Sources Sought - Accelerated Summa Sampler System

expired opportunity(Expired)
From: Federal Government(Federal)
SS-AFRL-PZLEQ-2023-0017

Basic Details

started - 07 Aug, 2023 (8 months ago)

Start Date

07 Aug, 2023 (8 months ago)
due - 17 Aug, 2023 (8 months ago)

Due Date

17 Aug, 2023 (8 months ago)
Bid Notification

Type

Bid Notification
SS-AFRL-PZLEQ-2023-0017

Identifier

SS-AFRL-PZLEQ-2023-0017
DEPT OF DEFENSE

Customer / Agency

DEPT OF DEFENSE (708886)DEPT OF THE AIR FORCE (60449)AFMC (17421)AIR FORCE RESEARCH LABORATORY (2517)FA2396 USAF AFMC AFRL PZL AFRL PZLE (309)
unlockUnlock the best of InstantMarkets.

Please Sign In to see more out of InstantMarkets such as history, intelligent business alerts and many more.

Don't have an account yet? Create a free account now.

Sources Sought – Accelerated Summa Sampler System - Sources SoughtDescription: The Air Force Research Laboratory (AFRL) is performing market research for the requirement of Accelerated Summa Sampler System.This is a Sources Sought (SS) / Request for Information (RFI). This is not a pre-solicitation or solicitation or Request for Proposal (RFP) and is not to be construed as any commitment by the Government. This notice does not obligate the Government to award a contract and or pay for any bid and/or proposal preparation costs. The Government will not accept proposals at this time. This notice is not an offer by the Government to enter into a contract. Interested Small Business concerns must identify to the contracting officer their interest and capability to satisfy the Government's requirement by closing date listed. Responses will allow the Government to conduct an initial review of market capabilities in support of requirements identified in attached Statement of Work
document.Submission Details: All interested parties are encouraged to submit a response to this SS/RFI announcement. Responses should address the following questions:1. Company name, cage code, address, point of contact, phone number, and email address.2. Identification of whether the company is currently designated as a Small Business as defined in FAR Part 19.1 and the appropriate category (i.e. 8a, HubZone, etc.).3. Company description of relevant capability and experience to provide the identified item. A brief history of the organization.4. Company's potential teammates/subcontractors (if required to ensure success).5. What, if any, risks or unknowns would hinder industries ability to meet the requirements?The Government encourages you to submit any additional comments or suggestions that you would like to share.Capability package responses and questions shall be sent electronically to the primary and/or alternate Points of Contact.Be advised that all correspondence sent via e-mail shall contain a subject line that reads “Accelerated Summa Sampler System.” Note that e-mail filters at Wright-Patterson AFB are designed to filter e-mails without subject lines or with suspicious subject lines or contents (i.e., .exe, or .zip files). Therefore, if this subject line is not included, the e-mail may not get through the e-mail filters. Also be advised that .zip or .exe files are not allowable attachments and may be deleted by the e-mail filters at Wright-Patterson AFB. If sending attachments with e-mail, ensure only .PDF, .doc, docx, xls, or .xsls documents are sent. The e-mail filter may delete any other form of attachments.Primary Point of Contact: Andrew Hertel - andrew.hertel.3@us.af.milAlternate Point of Contact: Chris Stokes - chris.stokes.1@us.af.milRequirements/Salient Characteristics: This is a one-time purchase where the vendors shall provide an Accelerated Summa Sampler system with the below requirements:GC interface kit for Thermo, includingGC coverTransfer line mounting bracketGC cableGC interface kit for Agilent, includingGC coverTransfer line mounting bracketGC cableInstallation bundle, comprisingMinicontrollerKVM switch2-6L cans with evaluation standardsAir Tox; TO14A/TO-15/TO-15A; Soil Gas Bundle containing7200A turnkey pre-concentrator with SC flow path, 3 stage, with liquid nitrogen modules installedLoop injection valve, installedDiaphragm pump5 m USB cable4 inlet heated transfer line or canister autosamplerMillion Air Autosampler with 0.1cc sample/calibration standard loop and 0.25 cc internal standard loopSilonite valve option4 5400 Heaters for 3.5 inch L x 1⁄4 inch adsorbent Perkin Elmer tubes, 120 V10 500 mL vacuum bottles, deactivated with silonite coated valvesOven cleaning system to accommodate up to twelve 6L or 3.2L canisters and 40 MiniCans or Bottle-Vacs3100D control module with MD pump control6 L oven36/12 position manifold with MQT fittingsa molecular drag pump2-stage pumpSL2 cablehumidifier3100 Controller and instrument mounting bracketPrecision static diluter system operating at 90-250 VAC with full Silonite-D flow path, all 6 channels installed, a 5 m USB cable, and Win XP/Win7 and Win10 control software4700 Controller and instrument mounting bracketThermal transfer system with new flow control including 4-station thermal transfer system for transferring contents of a thermal desorption tube into a 500 ml bottle-vac.2 Extra long trays for 1L, 1.4l, and 2L minicans, 12 positionMicrobalve Can sampler, including 5 um silonite screw-on filter, sealing o-ring, sapphire, 1/4ODx 0.08” IDx 1.6” SS tube, Female microvalve1/4” face-sealing flowmate to male QT valve silonite-coated6 position canister tray for use with 7650-M and 7650-L 10 systems6 position 6L canister tray alignment tool for use with 6 pos 6L canister tray2 OS/76xx 18 position long trays for non-cooled 500 ml bottle1.4L Silonite coated MiniCan and coated True Seal Valve4 Short tray alignment pins4-day Installation and familiarization with per diem, airfare and travel time

Wright Patterson AFB ,
 OH  45433  USALocation

Place Of Performance : N/A

Country : United StatesState : OhioCity : WRIGHT PATTER

Classification

naicsCode 334516Analytical Laboratory Instrument Manufacturing
pscCode 6640Laboratory Equipment and Supplies