36C24821R0176 - Z1DA--NRM Tier 2 (PROJ: 573-CSI-104) BB - Renovate Radiology for for Equipment Installation - Solicitation

expired opportunity(Expired)
From: Federal Government(Federal)
36C24821R0176

Basic Details

started - 02 Sep, 2021 (about 2 years ago)

Start Date

02 Sep, 2021 (about 2 years ago)
due - 13 Sep, 2021 (about 2 years ago)

Due Date

13 Sep, 2021 (about 2 years ago)
Bid Notification

Type

Bid Notification
36C24821R0176

Identifier

36C24821R0176
VETERANS AFFAIRS, DEPARTMENT OF

Customer / Agency

VETERANS AFFAIRS, DEPARTMENT OF (103600)VETERANS AFFAIRS, DEPARTMENT OF (103600)248-NETWORK CONTRACT OFFICE 8 (36C248) (4788)
[object Object]

SetAside

SDVOSBC(Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14))

Attachments (16)

unlockUnlock the best of InstantMarkets.

Please Sign In to see more out of InstantMarkets such as history, intelligent business alerts and many more.

Don't have an account yet? Create a free account now.

Amendment 0003 to incorporate the following changes:1. EDIT SUBJECT to match the solicitation system errorZ1DA--NRM Tier 2 (PROJ: 573-CSI-104) BB - Renovate Radiology for for Equipment Installation - Solicitation2. EDIT PSC CODE changes in system from Y1DA Construct Hospitals and infirmaries to Z1DA- Maintenance of Hospitals and Infirmaries. all other terms remain the same. 3. CHANGE POP from 540 days from NTP to 365 days from NTP .4. PROVIDE SITE VISIT SIGN IN SHEET 5. PROVIDE UPDATED SPECS 01 00 00 GENERAL CONDITIONS6. Change Deductive bid items.REMOVE ITEM II (BID DEDUCT ALTERNATE NO. 1): Provide all Work described in ITEM I except modify the following items: Reduce the number of 2nd floor deck penetrations for return air ducts at rooms Angio #1 and Angio #2. Submit proposed duct consolidation plans that are the basis for the deduct amount. These plans must be coordinated with all other work occurring between the room ceilings and the deck, for review by the VA to help determine
the Alternate’s acceptance or not. Contract Duration is 540 calendar days after the NTP PRINCIPAL NAICS CODE: 236220 - Commercial and Institutional Building Construction PRODUCT/SERVICE CODE: Z1DA - Maintenance of Hospitals and InfirmariesREPLACE WITH ITEM II (BID DEDUCT ALTERNATE NO. 1): Deduct Angio Room 104 and Equipment Room 105 from the scope of the project as noted below:Perform required demolition in this area but do not provide interior wallboard (leave metal studs exposed), ceilings, finishes, nor equipment in Angio Room 104.Perform required demolition in this area but do not provide interior wallboard (leave metal studs exposed), ceilings, finishes, nor equipment in Equipment Room 105.Provide the door and viewing window of the Shared Control Room 106.  All finishes and elements required for Shared Control Room 106 will be complete as viewed from inside the control room.Construct and complete the wall and door to the Elevator Lobby so that it is finished when viewed from the elevator lobby.Install the double doors from Angio Room 104 to Corridor 103 with associated door controls and hardware.Where plumbing mains or branch piping (CW, HW, HW recirculation, steam, sanitary waste and vent, medical gas piping, etc.) pass through the noted deduction area and serve other areas outside of the deducted area these elements must be included in the base bid such that no elements outside of the deduct area are left inoperable.Do not provide scheduled lighting, power or systems work in this area except stub conduit scheduled to serve this area with pull strings back to the next junction box or panel outside of the deduct area. Provide life safety lighting in lieu of scheduled lighting to maintain minimum of ten foot-candles of light in the area.Construct supply air openings (Note 3 and 7 on Drawing M-201) for supply air ducts to second level mechanical room and close openings with fire rated damper.  Construct return air duct openings (Note 6, 15 and 20 on Drawing M-201) to second level mechanical room and close openings with fire rated damper. Ductwork on the second level is to be completed and penetrate the first-floor space at least twelve inches.  Cap open end of ductwork.Provide required fire protection mains, branch lines and piping to sprinkler heads except turn sprinkler heads up to deck as required to cover shelled area in accordance with NFPA requirements.Contract Duration is 365 calendar days after the NTP PRINCIPAL NAICS CODE: 236220 - Commercial and Institutional Building Construction PRODUCT/SERVICE CODE: Z1DA - Maintenance of Hospitals and Infirmaries** HOUR & DATE for Receipt of Offers is  SEPTEMBER 13, 2021  @ 1:00pm est

Gainesville ,
 FL  32608  USALocation

Place Of Performance : N/A

Country : United StatesState : FloridaCity : Gainesville

Classification

naicsCode 236220Commercial and Institutional Building Construction
pscCode Z1DAMAINTENANCE OF HOSPITALS AND INFIRMARIES