INSIGNIA, SHOULDER S

expired opportunity(Expired)
From: Federal Government(Federal)
SPE1C1-22-T-1667

Basic Details

started - 21 Sep, 2022 (19 months ago)

Start Date

21 Sep, 2022 (19 months ago)
due - 03 Oct, 2022 (18 months ago)

Due Date

03 Oct, 2022 (18 months ago)
Bid Notification

Type

Bid Notification
SPE1C1-22-T-1667

Identifier

SPE1C1-22-T-1667
Department of Defense

Customer / Agency

Department of Defense
unlockUnlock the best of InstantMarkets.

Please Sign In to see more out of InstantMarkets such as history, intelligent business alerts and many more.

Don't have an account yet? Create a free account now.

CONTINUATION SHEET REFERENCE NO. OF DOCUMENT BEING CONTINUED: CONTINUED ON NEXT PAGE PAGE 5 OF 30 PAGES SPE1C1-22-T-1667 SECTION B PR: 0096025296 NSN/MATERIAL:8455016188341 ITEM DESCRIPTION INSIGNIA,SHOULDER S INSIGNIA, SHOULDER SLEEVE(>,)> UNITED STATES OF AMERICA, NATIONAL FLAG, FULL COLOR LEFT SHOULDER WITH BLACK HOOK FASTENER THE HOOK FASTENER TAPE THE HOOK FASTENER TAPE SHALL CONFORM TYPE I, CLASS 1 OF A-A-55126. OVEREDGE STITCHING REQUIRED. MINIMUM STITCH COUNT IS 4554 STITCHES. DD 22571 A-1-786 03/11/2013 CARTOON A-1-786 03/01/2013 . RP001: DLA PACKAGING REQUIREMENTS FOR PROCUREMENT RA001: THIS DOCUMENT INCORPORATES TECHNICAL AND/OR QUALITY REQUIREMENTS (IDENTIFIED BY AN 'R' OR AN 'I' NUMBER) SET FORTH IN FULL TEXT IN THE DLA MASTER LIST OF TECHNICAL AND QUALITY REQUIREMENTS FOUND ON THE WEB AT: http://www.dla.mil/HQ/Acquisition/Offers/eProcurement.aspx FOR SIMPLIFIED
ACQUISITIONS, THE REVISION OF THE MASTER IN EFFECT ON THE SOLICITATION ISSUE DATE OR THE AWARD DATE CONTROLS. FOR LARGE ACQUISITIONS, THE REVISION OF THE MASTER IN EFFECT ON THE RFP ISSUE DATE APPLIES UNLESS A SOLICITATION AMENDMENT INCORPORATES A FOLLOW-ON REVISION, IN WHICH CASE THE AMENDMENT DATE CONTROLS. CONVERTION FROM ACU TO OCP: FOLIAGE GREEN BACKGROUND TO BE BAGBY GREEN 67204 BLACK TO REMAIN BLACK HAN 67138 BROWN TO BE OLIVE DRAB 67133 UNLESS PRE-APPROVED BY THE CONTRACTING OFFICER ALL ACU HOOK FASTENER BACKING SHALL BE FOLIAGE GREEN AND OVEREDGE TO THE INSIGNIA. ALL OCP HOOKFASTENER BACKING SHALL BE TAN 499 AND OVEREDGE TO THE INSIGNIA . CAUTION NOTICE THE DEPARTMENT OF DEFENSE IS PROHIBITED BY THE PROVISIONS OF THE BERRY AMENDMENT FROM PROCURING ITEMS OF CLOTHING THAT HAVE NOT BEEN GROWN OR PRODUCED IN THE UNITED STATES OR ITS POSSESSIONS. IF OTHER THAN SCHIFFLI EMBROIDERY MACHINE IS USED(>,)> THE STITCH COUNT ON GOVERNMENT CARTOON MUST BE DOUBLED. . ALTHOUGH THE DOCUMENT CALLS FOR MORE THAN ONE YARN, ONLY THE ALTERNATE CITED TO RAYON IN THIS CASE POLYESTER, WILL BE CONSIDERED FOR DLA TROOP SUPPORT CONTRACTS. . INSIGNIA SHALL BE FABRICATED IN ACCORDANCE WITH MIL-DTL-14652B DATED, 18 DEC. 2001 AND APPLICABLE CARTOON AND DRAWING. ADDITIONAL INFORMATION FOR MIL-DTL-14652: . PAGE 10, PARA 4.1.1, FIRST ARTICLE INSPECTION AT THE END OF PARA. ADD "THE FIRST ARTICLE CONTINUATION SHEET REFERENCE NO. OF DOCUMENT BEING CONTINUED: CONTINUED ON NEXT PAGE PAGE 6 OF 30 PAGES SPE1C1-22-T-1667 SECTION B SHALL BE BEST QUALITY PRE-PRODUCTION SAMPLES.". THE FIRST ARTICLE SAMPLES MUST PACKAGED AND LABELED IN THE SAME MANNER AS THE CONTRACT QUANTITY UNIT PACK. . PARA. 4.1.2 CONFORMANCE INSPECTION. AT THE END OF PARA. ADD "THE CONFORMANCE INSPECTION SHALL CONSIST OF VISUAL EXAMINATION OF END ITEM AND EXAMINATION FOR DIMENSIONS.". . PARA. 4.3 METHODS OF INSPECTION ADD "EACH LOT SHALL BE INSPECTED IN ACCORDANCE WITH ANSI/ASQC Z1.4 AND CONTRACT.". . PARA. 4.3.1 TESTING OF COMPONENTS. AT THE END OF PARA. ADD "THE SAMPLE SIZE SHALL BE THREE UNIT FOR EACH TEST CHARACTERISTIC OF EACH COMPONENT. THE LOT SHALL BE UNACCEPTABLE IF ONE OR MORE UNITS FAIL TO MEET THE REQUIREMENTS IN TABLE III"." . PAGE 11, PARA. 4.3.2 VISUAL EXAMINATION OF END ITEM. AT THE END OF PARA. ADD "DEFECTS SHALL BE EXPRESSED IN DEFECTS PER HUNDRED UNITS. THE INSPECTION LEVEL SHALL BE II. THE ACCEPTABLE QUALITY LEVEL SHALL BE .40 FOR MAJOR AND 1.0 FOR MAJOR AND MINOR DEFECTS COMBINED.". . PAGE 13, PARA 4.3.3 EXAMINATION FOR DIMENSION. AT THE END OF THE PARA. ADD "THE DEFECTS SHALL BE EXPRESSED IN DEFECTS PER HUNDRED UNITS. THE INSPECTION LEVEL SHALL BE S3. THE ACCEPTABLE QUALITY LEVEL SHALL BE 1.5 FOR MAJOR DEFECTS. THE FIRST ARTICLE WILL BE REJECTED IF THE END ITEM HAVE ANY MAJOR DEFECTS.". . PARA. 4.3.4 END ITEM TESTING. AT THE END OF PARA. ADD "THE SAMPLE SIZE SHALL BE 10 INSIGNIAS THE LOT SHALL BE UNACCEPTABLE IF ONE OR MORE UNITS FAIL TO MEET THE REQUIEMENTS IN TABLE V.". PAGE 14, PARA. 5.1 PACKAGING ADD THE FOLLOWING: "UNIT PACKAGING. INSIGNIA OF ONE TYPE STYLE AND CLASS SHALL BE PUT IN BUNDLES OF TWENTY EACH AND PLACED IN A POLYETHYLENE BAG. THE BAG SHALL BE HEAT SEALED OR TAPED CLOSED. EACH BUNDLE SHALL BE MARKED IN ACCORDANCE WITH MIL-STD-129. . PAGE 14, PARA. 6.3 SAMPLES, DELETE IN ITS ENTIRETY. PAGE 4, ADD NEW PARAGRAPHS AFTER 3.3.1.1 AS FOLLOWS: (A.)THE FOLLOWING EMBROIDERED ORGANIZATIONAL INSIGNIAS SHALL HAVE THE HOOK FASTENER ON THE REVERSE: TYPE I, STYLE 1, CLASS 1 AND THE REVERSE U.S. NATIONAL FLAG ONLY. TYPE I, STYLE 1, CLASS 2 . (B.)THE HOOK FASTENER SHALL COVER THE ENTIRE BACK OF THE INSIGNIA AND SHALL BE FINISHED WITH THE OVEREDGE STITCHING. AS AN ALTERNATIVE, WHEN THE SHAPE OR SIZE OF THE INSIGNIA PROHIBITS THE OVEREDGE STITCH THROUGH THE HOOK FASTENER, THE INSIGNIA SHALL FIRST BE OVEREDGED CONTINUATION SHEET REFERENCE NO. OF DOCUMENT BEING CONTINUED: CONTINUED ON NEXT PAGE PAGE 7 OF 30 PAGES SPE1C1-22-T-1667 SECTION B THEN PLACE THE HOOK FASTENER TO THE BACK OF THE INSIGNIA AND ATTACH IT BY SEWING A SINGLE ROW OF LOCK STITCHING ON THE OVEREDGE STITCH LINE WITH A MINIMUM OF 12 TO 14 STITCHES PER INCH AND BACKSTITCHED NOT LESS THAN 1/4) AT START AND STOP. . (C.)THE HOOK FASTENER SHALL BE A GOOD AND MATCH TO FOLIAGE GREEN 504 (FOLIAGE GREEN CABLE HDB 67202 IN THE NEXT REVISION OF THE DEPARTMENT OF DEFENSE STANDARD SHADE FOR HERALDIC YARNS FOR EMBROIDERY AND RIBBONS). . -IN THE INTERIM, THE USE OF CAMOUFLAGE GREEN 483 AND BLACK CABLE HAN 67138 UNTIL THE FOLIAGE GREEN 504 SHADE HOOK FASTENER IS AVAILABLE. . -THE HOOK FASTENER SHALL BE TYPE II, CLASS 1 OF A-A-55126A. THE HOOK FASTENER SHALL BE FREE OF SLIT OR SPLIT EDGES. AS AN ALTERNATE, VELCRO BRAND HTH 841 EXTRUDED HOOK OR SIMILAR BRAND OFFERING A MINIMUM OF 1 POUND PEEL PER INCH AND 30 POUND PER SQUARE INCH SHEAR STRENGTH MAY BE USED. WHEN SPECIFIED IN THE ITEM DESCRIPTION -ALL AREAS OF SHOULDER SLEEVE INSIGNIA THAT ARE SHOWN ON DRAWINGS AND CARTOONS TO BE OLIVE DRAB 67133 SHALL BE FOLIAGE GREEN 504 ON THE SUBDUED INSIGNIA. . SUGGESTED SUPPLIER . BRADFORD , TELE 401-377-2231 A-A-52094B Thread, Cotton dated 01 May 2019 No Additional Information (ref. T1481) ADDITIONAL INFORMATION FOR CCC-C-461: . INTERIM CHANGES TO CCC-C-461C, AM. 1: . PAGE 1, PARA 2.1, ADD THE FOLLOWING NEW TYPE TO THE TABLE: . TYPE NOMINAL WEIGHT YARN PLY YARN . OZ. PER SQ. YD. WARP-FILLING "TYPE VII" "7.6" "1X1" "COMBED" . PAGE 3, ADD NEW PARAGRAPH: "2.1.1 NON-GOVERNMENT PUBLICATIONS. THE FOLLOW- ING DOCUMENTS FORM A PART OF THIS DOCUMENT TO THE EXTENT SPECIFIED HEREIN. UNLESS OTHERWISE SPECIFIED, THE ISSUES OF THE DOCUMENTS WHICH ARE DOD ADOPTED ARE THOSE LISTED IN THE ISSUE OF THE DODISS CITED IN THE SOLICITATION. UNLESS OTHERWISE SPECIFIED, THE ISSUES OF DOC- UMENTS NOT LISTED IN THE DODISS ARE THE ISSUES OF THE DOCUMENTS CITED IN THE SOLICITATION (SEE 6.2) . AMERICAN ASSOCIATION OF TEXTILE CHEMISTS AND COLORISTS . AATCC-8 COLORFASTNESS TO CROCKING: AATCC . CROCKMETER METHOD AATCC-15 COLORFASTNESS TO PERSPIRATION AATCC-16 COLORFASTNESS TO LIGHT AATCC-20 FIBER ANALYSIS: QUALITATIVE AATCC-20A FIBER ANALYSIS: QUANTITATIVE CONTINUATION SHEET REFERENCE NO. OF DOCUMENT BEING CONTINUED: CONTINUED ON NEXT PAGE PAGE 8 OF 30 PAGES SPE1C1-22-T-1667 SECTION B AATCC-61 COLORFASTNESS TO LAUNDERING, HOME . AND COMMERCIAL: ACCELERATED AATCC-81 PH OF THE WATER-EXTRACT FROM . BLEACHED TEXTILES AATCC-96 DIMENSIONAL CHANGES IN COMMERCIAL . LAUNDERING OF WOVEN AND KNITTED . FABRIC EXCEPT WOOL (COPIES OF THESE DOCUMENTS ARE AVAILABLE ONLINE AT HTTP://WWW.AATCC.ORG OR FROM THE AATCC NATIONAL HEADQUARTERS, P.O. BOX 12215, RESEARCH TRIANGLE PARK, NC 27709-2215.) . ASTM INTERNATIONAL . ASTM-D-276 IDENTIFICATION OF FIBERS IN . TEXTILES ASTM-D-629 QUANTITATIVE ANALYSIS OF TEXTILES ASTM-D-1683 FAILURE IN SEWN SEAMS OF WOVEN . FABRICS ASTM-D-2165 PH OF AQUEOUS EXTRACTS OF WOOL AND . SIMILAR ANIMAL FIBERS ASTM-D-3775 FABRIC COUNT OF WOVEN FABRIC ASTM-D-3776 MASS PER UNIT AREA (WEIGHT) OF . FABRIC ASTM-D-5034 BREAKING FORCE AND ELONGATION OF . TEXTILE FABRICS (GRAB METHOD) (COPIES OF THESE DOCUMENTS ARE AVAILABLE ONLINE AT HTTP://WWW.ASTM.ORG OR AT ASTM INTERNATIONAL, 100 BARR HARBOR DRIVE, WEST CONSHOHOCKEN, PA 19428-2959.)" . PAGE 4, TABLE I, AT END OF TABLE ADD: TYPE-"VII", YARN-"COMBED", YARN PLY WARP FILL- "1" "1", WEIGHT OZ. PER SQ. YD (MIN)(MAX)- "7.2" "8.0", YARNS PER INCH (MINIMUM) WARP FILL - "100" "54", BREAKING STRENGTH POUNDS (MINIMUM) WARP FILL-"120" "90", WEAVE-"3/1 TWILL TO LEFT" . PAGE 5, PARA 3.3.2, LINE 7, DELETE "FAIR" AND SUBSTITUTE "NOT LESS THAN "3" WHEN QUANTIFIED USING AATCC GRAY SCAL FOR COLOR CHANGE AND." PARA 3.3.4.1, LINE 5, DELETE "GOOD" AND SUBSTI- TUTE "NOT LESS THAN "3.5" WHEN QUANTIFIED USING AATCC GRAY SCALE FOR COLOR CHANGE". LINE 6, DELETE "AND NO MORE CROCKING THAN MUNSELL VALUE 8.5" AND SUBSTITUTE "AND CROCKING". . PAGE 6, PARA 3.7, LINES 2-3, AFTER "FILLING DIRECTION OF THE CLOTH, ADD: "FOR TYPES I-VI AND NO MORE THAN 3 PERCENT IN THE WARP AND 3 PERCENT IN THE FILLING FOR TYPE VII,". JUSTIFICATION: A NEW TYPE IS NEEDED FOR USE IN THE CONSTRUCTION OF MIL-H-81735. . PAGES 9, 10 AND 11, PARA 4.4, LINE 1, DELETE, "IN FED. STD. NO. 191, WHEREVER APPLICABLE, AND AS LISTED". TABLE II, MAKE THE FOLLOWING CHANGES: . FOR COTTON IDENTIFICATION, UNDER TEST METHOD, DELETE "1200", AND SUBSTITUTE "AATCC-20 OR ASTM-D-276". . FOR COMBED COTTON, DELETE "(TYPES I, II, III AND IV)" AND SUBSTITUTE "(TYPES I, II, III, IV AND VII)". . FOR DISCOLORATION (BLEACHED), UNDER TEST METHOD, DELETE "5660", AND SUBSTITUTE "AATCC- 16 OPT A". . FOR COLORFASTNESS TO LAUNDERING (AFTER 3 CONTINUATION SHEET REFERENCE NO. OF DOCUMENT BEING CONTINUED: CONTINUED ON NEXT PAGE PAGE 9 OF 30 PAGES SPE1C1-22-T-1667 SECTION B CYCLES), UNDER TEST METHOD, DELETE "5610", AND SUBSTITUTE "AATCC-61 TEST 3A". . FOR COLORFASTNESS TO PERSPIRATION, UNDER TEST METHOD, DELETE "5680", AND SUBSTITUTE "AATCC-15" . FOR COLORFASTNESS TO LIGHT, UNDER TEST METHOD, DELETE "5660" AND SUBSTITUTE "AATCC-16 OPT A". . FOR COLORFASTNESS TO CROCKING, UNDER TEST METHOD, DELETE "5651" AND SUBSTITUTE "AATCC-8". . FOR WEIGHT, UNDER TEST METHOD, DELETE "5041" AND SUBSTITUTE "ASTM-D-3776, OPTION C". . FOR YARNS PER INCH, WARP, UNDER TEST METHOD, DELETE "5050" AND SUBSTITUTE "ASTM-D-3775". . FOR YARNS PER INC, FILLING, UNDER TEST METHOD, DELETE "5050" AND SUBSTITUTE "ASTM-D-3775". . FOR BREAKING STRENGTH, WARP, UNDER TEST METHOD DELETE "5100" AND SUBSTITUTE "ASTM-D-5034". . FOR BREAKING STRENGTH, FILLING, UNDER TEST METHOD, DELETE "5100" AND SUBSTITUTE "ASTM-D- 5034". . FOR NONFIBROUS MATERIAL CONTENT, UNDER TEST METHOD, DELETE "2611" AND SUBSTITUTE "AATCC-20A OR ASTM-D-629". . FOR SHRINKAGE IN LAUNDERING, WARP, UNDER TEST METHOD, DELETE "5550" AND SUBSTITUTE "AATCC-96, TEST VC, D". . FOR SHRINKAGE IN LAUNDERING, FILLING, UNDER TEST METHOD, DELETE "5550" AND SUBSTITUTE "AATCC-96, TEST VC, D". . FOR SEAM EFFICIENCY, UNDER TEST METHOD, DELETE "5110" AND SUBSTITUTE "ASTM-D-1683". . FOR PH, UNDER TEST METHOD, DELETE "2811" AND SUBSTITUTE "AATCC-81 OR ASTM-D-2165". . FOOTNOTE 3, LINE 1, DELETE "METHOD 5660" AND SUBSTITUTE "AATCC-16 OPT A". LINE 5, DELETE "FAIR" AND SUBSTITUTE "NOT LESS THAN"3"". LINES 7-8, DELETE ""FAIR" INDICATED IN METHOD 5660" AND SUBSTITUTE "NOT LESS THAN "3"". . PAGE 13 UNDER CUSTODIANS, DELETE "NAVY-SA" AND SUBSTITUTE "NAVY-NU". UNDER "REVIEW ACTIVITY" ADD "NAVY-AS,MC". DELETE "UNDER ACTIVITY: NAVY-MC". (REF T0434). ADDITIONAL INFORMATION FOR FED-STD-191: FED-STD-191A NOTICE 7, DATED AUGUST 9, 2000 IS HEREBY INACTIVE FOR NEW DESIGN. WHEN NOT USING FED-STD-191, SEE INTERIM CHANGES TO END ITEM SPECIFICATION FOR REPLACEMENT ASTM. INTERIM CHANGES TO FED-STD-191A: TEST METHOD 5202, PARA. 5.3, DELETE FIRST SENTENCE AND SUBSTITUTE: "THE SPECIMEN SHALL BE CLAMPED FIRMLY, WITH ONE END FLUSH WITH THE OUTER EDGE OF THE VISE, SUCH THAT ONE INCH OF SPECIMEN LIES WITHIN THE CLAMP AND ONE INCH OF THE SPECIMEN EXTENDS BEYOND THE CENTER OF ROTATION (FACE OF THE VISE), AND WITH THE LONG EDGE PARALLEL TO THE FACE OF THE DIAL PLATE". TEST METHOD 5309.1 ABRASION RESISTANT OF TEXTILE WEBBING. PAGE 1, PARA 4.1.2,LINE 4: DELETE "B-97" AND SUBSTITUTE "B-91". THE FOLLOWING METHODS ARE IDENTIFIED AS SPECIFYING OZONE DEPLETING SUBSTANCES: 1100, 1200, 1240, 1400, 1410, 1500, 1510,1520,1530, 1540, AND 1550. PARA 5.1 OF THESE TEST METHODS REQUIRE THE USE OF 1,1,1- TRICHLOROETHANE, ALCOHOL OR ETHER. 1,1,1-TRICHLORETHANE IS AN OZONE DEPLETING SUBSTANCE (METHYL CHLOROFORM) AND IS THEREFORE PROHIBITED. THE USE OF EITHER ALCOHOL OR ETHER IS REQUIRED WHEN THESE METHODS ARE IN BASIC OR ANY REFERENCED DOCUMENT. CONTINUATION SHEET REFERENCE NO. OF DOCUMENT BEING CONTINUED: CONTINUED ON NEXT PAGE PAGE 10 OF 30 PAGES SPE1C1-22-T-1667 SECTION B METHOD 5202, STIFFNESS OF CLOTH, DIRECTIONAL; CANTILEVER BENDING METHOD. PAGE 2, PARA. 5.3 DELETE FIRST SENTENCE AND SUBSTITUTE WITH THE FOLLOWING: "THE SPECIMEN SHALL BE CLAMPED FIRMLY, WITH 1 END FLUSH WITH THE OUTER EDGE OF THE VISE, SUCH THAT 1" OF THE SPECIMEN LIES WITHIN THE CLAMP AND 1" OF THE SPECIMEN EXTENDS BEYOND THE CENTER OF ROTATION (INNER FACE OF THE VISE) AND WITH THE LONG EDGE PARALLEL TO THE FACE OF THE DIAL PLATE." METHOD 5556.1, MOBILE LAUNDRY EVALUATION FOR TEXTILE MATERIALS, PAGE 5, PARA. 5.2.2, LINE 8: DELETE SENTENCE BEGINNING WITH "THE SPECIMENS AND BALLAST" IN ITS ENTIRETY AND SUBSTITUTE WITH THE FOLLOWING: "THE SPECIMENS AND BALLAST SHALL BE SEPARATED, OPENED TO FULL WIDTH AND PLACED IN A PRE-HEATED DRYER HAVING A STACK TEMPERATURE OF 140-180 DEG. F. THIS TEMPERATURE RANGE CORRESPONDS TO A SETTING OF "HIGH" ON THE TEMPERATURE INDICATOR ON THE DRYER. DRYING SHALL CONTINUE FOR 45-60 MINUTES OR UNTILSAMPLES ARE DRY IN A ROTATING TUMBLE DRYER." PAGE 5, PARA. 5.2.3, LINE 8: DELETE SENTENCE BEGINNING WITH "THE SPECIMENS AND BALLAST" IN ITS ENTIRETY AND SUBSTITUTE WITH THEFOLLOWING: "THE SPECIMENS AND BALLAST SHALL BE SEPARATED, OPENED TO FULL WIDTH AND PLACED IN A PRE-HEATED DRYER HAVING A STACKTEMPERATURE OF 140-180 DEG. F. THIS TEMPERATURE RANGE CORRESPONDS TO A SETTING OF "HIGH" ON THE TEMPERATURE INDICATOR ON THE DRYER. DRYING SHALL CONTINUE FOR 35-40 MINUTES OR UNTIL SAMPLES ARE DRY." METHOD 5931, ELECTROSTATIC DECAY OF FABRICS; DETERMINATION OF PAGE 1, PARA. 3: AFTER NUMBER OF DETERMINATIONS ADD "PER SAMPLE UNIT". PAGE 1, PARA. 4: DELETE "APPARTUS" AND SUBSTITUTE "APPARATUS". PAGE 1, PARA. 5.1, LINE 3: AFTER "AT" DELETE"APPROXIMATELY". PAGE 2, PARA. 5.2, LINES 2, AND 5: AFTER "OF" ADD "+-". LINE 6: AFTER "TO" ADD "+-". PAGE 2, PARA. 5.3: DELETE IN ITS ENTIRETY AND SUBSTITUTE WITH THE FOLLOWING:"5.3 MOUNT A SPECIMEN TIGHTLY ACROSS THE ELECTRODES, CENTERING IT OVER THE SENSOR OPENING. THE SURFACE OF THE TEST SPECIMEN (BACK OR FRONT) SHALL FACE THE SENSOR. RECORD (OPTIONAL) THE RESIDUAL CHARGE LEVEL ON THE SAMPLE AS SEEN BY THE SENSOR, INCLUDING POLARITY. NOTE THAT TEST SAMPLES WITH THE RESIDUAL CHARGE LEVELS OF LESS +500 VOLTS YIELD THE BEST RESULTS. APPLY +5000 VOLTS TO THEELECTRODES FOR A PERIOD OF 20 SECS. AT THE END OF THE 20 SECOND PERIOD, THE HIGH VOLTAGE (5000 VOLTS) SHALL BE TURNED OFF ANDTHE SPECIMENS IMMEDIATELY GROUNDED. THE VOLTAGE BEHAVIOR OF THE SPECIMEN WITH RESPECT TO TIME SHALL BE PLOTTED ON THE RECORDER. NOTE: IN SOME CASES, THE TEST EQUIPMENT WILL DISPLAY VOLTAGE AND DECAY TIME INFORMATION AND A CHART RECORDER IS NOT NECESSARY." PAGE 2, PARA. 5.4, LINE 3: DELETE SENTENCE BEGINNING WITH "IF THE SPECIMEN DID" IN ITS ENTIRETY. PAGE 2, PARA. 5.5: DELETE PARAGRAPH IN ITS ENTIRETY AND SUBSTITUTE WITH THE FOLLOWING: "RECORD THE MAXIMUM VOLTAGE LEVEL(INCLUDING POLARITY) AND DECAY TIME TO 10% OF THE MAXIMUM VOLTAGE LEVEL ACHIEVED." PAGE 2, PARA. 5.6, LINE 1: ADD THE FOLLOWING PRIOR TO 1ST SENTENCE: "REVERSE VOLTAGE POLARITY REPEAT MEASUREMENT, ANDRECORD RESULTS." PAGE 3, PARA. 6.6: DELETE PARAGRAPH IN ITS ENTIRETY AND SUBSTITUTE WITH THE FOLLOWING: "THE AVERAGE TIME TO DECAY TO 10%OF THE MAX VOLTAGE SHALL BE INCLUDED FOR EACH OF THE WARP & FILLING DIRECTIONS, AS WELL AS THE OVERALL AVERAGE, FOR EACHFABRIC TESTED. THESE WILL BE OBTAINED BY AVERAGING THE TEST RESULTS (ABSOLUTE VALUE OF) TOGETHER FOR BOTH VOLTAGEPOLARITIES. UNLESS OTHERWISE STATED IN THE REQUIREMENTS DOCUMENT, THE FABRIC SHALL BE CONSIDERED ACCEPTABLE IF THEAVERAGE MAXIMUM VOLTAGE IN BOTH THE WARP AND FILLING DIRECTIONS IS LESS THAN 4000 VOLTS, AND THE AVERAGE DECAY TIME (TO 10% MAXVOLTAGE) IS GREATER THAN 0.5 SECONDS IN BOTH THE WARP AND FILLING DIRECTIONS. IT SHALL BE INDICATED WHETHER THE FABRIC ISACCEPTABLE OR NON-ACCEPTABLE." PAGE 3, PARA. 7.1, SECOND COLUMN, LINE 2: DELETE 406C AND SUBSTITUTE CONTINUATION SHEET REFERENCE NO. OF DOCUMENT BEING CONTINUED: CONTINUED ON NEXT PAGE PAGE 11 OF 30 PAGES SPE1C1-22-T-1667 SECTION B WITH "406D". AFTER PARA. 7.1, ADD THE FOLLOWING: "7.2 NOTE: IF THE MODEL 406D STATIC DECAY METER, OR EQUIVALENT, IS USED, A CHART RECORDER ISNOT MANDATORY FOR THE TEST." (Ref. T0215) MIL-STD-129R w/CHANGE 2 - DEPARTMENT OF DEFENSE STANDARD PRACTICE MILITARY MARKING FOR SHIPMENT AND STORAGE DATED: 27 SEPTEMBER 2019 INTERIM CHANGES: OMISSION OF MARKINGS ON EXTERIOR SHIPPING CONTAINERS OF ITEMS IN THE DLA TROOP SUPPORT CLOTHING AND TEXTILE (C(>&)>T) DIRECTORATE: THE NOMENCLATURE AND MANUFACTURER'S NAME (WHEN THE NAME IDENTIFIES THE MATERIAL) SHALL BE OMITTED FROM ALL EXTERIOR SHIPPING CONTAINERS OF DLA TROOP SUPPORT C(>&)>T ITEMS, REGARDLESS OF MODE OF SHIPMENT. IF THE MANUFACTURER'S NAME DOES NOT IDENTIFY THE MATERIAL AS BEING CLOTHING, IT MAY REMAIN. NSNS SHALL BE SHOWN ON ALL SHIPPING CONTAINERS OF C(>&)>T ITEMS, THE PACKING LIST SHALL BE PLACED INSIDE THE LAST CONTAINER TO BE LOADED FOR EACH SHIPMENT. THE WORDS "PACKING LIST HERE" SHALL BE STENCILED, NOT HAND LETTERED, ON THE CONTAINER. ADDITIONAL INFORMATION FOR ANSI/ASQC Z1.4: NOTE: THE MOST RECENT VERSION OF THIS DOCUMENT SHOULD BE USED. APPLICATION FOR COPIES SHOULD BE ADDRESSED TO: AMERICAN SOCIETY FOR QUALITY 600 NORTH PLANKINTON AVENUE MILWAUKEE, WISCONSIN 53203 (Ref. T0795 - May 17, 2006) FIVE (5) FIRST ARTICLE SAMPLES ARE REQUIRED. FIRST ARTICLE TESTING SHALL BE PERFORMED AND THE CONTRACTOR WILL BE NOTIFIED IN WRITING WITHIN THIRTY (30) CALENDAR DAYS AFTER CONTRACTING OFFICER'S RECEIPT OF FIRST ARTICLE SAMPLES. IAW BASIC SPEC NR MIL-DTL-14652B NOT 2 REVISION NR B DTD 05/01/2018 PART PIECE NUMBER: IAW REFERENCE DRAWING NR 22571 A-1-786 REVISION NR DTD 03/11/2013 PART PIECE NUMBER: IAW REFERENCE SPEC NR MIL-C-82252D REVISION NR D DTD 04/04/1983 PART PIECE NUMBER: IAW REFERENCE STD NR MIL-STD-105E NOT 3 REVISION NR E DTD 02/06/2008 PART PIECE NUMBER: IAW REFERENCE STD NR MIL-STD-1916 NOT 2 REVISION NR DTD 06/05/2014 PART PIECE NUMBER: IAW REFERENCE CID A-A-203C NOT 3 REVISION NR C DTD 11/19/2004 PART PIECE NUMBER: IAW REFERENCE CID A-A-1671B(I1) NOT 2 REVISION NR 1 DTD 02/15/2000 PART PIECE NUMBER: IAW REFERENCE CID A-A-1894B NOT 1 REVISION NR B DTD 10/20/1999 PART PIECE NUMBER:

700 Robbins Avenue Philadelphia PA 19111Location

Address: 700 Robbins Avenue Philadelphia PA 19111

Country : United StatesState : Pennsylvania

You may also like

INSIGNIA, GRADE, ENLI

Due: 02 May, 2024 (in 7 days)Agency: Department of Defense

84--INSIGNIA,GRADE,ENLISTED

Due: 03 May, 2024 (in 8 days)Agency: DEPT OF DEFENSE

84--INSIGNIA,SHOULDER S

Due: 03 May, 2024 (in 8 days)Agency: DEPT OF DEFENSE