65--Ergonomic Adjustable Sink for Edward Hines Jr. VA Medical Center

expired opportunity(Expired)
From: Federal Government(Federal)
36C25219Q0380

Basic Details

started - 19 Feb, 2019 (about 5 years ago)

Start Date

19 Feb, 2019 (about 5 years ago)
due - 25 Feb, 2019 (about 5 years ago)

Due Date

25 Feb, 2019 (about 5 years ago)
Bid Notification

Type

Bid Notification
36C25219Q0380

Identifier

36C25219Q0380
Department of Veterans Affairs

Customer / Agency

VETERANS AFFAIRS, DEPARTMENT OF (102973)VETERANS AFFAIRS, DEPARTMENT OF (102973)252-NETWORK CONTRACT OFFICE 12 (36C252) (4664)
unlockUnlock the best of InstantMarkets.

Please Sign In to see more out of InstantMarkets such as history, intelligent business alerts and many more.

Don't have an account yet? Create a free account now.

This Sources Sought Notice is for informational and planning purposes only and shall not be construed as a solicitation or as an obligation or commitment by the Government at this time. This notice is intended strictly for market research. The purpose of this Sources Sought notice is to determine interest and capability of Other than Small Businesses and/or Small Businesses, including VIP-Verified Veteran-Owned Small Business (VOSB) or Service-Disabled Veteran-Owned Small Business (SDVOSB) prospective contractors relative to the North American Industry Classification System (NAICS) Code 339113 (Surgical Appliance and Supplies Manufacturing). Ergonomic Adjustable Sink (Steris Model No. SW04124) is known to meet the Government s needs. The Government is requesting that Other Than Small Businesses and Small Businesses, including VIP-Verified VOSB or SDVOSB sources respond: CLIN Description of Supplies/Services Qty Unit 0001 AMSCO 73 Reprocessing Sink, 120" Triple Aqua Klenz, Wash, &
Rinse Bays LR LOCAL STOCK NUMBER: SW04124 1 EA 0002 Flex Plate (Qty 2) LOCAL STOCK NUMBER: SWA001 1 EA 0003 AMSCO 70 Lumen Klenz LOCAL STOCK NUMBER: SW000001 1 EA 0004 Install AMSCO 70 Adjustable Sink LOCAL STOCK NUMBER: SE101582 1 JB If offering equal , the vendor is responsible for submitting enough supporting information/documentation to illustrate their capability to meet or exceed the following Salient Characteristics. Salient Characteristics for Ergonomic Adjustable Sink (Steris Model No. SW04124) Ergonomic hydraulic sinks- **needs to be AAMI compliant The Reprocessing Sink must have the ability to be adjustable in height The sink also needs to have a minimum of a triple bay configuration The overall sink counter length must be in the measurement range of 80-120" Must also have the ability to have the following workk flow configurations of right-to-left and left-to right Reprocessing Sink Bays Must be commercial grade stainless steel with both wash and rinse bays The overall dimensions must be within the measurements and not to exceed 17"x10"x 24" (432 x 254 x 610 mm) Counter tops of the sink- Must have an incline that prevents water dripping to floors, which can cause safety risks. Must have the ability to adjust the height of the sink to a minimum height (range of 33-41") Must contain needs to include all of the following: Stainless-steel magnetic back splash Overhead Lighting System Magnification Light Faucet One-Touch Button (faucet activation) Control Screen containing icons (touch screen) to activate software programming Record Keeping abilities to record data Auto Drain and Fill options Aqua Klenz & Sonic Klenz options Air and Pure Water Pistols Tie-Down Kit Overall (width, height, and length) must be a at a minimum of: 30"x33-41"x80", 94", 106", 120" Steam: dynamic pressure with steam pressure regulators, shut-off valves steam traps, insulation and pipe routing necessary to supply at least up to 97% vapor-quality steam Air: dynamic pressure Water: dynamic water pressure with pressure regulators with properly sized piping to prevent water hammering (water flow) Exhaust: must be certified or approved Waste: must have proper drain(s), sized to handle water/steam flow rates Electric: must have electrical supply Atmospheric Vent: vent piping for pressure relief valves that also has drip pan elbow at connection point Telecommunications options: must include the following specs and capabilities Technical Support prior to dispatching a service technician. Allow connection to Response Center Computer Requirements needs to have the all of the following elements Desktop, server or virtual computer to run Remote Monitoring software, service agent and support software Windows 7 or Windows Server 2008 2.5GHz Multi-Core Processor 4GB ram 10GB Free Hard Drive Space Local admin account for assigned to connected facility network (access to Internet) If offering equipment as a non-manufacturer (i.e. distributor) the vendor is also required to submit with their quote proof (letter, etc.) from the manufacturer that shows they are authorized as a distributor of the equipment. DELIVERY SCHEDULE All items to be delivered F.O.B. Destination during normal working hours, between 7:30am and 2:30pm, Monday through Friday. CLIN Quantity Delivery Date All Items SHIP TO: Department of Veterans Affairs Edward Hines Jr. VA Medical Center 5000 South 5th Ave Hines, IL 60141-3030 United States All Items XX-Days ARO Interested Other Than Small Businesses and Small Businesses including VIP-Verified VOSBs and SDVOSBs are required to submit an e-mail delineating: Capability Statement; Business size/Socioeconomic status; If the product is on the Federal Supply Schedule or the Open Market; and Memo or correspondence from manufacturer to distribute their products. This is not a Request for Proposal/Quote or an announcement of a solicitation and no solicitation package exists at this time. Responses will be used solely for market research purposes of the Government. The Government will not pay for any materials provided in response to this notice and submissions will not be returned to the sender. VOSBs and SDVOSBs must be registered and verified in VIP for set-aside consideration. The applicable North American Industry Classification System (NAICS) Code for this requirement is 339113 and the small business size standard is 750 employees. Responses should be submitted by e-mail to Carl Weber at carl.weber3@va.gov. The information requested must be received no later than 11:59pm Central Standard Time on Monday, February 25, 2019. Subject line shall reference Sources Sought announcement number 36C25219Q0380 from FBO.gov.

Department of Veterans Affairs;Great Lakes Acquisition Center (GLAC);115 S 84th Street, Suite 101;Milwaukee WI 53214-1476Location

Place Of Performance : Department of Veterans Affairs;Great Lakes Acquisition Center (GLAC);115 S 84th Street, Suite 101;Milwaukee WI 53214-1476

Country : United StatesState : Wisconsin

You may also like

TEMPERATURE CONTROL SERVICES AT EDWARD HINES JR. VA MEDICAL CENTER

Due: 30 Sep, 2027 (in about 3 years)Agency: VETERANS AFFAIRS, DEPARTMENT OF

DENTAL WATERLINE TESTING FOR THE EDWARD HINES, JR. VA HOPSITAL

Due: 31 Jul, 2025 (in 15 months)Agency: VETERANS AFFAIRS, DEPARTMENT OF

MEDICAL GAS SYSTEM MAINTENANCE FOR THE EDWARD HINES, JR. VA HOSPITAL LOCATED IN HINES, ILLINOIS.

Due: 31 May, 2026 (in about 2 years)Agency: VETERANS AFFAIRS, DEPARTMENT OF

Please Sign In to see more like these.

Don't have an account yet? Create a free account now.

Classification

339 -- Miscellaneous Manufacturing/339113 -- Surgical Appliance and Supplies Manufacturing
naicsCode 339113Surgical Appliance and Supplies Manufacturing
pscCode 65MEDICAL/DENTAL/VETERINARY EQPT/SUPP