Notice of Intent to Sole Source - 80TECH23Q0004

expired opportunity(Expired)
From: Federal Government(Federal)
80TECH23Q0004

Basic Details

started - 12 Jan, 2023 (15 months ago)

Start Date

12 Jan, 2023 (15 months ago)
due - 27 Jan, 2023 (14 months ago)

Due Date

27 Jan, 2023 (14 months ago)
Bid Notification

Type

Bid Notification
80TECH23Q0004

Identifier

80TECH23Q0004
NATIONAL AERONAUTICS AND SPACE ADMINISTRATION

Customer / Agency

NATIONAL AERONAUTICS AND SPACE ADMINISTRATION (8264)NATIONAL AERONAUTICS AND SPACE ADMINISTRATION (8264)NASA IT PROCUREMENT OFFICE (79)
unlockUnlock the best of InstantMarkets.

Please Sign In to see more out of InstantMarkets such as history, intelligent business alerts and many more.

Don't have an account yet? Create a free account now.

STATEMENT OF WORK10x10 Optimus Lower SystemObjective/DescriptionListed below are the components required for a multi-channel rack mountable electronically scanned pressure measurement / acquisition system with built in intelligent pressure scanners and mini module pressure scanners. These components are to be fully compatible with existing TE Connectivity/ Measurement Specialties Incorporated Optimus systems. A market search has been performed and the recommended GSA vendor is:Characteristics, Scope, and Specs/RequirementsSystem shall support the following pressure scannersIntelligent Pressure Scanner, TE Connectivity/ Measurement Specialties Inc. Model 32HD Mini Module or fully equivalent with the following salient specifications:Compatible for use with TE Connectivity/ Measurement Specialties Inc. MSDI (mini scanner digitizing unit) via OSCB cable.Scanner shall contain an on board microprocessor and 32 pressure transducers, each with internal EEPROM memory chip for storing factory
calibration data.Unit shall be digitally compensated for zero, span, nonlinearity and temperature effects.Scanner shall be configured for full scale measurement range from a common reference input.Transducer accuracy, after re-zero, +/-0.03% full scale or better.Transducers shall be able to withstand 2X over pressure of full scale range without reducing sensor performance (Proof Pressure). Able to withstand 3X over pressure of full scale range without damaging sensor (Burst Pressure).Scanner shall have an operating range of 0 to 50 degrees C, the transducer reading shall be internally compensated to correct for temperature effects over this operating range of 0 to 50 deg C with a total thermal error of +/-0.001% F.S./deg C.Scanner shall provide front access for input of the pressure measurements.Scanner shall have 0.063” bulged tubulation fittings mounted on a quick disconnect plate for input of pressure measurements. Scanners shall have internal manifold valving and pneumatic calibration and control pressure inputs that allow for on-line pneumatic re-zero & span calibrations, and on-line leak checks of the pressure measurement transducers.Scanners shall be capable of reading rack source and purge pressures.Scanners shall support dual range calibration.System shall support the following controllersIntelligent Pressure Calibrator, Measurement Specialties Inc. Model 8432 or fully equivalent with the following salient specifications:Compatible for use with Measurement Specialties Optimus and 8400 Systems via the Remote Processor unit (part number 8404.)Able to perform calibration of Optimus mini modules (32HD and 64HD models)When used to calibrate Optimus mini modules, able to provide system accuracy of greater than +/- 0.03% FS.Able to perform Auto Accuracy Tests on the mini modules.Controller shall utilize resonant quartz pressure standards for absolute measurements and digital pressure standards for differential measurements.Contain a pressure relief valve designed to vent at 110% of the instruments full scale pressure.Controller shall provide known stable pressures to electronic pressure scanners for periodic calibration or validation.System shall support the following system controllerSystem Processor, TE Connectivity/ Measurement Specialties Inc. Model OSPR or fully equivalent with the following salient specifications:Compatible for use with TE Connectivity/ Measurement Specialties 32HD and 64HD mini modulesAble to control up to 32 mini modules for a maximum of 2048 data channels.Able to interface with TE Connectivity/ Measurement Specialties MSDI unit via OFIU (Optical Fiber Interface Unit) installed at the factory.Able to control TE Connectivity/ measurement Specialties PCU to calibrate Optimus mini modules, able to provide system accuracy of greater than +/- 0.03% FS.Interface with existing COBRA data systems in GRC facilities via in-house software and hardware trigger input on back panel.System shall support the following fiber interface unitsOptical Fiber Interface Unit, TE Connectivity/ Measurement Specialties Inc. Model OFIU or fully equivalent with the following salient specifications:Able to provide noise free data communication via 62.5 micron multimode fiber cable between the OSP and the MSDI scanner interface.Compatible for use with TE Connectivity/ Measurement Specialties 32HD and 64HD mini modules vis MSDI over fiber connection.Able to support simultaneous pressure and force balance measurements.System shall support the following remote processing unitsRemote Processor, TE Connectivity/ Measurement Specialties Inc. Model RP or fully equivalent with the following salient specifications:Able to interface with TE Connectivity/ Measurement Specialties OSPR System Processor via RS-485/ GPIB interface.Up to three RP units can be controlled by one OSPR unit.Able to interface with TE Connectivity/ Measurement Specialties PCU Pressure Controller Unit.Rack mountable unit. Can be placed in close proximity to mini modules to allow for short calibration tubing runs and therefore reduce calibration pressure settling time.Able to support simultaneous pressure and force balance measurements.System shall support the following remote power supply unitsRemote Power Supply, TE Connectivity/ Measurement Specialties Inc. Model RPS or fully equivalent with the following salient specifications:Able to provide closely regulated power to TE Connectivity/ Measurement Specialties MSDI unit.Able to provide +12 VDC, -12 VCD, and +5 VDC rail to TE Connectivity/ Measurement Specialties 32HD and 64HD mini modules.Also compatible with legacy 8400 system.System shall support the following miniature scanner digitizing interfacesMiniature Scanner Digitizing interface, TE Connectivity/ Measurement Specialties Inc. Model MSDI or fully equivalent with the following salient specifications:Able to provide regulated power to TE Connectivity/ Measurement Specialties 32HD pressure scanning mini modules.Able to provide excitation feedback measurement on the mini modules.Able to conduct analog to digital (A/D) conversion of signals coming from TE Connectivity/ Measurement Specialties models 32HD and or 64HD miniature pressure scanning units.Small size and low power consumption to allow for placement inside rack mounted system near the mini modules.Cross sectional area designed to match the 32HD and 64HD mini modules.Able to interface with TE Connectivity/ Measurement Specialties OFIU via fiber optic cable.Able to support connection of up to eight mini modules and able to scan a maximum of 512 pressure data channels.System shall require the following cables8476 MSDI power cable or fully equivalent with the following salient specifications:Able to provide regulated power to TE Connectivity/ Measurement Specialties MSDI, miniature scanner digitizing interface8484 GPIB interface cable or fully equivalent with the following salient specifications:Able to connect Optimus OSPR with Optimus remote rackAble to send serial GPIB communications between the two unitsOSCB scanner cable or fully equivalent with the following salient specifications:Able to connect 32HD miniature pressure scanner to MSDI miniature scanner digitizing interfaceAble to send regulated power to the 32HD miniature pressure scannerAble to send analog signals back to the MSDI from the 32HDAble to carry digital channel selection signal to the 32HD miniature pressure scanner.The desired quantities are listed on the NASA GRC376 form.WarrantyWarranty is for one year from delivery of equipmentInstallNot requiredMaintenance ServicesNot requiredPlace of PerformanceNASA Glenn Research Center10x10 SWT21000 Brookpark Rd. Cleveland, oh. 44135Point of Contact for RequirementRobert Armstrong Email: Robert.w.armstrong@nasa.gov (p) 216-433-2567Period of PerformancePeriod of performance is from receipt of equipment for service like of the equipment(over 10 years)Payment Schedule/Special Invoices:Payment is due before deliverySite Access Requirements/Work Schedule:none

Location

Place Of Performance : N/A

Country : United StatesState : OhioCity : Cleveland

You may also like

Notice of Intent to Sole Source C-SCAN Evaluation and Repair

Due: 18 Apr, 2024 (Today)Agency: DEPT OF DEFENSE

Notice of Intent to Sole Source

Due: 27 Apr, 2024 (in 9 days)Agency: ENERGY, DEPARTMENT OF

SOLE SOURCE NOTICE

Due: 22 Apr, 2024 (in 4 days)Agency: DEPT OF DEFENSE

Please Sign In to see more like these.

Don't have an account yet? Create a free account now.

Classification

naicsCode 541519Other Computer Related Services
pscCode 7H20IT AND TELECOM - PLATFORM PRODUCTS: DATABASE, MAINFRAME, MIDDLEWARE (HW, PERPETUAL LICENSE SOFTWARE)