PUBLIC GP-70.1 SECTION 80 – PROSECUTION AND PROGRESS GP-80.1 SECTION 90 – MEASUREMENT AND PAYMENT GP-90.1 Addendum No. 1 Kearney Regional Airport (EAR) Terminal Expansion (2022) Addendum No. 1 AIP No. 3-31-0045-036 Benesch Proj. No. 112045.00 vi ARTICLE 5 – BENESCH CREATED SPECIFICATIONS B-101 AIRPORT SAFETY MEASURES B-101.1 B-102 CONSTRUCTION STAKING B-1.02.1 B-103 INCIDENTAL REMOVALS B-103.1 B-104 WATER LINES B-104.1 B-105 SANITARY SEWER LINES B-105.1 B-106 CONCRETE CURB AND GUTTER, CONCRETE SURFRACING, AND SIDEWALKS B-106.1 B-107 TRAFFIC SIGNS AND POSTS B-107.1 B-108 LANDSCAPING B-108.1 ARTICLE 6 – CITY OF KEARNEY STANDARD SPECIFICATIONS FOR MUNICIPAL CONSTRUCTION SECTION 3 – WATER MAIN, VALAVES, HYDRANTS AND APPURTENANCES N/A SECTION 4 – SANITARY SEWER N/A SECTION 11 – CONCRETE CURBS, CURBS AND GUTTERS, CONCRETE SURFACING, SIDEWEALKS, DRIVWAYS AND BIKEWAYS N/A APPENDIX 1 – FAA STANDARD SPECIFICATIONS C-100 CONTRACTOR QUALITY CONTROL PROGRAM (CQCP) C-100.1 C-102 TEMPORARY AIR AND WATER POLLUTION, SOIL EROSION, AND SILTATION CONTROL C-102.1 C-105 MOBILIZATION C-105.1 C-110 METHOD OF ESTIMATING PERCENTAGE OF MATERIAL WITHIN SPECIFICATION LIMITS (PWL) C-110.1 P-101 PREPARATION/REMOVAL OF EXISTING PAVEMENTS P-101.1 P-152 EXCAVATION, SUBGRADE, AND EMBANKMENT P-152.1 P-153 CONTROLLED LOW-STRENGTH MATERIAL (CL) P-154.1 P-209 CRUSHED AGGREGATE BASE COURSE P-209.1 P-501 CEMENT CONCRETE PAVEMENT P-501.1 P-605 JOINT SEALANTS FOR PAVEMENT P-605.1 P-610 CONCRETE FOR MISCELLANEOUS STRUCTURES P-610.1 P-620 RUNWAY AND TAXIWAY MARKING P-620.1 F-162 CHAIN-LINK FENCE F-162.1 D-701 PIPE FOR STORM DRAINS AND CULVERTS D-701.1 D-705 PIPE UNDERDRAINS FOR AIRPORTS D-705.1 D-751 MANHOLES, CATCH BASINS, INLETS, AND INSPECTION HOLES D-751.1 T-901 SEEDING T-901.1 T-905 TOPSOIL T-905.1 T-908 MULCHING T-908.1 L-110 AIRPORT UNDERGROUND ELECTRICAL DUCT BANKS AND CONDUITS L-110.1 L-125 INSTALLATION OF AIRPORT LIGHTING SYSTEMS L-125.1 Attachment No. 1 Kearney Regional Airport (EAR) Terminal Expansion (2022) Addendum No. 1 AIP No. 3-31-0045-036 Benesch Proj. No. 112045.00 vii APPENDIX 2 – ARCHITECTURAL AND MEP SPECIFICATIONS DIVISION 01 GENERAL REQUIREMENTS 01 3000 Administrative Requirements – Building Only 01 7000 Execution and Closeout Requirements – Building Only 01 7800 Closeout Submittals DIVISION 02 EXISTING CONDITIONS 02 4100 Demolition DIVISION 03 CONCRETE 03 3000 Cast-In-Place Concrete 03 3600 Special Concrete Floor Finishes (Polished) 03 3900 Concrete Curing / Proactive Moisture Control 03 5400 Cast Underlayment DIVISION 04 MASONRY 04 0511 Mortar and Masonry Grout 04 2000 Unit Masonry 04 4313 Stone Masonry Veneer DIVISION 05 METALS 05 1200 Structural Steel Framing 05 2100 Steel Joist Framing 05 3100 Steel Decking 05 3150 EPIC Acoustical Roof Decking 05 4000 Cold-Formed Metal Framing 05 5000 Metal Fabrications 05 5133 Metal Ladders DIVISION 06 WOOD AND PLASTICS 06 1000 Rough Carpentry 06 4100 Architectural Wood Casework 06 8316 Fiberglass Reinforced Paneling DIVISION 07 THERMAL AND MOISTURE PROTECTION 07 2100 Thermal Insulation 07 2119 Foamed-In-Place Insulation 07 2129 Sprayed Insulation 07 2700 Air Barriers 07 4113 Metal Roof Panels 07 4213.17 Metal Plate Wall Panels – Revelar 07 4213.23 Metal Composite Material Wall Panels 07 4219 Composite Framing Support (CFS) 07 4450 Fiber Cement Wall Panels 07 5423.11 TPO Roofing (Induction Weld) 07 6200 Sheet Metal Flashing and Trim 07 7200 Roof Accessories 07 8400 Firestopping 07 9200 Joint Sealants 07 9513 Expansion Joint Cover Assemblies Attachment No. 1 Kearney Regional Airport (EAR) Terminal Expansion (2022) Addendum No. 1 AIP No. 3-31-0045-036 Benesch Proj. No. 112045.00 viii DIVISION 08 OPENINGS 08 1113 Hollow Metal Doors and Frames 08 1416 Flush Wood Doors 08 3323 Overhead Coiling Doors 08 3328 Side Folding Security Grilles 08 4229 Automatic Entrances 08 4233 Revolving Door Entrances 08 4313 Aluminum-Framed Storefronts 08 4413 Glazed Aluminum Curtain Walls 08 7100 Door Hardware 08 8000 Glazing DIVISION 09 FINISHES 09 2116 Gypsum Board Assemblies 09 3000 Tiling 09 5100 Acoustical Ceilings 09 6500 Resilient Flooring 09 6623 Resinous Matrix Terrazzo Flooring 09 6813 Tile Carpeting 09 7200 Wall Coverings 09 8400 Acoustic Room Components 09 9113 Exterior Painting 09 9123 Interior Painting 09 9672 Fluid Applied Insulative Coatings DIVISION 10 SPECIALITIES 10 1400 Signage 10 2600 Wall and Door Protection 10 2800 Toilet, Bath, and Laundry Accessories 10 4313 Automatic External Defibrillator Cabinets 10 4400 Fire Protection Specialties DIVISION 12 FURNISHINGS 12 2413 Roller Window Shades 12 3600 Countertops DIVISION 14 CONVEYING SYSTEMS 14 5400 Baggage Handling Systems DIVISION 21 FIRE SUPPRESSION 21 0100 General Requirements for Fire Suppression 21 1000 Water-Based Fire-Suppression Systems DIVISION 22 PLUMBING 22 0100 General Requirements for Plumbing 22 0523 Valves for Plumbing 22 0720 Pipe Insulation for Plumbing 22 1116 Water Disturbing Piping 22 1123 Domestic Water Pumps 22 1316 Drainage and Vent Piping 22 1319 Plumbing Specialties 22 3300 Domestic Water Heaters 22 4000 Plumbing Fixtures DIVISION 23 HEATING, VENTILATING, AND AIR CONDITIONING (HVAC) 23 0100 General Requirements for Mechanical Systems Attachment No. 1 Kearney Regional Airport (EAR) Terminal Expansion (2022) Addendum No. 1 AIP No. 3-31-0045-036 Benesch Proj. No. 112045.00 ix 23 0500 Basic Mechanical Materials and Methods 23 0505 Basic Mechanical Piping Materials and Methods 23 0523 Valves for HVAC 23 0553 Identification for Mechanical Piping and Equipment 23 0593 Testing, Adjusting, and Balancing 23 0700 Duct Installation 23 0710 Equipment Insulation 23 0720 Pipe Insulation for HVAC 23 0900 HVAC Instrumentation and Controls 23 0960 Variable Frequency Drives 23 0993 Sequence of Operation for HVAC Controls 23 1123 Fuel Gas Piping 23 2113 Hydronic Piping 23 2123 Hydronic Pumps 23 3113 Metal Ducts and Accessories 23 3423 Power Ventilators 23 3600 Air Terminals 23 5240 Condensing Boilers 23 5523 Gas-Fired Radiant Heaters 23 6423 Air-Cooled Water Chillers 23 7313 Modular Air Handling Unit 23 8126 Split-System Air-Conditioning Units 23 8239 Unit Heaters 23 8316 Radiant Heating Piping 23 8316.10 EPS Floor Panels For Radiant Heating Hydronic Piping DIVISION 26 ELECTRICAL 26 0100 General Electric Requirements 26 0500 Basic Electrical Materials and Methods 26 0600 Grounding and Bonding 26 2416 Panelboards 26 2726 Wiring Devices 26 2816 Disconnect Switches and Circuit Breakers 26 2913 Motor Controllers 26 3213 Packaged Engine Generators 26 4313 Surge Protective Devices 26 5100 Lighting 26 5200 Lighting Control DIVISION 27 COMMUNICATIONS 27 0528 Low Voltage Conduit System 27 1500 Communication Cabling Systems 27 4134 Audio Visual Systems DIVISION 28 ELECTRONIC SAFETY AND SECURITY 28 1000 Integrated Security System 28 1100 Security Cabling 28 1300 Access Control 28 2300 Video Surveillance 28 3100 Fire Alarm Attachment No. 1 Kearney Regional Airport (EAR) Terminal Expansion (2022) Addendum No. 1 AIP No. 3-31-0045-036 Benesch Proj. No. 112045.00 x APPENDIX 3 – SAFETY AND PHASING PLAN (CSPP) APPENDIX 4 – SAMPLE CONTRACTOR SAFETY PLAN COMPLIANCE DOCUMENT (SPCD) APPENDIX 5 – FAA AC 150/5370-2G (OPERATIONAL SAFETY ON AIRPORTS DURING CONSTRUCTION APPENDIX 6 – NATIONWIDE BUY AMERICAN WAIVERS ISSUED APPENDIX 7 – CONTRACTOR SHOP DRAWING SUBMITTAL COVER PAGE APPENDIX 8 – GEOTECHNICAL REPORT BORING LOGS END OF INDEX Attachment No. 1 TERMINAL EXPANSION KEARNEY REGIONAL AIRPORT (EAR) KEARNEY, NEBRASKA AIP 3-31-0045-036 (CARES) ADDENDUM NO. 1 Attachment No. 2 Davis Bacon Wage Rates “General Decision Number: NE20220066 03/18/2022” Kearney Regional Airport (EAR) Terminal Expansion (2022) Addendum No. 1 Attachment No. 2 Kearney Regional Airport (EAR) Terminal Expansion (2022) Addendum No. 1 Attachment No. 2 Kearney Regional Airport (EAR) Terminal Expansion (2022) Addendum No. 1 Attachment No. 2 Kearney Regional Airport (EAR) Terminal Expansion (2022) Addendum No. 1 Attachment No. 2 Kearney Regional Airport (EAR) Terminal Expansion (2022) Addendum No. 1 Attachment No. 2 Kearney Regional Airport (EAR) Terminal Expansion (2022) Addendum No. 1 Attachment No. 2 TERMINAL EXPANSION KEARNEY REGIONAL AIRPORT (EAR) KEARNEY, NEBRASKA AIP 3-31-0045-036 (CARES) ADDENDUM NO. 1 Attachment No. 3 Revised Plan Sheet A0.4 COMcheck Envelope Compliance Certificate SHEET NO. DATE PROJECT KEARNEY TERMINAL SEAL NO . RE VI SI ON S DA TE CIVIL ENGINEER DR AW N BY : DE SI GN ED BY : RE VI EW ED BY : QU AN TI TI ES CH EC KE D BY : ARCHITECT CONSULTANT K E A R N E Y R E G IO N A L A IR P O R T T E R M IN A L E X P A N S IO N K E A R N E Y , N E B R A S K A 03/11/2022 A0.4 CO M ch ec k E nv elo pe Co m pl ian ce C er tif ica te A d d e nd um # 1 - U p d a te E ne rg y C o d e R e fe re nc e 4 / 1 5 / 2 0 2 2 1 TERMINAL EXPANSION KEARNEY REGIONAL AIRPORT (EAR) KEARNEY, NEBRASKA AIP 3-31-0045-036 (CARES) ADDENDUM NO. 1 Attachment No. 4 Revised Plan Sheets (Mechanical) Sheets M2.1, M3.1 and M7.1 L ADA GATE L B IN S EM PTY B IN S EM PTY BINS EMPTY L3 P R O VISIO N 2 AIT2 ENTER EXIT ETD 2 24 SS ETD STSO TAB LE630 2 TDC/CAT TDC/CAT S M ITH S D E TE C TIO N H I- S C A N 6 0 4 0 C TiX P C 1 AVS WTMD CEIA TAB LE630 2 2 3'- 9" 3' 3 5 . 00 0 0 2 4 . 00 0 0 3 5 . 00 0 0 2 4 . 00 0 0 0 . 0 00 0 0 . 0 00 0 G T E 3 2 4 4.7 5 7 CA B D 6 5.8 D.2B.9 1.2 1.7 1.3 F EX. 1 B.1 E.8E.9D.4D.5 EX. A EX. B EX. C EX. D EX. EEX. B.9 EX. D.2 ACCU-133 ACCU-136 ACCH-1 3" C W S 3" C W R 3" H W R 3" H W S 3" C W S 3" C W R 3" C W S 3" C W R MECHANICAL 128 AIRPORT STORAGE 130 AIRLINE OFFICE 125 AIRLINE WORK AREA 124 TSA DATA 136MAIN DATA 133 PRIVATE SCREENING ROOM 142 TSA BAG SCREENING 132 OUTBOUND BAGGAGE 131 TICKET COUNTER 121 TSA STORAGE 137 TSA OFFICE 140 TSA BREAK ROOM 138 TSA WORK AREA 134 TSA CHECKPOINT 141 BOARDING 144 DEPARTURES LOBBY 101 WAITING 102 AIRLINE BREAK AREA 123 TSA LOCKERS 135 SECURE HOLDROOM SOUTH 143 AIRLINE STORAGE 122 ALCOVE 126 FDC AC-133 AC-136 VBR-125 VBR-123 (T Y P .) M 20 1 RH-130-A RH-130-B RH-130-C VBR-134 VBR-140 VBR-143 VBR-132 VBR-137 VBR-121 M4.1 3 M207 2-1/2" HWS/R 3" CWS/R UP TO MEZZANINE M212 M212 1-1/2" HWS/R 1" CWS/R UP TO MEZZANINE 3/4" HWR 3/4" HWS 1" HWR 1" HWS 1" HWR M4.2 2 RADIANT HEAT MANIFOLD RADIANT HEAT MANIFOLD REF REF (TYP.) M215 2 1/ 2" H W R 2 1/ 2" H W S ALTERNATE #1ALTERNATE #1 M217 10 M6.2 10 M6.2 ZP-101 ZP-143 1" HWS (TYP.) 5 M6.2 3" CWR 3" CWS 3" HWS 3" HWR 3" HWR 3" HWS 3" CWS 3" HWS 1 (TYP.) M201 EX. 5 E 1 CA B D D.2B.9 1.2 F EX. 4 EX. 3 EX. 1 EX. 2 B.1 E.8E.9D.4D.5 EX. A EX. B EX. C EX. D EX. EEX. B.9 EX. D.2 CUSTODIAL 111 VENDING SECURE 146 CUSTODIAL 147 RENTAL OFFICE 107 RENTAL DESK 106 SECURITY 112 INBOUND BAGGAGE 109 BAGGAGE CLAIM 110 LOUNGE 104 FAA EQUIPMENT 108 RESTROOM 116 RESTROOM 115 RESTROOM 114 RESTROOM 117 RESTROOM 151 RESTROOM 152 RESTROOM 150 RESTROOM 149 ARRIVALS LOBBY 105 VESTIBULE AIRSIDE 110V VESTIBULE LANDSIDE 105V VENDING NON-SECURE 103 SECURE HOLDROOM NORTH 145 HALLWAY 113 HALLWAY 148 RH-109-B RH-109-A CUH-105V CUH-110V VBR-112 VBR-104 VBR-107 FC-110 1 1/ 2" H W R 1" C W S 1" C W R 1 1/4" HWR 1" HWR 1" HWS 3/4" HWR 3/4" HWS 3/4" HWS 3/4" HWR 3/4" HWS 3/4" HWR 1" HWS 1" HWR 1-1/2" HWS/R 1" CWS/R UP TO MEZZANINE 1 1/4" HWS 1" C W R 1" C W S 3/ 4" H W S 3/ 4" H W R CEILING CLEARANCES IN AREA 'B' ARE VERY LIMITED. COORDINATE WITH OTHER TRADES PRIOR TO INSTALLATION TO AVOID CONFLICTS. PIPING/PLUMBING GENERAL NOTES 1. DO NOT ROUTE PIPING ABOVE ELECTRICAL PANELS. MAINTAIN ALL CODE REQUIRED CLEARANCES. 2. SPACE ABOVE CEILINGS IS LIMITED. COORDINATE PIPE ROUTING WITH ALL OTHER TRADES. PROVIDE ALL ADDITIONAL OFFSETS AND TRANSITIONS AS REQUIRED TO COMPLETE INSTALLATION. 3. PLANS ARE SCHEMATIC IN NATURE. COORDINATE EXACT ROUTING AND EQUIPMENT LOCATIONS WITH ALL OTHER TRADES. PROVIDE ALL ADDITIONAL OFFSETS AS REQUIRED TO COMPLETE INSTALLATION. 4. INSTALL ALL ISOLATION VALVES AND BALANCING VALVES IN ACCESSIBLE LOCATIONS. 5. ALL PIPING SHOWN FOR CLARITY. ROUTE WASTE, VENT, WATER, AND GAS PIPING CONCEALED IN CHASES, IN WALLS, OR ABOVE CEILINGS AS REQUIRED. 6. DO NOT ROUTE WATER PIPING IN EXTERIOR WALLS UNLESS OTHERWISE NOTED. PIPING ROUTED IN EXTERIOR WALLS SHALL BE LOCATED ON THE INTERIOR SIDE OF INSULATION. 7. NOT ALL CLEANOUTS ARE SHOWN. PROVIDE CLEANOUTS PER UNIFORM PLUMBING CODE. EXTEND CLEANOUTS TO WALLS WHERE APPLICABLE. COORDINATE CLEANOUT LOCATIONS WITH GENERAL CONTRACTOR. 8. COORDINATE ALL BELOW GRADE PIPING WITH STRUCTURAL FOOTINGS. SLEEVE PIPING AS REQUIRED. SEE STRUCTURAL DRAWINGS. COORDINATE WITH GENERAL CONTRACTOR. 9. WASTE AND VENT RISERS ARE DESIGNATED BY . SEE WASTE AND VENT RISER DIAGRAMS ON SHEET M5.2 FOR WASTE AND VENT PIPE SIZES. 10. SEE PLUMBING FIXTURE SCHEDULE SHEET M7.3 FOR PLUMBING FIXTURE CONNECTION REQUIREMENTS. 11. ALL PENETRATIONS OF FIRE RESISTANT CONSTRUCTION SHALL BE SEALED WITH A LISTED FIRESTOPPING ASSEMBLY BY THE CONTRACTOR RESPONSIBLE FOR THE PENETRATION. X m o e y rr Is s e n g I n ee r I n g I n c m e c h a n ic a l | e le c tr ic a l | te c h n o lo g y | c o m m is s io n in g 49 40 N o rt h 1 1 8t h S tr ee t O m ah a, N E 6 8 16 4 P : 40 2. 4 91 .4 14 4 w w w .m o rr is s e y e n g in e e ri n g .c o m M E I P R O J E C T # : E N G I N E E R S O ET A T S P R O F E RBENF A KSA E O N S I AL M CH IAN CAL ∆ ∆ JASON R. E-12778 EICKMEIER SHEET NO. DATE PROJECT KEARNEY TERMINAL SEAL NO . RE VI SI ON S DA TE CIVIL ENGINEER DR AW N BY : DE SI GN ED BY : RE VI EW ED BY : QU AN TI TI ES CH EC KE D BY : ARCHITECT CONSULTANT K E A R N E Y R E G IO N A L A IR P O R T T E R M IN A L E X P A N S IO N K E A R N E Y , N E B R A S K A 2 0 3 7 1 03/11/2022 3/28/2022 M2.1 HV AC P IPI NG P LA N SCALE:N 1/8" = 1'-0"M2.1 1 MECHANICAL PIPING PLAN - AREA A SCALE:N 1/8" = 1'-0"M2.1 2 MECHANICAL PIPING PLAN - AREA B KEYNOTES M201 DO NOT ROUTE DUCTWORK OR PIPING ABOVE ELECTRICAL PANELS. MAINTAIN ALL NEC REQUIRED CLEARANCES. M207 ROUTE CHILLED WATER DOWN WALL, AND OUT TO CHILLER. PROVIDE ISOLATION VALVES, DRAINDOWN VALVES, PRESSURE GAUGE, AND THERMOMETERS ON SUPPLY AND RETURN PIPING, SEE RISER FOR DETAILS. M212 PROVIDE IN-FLOOR RADIANT HEATING FOR THE APPROXIMATE AREA INDICATED. M215 ROUTE PIPING TIGHT TO THE TOP OF PLYWOOD LID. PAINT TO MATCH ADJACENT AND KEEP PIPING OUT OF LINE OF SIGHT FROM GROUND LEVEL. M217 DEDUCT ALTERNATE #1: ROUTE CHILLED WATER PIPING BELOW GRADE FROM CHILLER TO MECHANICAL ROOM. SEE SPECIFICATIONS FOR BELOW GRADE PIPING. 1 AD DE ND UM 1 4/ 15 /2 02 2 L ADA GATE L B IN S EM PTY B IN S EM PTY BINS EMPTY L3 P R O VISIO N 2 AIT2 ENTER EXIT ETD 2 24 SS ETD STSO TAB LE630 2 TDC/CAT TDC/CAT S M ITH S D E TE C TIO N H I- S C A N 6 0 4 0 C TiX P C 1 AVS WTMD CEIA TAB LE630 2 2 3'- 9" 3' 3 5 . 00 0 0 2 4 . 00 0 0 3 5 . 00 0 0 2 4 . 00 0 0 0 . 0 00 0 0 . 0 00 0 G T E 3 2 4 4.7 5 7 CA B D 6 5.8 D.2B.9 1.2 1.7 1.3 F EX. 1 B.1 E.8E.9D.4D.5 EX. A EX. B EX. C EX. D EX. EEX. B.9 EX. D.2 WH-1 WH-1 WH-1 WH-1 WH-1 12" DN-1 S-1 M4.1 3 S-1 3/4" CW 3/ 4" C W 1/ 2" H W C 1 1/ 2" H W 2 1/ 2" S C W 3/4" CW 3/4" CW VENDING NON-SECURE 103 MECHANICAL 128 AIRPORT STORAGE 130 AIRLINE OFFICE 125 AIRLINE WORK AREA 124 TSA DATA 136 MAIN DATA 133 PRIVATE SCREENING ROOM 142 TSA BAG SCREENING 132 OUTBOUND BAGGAGE 131 TICKET COUNTER 121 TSA STORAGE 137 TSA OFFICE 140 TSA BREAK ROOM 138 TSA WORK AREA 134 TSA CHECKPOINT 141 BOARDING 144 DEPARTURES LOBBY 101 WAITING 102 AIRPORT SUPPLY 153 AIRLINE BREAK AREA 123 TSA LOCKERS 135 SECURE HOLDROOM SOUTH 143 AIRLINE STORAGE 122 ALCOVE 126 HB-1 EW-1 TMV-1 3" D-3 WH-1 AC-133 AC-136 8" OF 8" OF UP 12" OF 8" OF UP 8" ST OB-1 OB-1 DN (R) DN (R) (T Y P .) M 20 1 WH-1 3/4" CW DB-1 3/4" CD GAS METER RH-130-A RH-130-B RH-130-C TCP 4" V 3/4" CW 1 1/2" G 3/ 4" G 3/4" G, 1-1/2" HW, 1/2" HWC, 1" CW, AND 2-1/2" SCW UP TO MEZZANINE 3/4" G 1/ 2" G 1/2" G 1/ 2" G 1" C W 1 1/2" G 2" W 2" W DN 2" W UP F.C.O. F.C.O. 1 1/2" V UP 1 1/2" V UP 1-1/2" V UP TO VTR (TYP.)M215 M218 M218 18'-8" TD-1 18'-8" TD-1 12'-8" TD-1 30'-9" TD-1 (TYP.) 7 M6.1 M220 M222 12" ST DN 8" ST UP8" ST UP 12" ST M222 M202 M223 (TYP.) 10 M6.1 C.O. 1 1/ 4" C D M233 MEZZANINE ACCESS 120 3/4" CW 1/ 2" H W C 1 1/ 2" H W 2 1/ 2" S C W 3/ 4" G 1" C W 1 1/ 4" V 1 EX. 5 E 1 CA B D D.2B.9 1.2 F EX. 4 EX. 3 EX. 1 EX. 2 B.1 E.8E.9D.4D.5 EX. A EX. B EX. C EX. D EX. EEX. B.9 EX. D.2 WH-1 M4.1 2 2 M4.3 CUSTODIAL 111 VENDING SECURE 146 CUSTODIAL 147 RENTAL OFFICE 107 RENTAL DESK 106 SECURITY 112 INBOUND BAGGAGE 109 BAGGAGE CLAIM 110 LOUNGE 104 FAA EQUIPMENT 108 RESTROOM 116 RESTROOM 115 RESTROOM 114 RESTROOM 117 RESTROOM 151 RESTROOM 152 RESTROOM 150 RESTROOM 149 ARRIVALS LOBBY 105 VESTIBULE AIRSIDE 110V VESTIBULE LANDSIDE 105V 3/4" CW MS-1 MS-1 VENDING NON-SECURE 103 SECURE HOLDROOM NORTH 145 HALLWAY 113 AIRPORT SUPPLY 153 HALLWAY 148 DN (R) DN (R) WH-1 3/4" CW HB-1 RH-109-B RH-109-A 3/4" CW 3/4" HW 3/4" SCW 1/2" G 1/2" G 3/4" G 3/4" G UP 1 1/2" V 1 1/2" V UP 1 1/2" V UP WH-1DN (R)M218 4" ST 4" ST 4" ST DN (R) M218 4" ST 4" ST M218 M2184" ST 4" ST FC-110 3/4" CD 3/4" CD CEILING CLEARANCES IN AREA 'B' ARE VERY LIMITED. COORDINATE WITH OTHER TRADES PRIOR TO INSTALLATION TO AVOID CONFLICTS. MEZZANINE ACCESS 120 3" FS-1 F.C.O. D.G.C.O V UP TO VTR PIPING/PLUMBING GENERAL NOTES 1. DO NOT ROUTE PIPING ABOVE ELECTRICAL PANELS. MAINTAIN ALL CODE REQUIRED CLEARANCES. 2. SPACE ABOVE CEILINGS IS LIMITED. COORDINATE PIPE ROUTING WITH ALL OTHER TRADES. PROVIDE ALL ADDITIONAL OFFSETS AND TRANSITIONS AS REQUIRED TO COMPLETE INSTALLATION. 3. PLANS ARE SCHEMATIC IN NATURE. COORDINATE EXACT ROUTING AND EQUIPMENT LOCATIONS WITH ALL OTHER TRADES. PROVIDE ALL ADDITIONAL OFFSETS AS REQUIRED TO COMPLETE INSTALLATION. 4. INSTALL ALL ISOLATION VALVES AND BALANCING VALVES IN ACCESSIBLE LOCATIONS. 5. ALL PIPING SHOWN FOR CLARITY. ROUTE WASTE, VENT, WATER, AND GAS PIPING CONCEALED IN CHASES, IN WALLS, OR ABOVE CEILINGS AS REQUIRED. 6. DO NOT ROUTE WATER PIPING IN EXTERIOR WALLS UNLESS OTHERWISE NOTED. PIPING ROUTED IN EXTERIOR WALLS SHALL BE LOCATED ON THE INTERIOR SIDE OF INSULATION. 7. NOT ALL CLEANOUTS ARE SHOWN. PROVIDE CLEANOUTS PER UNIFORM PLUMBING CODE. EXTEND CLEANOUTS TO WALLS WHERE APPLICABLE. COORDINATE CLEANOUT LOCATIONS WITH GENERAL CONTRACTOR. 8. COORDINATE ALL BELOW GRADE PIPING WITH STRUCTURAL FOOTINGS. SLEEVE PIPING AS REQUIRED. SEE STRUCTURAL DRAWINGS. COORDINATE WITH GENERAL CONTRACTOR. 9. WASTE AND VENT RISERS ARE DESIGNATED BY . SEE WASTE AND VENT RISER DIAGRAMS ON SHEET M5.2 FOR WASTE AND VENT PIPE SIZES. 10. SEE PLUMBING FIXTURE SCHEDULE SHEET M7.3 FOR PLUMBING FIXTURE CONNECTION REQUIREMENTS. 11. ALL PENETRATIONS OF FIRE RESISTANT CONSTRUCTION SHALL BE SEALED WITH A LISTED FIRESTOPPING ASSEMBLY BY THE CONTRACTOR RESPONSIBLE FOR THE PENETRATION. X CITY OF KEARNEY COMPLIANCE NOTES 1. ALL PLUMBING VENTS SHALL MEET THE MINIMUM SIZE REQUIREMENTS OF THE 2015 UNIFORM PLUMBING CODE. 2. THE DOMESTIC WATER METER FURNISHED BY THE CITY OF KEARNEY UTILITIES DEPARTMENT AND INSTALLED BY THE CONTRACTOR MUST BE LOCATED IN AN AREA THAT WILL ALLOW FOR EASE OF MAINTENANCE. THE METER CANNOT BE INSTALLED ABOVE A CEILING. THE CITY UTILTIES DEPARTMENT WILL FURNISH A WIRE TO RUN FROM THE INDOOR WATER METER TO THE OUTDOOR REMOTE READER. THE WIRE WILL BE INSTALLED BY THE CONTRACTOR. 3. MAINTAIN SEPARATION BETWEEN THE WATER SERVICE AND SANITARY SEWERS AS STATED IN "RECOMMENDED STANDARDS FOR WATER WORKS 8.8.2" 4. BACKFLOW DEVICES SHALL BE INSTALLED AS PER CITY OF KEARNEY CODE CHAPTER 10-405. FINAL DETERMINATION OF BACKFLOW REQUIREMENTS WILL BE MADE BY THE CITY OF KEARNEY'S WATER QUALITY COORDINATOR. 5. TEMPORARY WATER SERVICE, IF REQUIRED BY THE CONTRACTOR FOR CONSTRUCTION, WILL REQUIRE THE DOMESTIC WATER METER TO BE INSTALLED IN IT'S PERMANENT LOCATION, PROTECTED FROM COLD TEMPERATURES, AND AN ACCOUNT WILL NEED TO BE SET UP WITH THE CITY OF KEARNEY'S UTILITIY BILLING DEPARTMENT TO PAY FOR ALL WATER USE. m o e y rr Is s e n g I n ee r I n g I n c m e c h a n ic a l | e le c tr ic a l | te c h n o lo g y | c o m m is s io n in g 49 40 N o rt h 1 1 8t h S tr ee t O m ah a, N E 6 8 16 4 P : 40 2. 4 91 .4 14 4 w w w .m o rr is s e y e n g in e e ri n g .c o m M E I P R O J E C T # : E N G I N E E R S O ET A T S P R O F E RBENF A KSA E O N S I AL M CH IAN CAL ∆ ∆ JASON R. E-12778 EICKMEIER SHEET NO. DATE PROJECT KEARNEY TERMINAL SEAL NO . RE VI SI ON S DA TE CIVIL ENGINEER DR AW N BY : DE SI GN ED BY : RE VI EW ED BY : QU AN TI TI ES CH EC KE D BY : ARCHITECT CONSULTANT K E A R N E Y R E G IO N A L A IR P O R T T E R M IN A L E X P A N S IO N K E A R N E Y , N E B R A S K A 2 0 3 7 1 03/11/2022 3/28/2022 M3.1 PL UM BI NG P LA N SCALE:N 1/8" = 1'-0"M3.1 1 PLUMBING PLAN - AREA A SCALE:N 1/8" = 1'-0"M3.1 2 PLUMBING PLAN - AREA B KEYNOTES M201 DO NOT ROUTE DUCTWORK OR PIPING ABOVE ELECTRICAL PANELS. MAINTAIN ALL NEC REQUIRED CLEARANCES. M202 NEW 2 PSIG NATURAL GAS SERVICE BY GAS COMPANY SEE M7.1 FOR TOTAL CONNECTED LOAD. COORDINATE ALL REQUIREMENTS WITH NORTHERN NATURAL GAS. M215 ROUTE PIPING TIGHT TO THE TOP OF PLYWOOD LID. PAINT TO MATCH ADJACENT AND KEEP PIPING OUT OF LINE OF SIGHT FROM GROUND LEVEL. M218 RELOCATE EXISTING DOWNSPOUT TO NEW EXTERIOR. CONNECT TO EXISTING LEADER. FIELD VERIFY EXISTING CONDITIONS. M220 ALTERNATE #1: - RELOCATE HB-1 FROM SOUTH WALL OF MECHANICAL ROOM TO EAST WALL. - REMOVE WH-1 AND ROUTE 3/4" CW BELOW GRADE TO YH-1 IN IT'S PLACE. BELOW GRADE PIPING TO BE CONTINOUS WITH NO FITTINGS BELOW GRADE. - REMOVE GAS PIPING TO RH-130-A AND RELOCATE RH-130-B. - REMOVE TRENCH DRAIN IN AIRPORT STORAGE 130 AND REVISE LENGTH OF TRENCH DRAIN IN OUTBOUND BAGGAGE 131. M222 PROVIDE CLEANOUT AT THE BASE OF PLUMBING STACK. M223 PROVIDE SIGN AT WATER HYDRANT. "NON-POTABLE USE ONLY" M233 PROVIDE STOP VALVE WITH WATER CONNECTION FOR OWNER PROVIDED INSTANT HOT WATER DISPENSER. 1 AD DE ND UM 1 4/ 15 /2 02 2 P.T.T PRESSURE/TEMPERATURE TEST PORT GLOBE VALVE GATE VALVE BALANCING VALVE ISOLATION VALVE (BALL OR BUTTERFLY) ELBOW DN / ELBOW UP PIPE TEE / PIPE ELBOW UNION STRAINER CHECK VALVE (ARROW INDICATES FLOW) AUTOMATIC CONTROL VALVE TWO-WAY/THREE-WAY PRESSURE REGULATING VALVE (PRV) PRESSURE GAUGE THERMOMETER DOMESTIC COLD WATER (CW) DOMESTIC HOT WATER (HW) (NUMBER INDICATES TEMPERATURE) DOMESTIC HOT WATER CIRCULATION (HWC) (NUMBER INDICATES TEMPERATURE) SANITARY WASTE (BELOW GRADE) SANITARY WASTE (ABOVE GRADE) VENT PIPING STORM PIPING (BELOW GRADE) STORM PIPING (ABOVE GRADE) OVERFLOW STORM PIPING (BELOW GRADE) OVERFLOW STORM PIPING (ABOVE GRADE) ACID WASTE PIPING (BELOW GRADE) ACID WASTE PIPING (ABOVE GRADE) ACID VENT PIPING COMPRESSED AIR PIPING NATURAL GAS PIPING SITE SANITARY PIPING SITE STORM PIPING SITE WATER PIPING HOT WATER SUPPLY PIPING HOT WATER RETURN PIPING COLD WATER SUPPLY PIPING COLD WATER RETURN PIPING CONDENSER WATER SUPPLY PIPING CONDENSER WATER RETURN PIPING REFRIGERANT LIQUID LINE REFRIGERANT SUCTION LINE REFRIGERANT HOT GAS DISCHARGE LINE GAS COCK FLOOR DRAIN - SIZE TYPE ROOF DRAIN - SIZE TYPE OVERFLOW DRAIN - SIZE TYPE HOSE BIBB WALL HYDRANT (NON-FREEZE) VENT THROUGH ROOF INVERT ELEVATION FLOW LINE WATER CLOSET (SEE SPECIFICATIONS FOR TYPE) URINAL (SEE SPECIFICATIONS FOR TYPE) LAVATORY (SEE SPECIFICATIONS FOR TYPE) SINK (SEE SPECIFICATIONS FOR TYPE) ELECTRIC WATER COOLER (SEE SPECIFICATIONS FOR TYPE) MOP SINK (SEE SPECIFICATIONS FOR TYPE) DUCTILE IRON CAST IRON POLY VINYL CHLORIDE HEAT PUMP LOOP SUPPLY PIPING HEAT PUMP LOOP RETURN PIPING GLYCOL WATER SUPPLY PIPING GLYCOL WATER RETURN PIPING AIR VENT COIL CONDENSATE DRAIN (SLOPE TO DRAIN) SOLENOID VALVE SYMBOL DESCRIPTION SYMBOL PLUMBING TYPICAL PIPING DESCRIPTION HYDRONIC HVAC PIPING REFRIGERATION PIPING MECHANICAL SYMBOLS ST OF AW GREASE WASTE (BELOW GRADE) GREASE WASTE (ABOVE GRADE) GW ST OF AW GW GREASE VENT PIPINGGV AV A G SAN W ST HWS HWR CWS CWR CS CR RL RS RD CD GWR GWS HPLR HPLS PVC CI VTR I.E. F.L. WC UR L S EWC MS DI 2" OD-1 2" RD-1 2" D-1 WH HB S SENSOR THERMOSTAT HUMIDISTAT MOTORIZED CONTROL DAMPER WITH ACTUATOR BACKDRAFT DAMPER VOLUME DAMPER FIRE DAMPER WITH SLEEVE AND ACCESS DOOR SMOKE DAMPER WITH SLEEVE AND ACCESS DOOR FIRE/SMOKE DAMPER WITH SLEEVE AND ACCESS DOOR SUPPLY AIR RETURN AIR EXHAUST AIR RELIEF AIR OUTSIDE AIR MIXED AIR FIRE HYDRANT POST INDICATOR VALVE O,S & Y VALVE FLOW SWITCH ALARM CHECK VALVE FIRE SPRINKLER PIPING STANDPIPE PIPING FIRE HOSE CABINET FIRE VALVE CABINET SPRINKLER BRANCH AND HEADS SIDEWALL SUPPLY REGISTER OR GRILLE SIDEWALL RETURN OR EXHAUST REGISTER OR GRILLE SUPPLY AIR REGISTER SUPPLY AIR , OUTSIDE AIR OR MIXED AIR DUCT END OR RISER UP/RISER DN RETURN AIR, EXHAUST AIR OR RELIEF AIR DUCT END OR RISER UP/RISER DN RECTANGULAR DUCTWORK (WIDTH/DEPTH)(IN) (FIRST NUMBER IS SIDE SHOWN) ROUND DUCTWORK (DIAMETER)(IN) (SPIRAL DUCT IN EXPOSED AREAS) TURNING VANES HVAC FIRE PROTECTION 6x6 R-1 100 6x6 R-1 100 6 Ø D-1 100 NECKSIZE (IN), TAG AIRFLOW (CFM) NECKSIZE (IN), TAG AIRFLOW (CFM) NECKSIZE (IN), TAG AIRFLOW (CFM) F SP S.A. R.A. E.A. RLF.A. O.A. M.A. P.I.V. S T H FSFVC FHC FH M B.D.D. V.D. FD SD FSD 12/8 12"Ø PIPING INSULATION SCHEDULE INSULATION TYPE INSULATION THICKNESS VAPOR RETARDER SERVICE REMARKSPIPING SIZES MINERAL FIBER 1/2" YES -ALLCONDENSATE DRAIN (COPPER) FLEXIBLE ELASTOMERIC 1/2" YES -1-1/4" AND SMALLERREFRIGERANT SUCTION (RS) FLEXIBLE ELASTOMERIC 1/2" YES -ALLREFRIGERANT LIQUID (RL) MINERAL FIBER 1-1/2" YES (1)1/2" TO 1-1/2"CHILLED WATER (CWS & CWR) MINERAL FIBER 2" YES (1)2" AND LARGERCHILLED WATER (CWS & CWR) MINERAL FIBER 1-1/2" NO -1/2" TO 1-1/4"HEATING HOT WATER (HWS & HWR) MINERAL FIBER 2" NO -1-1/2" AND LARGERHEATING HOT WATER (HWS & HWR) MINERAL FIBER 1/2" YES -ALLDOMESTIC COLD WATER (CW) MINERAL FIBER 1" NO -1/2" TO 2"DOMESTIC HOT WATER (WITH RECIRC.) NONE - - -ALLSANITARY WASTE FLEXIBLE ELASTOMERIC 1/2" YES -ALLROOF DRAIN BODIES (RD & OFD) MINERAL FIBER 1/2" YES -ALLPLUMBING VENTS (24" BELOW ROOF) MINERAL FIBER 1" YES -ALLSTORM DRAIN (ST & OF) REMARKS: 1. PROVIDE EXTERIOR PIPING INSULATION WITH ALUMINUM JACKET. DUCTWORK INSULATION SCHEDULE INSULATION TYPE INSULATION THICKNESS VAPOR RETARDER SERVICE REMARKSDUCTWORK APPLICATION MINIMUM R-VALUE MINERAL FIBER BLANKET 2" YES -ALLSUPPLY AIR CONCEALED ABOVE CEILING R-5 DUCT LINER 1-1/2" YES -RECTANGULARSUPPLY AIR EXPOSED, FINISHED SPACES R-5 DUCT LINER 1-1/2" YES -RECTANGULARRETURN AIR CONCEALED ABOVE CEILING R-5 DUCT LINER 1" NO (1)RECTANGULARRETURN / XFR AIR PLENUM BOOTS & TRANSFER DUCTS - MINERAL FIBER BOARD 2" YES -RECTANGULARSUPPLY AIR MECHANICAL ROOM R-6 MINERAL FIBER BOARD 2" YES -RECTANGULARRETURN AIR MECHANICAL ROOM R-6 MINERAL FIBER BOARD 2" YES -RECTANGULAROUTSIDE AIR MECHANICAL ROOM R-6 MINERAL FIBER BOARD 2" YES -RECTANGULARRELIEF AIR MECHANICAL ROOM R-6 REMARKS: 1. PLENUM BOOTS SHALL BE CONSTRUCTED OUT OF SHEETMETAL WITH ACOUSTICAL DUCT LINER. SEE DETAILS. NONE - - -ROUND RUNOUTSUPPLY AIR EXPOSED, FINISHED SPACES - DUCT LINER 1-1/2" YES -RECTANGULARRETURN AIR EXPOSED, FINISHED SPACES R-5 MINERAL FIBER BOARD 2" YES -LOUVER PLENUMALL ALL R-6 MINERAL FIBER BLANKET 2" YES -LOUVER PLENUM TO FANEXHAUST AIR CONCEALED ABOVE CEILING R-5 m o e y rr Is s e n g I n ee r I n g I n c m e c h a n ic a l | e le c tr ic a l | te c h n o lo g y | c o m m is s io n in g 49 40 N o rt h 1 1 8t h S tr ee t O m ah a, N E 6 8 16 4 P : 40 2. 4 91 .4 14 4 w w w .m o rr is s e y e n g in e e ri n g .c o m M E I P R O J E C T # : E N G I N E E R S O ET A T S P R O F E RBENF A KSA E O N S I AL M CH IAN CAL ∆ ∆ JASON R. E-12778 EICKMEIER SHEET NO. DATE PROJECT KEARNEY TERMINAL SEAL NO . RE VI SI ON S DA TE CIVIL ENGINEER DR AW N BY : DE SI GN ED BY : RE VI EW ED BY : QU AN TI TI ES CH EC KE D BY : ARCHITECT CONSULTANT K E A R N E Y R E G IO N A L A IR P O R T T E R M IN A L E X P A N S IO N K E A R N E Y , N E B R A S K A 2 0 3 7 1 03/11/2022 3/28/2022 M7.1 M EC HA NI CA L S CH ED UL ES REMARKS: 1. PUMP SHALL BE CERTIFIED TO NSF 372 FOR LOW-LEAD COMPLIANCE. 2. SEE WATER HEATER DETAIL FOR PIPING SPECIALTIES. 3. PUMP SHALL BE SCHEDULED THROUGH THE BUILDING AUTOMATION SYSTEM. WHEN ENABLED, THE PUMP SHALL CYCLE THROUGH THE USE OF AN AQUASTAT. DOMESTIC WATER PUMP SCHEDULE GENERAL PUMP - FLOW MOTOR REMARKS PLAN TAG MANUFACTURER MODEL SERVES TYPE GPM HEAD (FT) HP RPM VOLTAGE / PHASE TYPE TOTAL SHUTOFF HWCP-1 TACO 0013-IFC HW CIRC IN-LINE 0.5 30 FT 34 FT 0.17 3300 115 V / 1 O.D.P. (1) (2) (3) REMARKS: 1. DIRECT VENT HIGH EFFICIENCY WATER HEATER WITH GLASS LINED STORAGE TANK. 2. PROVIDE WITH PRESSURE / TEMPERATURE RELIEF VALVE. 3. PVC EXHAUST AND INTAKE - SIZE AND INSTALL PER MANUFACTURER'S RECOMMENDATIONS. PROVIDE CONCENTRIC VENT VERTICAL TERMINATION. 4. COORDINATE ELECTRICAL REQUIREMENTS WITH SUPPLIED UNIT AND WITH ELECTRICAL CONTRACTOR. GAS WATER HEATER SCHEDULE GENERAL TANK DOMESTIC HOT WATER ELECTRICAL GAS-FIRED HEATING REMARKS PLAN TAG MANUFACTURER MODEL SERVES STORAGE CAPACITY DIMENSIONS (DIA. Ø x H) RECOVERY DISCHARGE TEMP. TEMP. RISE VOLTAGE / PHASE GAS LOAD (BTU/h) # OF STAGES EFF. FUEL INPUT OUTPUT GWH-1 A.O. SMITH BTH-150 DOM. HW 100 28"Ø x 77" 178 GPH 140 °F 100 °F 120 V / 1 NATURAL GAS 150,000 147,000 MODULATING 98% (1) (2) (3) (4) REMARKS: 1. BUILDING DOMESTIC COLD AND HOT WATER. 2. SIMPLEX / AQUA-SENSOR / DELAY CONFIGURATION. 3. PROVIDE WITH FULLY INTEGRATED PROGRAMMABLE ELECTRIONC CONTROLLER, 120 / 24 V TRANSFORMER, FRP TANK, AND CORROSION RESISTANT POSITIVE MOTOR-DRIVEN REGENERATION VALVE. 4. WATER SOFTENER SELECTION SHALL BE BASED ON INCOMING WATER PARAMETERS OF: 19 GPG HARDNESS. WATER SOFTENER SCHEDULE PLAN TAG MANUFACTURER (7) MODEL SERVES DIMENSIONS (D x W x H) FLOWRATE (GPM) PRESSURE DROP (PSI) REMARKS CONTINUOUS PEAK CONTINUOUS PEAK WS-1 CULLIGAN CTM-120 (1) 50 x 20 x 85 55 GPM 73 GPM 15 25 (2) (3) (4) REMARKS: 1. DUCTED 4-PIPE FAN COIL UNIT. 2. SUPPORT FAN COIL UNIT FROM STRUCTURE UTILIZING NEOPRENE SPRING VIBRATION ISOLATORS. 3. PROVIDE WITH UNIT MOUNTED DISCONNECT. 4. PROVIDE WITH 2" FILTER. 5. PROVIDE WITH 2 ROW COIL. FAN COIL SCHEDULE GENERAL PHYSICAL SIZE FAN MOTOR ELECTRICAL COOLING COOLING COIL HEATING HEATING COIL PLAN TAG MFR. MODEL TYPE REMARKS DIMENSIONS (D x W x H) WEIGHT TOTAL AIRFLOW E.S.P. (in-wg) HP TYPE VOLTAGE / PHASE CAPACITY (BTU/h) WATERSIDE PERFORMANCE AIRSIDE PERFORMANCE PARAMETE RS CAPACITY (BTU/h) WATERSIDE PERFORMANCE AIRSIDE PERFORMANCE PARAMET ERS TOTAL SENSIBLE FLOW FLUID EWT / LWT TEMPERATURES DB / WB | (EAT | LAT) MAX PRES. DROP FLOW FLUID EWT / LWT TEMPERATURES (DB) (EAT / LAT) MAX PRES. DROP FLUID FLUID FC-110 DAIKIN BCHD0081 (1) (2) (3) (4) (5) 29" x 18" x 43" 290 lb 700 CFM 0.5 0.5 hp ODP 208 V / 1 26748.0 Btu/h 19028.0 Btu/h 6 GPM 30% GLYCOL 45 °F / 55 °F 80 °F / 67 °F | 55 °F / 55 °F 6.7 FT 15,282 2 GPM 30% GLYCOL 140 °F / 110 °F 65 °F / 85 °F 8.9 FT REMARKS: 1. DRAINABLE LOUVER WITH 6" STATIONARY, 37.5°, EXTRUDED ALUMINUM BLADES WITH .081" WALL THICKNESS. 2. PROVIDE WITH 70% PVDF FINISH. CUSTOM COLOR TO BE SELECTED BY ARCHITECT DURING THE SUBMITTAL PHASE. 3. PROVIDE WITH INTERNAL BIRD SCREEN. 4. PROVIDE WITH EXTENDED SILL. 5. THINLINE LOUVER WITH 1-1/2" STATIONARY, 30°, EXTRUDED ALUMINUM BLADES WITH .063" WALL THICKNESS. LOUVER SCHEDULE GENERAL PHYSICAL SIZE AIRFLOW OPTIONS PLAN TAG MFR. MODEL SERVES CONFIG. FACE SIZE FREE AREA FREE AREA VELOCITY CFM S.P. DROP REMARKS H W EL-1 RUSKIN ELF6375DX EXHAUST (1) 30" 36" 4 SF 346 FPM 1,400 CFM 0.10" (2) (3) (4) EL-3 RUSKIN ELF375DX - (1) 12" 16" 1 SF 1,500 FPM 1,000 CFM 0.20" (1) (2) IL-1 RUSKIN ELF6375DX INTAKE (1) 24" 24" 2 SF 648 FPM 1,400 CFM 0.10" (2) (3) (4) IL-2 RUSKIN ELF6375DX INTAKE (1) 72" 72" 21 SF 737 FPM 15,750 CFM 0.10" (2) (3) (4) RL-1 RUSKIN ELF6375DX RELIEF (1) 72" 72" 21 SF 562 FPM 12,000 CFM 0.10" (2) (3) (4) RL-2 GREENHECK ESU-153 RETURN (5) 36" 72" 13 SF 397 FPM 5,000 CFM 0.01" (2) RL-3 GREENHECK ESU-153 RETURN (5) 36" 72" 13 SF 853 FPM 10,750 CFM 0.07" (2) NATURAL GAS USAGE TABLE METER EQP. TAG GAS LOAD (BTU/h) #1 MAIN BUILDING METER B-1 1,000,000 GENERATOR 2,000,000 GWH-1 150,000 RH-109-A 40,000 RH-109-B 40,000 RH-130-A 40,000 RH-130-B 40,000 RH-130-C 40,000 Grand total: 8 3,350,000 1 1 AD DE ND UM 1 4/ 15 /2 02 2 TERMINAL EXPANSION KEARNEY REGIONAL AIRPORT (EAR) KEARNEY, NEBRASKA AIP 3-31-0045-036 (CARES) ADDENDUM NO. 1 Attachment No. 5 Revised Plan Sheets (Electrical) Sheets E0.2, E2.1, E3.1, E6.2 and E7.2 GT 1 60 11 1 60 14 1 60 19 1 60 20 G AS1 G AS2 E LE C2 E LE C2 2 13 0. 17 2 12 9. 94 2 12 9. 96 2 12 9. 59 EXISTING HANGAR BUILDING nP SEE SHEET E0.0 FOR GENERAL ELECTRICAL NOTES 'LS' 'ATS-LS' 'MDP' 'ATS-DPOS' 'M' 'D' 'T' 'N' E4.1 3 PROVIDE (2) 3" UNDERGROUND CONDUITS. INTERCEPT BORED CONDUITS PROVIDED BY CIVIL CONTRACTIOR, SEE CIVIL SHEETS FOR CONDUIT BORING LOCATIONS. PROVIDE ONE (1) 3-CELL MAXCELL INNERDUCT IN EACH 3" CONDUIT FROM DATA ROOM TO PULLBOX. PROVIDE 24" X 36" IN-GRADE COMMUNICATIONS BOX, COORDINATE INSTALLATION LOCATION WITH UTILTIES AND CIVIL PLANS. INSTALL BOX ALONG EXISTING FIBER PATHWAY AND INTERCEPT EXISTING CONDUITS INTO NEW BOX. 3 E0.2 PROVIDE (1) 4" PRIMARY CONDUIT UNDERGROUND. INTERCEPT BORED CONDUIT PROVIDED BY CIVIL CONTRACTOR AND EXTEND TO NPPD SERVICE LOCATION PER NPPD SPECIFICATIONS. COORDINATE WITH NPPD PRIOR TO INSTALLATION FOR EXACT LOCATION AND ADDITIONAL REQUIREMENTS. NEW NPPD PAD MOUNTED TRANSFORMER FIELD COORDINATE FINAL LOCATION WITH OWNER AND CIVIL ENGINEER. NEW GENERATOR 2 E0.2 2 E0.2 +(20' - 0") S1[a] S1[a] S2A[a] 'EM' (E) 'N2'EXISTING PHONE AND FIBER SERVICE PROVIDER PEDESTAL. 'OS' (#10 WIRE) (#10 WIRE) (#10 WIRE) APPROXIMATE LOCATION OF EXISTING NPPD 3-PHASE SERVICE. COORDINATE EXACT LOCATION WITH NPPD AND CIVIL ENGINEER. 10 E5.1 4 E0.2 PROVIDE UNDERGROUND SECONDARY CONDUIT AND WIRE PER ELECTRICAL RISER DIAGRAM ON SHEET E6.2 SEE CIVIL DRAWINGS FOR BOLLARDS LOCATION E011 2[a] (M-41,43) 5 E0.2 EXISTING ANTENNA TOWER ACCH-1 2 E0.2 S1 (#10 WIRE) E011 PROVIDE (1) 4" PRIMARY CONDUIT UNDERGROUND. INTERCEPT BORED CONDUIT PROVIDED BY CIVIL CONTRACTOR AND EXTEND TO NPPD PAD MOUNTED TRANSFORMER PER NPPD SPECIFICATIONS. COORDINATE WITH NPPD PRIOR TO INSTALLATION FOR EXACT LOCATION AND ADDITIONAL REQUIREMENTS. (TYP.) E016 SECURITY FENCE, SEE CIVIL DRAWINGS 1 1 1 1 GRADE GROUND CLAMP 6 #6 REBARS VERT. WITH #4 REBARS 12" O.C. HORIZ. 5/8" X 10' COPPER CLAD GROUND 24 " #12 (MIN.) TO FIXTURE HEAD(S) PHASE CONDUCTORS PER PLAN IN-LINE FUSE - EACH PHASE POLE (SEE SCHEDULE) 3/4" CHAMFER BASE COVER TO MATCH POLE ANCHOR BOLTS FURNISHED WITH POLE 24" ROUND CONCRETE BASE ATTACH CONDUCTOR FROM GROUND ROD AND GROUND WIRE FROM CIRCUIT TO GROUND LUG ON POLE CURB 30 " #6 BARE SPLICE HANDHOLE 72 " 24" (WHERE APPLICABLE) BRANCH CIRCUIT WITH EQUIPMENT GROUNDING CONDUCTOR IN CONDUIT PER PLAN COMPACTED EARTH #4 REBAR CONTINUOUS AROUND SERVICE BOX CONCRETE ENCASEMENT QUAZITE PC STYLE STACKABLE COMPOSITE SERVICE BOXES WITH TRAFFIC COVER OR EQUAL #4 REBAR CONTINUOUS AROUND SERVICE BOX 12" 8" 36 " M IN IM U M 8" CRUSHED ROCK AROUND BOTTOM OF PULLBOX PVC CONDUIT(S) PER PLANS GENERAL REQUIREMENTS: A. CONTRACTOR SHALL VERIFY CATALOG NUMBERS AND INSTALLATION REQUIREMENTS PRIOR TO ORDERING. NOTIFY ENGINEER OF ANY CONFLICTS WITH PROPOSED INSTALLATION. B. POLE TYPE DESCRIPTION: SSS = SQUARE STRAIGHT STEEL STS = SQUARE TAPERED STEEL RSS = ROUND STRAIGHT STEEL RTS = ROUND TAPERED STEEL SSA = SQUARE STRAIGHT ALUMINUM STS = SQUARE TAPERED STEEL RSA = ROUND STRAIGHT ALUMINUM RTA = ROUND TAPERED ALUMINUM C. PROVIDE EACH POLE WITH MATCHING METAL BASE COVER AND FACTORY-INSTALLED INTERNAL VIBRATION DAMPENERS. D. PROVIDE POLES AND BASE COVER WITH 3MM POWDER COATED FINISH TO MATCH LUMINAIRE OVER EPOXY PRIME COAT (VALMONT V-PRO 30 OR EQUAL). SITE LIGHTING SCHEDULE NOTES: 1. LUMINAIRE SHALL BE CONSIDERED EQUAL AS MANUFACTURED BY: ACUITY BRANDS, HUBBELL, COOPER, OR PHILIPS LIGHTING. 2. MOUNT FIXTURE AT HANDRAIL HEIGHT ON THE EXISTING ANTENNA TOWER. BRANCH CIRCUIT CONDUIT PROVIDED AS PART OF TOWER INSTALLATION. 48 " M IN + MIN. CONDUIT BEND RADIUS 36" MIN - 2" & 3" 48" MIN - 4", 5", & 6" 60" MIN - 6" EPOXY 4"-6" COMPACTED CRUSHED ROCK / GRAVEL COIL EXCESS CONDUCTOR IN BASEMENT CONDUITS WITH INSULATED BUSHINGS OR BELL END 4" MAX. BEFORE BOTTOM OF BOX PAD BASE. PRIMARY SECONDARY ENTRY AREA ENTRY AREA LEAVE EMPTY NOTES: 1. MINIMUM CLEARANCE AROUND PAD BACK = 36" SIDES = 36" FRONT = 120" (FOR HOT STICK MAINTENANCE) PAD LOCATIONS MUST ALSO MEET NATIONAL ELECTRICAL CODE. ARTICLE 450-27 AND NATIONAL ELECTRICAL SAFETY CODE, SECTION 15, ARTICLE 152-A2. REFER TO SECTION D OF ESRM OR THE DISTRIBUTION DESIGN MANUAL FOR GUIDELINES REGARDING OUTDOOR LOCATION OF OIL INSULATED EQUIPMENT NEAR BUILDINGS. 2. TRANSFORMERS LOCATED IN AREAS EXPOSED TO VEHICULAR TRAFFIC SHALL BE PROTECTED WITH SUITABLE PIPE OR "I" BEAMS ON ALL EXPOSED SIDES SUPPLIED AND INSTALLED BY THE CUSTOMER AS PER DISTRIBUTION CONSTRUCTION STANDARD XXX (ESRM SECTION C) CONDUIT PRIMARY 4" NON-METALLIC CONDUIT(S) WITH 90° BENDS, 1" SEPARATION FOR PRIMARY CABLE. SECONDARY MAX. NO. CONDUCTORS: 500KVA SIX (6) PER PHASE MAX. NO. CONDUCTORS: ≥ 500KVA EIGHT (8) PER PHASE MAX. CONDUCTOR SIZE: 750 KCMIL SECONDARY CONDUIT MAY ONLY BE PLACED IN THE SECONDARY ENTRY AREA FINAL GRADE 17" 26" 58" 18" 3. CUSTOMER TO FURNISH ALL CONDUIT BEYOND THE POINT OF DELIVERY. CONDUIT TO BE ELECTRICAL GRADE. PRIMARY CONDUIT ELBOWS OR BENDS TO BE AS SPECIFIED BY NPPD. 4. CONDUITS INSTALLED TO THE POINT OF DELIVERY SHALL INCLUDE A PULL ROPE OR TWINE WITH A BREAK STRENGTH RATING OF AT LEAST 300 LBS. 5. SERVICE CONDUCTORS SHALL EXTEND AT LEAST SIX (6) FEET ABOVE THE MOUNTING SURFACE OF THE PAD. 6. NPPD TO SPECIFY TRANSFORMER SIZE. 7. CRUSHED ROCK / GRAVEL BASE MUST BE COMPACTED PRIOR TO SETTING THE BOX PAD. 3" MIN. (TYP.) 4-#4 X 24" REBARS CONDUIT STUB-UP AREA, VERIFY LOCATION WITH REVIEWED GENERATOR SHOP DRAWINGS LE N G T H + 12 " 3/4" CHAMFER ALL AROUND 1. COORDINATE PAD WITH GENERATOR SUPPLIED. ALLOW ANY REQUIRED INSPECTIONS BEFORE, DURING AND AFTER CONSTRUCTION OF PAD. 2. LOCATION AND DIMENSIONS OF SLOT AND CONDUITS MUST BE MAINTAINED IN RELATION TO OVERALL SLAB DIMENSIONS. 3. VERIFY PAD DIMENSIONS FROM REVIEWED SHOP DRAWINGS. 10 " WIDTH +12" #8 - 6 x 6 STEEL MESH 3" MIN. (TYP.) NOTES: #8 - 6 x 6 STEEL MESH m o e y rr Is s e n g I n e e r I n g I n c m e c h a n ic a l | e le c tr ic a l | te c h n o lo g y | c o m m is s io n in g 4 9 4 0 N o rt h 1 1 8 th S tr e e t O m a h a , N E 6 8 1 6 4 P : 4 0 2 .4 9 1 .4 1 4 4 w w w .m o rr is s e y e n g in e e ri n g .c o m M E I P R O J E C T # : Progress Print NOT TO BE USED FOR CONSTRUCTION date morrissey engineering, inc. SHEET NO. DATE PROJECT KEARNEY TERMINAL SEAL NO . RE VI SI ON S DA TE CIVIL ENGINEER DR AW N BY : DE SI GN ED BY : RE VI EW ED BY : QU AN TI TI ES CH EC KE D BY : ARCHITECT CONSULTANT K E A R N E Y R E G IO N A L A IR P O R T T E R M IN A L E X P A N S IO N K E A R N E Y , N E B R A S K A 2 0 3 7 1 03/11/2022 3/28/2022 E0.2 EL EC TR IC AL SI TE P LA N SCALE:N 1" = 20'-0"E0.2 1 ELECTRICAL SITE PLAN SITE LIGHTING SCHEDULE MARK DESCRIPTION MANUFACTURER CATALOG NUMBER BEAM DIST. LIGHT SOURCE ELECTRICAL FINISH QTY. PER POLE POLE SPEC. ACCEPTABLE MANUFACTURERS REMARKSSPEC. CCT TYPE LOAD VOLTS TYPE HEIGHT S1 AREA LIGHT - TYPE 3 - SINGLE HEAD, BUY AMERICA LITHONIA DSX1 LED P9 30K T3M MVOLT RPA DNAXD HS BAA III 25,000 LM 3000K LED 241 W 208 V ALUMINUM 1 RTS 40' - 0" NOTE 1 S2A AREA LIGHT - TYPE 3 - WALL MOUNT, BUY AMERICA LITHONIA DSX0 LED P6 30K T3M MVOLT WBA DNAXD HS BAA III 14,000 LM 3000K LED 134 W 208 V ALUMINUM -- -- NOTE 1 SCALE: NOT TO SCALEE0.2 2 30" POLE BASE DETAIL SCALE: NOT TO SCALEE0.2 3 IN-GRADE PULLBOX DETAIL SCALE: NOT TO SCALEE0.2 4 NPPD TRANSFORMER PAD DETAIL KEYNOTES E011 COORDINATE BORING WORK UNDER EXISTING DRIVE WITH CIVIL ENGINEER. SEE CIVIL DRAWINGS FOR ADDITIONAL INFORMATION AND SCOPE CLARIFICATION. E016 LOCATE LUMINAIRES IN GREEN SPACE LOCATED ON THE SECURE SIDE OF SECURITY FENCE. COORDINATE EXACT LOCATION OF LUMINAIRES WITH CIVIL AND LANDSCAPING DRAWINGS. SEE LIGHTNG PLAN ON SHEET E1.1 FOR CIRCUITING AND LUMINAIRE TYPE INFORMATION. SCALE: NOT TO SCALEE0.2 5 GENERATOR PAD 1 AD DE ND UM 1 4/ 15 /2 02 2 L ADA GATE L B IN S EM PTY B IN S EM PTY BINS EMPTY L3 P R O VISIO N 2 AIT2 ENTER EXIT ETD 2 24 SS ETD STSO TAB LE630 2 TDC/CAT TDC/CAT S M ITH S D E TE C TIO N H I- S C A N 6 0 4 0 C TiX P C 1 AVS WTMD CEIA TAB LE630 2 2 3'- 9" 3' 3 5 . 00 0 0 2 4 . 00 0 0 3 5 . 00 0 0 2 4 . 00 0 0 0 . 0 00 0 0 . 0 00 0 S T S T M M M S S S S G T M CR CR CR CR CR CR TV S S S S PT PT PT PT CR PT PT PT PT PT CR CR J TV S S S M M J S S S S PT S J PT PT CR CRCR PT TV TV TV TV TV TV M CR CR CR PT CR PT CRPT PTCR S S CR PT S S S CR S CO NO₂ J J M J J M CO NO₂ S J J JJ J J J M M S J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J PP PP TV PP PP PP PP PP S S S M M MM M CR CR TV TV TV PT KP S S PT M PT CR SS TV CR PT PT CR S TV SS S S J J J JJ S S S J TT TV V PP PP CRPT S PP SEE SHEET E0.0 FOR GENERAL ELECTRICAL NOTES G ,4 4" RH-130-A RH-130-B RH-130-C TCP 'LS' 'MDP' 'ATS-DPOS' 'M' 'T''D' 'S' ACCH-1 ACCU-136 ACCU-133 G,44" G,44" 44" 96" AC-133 FACP E4.1 1 AC-136 1"C. FOR CONNECTIVITY 1 E5.1 E201 1"C. 'DPOS' 108" 108" 108" 108" MECHANICAL 128 AIRPORT STORAGE 130 AIRLINE OFFICE 125 AIRLINE WORK AREA 124 TSA DATA 136 MAIN DATA 133 PRIVATE SCREENING ROOM 142 TSA BAG SCREENING 132 OUTBOUND BAGGAGE 131 TICKET COUNTER 121 TSA STORAGE 137 TSA OFFICE 140 TSA BREAK ROOM 138 TSA WORK AREA 134 TSA CHECKPOINT 141 BOARDING 144 DEPARTURES LOBBY 101 WAITING 102 AIRLINE BREAK AREA 123 TSA LOCKERS 135 SECURE HOLDROOM SOUTH 143 AIRLINE STORAGE 122 ALCOVE 126 E4.1 3 132" 132" 46" 78" 48" 48" 6-20,120" 6-20,120"6-20,120" 12 0" E202 E203 (TYP OF 3) E4.1 6 108" FBE4 FBE4 96"E204 FBE6A T-1,3 E205 FBE4 FBE8A T-4,6,8,10 T-2 (#10) T-5 T-7 T-12 T-9 E206 132" 132" 132" 132" 132" 132" 132" 126" 126" 126" 108" 84" E207 E207 E207 E208 E208 120" 120" 120" 120" 120" 96" 96" 48" G,WP,24" 30/2/NF/3R 30/2/NF/3R 108" 156" 48" 108" H H H H H H H H H H H H H H H H H H S-1,3E209 (TYP.) 2 E5.1 72" 72" H 72" 72" 72" 72" 72" (TYP.)E210 132" (TYP.) 5 E5.1 96" 96" 96" 114" 144" 144"144" GEF-1 H (TYP.) 9 E5.1 (TYP.) E212 (TYP.)E212 E213 TO ABOVE M-2 M-3 M-4 M-1 M-7 M-6 M-5 VENTILATION CONTROL PANEL (TYP.)E215 E220 M-8 S-2 S-4 G ,4 4" 60" 60" S-8 S-9 S-7 44" S-6 S-10 S-11 S-13 S-12 S-15 S-29 T-20 E219 E218 E218 E219 D-16,18 (2#10. #8G.,3/4"C.) T-19,21 (2#10. #8G.,3/4"C.) E218 E218 E219 E219 T-23 T-24 T-26 S-5 48" G,48" M-10 M-11 G,48" G,48" 36" 36" T-25 T-22 G,WP,24" G,WP,24" G,WP,24" MDP-2 (4#250 KCMIL,1#4G.,3"C.) E220 S-26 M-27 M-16 T-28, TSA WORK AREA 134 T-27 (PART.) T-35 S-28 T-27 (PART.) T-29 S-25 S-30 S-27 S-31 S-35 OS-20 MEZZANINE ACCESS 120 'OS' DPOS-8 (4#2,#8G.,1-1/2"C.) BAGGAGE SYSTEM MCP S-33 T-32 G,WP,24" T-31 WAP FBE4 FBE4 FBE4 FBE4 120" M-33 192" 192" W P ,3 6" TO 'MDP' E224 E225E225 E225E225 E225E225 G,WP,24" G,WP,24" E226 M-34,36,38,G (3#6,#10G.,1"C.) T-34 M-39 38"E228 E227 E228 E4.1 7 48" E227 M-23 M-15 M-21 M-17 M-19 M-25 (TYP.) E229 M-14 M-18 M-20 E230 E230 EF-2 T-33 E220 ALTERNATE BID: SEE SHEET E4.1 FOR ALTERNATE BID INFORMATION FOR AREA WITHIN DASHED LINES. REMOVE POWER CONNECTIONS TO DOORS, RADIANT HEATERS, AND CARD READER. ELECTRICAL DEVICES IN AREA TO BE WEATHERPROOF RATEDED FOR EXTERIOR. (TYP.) E234 M-37 M-35 T-30 T-16,18 (#10) T-37 L6-30 FBE4 FBE4 FBE4 FBE4 FBE4 FBE4 FBE4 S-23 G,48" 6-20 6-20 6- 20 6- 20 6- 20 6- 20 S-22,24 S-18,20S-14,16 (TYP.)E229 AIRPORT SUPPLY 153 LS-1 OS-8 G,WP,24" G,WP,24" M-12 E232 E232 T-38,G 78" 44" T-39 1 1 1 36" 48" 44" G,44" G,44" G,44" G,44" 48" G,44" G,48" 24" 24" 24" 24" 'N' 84" 84" 84" E2.1 3 36" 36" CUSTODIAL 111 VENDING NON-SECURE 103 VENDING SECURE 146 CUSTODIAL 147 RENTAL OFFICE 107 RENTAL DESK 106 SECURITY 112 INBOUND BAGGAGE 109 BAGGAGE CLAIM 110 SECURE HOLDROOM NORTH 145 LOUNGE 104 FAA EQUIPMENT 108 RESTROOM 116 HALLWAY 113 RESTROOM 115 RESTROOM 117 RESTROOM 151 RESTROOM 152 HALLWAY 148 RESTROOM 150 RESTROOM 149 ARRIVALS LOBBY 105 VESTIBULE AIRSIDE 110V VESTIBULE LANDSIDE 105V 48" 48" G,44" 48" 44" G,48" (MEZZANINE) 126" 132" AREA OF BUILDING BEING DESIGNED AS PART OF SEPARATE PROJECT FAAP 108" 48" 48" 126" 132" 126" G,WP,24" 132" CUH-105V RH-109-A RH-109-B EFT-110 CUH-110V FC-110 H H H H H 108" 117" (TYP.) 2 E5.1 72" 78" 132" 126" 96" 126" (TYP.) 5 E5.1 (TYP.) 9 E5.1 120" 23" 23" 23" 23" N-25 N-27 N-24 N-26 N-29 N2-15,17 (2#12,#10G.,1/2"C.) N-4 N-5N-3 23" 23" 23" 23" N-9 N-6 44" N-17 N-12 OS-7OS-12 OS-10 OS-5 MEZZANINE ACCESS 120 N-19 N-14 N-21 OS-1 E216 E216 OS-9 44" OS-2 OS-11 OS-4 OS-6 OS-13 OS-14 N-16 N-7 N-18 E217 N-23 N2-2 N-20 N-22 E217 N2-5 60" 44" 44" N2-1 N2-8 G,48" G,48" N2-9 G,48" G,48" G,48" N2-10 N2-7 N2-6 'N2' N2-3 OS-3 N2-18,20,22 (3#6,#10G.,1'C.) BAGGAGE SYSTEM MCP 2 N2-11,13 108" 108" 108" G,48" 3D 48" 'LS2' GENERATOR ANNUCIATOR PANEL TO 'MDP' E224 WP,36" E225 E225 E225 E225 48" E227 E217 FIRE SUPPRESSION AIR COMPRESSOR EM-(20/1) E235 'EM' (E) FBE4 FBE4 FBE4 FBE4 44"44" AIRPORT SUPPLY 153 G,44" G,44" OS-8 E231 E222 48" G,WP,24" FAAP (TYP.)E222 4 ROOF ACCESS HATCH MECHANICAL M101 EF-1 AHU-2 60/3/NF/3R 60/3/NF/3R OS-25,27,29 (4#8,#10G.,3/4"C.) OS-28,30,32 (4#6,#10G.,1"C.) G,WP,24" 44" N-1 OS-22,24,26 (4#10,#10G.,3/4"C.) VFD-RLF-1 RLF-1 TO BELOW TCP OS-19 OS-18 UH-M101 OS-17 AHU-1 OS-16 E217 44"44" 44" TSA COORDINATION NOTE 1. THE GENERAL CONTRACTOR SHALL COORDINATE WITH THE "SYSTEMS INTEGRATOR" CONTRACTOR (TSA APPROVED EQUIPMENT CONTRACTOR, SEE PROJECT MANUAL). 60 CALENDAR DAYS IN ADVANCE OF THE COMPLETION OF PHASE 1 FOR THE RELOCATION OF THE EXISTING TSA SCREENING EQUIPMENT (INCLUDING BODY SCANNERS, LUGGAGE SCANNERS, ETC.) FROM THE EXISTING TERMINAL BUILDING (PHASE 2) TO THE NEW TERMINAL EXPANSION (PHASE 1). SCHEDULE AND SEQUENCE OF EQUIPMENT RELOCATION WORK SHALL BE COORDINATED WITH AIRPORT PERSONNEL AND COMPLETED OUTSIDE BUSINESS HOURS TO ENSURE NO INTERRUPTION OF AIRLINE SERVICES. THE GENERAL CONTRACTOR WILL NEED TO INCLUDE COSTS TO COORDINATE WITH, AS WELL AS COMPLETE ALL REQUIRED WORK, WITH THE SYSTEM INTEGRATOR CONTRACTOR. 2. CONTRACTORS SHALL COORDINATE WITH TSA, AND THE TSA PROVIDED CONTRACTOR, 60 CALENDAR DAYS IN ADVANCE OF THE COMPLETION OF PHASE 1 FOR THE RELOCATION OF THE EXISTING TSA SCREENING EQUIPMENT (INCLUDING BODY SCANNERS, LUGGAGE SCANNERS, ETC.) FROM THE EXISTING TERMINAL BUILDING (PHASE 2) TO THE NEW TERMINAL EXPANSION (PHASE 1). THE TSA WILL COMPLETE THE RELOCATION OF THE EXISTING TSA SCREENING EQUIPMENT (WITH THEIR OWN CONTRACTOR). NO COSTS SHALL BE INCLUDED IN THE CONTRACTOR’S BID FOR THE RELOCATION OF THE EXISTING TSA SCREENING EQUIPMENT (COSTS COVERED BY OTHERS). THE EQUIPMENT RELOCATION WORK SHALL BE COMPLETED AT NIGHT BY THE TSA, JUST PRIOR TO PUTTING PHASE 1 BUILDING AREAS INTO SERVICE, TO ENSURE NO INTERRUPTION OF AIRLINE SERVICES. m o e y rr Is s e n g I n e e r I n g I n c m e c h a n ic a l | e le c tr ic a l | te c h n o lo g y | c o m m is s io n in g 4 9 4 0 N o rt h 1 1 8 th S tr e e t O m a h a , N E 6 8 1 6 4 P : 4 0 2 .4 9 1 .4 1 4 4 w w w .m o rr is s e y e n g in e e ri n g .c o m M E I P R O J E C T # : Progress Print NOT TO BE USED FOR CONSTRUCTION date morrissey engineering, inc. SHEET NO. DATE PROJECT KEARNEY TERMINAL SEAL NO . RE VI SI ON S DA TE CIVIL ENGINEER DR AW N BY : DE SI GN ED BY : RE VI EW ED BY : QU AN TI TI ES CH EC KE D BY : ARCHITECT CONSULTANT K E A R N E Y R E G IO N A L A IR P O R T T E R M IN A L E X P A N S IO N K E A R N E Y , N E B R A S K A 2 0 3 7 1 03/11/2022 3/28/2022 E2.1 PO W ER P LA NS KEYNOTES E201 TIME CLOCK LOCATION. COORDINATE FINAL INSTALLATION LOCATION WITH TSA PRIOR TO ROUGH-IN AND INSTALLATION OF POWER AND DATA OUTLETS. E202 PROVIDE 2-GANG DEEP JUNCTION BOX FOR VIDEO DISPLAY WITH 2-GANG RING. PROVIDE 1-1/4"C. FROM BOX TO ABOVE NEAREST ACCESSIBLE CEILING. PROVIDE INSULATED BUSHINGS ON CONDUIT END. E203 PROVIDE RECEPTACLE CONNECTIONS FOR VIDEO DISPLAY. CONNECT STACKED RECEPTACLES TO THE CIRCUIT INDICATED AT THE END OF EACH COLUMN OF STACKED DEVICES. COORDINATE FINAL INSTALLATION LOCATIONS AND QUANTITIES WITH APPROVED VIDEO WALL SHOP DRAWINGS. E204 RECEPTACLE FOR DURESS ALARM REPEATER, COORDINATE FINAL LOCATION AND HEIGHT WITH TSA PRIOR TO ROUGH-IN AND INSTALLATION. E205 RECEPTACLE FOR DURESS ALARM RECEIVER, COORDINATE FINAL LOCATION AND HEIGHT WITH TSA PRIOR TO ROUGH-IN AND INSTALLATION. E206 PROVIDE HARDWIRED ELECTRICAL CONNECTION FOR TSA EQUIPMENT. COORDINATE FINAL ROUGH-IN REQUIREMENTS WITH TSA PRIOR TO ROUGH-IN AND INSTALLATION. E207 INSTALL RECEPTACLE AND TV DATA OUTLET ON BACKSIDE OF TV MOUNT. CONCEAL ELECTRICAL CONDUIT IN EXTENSION COLUMN. E208 INSTALL RECEPTACLE AND DATA OUTLET IN CASEWORK. COORDINATE INSTALLATION LOCATION WITH CASEWORK ELEVATION AND APPROVED CASEWORK SHOP DRAWINGS. E209 PROVIDE ELECTRICAL CONNECTION TO REVOLVING DOOR. COORDINATE INSTALLATION LOCATION DOOR MANUFACTURER. E210 PROVIDE 1/2" CONDUIT BETWEEN SPEAKER LOCATIONS AND 1/2"C. FROM LAST SPEAKER LOCATION TO ABOVE ACCESSIBLE CEILING. E212 PROVIDE JUNCTION BOX AND ELECTRICAL CONNECTION AT MOTORIZED SHADES IN CURTAIN WALL MULLION. ELECTRICAL CONTRACTOR TO INSTALL LEAD FURNISHED BY SHADE CONTRACTOR FROM SHADE MOTOR TO ELECTRICAL JUNCTION BOX. PROVIDE TWO CONNECTIONS AT EACH JUNCTION BOX LOCATION. COORDINATE CONNECTION LOCATION WITH APPROVED SHADE MANUFACTURER SHOP DRAWINGS. CONCEAL JUNCTION BOX AND CONDUITS FROM VIEW BEHIND ROLLER SHADE MOTORIZED HOUSING, CONDUITS VISIBLE WILL NEED TO BE REINSTALLED, HIDDEN FROM VIEW. E213 PROVIDE ELECTRICAL CONNECTION TO ADA OPERATOR. COORDINATE INSTALLATION LOCATION WITH DOOR HARDWARE VENDOR. E215 PROVIDE ROUGH-IN FOR THERMOSTAT/SENSOR(S). PROVIDE 1/2"C. WITH PULL STRING FROM ROUGH-IN TO MECHANICAL EQUIPMENT SERVED, COORDINATE REQUIREMENTS WITH MECHANICAL CONTRACTOR PRIOR TO ROUGH-IN. E216 LOCATE RECEPTACLE FOR MECHANICAL EQUIPMENT SO THAT CORD AND PLUG ARE CONCEALED INSIDE OR BEHIND UNIT. COORDINATE INSTALLATION HEIGHT WITH MECHANICAL CONTRACTOR AND ARCHITECTURAL ELEVATION PRIOR TO ROUGH-IN. PROVIDE 20A, 1-POLE GFCI TYPE CIRCUIT BREAKER. E217 MECHANICAL EQUIPMENT PROVIDED WITH INTEGRAL DISCONNECT / VFD. COORDINATE EXACT LOCATION WITH MECHANICAL CONTRACTOR. SEE MECHANICAL SCHEDULES FOR ADDITIONAL INFORMATION. E218 PROVIDE 1/2"C. FOR CONTROL WIRING BETWEEN INDOOR AND OUTDOOR UNIT. ROUTE WITH REFRIGERANT PIPING. E219 2#12,#12G-1/2"C. FOR POWER CONNECTION FROM INDOOR UNIT TO OUTDOOR UNIT. E220 MECHANICAL EQUIPMENT PROVIDED WITH INTEGRAL DISCONNECT / VFD. COORDINATE EXACT LOCATION WITH MECHANICAL CONTRACTOR. SEE MECHANICAL SCHEDULES FOR ADDITIONAL INFORMATION. E222 SAW CUT FLOOR AS REQUIRED FOR INSTALLATION OF FLOOR BOX(ES) AND CONDUIT(S). CUT, PATCH AND REPAIR FLOOR TO MATCH SURROUNDING FLOOR. ROUTE CONDUIT(S) UP INTO NEW WALL AND STUBBED INTO ADJACENT NETWORK ROOM. E224 PROVIDE CAST BOX FOR FUTURE NEMA 4, 100A, 208V, 3P, PIN AND SLEEVE RECEPTACLE FOR ELECTRIC HEATING CART. PROVIDE WEATHERPROOF COVERPLATE AND 1-1/2" CONDUIT WITH PULL STRING ROUTED BACK TO 'MDP'. E225 PROVIDE ROUGH-IN AND CONDUIT AND WIRING TO OVERHEAD DOOR SENSOR THAT OPENS/CLOSES DOOR AUTOMATICALLY BASED ON MOTION. SENSOR PROVIDED BY OTHERS. COORDINATE REQUIREMENTS WITH OVERHEAD DOOR MANUFACTURER. E226 PROVIDE CAST BOX AND NEMA 4, 60A, 208V, 3P, PIN AND SLEEVE RECEPTACLE FOR DEICER. COORDINATE REQUIREMENTS WITH OWNER EQUIPMENT. E227 PROVIDE SINGLE GANG JUNCTION BOX WITH 1"C. TO ABOVE NEAREST ACCESSIBLE CEILING FOR SHADE CONTROLLER. PROVIDE INSULATED BUSHING ON CONDUIT END. E228 PROVIDE THREE GANG JUNCTION BOX WITH 1"C. TO ABOVE NEAREST ACCESSIBLE CEILING FOR SHADE CONTROLLER. PROVIDE INSULATED BUSHING ON CONDUIT END. E229 PROVIDE SINGLE GANG JUNCTION BOX WITH 3/4"C. TO ABOVE NEAREST ACCESSIBLE CEILING WHERE SHOWN. PROVIDE 3/4"C. BETWEEN JUNCTION BOX LOCATIONS INDICATED. PROVIDE INSULATED BUSHINGS ON CONDUIT ENDS. E230 PROVIDE WEATHER RATED JUNCTION BOX AND COVER ABOVE ROOF FOR WINDOW SHADE SENSOR LOCATION. PROVIDE 1/2"C. FROM JUNCTION BOX TO ABOVE WINDOW SHADE CONTROLLER LOCATION IN MAIN DATA ROOM. PROVIDE 16/2 AWG WIRE FROM SENSOR LOCATION TO MAIN CONTROLLER. COORDINATE JUNCTION BOX LOCATION AND INSTALLATION HEIGHT WITH WINDOW SHADE MANUFACTURER. COORDINATE ROOF PENETRATION WITH ROOFING MANUFACTURER. E231 INSTALL DEVICE ON LOWER BULKHEAD. E232 EXHAUST FAN 'GEF-1' IS CONTROLLED BY VENTINLATION CONTROL PANEL. INTERLOCK EXHUAST FAN AND MOTORIZED DAMPER(S) SUCH THAT THE DAMPER(S) OPENS UPON OPERATION OF EXHAUST FAN. SEE MECHANICAL DRAWINGS FOR MORE INFORMATION. ALL CONTROL WIRING SHALL BE PROVIDED BY THE MECHANICAL CONTRACTOR. COORDINATE INSTALLATION OF EXHAUST FAN SYSTEM WITH MECHANICAL CONTRACTOR. E234 SEE CIVIL DRAWINGS FOR PROTECTIVE BOLLARDS LOCATIONS AROUND ELECTRICAL AND MECHANICAL EQUIPMENT AS REQUIRED. E235 PRE-ACTION FIRE SPRINKLER SYSTEM. PROVIDE ELECTRICAL CONNECTION TO AIR COMPRESSOR. CONNECT TO EXISTING CIRCUIT BREAKER LEFT SPARE DURING DEMOLITION. COORDINATE EXACT ELECTRICAL CONNECTION, LOCATION, AND ADDITIONAL REQUIREMENTS WITH FIRE PROTECTION CONTRACTOR AND EQUIPMENT MANUFACTURER. SCALE:N NOT TO SCALEE2.1 1 FIRST FLOOR - POWER - AREA A SCALE:N NOT TO SCALEE2.1 2 FIRST FLOOR - POWER - AREA B SCALE:N 1/8" = 1'-0"E2.1 3 ROOF & MEZZANINE PLAN - POWER 1 AD DE ND UM 1 4/ 15 /2 02 2 L ADA GATE L B IN S EM PTY B IN S EM PTY BINS EMPTY L3 P R O VISIO N 2 AIT2 ENTER EXIT ETD 2 24 SS ETD STSO TAB LE630 2 TDC/CAT TDC/CAT S M ITH S D E TE C TIO N H I- S C A N 6 0 4 0 C TiX P C 1 AVS WTMD CEIA TAB LE630 2 2 3'- 9" 3' 3 5 . 00 0 0 2 4 . 00 0 0 3 5 . 00 0 0 2 4 . 00 0 0 0 . 0 00 0 0 . 0 00 0 G T M CR CR CR CR CR CR TV F F F F F F PT PT PT PT CR PT PT PT PT PT CR CR J F F TV F F F F F F M M J J PT J PT PT CR CRCR PT TV TV TV TV TV TV M CR CR CR PT CR PT CRPT PTCR R CR PT CR F F F F F F J F J JJ J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J F F F F F F F F F PP PP TV PP PP PP PP PP M M MM M CR CR TV TV TV F PT KP F F F F FF F PT M PT CR F F F CR PT PT CR R R TV F F F F F F J F F J J JJF TV F F F F PP PP CRPT F F RR PP SEE SHEET E0.0 FOR GENERAL ELECTRICAL NOTES 2D E4.1 2 E4.1 4 2D(T) FACP 0D 2D(T) 2D(T),1V(T) 2D(T) 2D(T) 2D(CT),1D 2D(CT) FIRE SERVICE WAP WAPWAP WAP WAP WAP (TYP.)E302 (TYP.)E304 (TYP.)E303 E305 4D 4D 4D SITE SERVICE CONDUITS, SEE SITE PLAN 2D(T),1C(T) 2D(T) VENDING NON-SECURE 103 MECHANICAL 128 AIRPORT STORAGE 130 AIRLINE OFFICE 125 AIRLINE WORK AREA 124 TSA DATA 136 MAIN DATA 133 PRIVATE SCREENING ROOM 142 TSA BAG SCREENING 132 OUTBOUND BAGGAGE 131 TICKET COUNTER 121 TSA STORAGE 137 TSA OFFICE 140 TSA BREAK ROOM 138 TSA WORK AREA 134 TSA CHECKPOINT 141 BOARDING 144 DEPARTURES LOBBY 101 WAITING 102 AIRLINE BREAK AREA 123 TSA LOCKERS 135 SECURE HOLDROOM SOUTH 143 AIRLINE STORAGE 122 ALCOVE 126 BOARDING 144 WAITING 102 4D 4D 4D 4D WAP E309 E320 1D 1D 2D(T) 2D(T) WATER SERVICE 4D 2D(T) 2D(T) 4D(T) 1V(T) 4D(CT) 6D(CT) WAP WAP WAP WAP WAP WAP 2D 2D 2D 2D 2D 2D 1D 1D H H H H H H H H H H H H H H H H H E324 E323 A A B C A C A B A B C A C B B B B A (TYP.) 6 E5.1 WAP E325 WAP E325 2D(T) 2D(T) 2D(T) C H (3) 4" (3) 4" (3) 4" E321 (1) 4" E320 (2) 4" E320 (1) 4" E320 (3) 4" E320 (1) 2" (2) 2" (2) 2" (2) 4" (2) 4" E320 H E326 2D 2D(T) H WAP E320 E320 1D 1D (TYP.) E330 E329 1D E329 (TYP.)E330 0D (3) 4" 2D(T) 1V(T) 1V(T) 2D(T) E326 E335 (VIDEO WALL) E306 ALTERNATE BID: SEE SHEET E4.1 FOR ALTERNATE BID INFORMATION FOR AREA WITHIN DASHED LINES. REMOVE FIRE ALARM DEVICES AND CARD READER. (TYP.)E336 2D(T),1C(T) 1D (VIDEO WALL) 2D(T) 2D(T) 1 1 2D 2D 2D WAP WAP WAP WAP WAP WAP WAP (TYP.)E302 (TYP.)E304 4D 2D 1D VENDING NON-SECURE 103 SECURE HOLDROOM NORTH 145 HALLWAY 113 HALLWAY 148 CUSTODIAL 111 VENDING SECURE 146 CUSTODIAL 147 R E N T A L O F F IC E 1 0 7 RENTAL DESK 106 SECURITY 112 INBOUND BAGGAGE 109 BAGGAGE CLAIM 110 LOUNGE 104 FAA EQUIPMENT 108 RESTROOM 116 RESTROOM 115 RESTROOM 114 RESTROOM 117 RESTROOM 151 RESTROOM 152 RESTROOM 150 RESTROOM 149 ARRIVALS LOBBY 105 VESTIBULE AIRSIDE 110VVESTIBULE LANDSIDE 105V F A A P AREA OF BUILDING BEING DESIGNED AS PART OF SEPARATE PROJECT E320 2D FAAP 3D 3D WAP WAP WAP WAP E323E323 H H H H H E324 E324 B B C C C A B B (TYP.) 6 E5.1 2D B A C C (4) 2" (3) 4" 2D E334 2D (3) 4"(3) 4" EXISTING FAA RACKS 4 H 6 E5.1 2D E306 ACCESS HATCH AHU-1 AHU-2 (TYP.)E337 TSA COORDINATION NOTE 1. THE GENERAL CONTRACTOR SHALL COORDINATE WITH THE "SYSTEMS INTEGRATOR" CONTRACTOR (TSA APPROVED EQUIPMENT CONTRACTOR, SEE PROJECT MANUAL). 60 CALENDAR DAYS IN ADVANCE OF THE COMPLETION OF PHASE 1 FOR THE RELOCATION OF THE EXISTING TSA SCREENING EQUIPMENT (INCLUDING BODY SCANNERS, LUGGAGE SCANNERS, ETC.) FROM THE EXISTING TERMINAL BUILDING (PHASE 2) TO THE NEW TERMINAL EXPANSION (PHASE 1). SCHEDULE AND SEQUENCE OF EQUIPMENT RELOCATION WORK SHALL BE COORDINATED WITH AIRPORT PERSONNEL AND COMPLETED OUTSIDE BUSINESS HOURS TO ENSURE NO INTERRUPTION OF AIRLINE SERVICES. THE GENERAL CONTRACTOR WILL NEED TO INCLUDE COSTS TO COORDINATE WITH, AS WELL AS COMPLETE ALL REQUIRED WORK, WITH THE SYSTEM INTEGRATOR CONTRACTOR. 2. CONTRACTORS SHALL COORDINATE WITH TSA, AND THE TSA PROVIDED CONTRACTOR, 60 CALENDAR DAYS IN ADVANCE OF THE COMPLETION OF PHASE 1 FOR THE RELOCATION OF THE EXISTING TSA SCREENING EQUIPMENT (INCLUDING BODY SCANNERS, LUGGAGE SCANNERS, ETC.) FROM THE EXISTING TERMINAL BUILDING (PHASE 2) TO THE NEW TERMINAL EXPANSION (PHASE 1). THE TSA WILL COMPLETE THE RELOCATION OF THE EXISTING TSA SCREENING EQUIPMENT (WITH THEIR OWN CONTRACTOR). NO COSTS SHALL BE INCLUDED IN THE CONTRACTOR’S BID FOR THE RELOCATION OF THE EXISTING TSA SCREENING EQUIPMENT (COSTS COVERED BY OTHERS). THE EQUIPMENT RELOCATION WORK SHALL BE COMPLETED AT NIGHT BY THE TSA, JUST PRIOR TO PUTTING PHASE 1 BUILDING AREAS INTO SERVICE, TO ENSURE NO INTERRUPTION OF AIRLINE SERVICES. m o e y rr Is s e n g I n e e r I n g I n c m e c h a n ic a l | e le c tr ic a l | te c h n o lo g y | c o m m is s io n in g 4 9 4 0 N o rt h 1 1 8 th S tr e e t O m a h a , N E 6 8 1 6 4 P : 4 0 2 .4 9 1 .4 1 4 4 w w w .m o rr is s e y e n g in e e ri n g .c o m M E I P R O J E C T # : Progress Print NOT TO BE USED FOR CONSTRUCTION date morrissey engineering, inc. SHEET NO. DATE PROJECT KEARNEY TERMINAL SEAL NO . RE VI SI ON S DA TE CIVIL ENGINEER DR AW N BY : DE SI GN ED BY : RE VI EW ED BY : QU AN TI TI ES CH EC KE D BY : ARCHITECT CONSULTANT K E A R N E Y R E G IO N A L A IR P O R T T E R M IN A L E X P A N S IO N K E A R N E Y , N E B R A S K A 2 0 3 7 1 03/11/2022 3/28/2022 E3.1 SP EC IA L S YS TE M S P LA NS KEYNOTES E302 PROVIDE (1) CATEGORY 6A DATA CABLE TO EACH WIRELESS ACCESS POINT. PROVIDE 30' SERVICE LOOP. TERMINATE WITH PLENUM RATED SURFACE BOX MOUNTED ABOVE ACCESSIBLE CEILING. PROVIDE 3' PATCH CORD FOR CONNECTION TO OWNER-FURNISHED WIRELESS ACCESS POINT. E303 PROVIDE (2) CATEGORY DATA CABLES FOR EACH TELEVISION LOCATION, UNLESS OTHERWISE INDICATED. E304 PROVIDE (1) CATEGORY DATA CABLE FOR CONNECTION TO POE SECURITY CAMERA. PROVIDE 20' SERVICE LOOP. TERMINATE WITH PLENUM RATED SURFACE BOX MOUNTED ABOVE ACCESSIBLE CEILING. PROVIDE 3' PATCH CORD FOR CONNECTION TO SECURITY CAMERA (CAMERA BY OWNER SECURITY VENDOR). E305 PROVIDE (2) CATEGORY DATA CABLES FOR CONNECTION TO FACP. TERMINATE WITH MODULAR JACK IN FACP. EXTEND CABLES TO ABOVE SERVICE PROVIDER DEMARC, COIL CABLES AND LEAVE UN-TERMINATED. E306 PROVIDE (2) CATEGORY DATA CABLES FOR CONNECTION TO BUILDING AUTOMATION SYSTEM PANEL. TERMINATE WITH MODULAR JACK. VERIFY PANEL LOCATION PRIOR TO INSTALLATION. E309 FIRE ALARM CONTRACTOR TO PROVIDE MONITORING OF FLOW AND TAMPER SWITCHES AT FIRE ALARM RISER. VERIFY LOCATION AND QUANTITY OF SWITCHES REQUIRED WITH FIRE SPRINKLER CONTRACTOR PRIOR TO ROUGH-IN. E320 PROVIDE HILTI CP 653 SPEED SLEEVE (OR EQUAL BY STI), MECHANICAL FIRESTOP DEVICE FOR WALL PENETRATIONS. PROVIDE SIZE AND QUANTITY INDICATED ADJACENT TO KEYNOTE, (TYP) E321 PROVIDE HILTI CS-SL SA SMOKE AND ACOUSTIC SLEEVE (OR EQUAL BY STI), FOR WALL PENETRATIONS. PROVIDE SIZE AND QUANTITY INDICATED ADJACENT TO KEYNOTE, (TYP) E323 PROVIDE REMOTE CLOSED CONTACT FOR LOCAL LOCKDOWN AND PROGRAMMED SCHEDULING OF DOOR INDICATED. E324 PROVIDE FIRE ALARM RELAY AT CONTROLLER OF DOOR INDICATED, COORDINATE FINAL LOCATION WITH DOOR MANUFACTURER. RELAY SHALL RELEASE DOOR WHEN A FIRE ALARM EVENT IS TRIGGERED. COORDINATE PROGRAMMING WITH DOOR MANUFACTURER. E325 PROVIDE (1) CATEGORY DATA CABLE TO EACH WIRELESS ACCESS POINT. PROVIDE 30' SERVICE LOOP. TERMINATE WITH PLENUM RATED SURFACE BOX MOUNTED ABOVE PLATFORM OF TSA OFFICES. PROVIDE 3' PATCH CORD FOR CONNECTION TO OWNER-FURNISHED WIRELESS ACCESS POINT. E326 INSTALL DATA CABLES BETWEEN FLOOR BOXES INDICATED, CABLING DOES NOT NEED TO TERMINATE TO DATA RACK. E329 PROVIDE (1) CATEGORY DATA CABLE BETWEEN WINDOW SHADE PANEL AND FIRST CONTROLLER. TERMINATE WITH MODULAR JACK AT SHADE CONTROL DATA HUB. PROVIDE 1' PATCH CORD TO CONNECTION DATA HUB. E330 PROVIDE CATEGORY DATA CABLE CONNECTION BETWEEN DATA HUB LOCATIONS. TERMINATE WITH CRIMP-ON RJ-45 JACKS ON EACH END. COORDINATE EXACT LOCATION WITH SHADE INSTALLER PRIOR TO INSTALLATION. E334 PROVIDE SMOKE DETECTOR TIED INTO PRE-ACTION SUPPRESSION SYSTEM. E335 PROVIDE 16/4 CABLE FROM X-RAY ALARM MONITORING POINT TO BUILDING LEO ALARM HEADEND LOCATION. COORDINATE INSTALLATION LOCATIONS WITH TSA AND XRAY EQUIPMENT MANUFACTURER. COORDINATE FINAL WIRING TYPE WITH TSA AND X-RAY EQUIPMENT MANUFACTURER. E336 MOUNT DEVICE TO BOTTOM OF STRUCTURE. CONCEAL CONDUIT / CABLING IN STRUCTURE / ABOVE CEILING. E337 DUCT SMOKE DETECTOR(S) AND RELAY. PROVIDE DUCT MOUNTED SMOKE DETECTOR, FAN SHUTDOWN RELAY, REMOTE INDICATOR, CONTROLS CONNECTIONS FOR SHUT-DOWN, AND CONNECTION TO FIRE ALARM CONTROL PANEL. SHUT DOWN OF UNIT SHALL BE FROM DUCT DETECTOR ALARM. LOCATE REMOTE INDICATOR ON ADJACENT WALL IN ROOM. SCALE:N 1/8" = 1'-0"E3.1 1 FIRST FLOOR - SPECIAL SYSTEMS - AREA A SCALE:N 1/8" = 1'-0"E3.1 2 FIRST FLOOR - SPECIAL SYSTEMS - AREA B SCALE:N 1/8" = 1'-0"E3.1 3 ROOF & MEZZANINE PLAN - SPECIAL SYSTEMS ALTERNATE NO. 5: PROVIDE COMMUNICATIONS DEVICES, CABLING, WIRING, RACKS, ETC. SHOWN ON THIS PLAN AND IDENTIFIED IN SPECIFICATION SECTION 271500. BASE BID TO PROVIDE ROUGH-INS AND PATHWAYS. ALTERNATE NO. 6: PROVIDE SECURITY AND ACCESS CONTROL DEVICES, CABLING, WIRING, PROGRAMMING, ETC. SHOWN ON THIS PLAN AND IDENTIFIED IN SPECIFICATION SECTION 281000, 281100, 281300, 282300. BASE BID TO PROVIDE ROUGH-INS AND PATHWAYS. ALTERNATE NO. 7: PROVIDE AUDIO VISUAL DEVICES, CABLING, WIRING, PROGRAMMING, ETC. SHOWN ON THIS PLAN AND IDENTIFIED IN SPECIFICATION SECTION 274134. BASE BID TO PROVIDE ROUGH-INS AND PATHWAYS. 1 AD DE ND UM 1 4/ 15 /2 02 2 M PANEL M PANEL LS PANEL LS PANEL D PANEL D PANEL T PANEL T PANEL N PANEL N PANEL 80 0/ 3 60 /3 S PANEL S PANEL EM EXIST. PANEL EM EXIST. PANEL OS PANEL OS PANEL N2 PANEL N2 PANEL LS2 PANEL LS2 PANEL 2 3 1 4 5 6 7 8 9 J 250 KW NATURAL GAS GENERATOR (SEE 263213) POWER CO. PAD MOUNT TRANSFORMER 208/120V, 3 PHASE, 4WIRE ATS-DPOSATS-LS MDP 1200A,3PH, 4W DPOS 800A,3PH, 4W M E C H A N IC A L 12 8 A LC O V E 1 26 M IA N D A T A 1 33 T S A D A T A 1 36 C U S T O D IA L 11 1 F A A E Q U IP M E N T 1 06 E X T E R IO R GRADE 60-4 60-4 60-4 800-4 200-4 200-4 100-4 200-4100-4 100-4 TO AHU-1 TO AHU-2 40-46 0- 4 M E Z Z A N IN E A C C E S S 1 20 400-410 E5.1 SPD SPD SPD SPD SPDSPD (TYP.) E401 SPD E402 E403 1200-4S E404 E405 IN D O O R B A G G A G E 1 09 SPD 100-4 SPD E402 E405 40-4 E406 E40610 E5.1 10 E5.1 E408 E407 E410E411 E412 E409 CONVENIENCE RECEPTACLE ENGINE HEATER BATTERY CHARGER M - 68,70,72 (#10 WIRE,#10G,1-1/4"C.) E413 TO ACCH-1 250-4 E414 SPDSPD 7 E5.1 E415 E416 E416 E416 SPD SEE SHEET E0.0 FOR GENERAL ELECTRICAL NOTES m o e y rr Is s e n g I n e e r I n g I n c m e c h a n ic a l | e le c tr ic a l | te c h n o lo g y | c o m m is s io n in g 4 9 4 0 N o rt h 1 1 8 th S tr e e t O m a h a , N E 6 8 1 6 4 P : 4 0 2 .4 9 1 .4 1 4 4 w w w .m o rr is s e y e n g in e e ri n g .c o m M E I P R O J E C T # : Progress Print NOT TO BE USED FOR CONSTRUCTION date morrissey engineering, inc. SHEET NO. DATE PROJECT KEARNEY TERMINAL SEAL NO . RE VI SI ON S DA TE CIVIL ENGINEER DR AW N BY : DE SI GN ED BY : RE VI EW ED BY : QU AN TI TI ES CH EC KE D BY : ARCHITECT CONSULTANT K E A R N E Y R E G IO N A L A IR P O R T T E R M IN A L E X P A N S IO N K E A R N E Y , N E B R A S K A 2 0 3 7 1 03/11/2022 3/28/2022 E6.2 EL EC TR IC AL R ISE R DI AG RA M & SC HE DU LE S Notes: G – GFCI type circuit breaker. L – Locking handle type circuit breaker. Options: SPACE -- -- 1 29 ... 30 1 -- -- SPACE SPACE -- -- 1 27 ... 28 SPACE -- -- 1 25 ... 26 2 20 -- SPARE SPARE -- 20 1 23 ... 24 1 20 -- SPARE SPARE -- 20 1 21 ... 22 1 20 -- SPARE SPARE -- 20 1 19 ... 20 1 20 -- SPARE LTG - GATEWAY 20 1 17 ... 18 SHADE CONTROLLER 20 1 15 ... 16 2 25 AC-133 / ACCU-133 13 ... 14 PWR - MAIN DATA 138 20 2 11 ... 12 2 20 PWR - MAIN DATA 138 9 ... 10 PWR - MAIN DATA 138 20 2 7 ... 8 2 20 PWR - MAIN DATA 138 REC - MAIN DATA 138 20 1 5 ... 6 1 20 REC - MAIN DATA 138 REC - MAIN DATA 138 20 1 3 ... 4 1 20 REC - MAIN DATA 138 REC - MAIN DATA 138 20 1 1 ... 2 1 20 REC - MAIN DATA 138 Circuit Description OPT R P CKT A B C CKT P R OPT Circuit Description INTEGRAL SPD Type: MLO W/GND. BAR A.I.C. Rating: Mounting: SURFACE Wire: 4 Rating: 100 A Phase: 3 Panel: D Voltage: 120/208 LIGHTING PANEL SCHEDULE Notes: G – GFCI type circuit breaker. S – Shunt trip type circuit breaker. L – Locking handle type circuit breaker. N – New circuit breaker. Options: 17 ... 18 1 -- -- SPACE 15 ... 16 1 -- -- SPACEPANEL 'LS2' 30 3 13 ... 14 1 -- -- SPACE SPARE -- 20 1 11 ... 12 1 20 -- SPARE SPARE -- 20 1 9 ... 10 1 20 -- SPARE SPARE -- 20 1 7 ... 8 1 20 -- SPARE LTG - EXIT SIGNS 20 1 5 ... 6 1 20 -- SPARE LTG - SOUTH EM. 20 1 3 ... 4 1 20 LTG - DEPARTURES EM. FACP 20 1 1 ... 2 1 20 LTG - DEPART. EXTERIOR EM Circuit Description OPT R P CKT A B C CKT P R OPT Circuit Description Type: MLO W/GND. BAR A.I.C. Rating: FUSED Mounting: SURFACE Wire: 4 Rating: 60 A Phase: 3 Panel: LS Voltage: 120/208 FUSED COORDINATION PANEL SCHEDULE Notes: G – GFCI type circuit breaker. L – Locking handle type circuit breaker. Options: 83 ... 84 81 ... 82 HWP-2 (VIA VFD-HWP-2) - MECHANICAL 128 20 3 79 ... 80 3 15 CWP-2 (VIA VFD-CWP-2) - MECHANICAL 128 77 ... 78 75 ... 76 HWP-1 (VIA VFD-HWP-1) - MECHANICAL 128 20 3 73 ... 74 3 15 CWP-1 (VIA VFD-CWP-1) - MECHANICAL 128 SPARE -- 20 1 71 ... 72 1 20 -- GENERATOR CHARGER SPARE -- 20 1 69 ... 70 1 20 -- GENERATOR HEATER SPARE -- 20 1 67 ... 68 1 20 -- REC - GENERATOR SPARE -- 20 1 65 ... 66 SPARE -- 20 1 63 ... 64 SPARE -- 20 1 61 ... 62 3 20 -- SPARE SPARE (G) -- 20 1 59 ... 60 1 -- -- SPACE SPARE (G) -- 20 1 57 ... 58 1 -- -- SPACE SPACE -- -- 1 55 ... 56 1 -- -- SPACE SPACE -- -- 1 53 ... 54 1 -- -- SPACE SPACE -- -- 1 51 ... 52 1 -- -- SPACE SPACE -- -- 1 49 ... 50 1 -- -- SPACE SPACE -- -- 1 47 ... 48 1 -- -- SPACE SPACE -- -- 1 45 ... 46 1 -- -- SPACE 43 ... 44 1 20 -- SPARE LTG - TARMAC AREA POLES 20 2 41 ... 42 1 20 -- SPARE ZP-101 - RADIANT HEATPUMP 20 1 39 ... 40 1 20 -- SPARE REC - ENGINE BLOCK HEATER 20 1 37 ... 38 REC - ENGINE BLOCK HEATER 20 1 35 ... 36 REC - OVERHD DOOR SENSOR 20 1 33 ... 34 3 60 G PWR - AIRPORT STOR. DEICER REC - MECHANICAL 128 20 1 31 ... 32 1 20 L PWR - BOILER EM. PWR OFF REC - MECHANICAL 128 20 1 29 ... 30 1 20 MOTOR - MECHANICAL 128 WEST WINDOW SHADES 20 1 27 ... 28 1 20 HVAC - MECHANICAL 128 WEST WINDOW SHADES 20 1 25 ... 26 1 20 PWR - MECHANICAL 128 WEST WINDOW SHADES 20 1 23 ... 24 1 20 HVAC - MECHANICAL 128 WEST WINDOW SHADES 20 1 21 ... 22 1 20 HVAC - MECHANICAL 128 WEST WINDOW SHADES 20 1 19 ... 20 1 20 EAST WINDOWS SHADES WEST WINDOW SHADES 20 1 17 ... 18 1 20 EAST WINDOWS SHADES WEST WINDOW SHADES 20 1 15 ... 16 1 20 EAST WINDOW SHADES SPARE -- 20 1 13 ... 14 1 20 EAST WINDOW SHADES REC - OUTBOUND BAGGAGE 20 1 11 ... 12 1 20 REC - SOUTH EXTERIOR REC - MECHANICAL 128 20 1 9 ... 10 1 20 REC - OUTBOUND BAGGAGE RH-130-C - BAG. 131 20 1 7 ... 8 1 20 GEF-1 - OUTGOING BAGGAE VENT. CNTRL PNL - OUT. BAG. 20 1 5 ... 6 1 20 GARAGE OPENER E. - BAG. 131 GARAGE OPENER W. - STOR. 20 1 3 ... 4 1 20 GARAGE OPENER S. - BAG. 131 GARAGE OPENER E. - STOR. 20 1 1 ... 2 1 20 RH-130 A & B - STOR. 130 Circuit Description OPT R P CKT A B C CKT P R OPT Circuit Description INTEGRAL SPD, 2-SECTION Type: MLO W/GND. BAR A.I.C. Rating: 22000 Mounting: SURFACE Wire: 4 Rating: 200 A Phase: 3 Panel: M Voltage: 120/208 LIGHTING PANEL SCHEDULE Notes: G – GFCI type circuit breaker. L – Locking handle type circuit breaker. Options: SPACE -- -- 1 41 ... 42 1 -- -- SPACE SPACE -- -- 1 39 ... 40 1 -- -- SPACE SPACE -- -- 1 37 ... 38 1 -- -- SPACE SPARE -- 20 1 35 ... 36 1 -- -- SPACE SPARE -- 20 1 33 ... 34 1 20 -- SPARE LTG - NORTH HOLDROOM 20 1 31 ... 32 1 20 -- SPARE REC - SINK RESTROOM 149 G 20 1 29 ... 30 1 20 -- SPARE REC - SINK RESTROOM 114 G 20 1 27 ... 28 1 20 -- SPARE REC - RESTROOM 114, 115 20 1 25 ... 26 1 20 G REC - SINK RESTROOM 150 CUH-105V - VEST. LANDSIDE 20 1 23 ... 24 1 20 G REC - SINK RESTROOM 115 REC - SECURE HOLDRM NOR. 20 1 21 ... 22 1 20 CUH-110V - VEST. AIRSIDE FB - SECURE HOLDRM NORTH 20 1 19 ... 20 1 20 MTR - VEST. AIRSIDE DOORS MICROWAVE VEND. SECURE G 20 1 17 ... 18 1 20 DR OPER. - VEST. LANDSIDE LTG - ROOFTOP LIGHTING 20 1 15 ... 16 1 20 REC - LOUNGE 104 LTG - NORTH FLOODLIGHTS 20 1 13 ... 14 1 20 REC - SECURE HOLDRM NOR. LTG - EXTERIOR SIGNAGE 20 1 11 ... 12 1 20 G MICROWAVE VEND. SECURE REC - VENDING SECURE 146 G 20 1 9 ... 10 1 20 LTG - MECHANICAL (M101) REC - CUSTODIAL 111 20 1 7 ... 8 1 20 LTG - SOUTH FLOODLIGHTS REC - VENDING SECURE 146 G 20 1 5 ... 6 1 20 REC - SECURITY 112 REC - VENDING SECURE 146 G 20 1 3 ... 4 1 20 REC - VENDING SECURE 146 EF-1 20 1 1 ... 2 1 20 LTG - LOUNGE/CORRIDOR Circuit Description OPT R P CKT A B C CKT P R OPT Circuit Description INTEGRAL SPD Type: MLO W/GND. BAR A.I.C. Rating: 22000 Mounting: SURFACE Wire: 4 Rating: 100 A Phase: 3 Panel: N Voltage: 120/208 LIGHTING PANEL SCHEDULE Notes: G – GFCI type circuit breaker. L – Locking handle type circuit breaker. Options: SPACE -- -- 1 59 ... 60 1 20 -- SPARE SPACE -- -- 1 57 ... 58 SPACE -- -- 1 55 ... 56 2 20 SECURED GATE VIDEO CKT #7 53 ... 54 SPARE -- 20 2 51 ... 52 2 20 SECURED GATE VIDEO CKT #6 SPARE -- 20 1 49 ... 50 SPARE -- 20 1 47 ... 48 2 20 SECURED GATE VIDEO CKT #5 SPARE (G) -- 20 1 45 ... 46 SPARE (G) -- 20 1 43 ... 44 2 20 SECURED GATE VIDEO CKT #4 LTG - TSA CHECKPOINT 20 1 41 ... 42 LTG - DEPARTURES LOBBY 20 1 39 ... 40 2 20 SECURED GATE VIDEO CKT #3 LTG - OUTBOUND BAGGAGE 20 1 37 ... 38 FB - SECURE HOLDROOM 20 1 35 ... 36 2 20 SECURED GATE VIDEO CKT #2 DISPOSAL BREAK AREA 123 G 20 1 33 ... 34 REC - SECURE HLDRM SOUTH 20 1 31 ... 32 2 20 SECURED GATE VIDEO CKT #1 REC - AIRLINE STORAGE 122 20 1 29 ... 30 1 20 REC - BOARDING 144 REC - SECURE HLDRM SOUTH 20 1 27 ... 28 1 20 REC - WAITING 102 REC - SECURE HLDRM SOUTH 20 1 25 ... 26 1 20 REC - WAITING 102 REC - WAITING 102 20 1 23 ... 24 LTG - EXTERIOR MULLIONS 20 1 21 ... 22 2 20 CONCOURSE VIDEO CKT #3 LTG - CHECKPOINT / HOLDRM 20 1 19 ... 20 LTG - TSA SUPPORT 20 1 17 ... 18 2 20 CONCOURSE VIDEO CKT #2 ADA OPER. - DEPART. LOBBY 20 1 15 ... 16 REC - TICKET COUNTER 121 20 1 13 ... 14 2 20 CONCOURSE VIDEO CKT #1 REC - TV TICKET COUNTER 121 20 1 11 ... 12 1 20 REC - TICKET COUNTER 121 REC - MICROWAVE - BREAK G 20 1 9 ... 10 1 20 REC - TV TICKET COUNTER 121 REC - COUNTER BREAK 123 20 1 7 ... 8 1 20 G REC - MICROWAVE BREAK 123 REC - AIRLINE WORK AREA 124 20 1 5 ... 6 1 20 G REC - FRIDGE BREAK 123 3 ... 4 1 20 REC - AIRLINE WORK AREA 124 REVOLVING DOOR 20 2 1 ... 2 1 20 REC - AIRLINE OFFICE 125 Circuit Description OPT R P CKT A B C CKT P R OPT Circuit Description INTEGRAL SPD, 1-SECTION, Type: MLO W/GND. BAR A.I.C. Rating: 22000 Mounting: SURFACE Wire: 4 Rating: 200 A Phase: 3 Panel: S Voltage: 120/208 LIGHTING PANEL SCHEDULE Notes: G – GFCI type circuit breaker. L – Locking handle type circuit breaker. Options: SPARE -- 20 1 59 ... 60 1 -- -- SPACE SPARE -- 20 1 57 ... 58 1 -- -- SPACE SPARE -- 20 1 55 ... 56 1 -- -- SPACE SPARE -- 20 1 53 ... 54 1 -- -- SPACE SPARE -- 20 1 51 ... 52 1 -- -- SPACE SPARE (G) -- 20 1 49 ... 50 1 -- -- SPACE 47 ... 48 1 -- -- SPACE SPARE -- 30 2 45 ... 46 1 -- -- SPACE SPACE -- -- 1 43 ... 44 1 -- -- SPACE SPACE -- -- 1 41 ... 42 1 -- -- SPACE REC - TSA CHECKPOINT 137 20 1 39 ... 40 1 -- -- SPACE REC - TSA SVS / ETD MACHINE 20 1 37 ... 38 1 20 G REC - TSA BREAK ROOM 133 REC - TSA OFFICE 20 1 35 ... 36 1 20 HVAC - TSA DATA SAS EF-2 - TSA BREAKROOM 20 1 33 ... 34 1 20 RADIENT HEAT MANIFOLD REC - TSA DATA 140 20 1 31 ... 32 1 20 G DISPOSAL - TSA BREAK RM 133 REC - TSA CHECKPOINT 137 20 1 29 ... 30 1 20 REC - TSA STORAGE 141 REC - TSA DURESS ALARM 20 1 27 ... 28 1 20 REC - TSA DATA 140 REC - TSA WORK AREA 134 20 1 25 ... 26 1 20 REC - TSA WORK AREA 134 REC - TSA BREAK ROOM 133 20 1 23 ... 24 1 20 G REFRIG. - TSA BREAK RM 133 21 ... 22 1 20 REC - TSA BREAK ROOM 133 AC-136/ACCU-136 25 2 19 ... 20 1 20 FB -TSA PVS MACHINE REC - TSA DATA RACK 20 1 17 ... 18 REC - TSA DATA RACK 20 1 15 ... 16 2 30 PWR - TSA EDS MACHINE REC - TSA OFFICE 135 20 1 13 ... 14 1 20 REC - TSA OFFICE 135 REC - TSA OFFICE 135 20 1 11 ... 12 1 20 FB - TSA CHECKPOINT AVS (C) REC - TSA CHECKPOINT (D) 20 1 9 ... 10 1 20 FB - TSA CHECKPOINT (B) FB - TSA CHCKPOINT TDC2 (G) 20 1 7 ... 8 1 20 FB - TSA CHECKPOINT (B) FB - TSA CHCKPOINT TDC1 (G) 20 1 5 ... 6 1 20 FB - TSA CHECKPOINT (B) FB - TSA CHECKPOINT (A) 20 1 3 ... 4 1 20 FB - TSA CHECKPOINT (B) FB - TSA CHCKPOINT XRAY (A) 20 1 1 ... 2 1 30 FB - TSA CHCKPOINT XRAY (B) Circuit Description OPT R P CKT A B C CKT P R OPT Circuit Description 1-SECTION, INTEGRAL SPD Type: MLO W/GND. BAR A.I.C. Rating: 22000 Mounting: SURFACE Wire: 4 Rating: 200 A Phase: 3 Panel: T Voltage: 120/208 LIGHTING PANEL SCHEDULE 1. THE CURRENT LIMITING PLUG IN THE CIRCUIT BREAKER OR THE BREAKER ITSELF MUST BE THE NEXT LOGICAL SIZE ABOVE THE SERVICE CONDUCTOR SIZE. 2. A PERMANENT "RED" ENGRAVED PHENOLIC PLATE MUST BE INSTALLED ON OR ABOVE THE MAIN CIRCUIT BREAKER WITH THE FOLLOWING INFORMATION: a. SERVICE SIZE - PER NEC. b. ALL PROGRAMMED BREAKER SETTINGS. c. "CAUTION - ANY CHANGES TO THESE SETTINGS COULD BE A POTENTIAL RISK TO LIFE AND PROPERTY". 3. PROVIDE AN ARC ENERGY REDUCING MAINTENANCE SWITCH FOR EACH CIRCUIT BREAKER FRAME SIZE 1200 AMPS AND LARGER. Notes: 9 SPD 60 A 3 8 ATS-LS 60 A 3 7 SPACE ONLY 100 A 3 6 SPARE ( ALT #3 / INV-1) 20 A 3 5 SPARE 100 A 3 FUTURE HEATING CART 4 SPARE 100 A 3 FUTURE HEATING CART 3 SPACE ONLY 250 A 3 2 ACCH-1 250 A 3 1 ATS-DPOS 800 A 3 CKT NAMEPLATE DESIGNATION RATING REMARKS Options: INTEGRAL SPD Wires: 4 S.E. Rated: YES Phases: 3 Remarks: MAIN CKT. BKR. W/GND. BAR Volts: 120/208 Panel: MDP Rating: 1200 A A.I.C. Rating: 42000 DISTRIBUTION PANEL SCHEDULE SCALE: NOT TO SCALEE6.2 1 ELECTRICAL RISER DIAGRAM 1. THE CURRENT LIMITING PLUG IN THE CIRCUIT BREAKER OR THE BREAKER ITSELF MUST BE THE NEXT LOGICAL SIZE ABOVE THE SERVICE CONDUCTOR SIZE. 2. A PERMANENT "RED" ENGRAVED PHENOLIC PLATE MUST BE INSTALLED ON OR ABOVE THE MAIN CIRCUIT BREAKER WITH THE FOLLOWING INFORMATION: a. SERVICE SIZE - PER NEC. b. ALL PROGRAMMED BREAKER SETTINGS. c. "CAUTION - ANY CHANGES TO THESE SETTINGS COULD BE A POTENTIAL RISK TO LIFE AND PROPERTY". 3. PROVIDE AN ARC ENERGY REDUCING MAINTENANCE SWITCH FOR EACH CIRCUIT BREAKER FRAME SIZE 1200 AMPS AND LARGER. Notes: 11 SPACE ONLY 100 A 3 10 SPD 60 A 3 9 SPARE 100 A 3 8 OUTBOUND BAGGAGE SYSTEM MCP 100 A 3 7 SPACE ONLY 200 A 3 6 PANEL 'D' 100 A 3 5 SPARE 200 A 3 4 PANEL 'M' 200 A 3 3 PANEL S' 200 A 3 2 PANEL 'T' 200 A 3 1 PANEL 'OS' 400 A 3 100% RATED CIRCUIT BREAKER CKT NAMEPLATE DESIGNATION RATING REMARKS Options: INTEGRAL SPD Wires: 4 S.E. Rated: NO Phases: 3 Remarks: MAIN LUG ONLY W/GND. BAR Volts: 120/208 Panel: DPOS Rating: 800 A A.I.C. Rating: 42000 DISTRIBUTION PANEL SCHEDULE COPPER FEEDER SCHEDULE FEEDER WIRE AND CONDUIT 40-4 4-#8, #8 G - 1"C. 60-4 4-#6, #10 G - 1-1/4"C. 100-4 4-#1, #6 G - 2"C. 200-4 4-#3/0, #6 G - 2-1/2"C. 250-4 4-250 KCMIL, #4 G - 3"C. 400-4 4-600 KCMIL, #3 G - 4"C. 800-4 4-600 KCMIL, #1/0 G IN EACH OF (2) 4"C. 1200-4S 4-600 KCMIL IN EACH OF (3) 4"C. Notes: G – GFCI type circuit breaker. L – Locking handle type circuit breaker. Options: SPACE -- -- 1 41 ... 42 1 -- -- SPACE SPACE -- -- 1 39 ... 40 1 -- -- SPACE SPACE -- -- 1 37 ... 38 1 -- -- SPACE SPACE -- -- 1 35 ... 36 1 -- -- SPACE SPACE -- -- 1 33 ... 34 1 -- -- SPACE SPACE -- -- 1 31 ... 32 1 -- -- SPACE SPACE -- -- 1 29 ... 30 1 -- -- SPACE SPARE -- 20 1 27 ... 28 1 20 -- SPARE SPARE -- 20 1 25 ... 26 1 20 -- SPARE SPARE -- 20 1 23 ... 24 1 20 -- SPARE 21 ... 22 SPARE -- 20 2 19 ... 20 17 ... 18 3 60 INBOUND BAGGAGE SYSTEM MCP FC-110- CUSTODIAL 147 15 2 15 ... 16 1 20 LTG - ARRIVALS LOBBY 105 13 ... 14 1 20 LTG - RENTAL / BAGGAGE EFT-110 - BAGGAGE CLAIM 110 20 2 11 ... 12 1 20 LTG - BAGGAGE CLAIM 110 N. GARAGE DR - INBOUND BAG 20 1 9 ... 10 1 20 REC - INBOUND BAGGAGE E. GARAGE DR- INBOUND BAG. 20 1 7 ... 8 1 20 RH-109-A,RH-109-B - IN. BAG. REC - RENTAL DESK 106 20 1 5 ... 6 1 20 REC - INBOUND BAGGAGE 109 REC - RENTAL DESK 106 20 1 3 ... 4 REC - MONITORS BAG. CLAIM 20 1 1 ... 2 1 20 REC - ARRIVALS LOBBY 105 Circuit Description OPT R P CKT A B C CKT P R OPT Circuit Description Type: MLO W/GND. BAR A.I.C. Rating: 22000 Mounting: SURFACE Wire: 4 Rating: 125 A Phase: 3 Panel: N2 Voltage: 120/208 LIGHTING PANEL SCHEDULE Notes: G – GFCI type circuit breaker. L – Locking handle type circuit breaker. Options: 71 ... 72 69 ... 70PANEL 'EM' 100 3 67 ... 68 3 100 PANEL 'N' SPACE -- -- 1 65 ... 66 SPACE -- -- 1 63 ... 64 SPACE -- -- 1 61 ... 62 3 100 PANEL 'N2' SPACE -- -- 1 59 ... 60 1 -- -- SPACE SPACE -- -- 1 57 ... 58 1 -- -- SPACE SPACE -- -- 1 55 ... 56 1 -- -- SPACE SPACE -- -- 1 53 ... 54 1 -- -- SPACE SPACE -- -- 1 51 ... 52 1 -- -- SPACE SPACE -- -- 1 49 ... 50 1 -- -- SPACE SPACE -- -- 1 47 ... 48 1 -- -- SPACE SPARE -- 20 1 45 ... 46 1 -- -- SPACE SPARE -- 20 1 43 ... 44 1 20 -- SPARE SPARE -- 20 1 41 ... 42 1 20 -- SPARE SPARE -- 20 1 39 ... 40 1 20 -- SPARE SPARE -- 20 1 37 ... 38 1 20 -- SPARE SPARE -- 20 1 35 ... 36 1 20 -- SPARE (G) SPARE -- 20 1 33 ... 34 1 20 -- SPARE (G) SPARE -- 20 1 31 ... 32 29 ... 30 27 ... 28 3 40 AUH-2 AUH-1 20 3 25 ... 26 LTG - WAITING 102 20 1 23 ... 24 LTG - EXTERIOR WALLPACKS 20 1 21 ... 22 3 25 RLF-1 (VFD-RLF-1) TCP-1 - MEZZ. MECH. M101 20 1 19 ... 20 1 20 REC - MEZZ .ACCESS 120 LTG - AUH-2 INTEGRAL LIGHTS 20 1 17 ... 18 1 20 UH-M101 - MEZZ. MECH. M101 LTG - RESTROOMS 20 1 15 ... 16 1 20 LTG - AUH-1 INTEGRAL LIGHTS MICRWAVE VEND. NON-SECUR G 20 1 13 ... 14 1 20 REC - TV VEND. NON-SECURE REC - VEND. NON-SECURE 103 G 20 1 11 ... 12 1 20 G REC - RESTROOM 116 REC - VEND. NON-SECURE 103 G 20 1 9 ... 10 1 20 G REC - RESTROOM 117 REC - RESTROOM 151 G 20 1 7 ... 8 1 20 REC - RESTROOM 117 REC - RESTROOM 152 G 20 1 5 ... 6 1 20 G MICRWAVE VEND. NON-SECUR REC - TV SECURE HOLDRM N 20 1 3 ... 4 1 20 G REC - VEND. NON-SECURE 103 REC - EWC SECURE HLDRM N G 20 1 1 ... 2 1 20 G REC - VEND. NON-SECURE 103 Circuit Description OPT R P CKT A B C CKT P R OPT Circuit Description INTEGRAL SPD, 2-SECTION Type: MLO W/GND. BAR A.I.C. Rating: 22000 Mounting: SURFACE Wire: 4 Rating: 400 A Phase: 3 Panel: OS Voltage: 120/208 LIGHTING PANEL SCHEDULE NOTE: AT CONTRACTOR'S OPTION, COMPACT ELECTRICAL GRADE ALUMINUM CONDUCTORS MAY BE USED FOR FEEDERS 100 AMPS OR LARGER. IF ALUMINUM IS USED, CONTRACTOR TO SIZE ALUMINUM EQUAL TO FEEDER SCHEDULE (COPPER) AS INDICATED ON CONTRACT DOCUMENTS AND SHALL BE SUMBITTED TO ENGINEER FOR REVIEW. Notes: Options: SPACE ONLY -- -- 1 11 ... 12 1 -- -- SPACE ONLY SPACE ONLY -- -- 1 9 ... 10 1 -- -- SPACE ONLY SPACE ONLY -- -- 1 7 ... 8 1 -- -- SPACE ONLY SPARE -- 20 1 5 ... 6 1 20 -- SPARE LTG - MECHANICAL (M101) 20 1 3 ... 4 1 20 -- SPARE LTG - EXTERIOR EGRESS 20 1 1 ... 2 1 20 LTG - NORTH EM. Circuit Description OPT R P CKT A B C CKT P R OPT Circuit Description Type: MLO W/GND. BAR A.I.C. Rating: FUSED Mounting: SURFACE Wire: 4 Rating: 30 A Phase: 3 Panel: LS2 Voltage: 120/208 FUSED COORDINATION PANEL SCHEDULE Notes: G – GFCI type circuit breaker. R – Connect to existing circuit breaker. L – Locking handle type circuit breaker. Options: 41 ... 42 ACCU-108 (AC-108B) - FAA RM -- 25 2 39 ... 40 2 25 -- ACCU-108 (AC-108A) - FAA RM REC - FAA FTI (E) -- 20 1 37 ... 38 1 20 -- REC - FAA FTI (E) REC - TOWER 120V (E) -- 20 1 35 ... 36 1 20 -- REC - ILS RASK (E) REC - AWOS RACK (E) -- 20 1 33 ... 34 1 20 -- REC - RCO RACK (E) 31 ... 32 1 20 -- REC - RCO RACK (E) 29 ... 30SPARE (E) -- 15 3 27 ... 28 25 ... 26 3 15 -- SPARE (E) 23 ... 24SPARE (E) -- 30 3 21 ... 22 SPARE (E) -- 20 1 19 ... 20 3 60 -- SPARE (E) SPARE (E) -- 20 1 17 ... 18 1 20 -- SPARE (E) SPARE (E) -- 20 1 15 ... 16 1 20 -- SPARE (E) REC - TSA COMPUTER RM (E) -- 20 1 13 ... 14 1 20 -- SPARE (E) SPARE (E) -- 20 1 11 ... 12 1 20 -- SPARE (E) PWR - FIRE SUPRESSION SYS R 20 1 9 ... 10 1 20 -- SPARE (E) SPARE (E) -- 20 1 7 ... 8 1 20 -- SPARE (E) SPARE (E) -- 20 1 5 ... 6 1 20 -- SPARE (E) SPARE (E) -- 20 1 3 ... 4 1 20 -- SPARE (E) LTG - EXISTING -- 20 1 1 ... 2 1 20 -- SPARE (E) Circuit Description OPT R P CKT A B C CKT P R OPT Circuit Description Type: MLO W/GND. BAR A.I.C. Rating: EXISTING Mounting: SURFACE Wire: 4 Rating: 125 A Phase: 3 Panel: EM Voltage: 120/208 EXISTING LIGHTING PANEL SCHEDULE KEYNOTES E401 PROVIDE A SURGE PROTECTIVE DEVICE (SPD) INTEGRAL WITH THE EQUIPMENT INDICATED. SEE SPECIFICATIONS. E402 PROVIDE REMOTE SPD MOUNTED TO SIDE OF PANEL (APT # SPDEE OR EQUAL). PROVIDE 30A, 3-POLE CIRCUIT BREAKER FUSE CARTRIDGE IN PANEL AND CONNECT SPD WITH AS SHORT OF LEADS AS POSSIBLE. E403 PROVIDE GENERATOR CONTROL WIRING IN 1" C. TO AUTOMATIC TRANSFER SWITCHES 'ATS-OS' AND 'ATS-LS'. COORDINATE CONTROL WIRING REQUIREMENTS WITH GENERATOR SUPPLIER. E404 INSTALL LITHONIA EMERGENCY BATTERY FIXTURE, CATALOG #EU2L, INSIDE GENERATOR ENCLOSURE. E405 PROVIDE FUSED PANEL BOARD FOR COMPLETE COORDINATION OF THE LIFE SAFETY EMERGENCY BRANCH. SEE SPECIFICATIONS FOR PANEL REQUIREMENTS. E406 3/4"C. WITH CONTROL WIRING TO GENERATOR ANNUNCIATOR AND EMERGENCY POWER OFF PUSHBUTTON. COORDINATE WIRING COUNTS WITH GENERATOR SUPPLIER. ALL GENERATOR CONTROL WIRING SHALL BE STRANDED. E407 PAD MOUNT TRANSFORMER TO BE PROVIDED AND INSTALLED BY NPPD. COORDINATE INSTALLATION REQUIREMENTS WITH POWER COMPANY, SEE SITE PLAN. E408 PROVIDE CTs INSTALLED INTEGRAL TO TRANSFORMER. PROVIDE METER SOCKET MOUNTED TO SIDE OF TRANSFORMER. COORDINATE EQUIPMENT AND INSTALLATION REQUIREMENTS PER POWER COMPANY SPECIFICATIONS. KEYNOTES E409 CONTRACTOR TO PURCHASE AND INSTALL A FIBERCRETE BASEMENT PAD FROM NPPD FOR THE INSTALLATION OF THE NEW TRANSFORMER. COORDINATE REQUIREMENTS WITH NPPD AND CITY OF KEARNEY. E410 GROUND EQUIPMENT PER NPPD SPECIFICATIONS. E411 PROVIDE ONE 4" CONDUIT PER POWER COMPANY SPECIFICATIONS BELOW GRADE FOR INSTALLATION OF POWER COMPANY PRIMARY CONDUCTORS, SEE SITE PLAN. E412 SECONDARY CONDUIT AND WIRING INSTALLED BY ELECTRICAL CONTRACTOR PER POWER COMPANY SPECIFICATIONS, SEE SITE PLAN. E413 CONCRETE PAD PROVIDED BY CIVIL. SEE CIVIL PLANS AND STRUCTURAL DRAWINGS FOR ADDITIONAL INFORMATION. CONCRETE PAD TO REMAIN IN ALTERNATE BID #3 FOR FUTURE GENERATOR. E414 REMOVE EXISTING MAIN CIRCUIT BREAKER FROM PANEL. PROVIDE BLANK IN PANEL BOARD COVER. E415 UNDER ALTERNATE BID #3: REMOVE GENERATOR AND TWO AUTOMATIC TRANSFER SWITCHES. REPLACE WITH CENTRAL BATTERY INVERTER TO POWER LIFE SAFETY E416 UNDER ALTERNATE BID #3: ALL CONDUIT ROUGH-IN TO REMAIN FOR FUTURE GENERATOR AND FUTURE TRANSFER SWITCHES. REMOTE SPD, COORDINATION PANEL, RED COVER REMOTE SPD, COORDINATION PANEL, RED COVER 1 1 AD DE ND UM 1 4/ 15 /2 02 2 TELEVISIONTV CONTROL CABLE 6' HDMI CABLE DISPLAY (TVX) SEE DISPLAY SCHEDULE NETWORK DECODER, CRESTRON # DM-NVX-D30 (MOUNTED BEHIND DISPLAY) PATCH CORD TO OWNER NETWORK (BY DIV. 271500) RACK 'AV' (DATA 133) AV SWITCH, (PROVIDED AS PART OF RACK BUILD OUT) PATCH CORD FROM PATCH PANEL (BY DIV. 271500) DISPLAY SCHEDULE MANUFACTURER (NOTE 1) CATALOG NUMBERMARK DESCRIPTION MOUNTING HARDWARE (NOTE 2) REMARKS TV2 NOTE 4SAMSUNG QB55R SERIES 55" 4K UHD TV NOTES: 1. SIMILAR DISPLAYS FROM PANASONIC, NEC, SHARP, AND LG WILL BE CONSIDERED AS EQUALS. VERIFY COMPATIBILITY OF WALL MOUNT WITH ALTERNATE DISPLAY MANUFACTURER. 2. SIMILAR MOUNTING HARDWARE FROM CHIEF OR PEERLESS WILL BE CONSIDERED AS EQUAL. 3. MOUNT DISPLAY IN PORTRAIT ORIENTATION. 4. PROVIDE (1) CHIEF # LCM3X1U MOUNT AND (2) CUSTOM LENGTH EXTENSION COLUMNS (BLACK) FOR DISPLAYS ABOVE TICKET COUNTER. PROVIDE STRUCTURAL MOUNTING PLATES COMPATIBLE WITH EXTENSIONS COLUMN. TV1 SAMSUNG QB55R SERIES 55" 4K UHD TV TV3 SAMSUNG QB55R SERIES 55" 4K UHD TV NOTE 3 TV4 SAMSUNG QB65R SERIES 65" 4K UHD TV TV5 SAMSUNG QB55R SERIES 55" 4K UHD TV TV6 SAMSUNG QB75R SERIES 75" 4K UHD TV TV7 VISUAL SOLUTIONS # WALLMATE 32 - TNV SAMSUNG QB85R SERIES 85" 4K UHD TV VISUAL SOLUTIONS # WALLMATE 16 - TNV VISUAL SOLUTIONS # WALLMATE 16 - TNV VISUAL SOLUTIONS # WALLMATE 16 - TNV VISUAL SOLUTIONS # WALLMATE 16 - TNV VISUAL SOLUTIONS # WALLMATE 16 - TNV RACK 'AV' (DATA 133) DIGITAL MEDIA CARD CHASSIS, (PROVIDED AS PART OF RACK BUILD OUT) BUILDING CONTROL PROCESSOR, (PROVIDED AS PART OF RACK BUILD OUT) BUILDING CONTROL VIDEO CONTROLLER, (PROVIDED AS PART OF RACK BUILD OUT) AV SWITCH, (PROVIDED AS PART OF RACK BUILD OUT) PATCH CORD (1) ENCODER # DM-NVX-363C SIGNAGE PLAYER, DIGITAL SIGNAGE # MEDIABOX-200 PATCH CORD FROM PATCH PANEL FOR DISPLAY ABOVE (BY DIV. 271500) PATCH CORD HDMI CABLE SPEAKER (3), LOWELL # LUH-15 W/ VANDAL RESISTANT GRILL AND EXTERIOR RATED BACKBOX. TAP SPEAKERS AT 15W, 70 VOLTS. SEE PLANS FOR SPEAKER QUANTITIES AND LOCATIONS. RACK MOUNT AMPLIFIER, POWERSOFT # MEZZO 324 AD S 3 [ZONE 1A] [ZONE 1B] [ZONE 1C] S 3 S 1 SPEAKER (1), SONANCE # PS-C63RT (WHITE). TAP SPEAKERS AT 15W, 70 VOLTS. SEE PLANS FOR SPEAKER QUANTITIES AND LOCATIONS. RACK 'AV' (DATA 133) RACK MOUNT AMPLIFIER, (PROVIDED AS PART OF GATE BUILD OUT) S 2 [ZONE 2A] [ZONE 2B] S 1 RACK 'AV' (DATA 133) VIDEO WALL PROCESSOR, NOVASTAR # VX1000 RACK MOUNT AMPLIFIER, (PROVIDED AS PART OF GATE BUILD OUT) S 1 DIGITAL MEDIA CARD CHASSIS, (PROVIDED AS PART OF RACK BUILD OUT) (1) ENCODER # DM-NVX-363C BUILDING CONTROL PROCESSOR, (PROVIDED AS PART OF RACK BUILD OUT) BUILDING CONTROL VIDEO CONTROLLER, (PROVIDED AS PART OF RACK BUILD OUT) AV SWITCH, (PROVIDED AS PART OF RACK BUILD OUT) SIGNAGE PLAYER #1, DIGITAL SIGNAGE # MEDIABOX-200 1.9MM PITCH LED PANELS, ABSEN ACCLAIM PLUS, (TYP OF 40), TOTAL RESOLUTION: 1600x1440 PROVIDE WITH PERIMETER TRIM KIT (5) CAT 6 CABLES TO VIDEO DISPLAY CAT 6 DATA CABLE (BY DIV. 271500 CONTRACTOR) PAGING STATION, QSC # PS-1650G CAT 6 PATCH CORD FROM PATCH PANEL TO AV SWITCH M MICROPHONE HDMI CABLE (1) PATCH CORD HDMI CABLE TELEVISION #1TV CONTROL CABLE 6' HDMI CABLE DISPLAY (TV2) SEE DISPLAY SCHEDULE (INSTALL DISPLAY SO TOP IS 2" BELOW WOOD CEILING) NETWORK DECODER, CRESTRON # DM-NVX-D30 (MOUNTED BEHIND DISPLAY) PATCH CORD TO OWNER NETWORK (BY DIV. 27) PATCH CORDS FROM PATCH PANEL FOR DISPLAYS ABOVE (BY DIV. 271500) TELEVISION #2TV CONTROL CABLE 6' HDMI CABLE NETWORK DECODER, CRESTRON # DM-NVX-D30 (MOUNTED BEHIND DISPLAY) PATCH CORD TO OWNER NETWORK (BY DIV. 27) DISPLAY (TV2) SEE DISPLAY SCHEDULE (INSTALL DISPLAY SO TOP IS 2" BELOW WOOD CEILING) TELEVISION #3TV CONTROL CABLE 6' HDMI CABLE NETWORK DECODER, CRESTRON # DM-NVX-D30 (MOUNTED BEHIND DISPLAY) PATCH CORD TO OWNER NETWORK (BY DIV. 27) DISPLAY (TV2) SEE DISPLAY SCHEDULE (INSTALL DISPLAY SO TOP IS 2" BELOW WOOD CEILING) TELEVISION #4TV CONTROL CABLE 6' HDMI CABLE NETWORK DECODER, CRESTRON # DM-NVX-D30 (MOUNTED BEHIND DISPLAY) PATCH CORD TO OWNER NETWORK (BY DIV. 27) DISPLAY (TV4) SEE DISPLAY SCHEDULE [ZONE 2A] S 2 [ZONE 2B] S 4 SPEAKER (1), SONANCE # PS-C63RT (WHITE). TAP SPEAKERS AT 15W, 70 VOLTS. SEE PLANS FOR SPEAKER QUANTITIES AND LOCATIONS. SPEAKER (2), SONANCE # PS-C63RTLP. TAP SPEAKERS AT 30W, 70 VOLTS. SEE PLANS FOR SPEAKER QUANTITIES AND LOCATIONS. SPEAKER (4), SONANCE # PS-C63RT W/ WHITE SQUARE GRILLE AND ADAPTER. TAP SPEAKERS AT 7.5W, 70 VOLTS. SEE PLANS FOR SPEAKER QUANTITIES AND LOCATIONS. TELEVISION #5TV CONTROL CABLE 6' HDMI CABLE NETWORK DECODER, CRESTRON # DM-NVX-D30 (MOUNTED BEHIND DISPLAY) PATCH CORD TO OWNER NETWORK (BY DIV. 27) DISPLAY (TV5) SEE DISPLAY SCHEDULE [ZONE 2C] S 5A S 5B SPEAKER (5), K-ARRAY # VYPER-KV25. TAP SPEAKERS AT 32 OHM. SEE PLANS FOR SPEAKER QUANTITIES AND LOCATIONS. 5A: SPEAKER COLOR = WHITE 5B: SEAKER COLOR = COORDINATE WITH ARCHITECTURAL WINDOW MULLION. RACK MOUNT AMPLIFIER, (PROVIDED AS PART OF GATE BUILD OUT) [ZONE 2D] S 5A S 5B AUDIO CABLE AUDIO CABLE PROVIDE LEGRAND TiLED MOUNTING SYSTEM FOR ALL VIDEO WALL PANELS BASIS OF DESIGN FOR POWER SUPPLIES IS 208V ELECTRICAL CONNECTIONS, COORDIN...

City of Kearney, NE 68847, United StatesLocation

Address: City of Kearney, NE 68847, United States

Country : United StatesState : Nebraska