AST STI SP0001 External Inspection Scott AFB, Illinois

expired opportunity(Expired)
From: Federal Government(Federal)
W9128F22Q0007

Basic Details

started - 09 Nov, 2021 (about 2 years ago)

Start Date

09 Nov, 2021 (about 2 years ago)
due - 24 Nov, 2021 (about 2 years ago)

Due Date

24 Nov, 2021 (about 2 years ago)
Bid Notification

Type

Bid Notification
W9128F22Q0007

Identifier

W9128F22Q0007
DEPT OF DEFENSE

Customer / Agency

DEPT OF DEFENSE (705815)DEPT OF THE ARMY (132664)USACE (37960)NWD (6900)W071 ENDIST OMAHA (1897)
[object Object]

SetAside

SBA(Total Small Business Set-Aside (FAR 19.5))

Attachments (6)

unlockUnlock the best of InstantMarkets.

Please Sign In to see more out of InstantMarkets such as history, intelligent business alerts and many more.

Don't have an account yet? Create a free account now.

5.1.  Basic Services.5.1.1.  Perform an External AST inspection to also include the visual inspection of the containment area.  The contractor shall visually inspect containment for ability to contain the entire contents of the tank in the event of catastrophic failure, assessing for cracks, settlement, and deterioration. Record dimensions of cracks and provide photographic evidence of each deficiency.5.1.2.  Provide DRAFT and FINAL inspection reports per the attached templates. The report(s) must include a record of NDE findings with drawings depicting plate layout and thickness measurement locations. Incorporate engineering analysis, suitability for service analysis pursuant to paragraph SUITABILITY FOR SERVICE, corrosion rate determinations, and remaining service life calculations. Provide separate report for each tank inspected. Specify the due date for the next inspection.5.2.  SUTABILITY FOR SERVICE:  Evaluate inspection data to determine suitability for continued use. Identify conditions which pose a risk to integrity. Determine a metal loss threshold for mandatory repairs. In the determination of mandatory repairs:a. Use a "first, do no harm" approach to classifying tank repairs.b. Use Desired Service Interval as the time to next inspection unless notified otherwise by the Contracting Officer.c. Use minimum remaining thickness (MRT) no less than 100 mils at the next inspection.d. Do not classify as mandatory repair of conditions which are noncompliant with current standards but are un-related to structural or hydraulic integrity (e.g., gouge, improper weld spacing, weld profile).e. Apply repair determination to individual indications. Do not average across an entire plate or

Scott AFB ,
 IL  62225  USALocation

Place Of Performance : N/A

Country : United StatesState : IllinoisCity : Scott Air Force Base

Classification

naicsCode 541990All Other Professional, Scientific, and Technical Services
pscCode H391Inspection and Laboratory Services (except medical/dental): Fuels, Lubricants, Oils, and Waxes