6530--Amarillo Nursing Ceiling Patient Lifts

expired opportunity(Expired)
From: Federal Government(Federal)
started - 12 Aug, 2022 (1 month ago)

Start Date

12 Aug, 2022 (1 month ago)
due - 12 Aug, 2022 (1 month ago)

Due Date

18 Aug, 2022 (1 month ago)
Bid Notification

Opportunity Type

Bid Notification
36C25722Q0670

Opportunity Identifier

36C25722Q0670
VETERANS AFFAIRS, DEPARTMENT OF

Customer / Agency

VETERANS AFFAIRS, DEPARTMENT OF
Thomas E Creek VA Medical Center  Amarillo ,
 TX  79106  USA

Location

Thomas E Creek VA Medical Center Amarillo , TX 79106 USA
unlockUnlock the best of InstantMarkets.
Please Sign In to see more out of InstantMarkets such as history, intelligent business alerts and many more.

Don't have an account yet? Create a free account now.

Contract Opportunity General Information Classification Description Attachments/Links Contact Information History Award Notices Follow 6530--Amarillo Nursing Ceiling Patient Lifts Active Contract Opportunity Notice ID 36C25722Q0670 Related Notice Department/Ind. Agency VETERANS AFFAIRS, DEPARTMENT OF Sub-tier VETERANS AFFAIRS, DEPARTMENT OF Office 257-NETWORK CONTRACT OFFICE 17 (36C257) General Information View Changes Contract Opportunity Type: Solicitation (Updated)All Dates/Times are: (UTC-05:00) CENTRAL STANDARD TIME, CHICAGO, USA Updated Published Date: Aug 12, 2022 09:45 am CDT Original Published Date: Jul 11, 2022 10:01 pm CDTUpdated Date Offers Due: Aug 18, 2022 10:00 am CDT Original Date Offers Due: May 27, 2022 10:00 am CDTInactive Policy: ManualUpdated Inactive Date: Sep 17, 2022 Original Inactive Date: Jul 26, 2022Initiative: None Classification Original Set Aside: Product Service Code: NAICS Code: 339113 - Surgical Appliance and Supplies ManufacturingPlace of Performance: Description View Changes Will the VA be increasing the weight capacity of the motors from 440lb to 550lb? Will NOT increase motors: Bldg 29 (CLC-A & CLC-B), ENDO Bldg 1: (3N) BLDG 28: 3S (east side), ICU BLDG 54: Rm 1924 (Bari Rm) Will increase motors: BLDG 1: Rm 2111C (Education Sim Rm) BLDG 28: Rm 1313 (x-ray rm), Rm 1316 (CT rm), Emergency Dept (hallways), 3S (west side), PACU Rm 4225 BLDG 29: Rm 1530 (CLC-A shower rm), Rm 1548A (bathroom), 2530 (CLC-B shower rm) BLDG 54: all Pt rooms and the Spa Rm BLDG 33: Rm 1401 (bathroom), Rm 1404B BLDG 46: Rm 1715, Rm 1730, Rm 1734 Will the VA be providing CAD drawings or reflective ceiling plans for the facility? No Is the VA staying with hand control charging or wanting to go to continuous charge? hand control charging Does the VA want integrated scales or lifts without scales? without scales According to the VA Safe Patient Handling and Mobility Design Criteria handbook (August 1, 2021), and following the direction of VISNs across the country, traverse (room-covering systems, with or without tracks into the bathroom) are the preferred design, with a minimum weight capacity of 550 lbs. (section 2.8.2.3 VA EQUIPMENT DESCRIPTION OVERHEAD RAIL SYSTEM). Is there a specific reason this facility requires a straight rail system, "which are of limited assistance in performing many high-risk patient handling tasks" (VA Safe Patient Handling and Mobility Design Criteria handbook section 2.8.2-1) and a restrictive weight capacity? Successful Offeror/Vendor/Contractor must provide a system that complies with the attached ceiling lift construction specification and Safe Patient Handling and Mobility Design Criteria: ceiling lift construction spec,  SPHM design criteria This statement of work / project, the way it is designed, depending on what manufacturer we are quoting, we would need to quote a different number of CLINS in the B.1 PRICE/COST SCHEDULE, therefore pricing totals would be very different / varying, amongst bidders. Will this be addressed/re-written? No Is this bid for a complete installation including all new rails? If your equipment is not what we already have, then yes Would the VA please split this solicitation due to the products being independently sold of each other. No; per our guidance we must use the lift manufacturer slings designed for their product Are drawings and/or architectural plans available? The SOW states drawings were posted with the announcement, but we do not find them in SAM. ceiling lift construction spec,  SPHM design criteria Are all of the existing track systems set up to be compatible with continuous charge lifts? No Regarding the rooms noted The current lifts are new and will not reach the end of life for 10 years. And will not be changed if the current manufacturer is used .  Does this mean every manufacturer other than Liko has to install a new lift? Yes; because we want standardization. Several of the rooms are noted with comments such as Need 2 steel supports , Need 4 steel supports . Are these comments referring to above ceiling attachment to structure? Successful Offeror/Vendor/Contractor must provide a system that complies with the attached ceiling lift construction specification and Safe Patient Handling and Mobility Design Criteria: ceiling lift construction spec,  SPHM design criteria Attachments/LinksDownload All Attachments/Links Attachments DocumentFile SizeAccessUpdated Date36C25722Q0670 0001_1.docx (opens in new window)21 KB PublicAug 12, 202236C25722Q0670 0001.docx (opens in new window)18 KB PublicJul 20, 202236C25722Q0670_3.docx (opens in new window)118 KB PublicJul 11, 2022file uploadsinfo alertPlease Request Role: This opportunity has controlled attachments. You need a role to access them. Request RoleContact Information Contracting Office Address 2301 E. LAMAR BLVD ARLINGTON , TX 76006 USA Primary Point of Contact Jesus Casiano Jesus.Casiano@va.gov Secondary Point of Contact HistoryAug 12, 2022 09:45 am CDTSolicitation (Updated)Jul 20, 2022 03:47 pm CDTSolicitation (Updated)Jul 11, 2022 10:01 pm CDTSolicitation (Original)

Dates

Start Date

12 Aug, 2022 (1 month ago)

Due Date

18 Aug, 2022 (1 month ago)

You may also like

FMS - Facilities: Patient Ceiling Lifts

Due: 15 Oct, 2022 (in 8 days)Agency: VETERANS AFFAIRS, DEPARTMENT OF

J065--Patient Ceiling Lifts Preventive Maintenance

Due: 28 Oct, 2022 (in 21 days)Agency: VETERANS AFFAIRS, DEPARTMENT OF

6530--GULDMANN GH3+ Ceiling Patient Lifts (VA-22-00068669)

Due: 15 Oct, 2022 (in 8 days)Agency: VETERANS AFFAIRS, DEPARTMENT OF
Please Sign In to see more like these.

Don't have an account yet? Create a free account now.

Location

Country : United StatesState : Texas