From: Federal Government(Federal)
Basic Details | Start Date02 Aug, 2022 (21 months ago)Due Date08 Aug, 2022 (20 months ago) |
Customer / Agency | |
SetAside | SBA(Total Small Business Set-Aside (FAR 19.5)) |
Attachments (1) | |
STATEMENT OF WORK LEROY POND ADA DOORS VETERANS HEALTHCARE SYSTEM OF OZARKS BACKGROUND Contractor to provide and install six automatic door openers on two single walkway doors and two sets of double entry doors to allow easy access to the facility for handicaped patients and visitors. SCOPE AND DEFINITION OF SERVICES Contractor shall provide all labor, tools, equipment and transportation and supervision necessary to complete all work associated with installing automatic door openers on two separate single entrance doors at Building # 30 and two sets of double entrance doors at Building # 32, located at Leroy Pond / Veterans Healthcare System of the Ozarks (VHSO) located at 1100 North College Avenue, Fayetteville Arkansas 72703. OVERVIEW VHSO owns and/or operates Leroy Pond which offers residential programs among other services to our veterans. The purpose of this contract is to ensure; z All equipment shall be maintained to operate in a correct and safe manner as intended and designed
by the Original Equipment Manufacturer (OEM). Preventive maintenance is completed on time and in accordance with OEM recommendations. All software operates as designed. All equipment/items are inspected to ensure safe and correct operation in compliance with applicable local, state and federal regulations. Equipment downtime is kept to a minimum by maintaining no less than a 98% in-service rate for all covered equipment. TASKS Furnish and install 2 7100 Series Single Low Energy Operator(s) for two single entrance doors located Building # 30 Operator(s) To Be Series 7000 And Shall Be Low Energy, Self-Contained, Electromechanical Design. Operator To Be Powered Open By D.C. Motor With Six Reduction Gears. Closing Accomplished By Spring Force And motor Is To Be Off When Operator Is In Closing Mode. Door Can Be Manually Operated With Power On Or Off Without Damages To Operator. Finish To Be Clear Anodized Aluminum Header To Be 46 In Length And Of RHR And LHR Configuration Three Way On/Off/Hold Open Toggle Mounted On Header Operator And Controls To Be Manufactured By D.C. Controls, Addison, TX. 888-906-1123 4 BEA Model PB10 Push Plate Switches 2 Power One 12-2A Power Supply 2 Sedco Model 944 TDM Sequencers With Altronix 12/24 Lock Monitor Relays All Activation Manufactured By BEA, Pittsburgh, PA. 800-523-2462 Provide One Year Parts And Labor Warranty 3.2 Furnish and Install Low Energy Operators On Exterior double doors located Building # 32 , With 3 Push Plate Switches. See attached drawings. 7100 Series Dual Low Energy Operator(s), Operator(s) To Be Series 7000 And Shall Be Low Energy, Self-Contained, Electromechanical Design. Operator To Be Powered Open By D.C. Motor With Six Reduction Gears. Closing Accomplished By Spring Force And motor Is To Be Off When Operator Is In Closing Mode. Door Can Be Manually Operated With Power On Or Off Without Damages To Operator. Operator And Controls To Be Manufactured By D.C. Controls, Addison, TX. 888-906-1123 2 BEA Model PB10 Push Plate Switches 1 BEA Model PB10G1 Vestibule Switch 1 Altronix 12/24 Monitor Relay All Activation Manufactured By BEA, Pittsburgh, PA. 800-523-246 Finish To Be Clear Anodized Aluminum Header To Be 88 In Length And Of RHR, LHR Configuration Three Way On/Off/Hold Open Toggle Mounted On Header One Year Parts And Labor Warranty 3.3 Furnish and install Low Energy Operators On Interior Pair of doors , With 3 Push . Plate Switches located on interior of building # 32. 1 7100 Series Dual Low Energy Operator(s), Operator(s) To Be Series 7000 And Shall Be Low Energy, Self-Contained, Electromechanical Design. Operator To Be Powered Open By D.C. Motor With Six Reduction Gears. Closing Accomplished By Spring Force And motor Is To Be Off When Operator Is In Closing Mode. Door Can Be Manually Operated With Power On Or Off Without Damages To Operator. Finish To Be Clear Anodized Aluminum Header To Be 87-1/2 In Length And Of RHR, LHR Configuration Three Way On/Off/Hold Open Toggle Mounted On Header Operator And Controls To Be Manufactured By D.C. Controls, Addison, TX. 888-906- 11 4.0 Provide emergency repair on equipment to return it to OEM specified operating parameters 4.1 Provide priority emergency service response including a factory certified field service engineer on-site within 4 hours of emergency service notification. 5.0 Planned Maintenance including performing manufacturer s recommended maintenance.