6515--405-20-3-7821-0109; Grossing Station (VA-20-00029661)

expired opportunity(Expired)
From: Federal Government(Federal)
36C24120Q0408

Basic Details

started - 24 Jun, 2020 (about 3 years ago)

Start Date

24 Jun, 2020 (about 3 years ago)
due - 29 Jun, 2020 (about 3 years ago)

Due Date

29 Jun, 2020 (about 3 years ago)
Pre-Bid Notification

Type

Pre-Bid Notification
36C24120Q0408

Identifier

36C24120Q0408
VETERANS AFFAIRS, DEPARTMENT OF

Customer / Agency

VETERANS AFFAIRS, DEPARTMENT OF (103374)VETERANS AFFAIRS, DEPARTMENT OF (103374)241-NETWORK CONTRACT OFFICE 01 (36C241) (3845)

Attachments (1)

unlockUnlock the best of InstantMarkets.

Please Sign In to see more out of InstantMarkets such as history, intelligent business alerts and many more.

Don't have an account yet? Create a free account now.

GROSSING STATION Requirement Summary VA White River Junction, VT. requires replacement of a grossing station for histology. An elevating grossing station with additional knee space is required for ergonomic and staff safety as the table can be adjusted to accommodate varying heights of pathology staff to reduce back strain. Grossing stations provide a workspace for specimen preparation and are used to measure, wash, dissect, and magnify the view of the specimen while dictating notes and filtering fumes. Gross examination or "grossing" is the process by which pathology specimens are inspected with the "bare eye" to obtain diagnostic information, while being processed for further microscopic examination. Statement of Work (SOW) New unit provide and ship to VA WRJ, move, connect, install, assemble, level, test for working order, clean, provide staff training, warrantee. Provide all needed personnel and rigging as applicable. Work required as follows: 1) Move new unit from 1st floor -
warehouse storage location, to 2nd floor lab - installation location (see ** as noted below) 2) assemble, set-up, level as needed 3) make all unit connections to include (electrical, venting, water supply, and wastewater), 4) certify proper connections made to include (electrical, venting, water supply, and wastewater), 5) certify unit to be in accordance with manufacturer installation and operation specifications 6) clean unit to prepare for use as needed 7) provide user training, if/as applicable and or manufacturer user equipment literature 8) all work to occur and be complete over (1) one weekend, during weekend lab-off-hour-shifts (see *** as noted below), (Shawn McNamara, C.O.R., and Sue Webber, Lab Manager, to coordinate work schedule date and time) *VA White River Junction will be responsible to decontaminate, disconnect, remove, move, and disposal of existing grossing station, and prepare area for installation of new unit. ** VA WRJ FMS (facility management service) staff upon request, may/will provide assistance to vendor with relocation of new grossing station from, 1st floor - warehouse storage location, to 2nd floor lab - installation location. Elevator will be used to move unit from 1st to 2nd floor. *** Weekend Off hour installation required vendor must be flexible and able to coordinate and work weekend off hours to accommodate lab service operations and to complete in full: unit relocation, assembly, installation, unit connections, unit operation to manufacturer specification(s), and training, as weekend project completion is crucial to lab service operations, patient care and medical center requirements. Installation to be scheduled based on coordinated date. Anticipated installation to occur on Sunday with work to begin 7 am 5pm. Time frame provided as estimate. Dates, and times subject to change. All installation work must be fully completed prior to start of Monday 7am lab operations. Salient Characteristics Description unit required: Back/Down Draft Pathology Workstation - Elevating 60" Dimensions: 60" L x 32" W x 77" H Lowest / 90" Highest (fully extended) 1. All stainless-steel construction 2. Exhaust duct for connection to building ventilation system with adjustable bellows 3. Both downdraft and backdraft ventilation 4. Foot operated faucet control for hot and cold water 5. Spray hose assembly with hand control 6. Heavy duty waste disposer, 1/2 hp and switch 7. Dissecting area rinse to provide a constant flow of water below the work area 8. Top mounted LED light fixture. Stainless C-fold paper towel holder 9. Magnetic instrument holder. Polyethylene dissecting board (Photo Blue} 10. GFCI duplex receptacle w/waterproof cover Articulating camera Mount 11. Articulating Camera Mount 12. Splash Shield 13. Monitor and Keyboard Stand-Premium 14. Formalin Dispenser and Collection Systems contained 15. Vented Trash Container Specifications 1. Height adjustability to allow worker to work at unit sitting with feet on floor or standing. 2. Added knee space to allow for comfortable workspace when sitting. 3. Adjustable computer monitors and keyboard to all for good visibility and ergonomic positioning. 4. Foot pedal controls for water to allow for turning on and off water while freeing hands to handle specimens. 5. Hand spray rinse with long hose that allows easy and controlled rinsing or work area. 6. Formalin collection system at the work area to facilitate fume-free collection and easier disposal. Alarmed, if possible, to alert user the formalin collection system is nearing capacity. 7. Backdraft ventilation to safely remove formaldehyde fumes that could connect to in-house ventilation. 8. Sink with running water. 9. Electrical receptacle with waterproof cover and GCFI.

215 North Main Street  ,
 VT  05009  USALocation

Place Of Performance : 215 North Main Street

Country : United States

You may also like

GROSSING STATION AND ACCESSORIES

Due: 22 Oct, 2024 (in 5 months)Agency: INDIAN HEALTH SERVICE

6515--642-24-2-316-0115 | Laboratory Embedding Station | NCO 4 Commodities 2 (VA-24-00001618)

Due: 08 May, 2024 (in 10 days)Agency: VETERANS AFFAIRS, DEPARTMENT OF

Classification

naicsCode 334516Analytical Laboratory Instrument Manufacturing
pscCode 6515Medical and Surgical Instruments, Equipment, and Supplies