Amendment 0003The purpose of this amendment is to:1. Incorporate revised mask standard effective 5-27-21. The revised mask standard is in addition to the Special Contract Requirement: COVID-19 (Construction Only) clause provided in Amendment 0002.2. Incorporate the questions and answers for SIR 697DCK-20-R-00186________________________________________________________________________________________________________Amendment 0002This amendment is to:1. Incorporate AMS Clause 3.6.4-24 Covered Telecommunications Equipment or Services - Representation (JAN 2021)2. Incorporate Special Contract Requirement: COVID-19 (Construction Only). Please note a COVID safety plan is required for submittal post-award.3. Incorporate updated Wage Determination General Decision Number UT20210085 01/29/2021 for Salt Lake City County, UT4. Update project milestones as follows:Site visit attendee list, in writing, to Contracting Officer: Tuesday, 6/8/2021 @ 1200 CTSite visit: Tuesday, 6/15/2021 @ 1000 CT (0900
MT)Questions due from offerors: Tuesday, 6/22/2021 @ 1200 CTAnswers out to offerors: Tuesday, 6/29/2021Proposals due: Tuesday, 7/6/2021 @ 1200 CT5. Change AMS Clause 3.2.2.3-63 Site Visit (Construction) (JUL 2004) to the updated mandatory site visit date/time and site visit attendee list due date/time listed in #4 updated project milestones of Amendment 0002.6. Change Clause SA19 Questions Regarding the Solicitation to the updated date/time listed in #4 updated project milestones of Amendment 0002._________________________________________________________________Amendment 0001This amendment is to postpone the mandatory site visit scheduled for Wednesday, 3/18/20 and any other due dates until further notice. This project is to renovate the Salt Lake City ARTCC B-105 & B-107 restrooms per the solicitation specifications.The work includes but is not limited to:(1) Removal of floor and wall finishes; (2) Removal of water closets, shower stalls, vanities, urinals, toilets, door B-107, solid surfaces and various restroom accessories; (3) Removal of mechanical systems such as duct accessories, plumbing fixtures and associated piping; (4) Removal of electrical systems such as lighting fixtures, outlets and wiring; (5) Installation of new floor and wall finishes, partitions, solid surfaces, and new and relocated louvered door for B-107; (6) Installation of new mechanical components such as: duct accessories, sinks, toilets, urinals, shower stalls, and localized plumbing connectivity; (7) Installation of new electrical components such as: lighting, outlets, switches and wiring; and (8) Inspect and test existing floor drain in both restrooms, clear drains of any debris or resolve any deficiencies by repair of modifications to ensure proper drainage.