Page 1 of 5 ADDENDUM NO. 1 TO TERMINAL EXPANSION AIP 3-31-0045-036 (CARES) At KEARNEY REGIONAL AIRPORT (EAR) KEARNEY, NE Addendum Date: August 25,2022 To Prospective Bidders: The contract documents/specifications and plans for the above referenced project are hereby amended as follows: Specifications: Entry 1: Article 1 Contract Documents: Sheet NTB.3: Replace Table Footer Sentence “* Calendar days shown for Phases 1A,1B, 1C, and 1D shall be completed concurrently with the 187 Calendar Days of Phase 1. They are not in addition to.” in its entirety with sentence, “* Calendar days shown for Phases 1A,1B, 1C, and 1D shall be completed concurrently with the 224 Calendar Days of Phase 1. They are not in addition to.” This change accurately shows the correct number of calendar days in phase 1. Entry 2: Article 4 FAA General Contract Provision: Section 70-21 Insurance Requirements (Sheet GP-70.7): Replace Paragraph (v) Builder’s Risk Insurance in its entirety with the following paragraph:
Builder’s Risk Insurance – Contractor shall purchase and maintain property insurance upon the Work at the Site in the amount of the full replacement cost thereof. 1. This insurance shall: a. include the interests of Owner, Contractor, Subcontractors, Engineer and any other individuals or entities identified herein, and the officers, directors, partners, employees, agents and other consultants and subcontractors of any of them each of whom is deemed to have an insurable interest and shall be listed as an insured or additional insured; b. in addition to the individuals and entities specified, include as additional insureds, the following: 1) City of Kearney (Kearney, NE), Alfred Benesch & Company, Wilkins Architecture Design Planning, Morrissey Engineering Inc, Lange Structural Group; c. be written on a Builder's Risk "ail-risk" / Installation Floater, or open peril or special causes of loss policy form that shall at least include insurance for physical loss and damage to the Work, temporary buildings, false work, and materials and equipment in transit; d. include expenses incurred in the repair or replacement of any insured property (including but not limited to fees and charges of engineers and architects); e. cover materials and equipment stored at the Site or at another location that was agreed to in writing by Owner prior to being incorporated in the Work, provided that such materials and equipment have been included in an Application for Payment recommended by Engineer; f. allow for partial utilization of the Work by Owner; g. include testing and startup; and Page 2 of 5 h. be maintained in effect until final payment is made unless otherwise agreed to in writing by Owner, Contractor and Engineer with 30 days written notice to each other additional insured to whom a certificate of insurance has been issued. 2. Contractor shall be responsible for any deductible or self-insured retention. Entry 3: Article 4 FAA General Contract Provision: Section 80-08 Insurance Requirements (Sheet GP-80.4): Replace Table Footer Sentence “* Calendar days shown for Phases 1A,1B, 1C, and 1D shall be completed concurrently with the 187 Calendar Days of Phase 1. They are not in addition to.” in its entirety with sentence, “* Calendar days shown for Phases 1A,1B, 1C, and 1D shall be completed concurrently with the 224 Calendar Days of Phase 1. They are not in addition to.” This change accurately shows the correct number of calendar days in phase 1. Entry 4: Article 5 Sheet B-102.2, replace specification section B-102 Construction Staking, Paragraph 102-2.2 in its entirety with the following. 102-2.2 Contractor Provided Construction Control Monuments. The Contractor will provide the following control monuments: • Two (2) horizontal and vertical control monuments for pavement and building construction. Two (2) additional horizontal and vertical control monuments may be required for construction of the Airside Inlet at Sta 1+25.00 if requested by the RPR. Entry 5: Article 5 Sheet B-105.1: Replace Payment Item “4” Sanitary Sewer, Directionally Bored – per linear foot” in its entirety with “4” Sanitary Sewer – per linear foot”. Entry 6: Article 6 City of Kearney Standard Construction Specifications Section 11: Replace the following line in Paragraph 11.30 A. “A test supplied by the Contractor from an approved laboratory, will be required for each type of excavation or borrow material encountered.” with “The City’s Testing Firm (Benesch) will perform density tests to verify acceptable moisture and compaction. The Contractor shall not include costs for these tests in their bid.” Entry 7: Appendix 2 Section 013000 – ADMINISTATIVE REQUIREMENTS – BUILDING ONLY, Section 3.2 Progress Meetings: Add Subsection 3.2.A.1 as follows for clarification of the frequency of Progress Meetings to be conducted by the Project Coordinator (General Contractor).: 3.2.A.1 Progress Meetings shall be conducted on a bi-weekly basis (every two weeks). Entry 8: Appendix 2 Section 233113 – METAL DUCTS AND ACCESSORIES, Section 2.1 Manufacturers: Subject to compliance with the specifications, add the following to the list of approved manufacturers. -Section 4. Diffusers, Registers, Grilles: Add “Metalaire” -Section 5: Louvers: Add “Air Balance” and “Louvers & Dampers” Page 3 of 5 Entry 9: Appendix 2 Section 233423 – POWER VENTILATORS, Section 2.1 Manufacturers: Subject to compliance with the specifications, add the following to the list of approved manufacturers. -Section 1. Ceiling-Mounted Ventilators: Add “Soler & Palau” and “TCF Aerovent” -Section 2: In-line Centrifugal Fans: Add “Soler & Palau” and “TCF Aerovent” Entry 10: Appendix 2 Section 238126 – SPLIT-SYSTEM AIR-CONDITIONING UNITS, Section 2.1 Manufacturers: Subject to compliance with the specifications, add the following to the list of approved manufacturers. - Samsung Plans: Entry 11: Plan Sheet Drawing No. CSPP.3 (C8/C35): Replace the first Phase Schedule Note, “THE PROJECT HAS A TOTAL CALENDAR DAY DURATION OF 283 CALENDAR DAYS. REFER TO ARCHITECTURAL PLAN SHEETS FOR PHASE 2 PHASING AND SCOPE OF WORK.” In its entirety with “THE PROJECT HAS A TOTAL CALENDAR DAY DURATION OF 320 CALENDAR DAYS. REFER TO ARCHITECTURAL PLAN SHEETS FOR PHASE 2 PHASING AND SCOPE OF WORK.” Entry 12: Plan Sheet Drawing No. GR-1 (Sheet C18/C35), Plan Sheet Drawing No. P.1 (Sheet C25/C35), Plan Sheet Drawing No. P.2 (Sheet C26/C35), Plan Sheet Drawing No. EC.1 (Sheet C33/C35) and Plan Sheet Drawing No. L.1 (Sheet C35/C35): Exterior sidewalks west of new Mechanical (122) Room, between the ‘green space’ and building will be adjusted from a 4’ width to a 5’ width. The Contractor shall coordinate with the Resident Project Resident to adjust the locations of sidewalk, landscape benches and landscaping to provide for the 5’ width sidewalk. Entry 13: Plan Sheet Drawing No. L-1 (Sheet C35/C35): Add the following note to the Landscaping Plan. 5. ALL AREAS WHERE PROPOSED LANDSCAPING IS TO BE COMPLETED SHALL INCLUDE ROCK LANDSCAPE BEDS THAT MATCH EXISTING TYPE AND SIZE OF ROCK AS EXISTING LANDSCAPING. Entry 14: Plan Sheet Drawing No. A1.0: Add urinal and wall type A.1 to east wall of Family Restroom 136. Revise dimensions at and between Family Restroom 116 and Family Restroom 136. See revcloud on reissued plan A1.0 sheet attached (Attachment No. 1) to this addendum. Entry 15: Plan Sheet Drawing No. A2.0: Add urinal and wall type A.1 to east wall of Family Restroom 136. Revise dimensions at and between Family Restroom 116 and Family Restroom 136. See revcloud on reissued plan A2.0 sheet attached (Attachment No. 2) to this addendum. Entry 16: Plan Sheet Drawing No. A9.3: Revise elevations for added urinal at Interior Elevations 9/A9.3 Family Restroom 136 – E and 11/A9.3 Family Restroom 136 – S. See revcloud on reissued plan A9.3 sheet attached (Attachment No. 3) to this addendum. Page 4 of 5 Entry 17: Plan Sheet Drawing No. S2.1: Callouts were added for shear wall locations and existing footing modification notes. See revcloud on reissued plan S2.1 sheet attached (Attachment No. 4) to this addendum. Entry 18: Plan Sheet Drawing No. M1.1: Add EH-101A and EH-101B to Vestibule 101. Add thermostat to control heaters. Add keynotes M121 and M122. See revcloud on reissued plan M1.1 sheet attached (Attachment No. 5) to this addendum. Entry 19: Plan Sheet Drawing No. M1.2: Revise gas piping sizes. Add gas pressure regulators at existing RTUs. See revcloud on reissued plan M1.2 sheet attached (Attachment No. 5) to this addendum. Entry 20: Plan Sheet Drawing No. M2.0: Revise sanitary piping for added urinal in Family Restroom 136. See revcloud on reissued plan M2.0 sheet attached (Attachment No. 5) to this addendum. Entry 21: Plan Sheet Drawing No. M2.1: Revise gas piping sizes. Add pressure regulator replacement by Northwestern Energy to deliver 2 PSI gas to the building. Add water and vent piping to added UR-1. Remove meter from irrigation line. Revise condensate to AC- 118. See revcloud on reissued plan M2.1 sheet attached (Attachment No. 5) to this addendum. Entry 22: Plan Sheet Drawing No. M3.1: Revise riser diagram for added UR-1. See revcloud on reissued plan M3.1 sheet attached (Attachment No. 5) to this addendum. Entry 23: Plan Sheet Drawing No. M4.1: Add detail 16. Add pressure regulator to detail 11. See revcloud on reissued plan M4.1 sheet attached (Attachment No. 5) to this addendum. Entry 24: Plan Sheet Drawing No. M5.1: Add EH-101A and EH-101B to Electric Heater Schedule. See revcloud on reissued plan M5.1 sheet attached (Attachment No. 5) to this addendum. Entry 25: Plan Sheet Drawing No. M5.2: Add UR-1 to Plumbing Fixture Schedule. Remove trap primer connection from D-1 and add trap guard. See revcloud on reissued plan M5.2 sheet attached (Attachment No. 5) to this addendum. Entry 26: Plan Sheet Drawing No. E2.1: Remove floor box and ceiling power installations. Add power pole location with receptacles and data outlets. Add keynote E255. Remove alarm repeater receptacle location, keynote E204. Add electric heaters in Vestibule 101. See revcloud on reissued plan E2.1 sheet attached (Attachment No. 6) to this addendum. Entry 27: Plan Sheet Drawing No. E3.1: Remove floor box data installations. Revise termination location of data cabling from floor to power pole location. See revcloud on reissued plan E3.1 sheet attached (Attachment No. 6) to this addendum. Entry 28: Plan Sheet Drawing No. E6.1: Revise mechanical connection schedule. Add note #8 to schedule. See revcloud on reissued plan E6.1 sheet attached (Attachment No. 6) to this addendum. Entry 29: Plan Sheet Drawing No. E6.1: Add general requirement (B.) to luminaire schedule. See revcloud on reissued plan E6.1 sheet attached (Attachment No. 6) to this addendum. Entry 30: Plan Sheet Drawing No. E6.2: Revise schedule for Panel LP3. See revcloud on reissued plan E6.2 sheet attached (Attachment No. 6) to this addendum. Page 5 of 5 Other: Entry 31: Attached to this addendum is a document titled “TSA SYSTEM INTEGRATORS” (Attachment No. 7) That contains the contact information for subcontractors that can be utilized for the Passenger and Baggage Checkpoint Screening Equipment Relocation. Entry 32: Attached to this addendum is a document titled “Existing TSA Checkpoint Equipment Inventory” (Attachment No. 8) That contains the current list of TSA equipment in the existing terminal building. Entry 33: As of August 24, 2022, the Davis Bacon Wage Rate “General Decision Number: NE20220066 07/08/2022” (Construction Type: Building) is still current As of August 24, 2022, the Davis Bacon Wage Rate “General Decision Number: NE20220047 02/25/2022” (Construction Type: Heavy) is still current. Entry 34: Attached to this addendum is the current plan holders list (as of August 24, 2022) for reference (Attachment No. 9). Entry 35: Attached to this addendum is the Agenda for the Pre-Bid Meeting that was conducted on Tuesday, August 23. (Attachment No. 10) END OF CHANGES PER ADDENDUM NO. 1 Prepared by: Alfred Benesch & Company Signature of Preparer: _________________ 825 “M” Street, Suite 100 Lincoln, NE 68508 (402) 479-2200 FAX: (402) 479-2276 TERMINAL EXPANSION KEARNEY REGIONAL AIRPORT (EAR) KEARNEY, NEBRASKA AIP 3-31-0045-036 (CARES) ADDENDUM NO. 1 ATTACHMENT NO. 1 Revised Plan Sheet Drawing A1.0 1. EXISTING GYPSUM WALL BOARD FINISH TO REMAIN, PATCH AND REPAIR AS REQUIRED, SKIMCOAT AND PREP FOR PAINT FINISH; SEE DEMOLITION SHEET AD1.0 AND ROOM FINISH SCHEDULE A9.0 2. EXISTING EQUIPMENT TO REMAIN; PROVIDE TENTING AND TEMPORARY WALLS AS REQUIRED TO KEEP ROOM AND EQUIPMENT CLEAN OF ANY CONSTRUCTION DUST AND DEBRIS 3. REINSTALL EXISTING KNOX BOX 4. PROVIDE PAINTED 5/8" GWB FINISH AT WALL OPENING FOR COMPLETE FINISH AT ALL EXPOSED SURFACES 1. EXISTING BUILDING ELEMENTS TO REMAIN ARE SHOWN HALF-TONED (GRAY); SEE CIVIL AND DEMOLITION PLANS FOR PROJECT PHASING. 2. SEE EXTERIOR ELEVATIONS AND WALL SECTIONS FOR ADDITIONAL DIMENSIONS. A5.0 4 A5.01 A5.0 5 A5.0 2 6 A6.0 TSA WORK AREA 123 TSA BREAK ROOM 125 TSA OFFICE 128 TSA DATA 124 TSA OFFICE 127 PRIVATE SCREENING ROOM 129 OFFICE 108 A2.0 1 2 A6.0 3 A6.0 5 A6.0 4 A6.0 EX. 5 EX. 4 EX. 3 EX. 2 EX. A EX. C EX. D EX. EEX. B.9 EX. D.2 124 VESTIBULE 101 - 1 1 /2 " 5' - 10 1/2" 18' - 5 1/4" 2' - 0" 23' - 0" 5' - 6 3/8" 18' - 5 5/8" 24' - 0 1/8" 5' - 0" 5' - 8" 9' - 5" 15' - 5" 11' - 6 9/16" 9' - 3 5/16" 7' - 6 11/16" 9' - 4 7/8" 11' - 2 9/16" 10' - 6 1/2" 11' - 11 3/4" INBOUND BAGGAGE 104 BAGGAGE CLAIM 105 AIRPORT STORAGE 105A RENTAL DESK 106 RENTAL OFFICE 107 OFFICE 109 LOBBY CONCOURSE 102 ARRIVALS VESTIBULE 103 TICKETING 110 TSA BAG SCREENING 118 OUTBOUND BAGGAGE 119 NON-SECURE WAITING 111 AIRLINE OFFICE 113 RESTROOM 114 RESTROOM 115 RESTROOM 135 RESTROOM 134 ALCOVE 133 BOARDING 132 SECURE HOLDROOM WEST 137 FAMILY RESTROOM 136 FAMILY RESTROOM 116 TSA PASSENGER QUEUING 120 TSA ENTRY 126 MECHANICAL 122 15' - 11 3/4" V.I.F. 15' - 11 3/4" 7 ' - 4 " 1 1 ' - 6 " 4 5 /8 " 1 ' - 1 0 " 1 ' - 1 0 " 7 ' - 5 1 /2 " 6' - 9 3/8" 6' - 9 3/8" 5 7 /8 " 5 ' - 3 3 /4 " 9 ' - 5 " 1 0 ' - 6 1 /2 " 2 ' - 6 " 1 0 ' - 6 " 6 ' - 1 1 /2 " 17' - 11 1/2" 6' - 4 3/4" 12' - 11 1/2" 11' - 4 3/4" 6 ' - 0 3 /4 " 4 ' - 0 3 /4 " 9 ' - 6 3 /4 " 1 2 ' - 7 1 /2 " 7 ' - 0 3 /4 " 8' - 6 3/4" 1 2 ' - 1 3 /4 " 2 0 ' - 4 3 /4 " 1 0 ' - 3 1 /2 " 8 ' - 1 0 " 7 " 9 ' - 5 " 1 5 ' - 3 1 /4 " 5 7 /8 " 4 ' - 2 " 8 ' - 0 1 /8 " 2 0 ' - 0 " 5 ' - 7 " V .I .F . 9 ' - 5 1 /4 " 1 9 ' - 1 1 /2 " 2 5 ' - 9 1 /8 " 4 4 ' - 1 0 5 /8 " A10.1 5 A10.1 4 A9.3 4 A10.1 2 A10.0 12 A9.2 8 A9.314 A9.2 9 11 10 A9.3 1 MECHANICAL M150 3 A7.1 TSA CHECKPOINT 121 SECURE HOLDROOM 130 SECURE HOLDROOM EAST 131 1 A7.2 7 A6.0 1 A6.0 EX. F 1 1 2 2 3 3 EX. 1 EX. 1 EX. B A B C A9.3 15 FE FE CG CG CGCG CG CG CG CG CG CG CG2 CG CG CG2 CG CG2 CG CG CG CGCG CG CG CG CG CG CG CG CG AED 1 0 1 1 0 9 1 0 7 1 0 4 C 1 1 9 A 1 1 9 B 132 120 1 1 6 1 3 6 129 1 2 1 122 1 2 6 B 1 2 6 A 127 1 2 3 128 4 A7.0 1 A7.1 3 A7.2 2 A7.1 3 A7.0 2 A7.0 1 A7.0 4 A7.2 5 A7.2 5 A7.0 103A EW1 EW1 EW2 EW2 EW2 EW2 EW1 EW1 EW-3 EW-3 4 A7.1 7 2 A7.2 CLEAR 1' - 6" 1 1 1 1 4 4 4 4 1 1 2 3 118C E 1 0 8 E104B E 1 1 8 B E 1 3 3 E113 E 1 1 0 E117 CUST. 117 E 1 0 4 A A9.3 2 A B C D F E J G H H G GHH G GH H G E F F E 1 1 1' - 0" 1 ' - 0 " 1' - 0" 3 ' - 0 " 1' - 0" 8 " 1 0 4 D E103B E E 1 1 8 A A A A FA-1FA-1 A A A B A A B A B B.1 A.1 A.1 A.1 A.1 A.1 A.1 A.1 A.1 A.1 A.1 A.1 B.3 A.1 A.1 A.1 B.3 B.3 A EW2.1 13' - 4 3/4" 9' - 0 3/4" 14' - 10 7/8" V.I.F. 10' - 11 5/8" B B HALLWAY 112 35' - 6" 49' - 0" 8 " 5" 9 1/4" 11' - 2 3/4" 7' - 0" 4' - 5 3/4" 1 0 ' - 0 " 1 6 ' - 5 7 /8 " 1 0 ' - 0 " 4 ' - 6 7 /8 " 1 3 ' - 5 " V .I .F . 4 7 ' - 2 3 /8 " 4 4 ' - 1 0 5 /8 " EW2.1 A9.213 CGCG 2 5 ' - 1 0 1 /2 " 2 6 ' - 4 " 2 7 ' - 9 1 /4 " 2 0 ' - 0 3 /8 " 5 7 /8 " 2 5 ' - 3 1 /4 " 1 9 ' - 1 1 /2 " 1 4 4 ' - 1 0 3 /4 " 97' - 3 7/8" 84' - 6" A.1 1 SHEET NO. DATE PROJECT KEARNEY TERMINAL SEAL NO . RE VI SI ON S DA TE CIVIL ENGINEER DR AW N BY : DE SI GN ED BY : RE VI EW ED BY : QU AN TI TI ES CH EC KE D BY : ARCHITECT CONSULTANT K E A R N E Y R E G IO N A L A IR P O R T T E R M IN A L E X P A N S IO N K E A R N E Y , N E B R A S K A 07/29/2022 A1.0 Ov er all Fl oo r P lan A d d e nd um # 1 8 / 2 4 / 2 0 2 2 FLOOR PLAN - KEYED NOTESFLOOR PLAN GENERAL NOTES SCALE:N 1/8" = 1'-0"A1.0 1 FLOOR PLAN - GROUND FLOOR TERMINAL EXPANSION KEARNEY REGIONAL AIRPORT (EAR) KEARNEY, NEBRASKA AIP 3-31-0045-036 (CARES) ADDENDUM NO. 1 Attachment No. 2 Revised Plan Sheet Drawing A2.0 EX. 2 EX. C EX. DEX. B.9 EX. D.2 7 ' - 1 1 " 7' - 6" 1' - 0" FAMILY RESTROOM 116 SECURE HOLDROOM WEST 137 FAMILY RESTROOM 136 A9.3 7 58 6 A9.3 11 912 10 A9.3 3 A J A B J B C C E E D D A.1 B.3 B.3 A.1 A.1 B.3 M LK K L M 9' - 2 1/2" 9 1/8" 1' - 0 1/8"1' - 0"7' - 8" 1' - 0"4 3/4" CG CG CG 14' - 10 7/8" 1 3 6 1 1 6 6 3 /4 " 4 ' - 4 " 1 0 " 2 ' - 6 " 3 " 4 1 /8 " 6 3 /4 " 4 ' - 4 " 1 0 " 2 ' - 6 " 3 " 4 1 /8 " 9' - 2 1/2" A.1 A.1 3 ' - 6 " 1 ' - 6 " 1 T O S P O U T 3 6 " 3 9 5 /8 " ELECTRIC WATER COOLERS; SURFACE MOUNTED 17" - 19" ( 2 7 " M IN . ) 2 9 1 /2 " FIRE EXTINGUISHER CABINET WASTE RECEPTACLE FEMININE NAPKIN DISPENSER M A X . R E A C H 4 8 " T .O . C O N T R O L S 4 8 " M A X . 8 0 " FULL HEIGHT MIRROR T .O . C A B IN E T 5 4 " 4 6 5 /8 " 4 2 1 /2 " 42" MAX. 12" 3 6 " 1 6 " - 1 8 " A D A 1 7 " M IN . SIDE ELEVATION PLAN VIEW NOTE: PROVIDE BLOCKING AS REQ'D FOR WALL MOUNTED EQUIPMENT FLUSH CONTROL ON OPEN SIDE 3 3 " - 3 6 " A D A 3 4 " T .O . B A R GRAB BAR (TYP) GRAB BAR (TYP) FEMININE NAPKIN DISPOSAL 1 7 " A D A 1 9 " S T A N D A R D 1 7 " M IN . A D A FRONT ELEVATION 36" 24" MIN. 12" GRAB BAR (TYP) 3 3 " - 3 6 " A D A 3 4 " T .O . B A R B .O . F IX T U R E S 4 0 " T .O . S IN K 3 4 " MIRROR 3 " TOILET PAPER DISPENSER 1 5 " - 4 8 " A D A 2 4 " ADA 7" - 9" SOAP DISPENSER ADDITIONAL DISPENSER; LOCATE 12" (MIN.) FROM ALL ELEC RECEPTACLES; CONFIRM FINAL LOCATION w/ OWNER/ARCHITECT PRIOR TO INSTALL 2 4 " S T A N D A R D 7 1 /2 " MIN. CLEAR SPACE 30" CENTERED ON SINK U R IN A L 39" - 41" ANSI 40" C/L BAR GRAB BAR (TYP) 3 9 " - 4 1 " A N S I 4 0 " B .O . B A R 1 8 " M IN . 2 4 " M IN . 1 2 " 3 9 " - 4 1 " A N S I 4 0 " B .O . B A R SHEET NO. DATE PROJECT KEARNEY TERMINAL SEAL NO . RE VI SI ON S DA TE CIVIL ENGINEER DR AW N BY : DE SI GN ED BY : RE VI EW ED BY : QU AN TI TI ES CH EC KE D BY : ARCHITECT CONSULTANT K E A R N E Y R E G IO N A L A IR P O R T T E R M IN A L E X P A N S IO N K E A R N E Y , N E B R A S K A 07/29/2022 A2.0 En lar ge d Flo or P lan s A d d e nd um # 1 8 / 2 4 / 2 0 2 2 SCALE:N 3/8" = 1'-0"A2.0 1 ENLARGED FLOOR PLAN ACCESSORY/ EQUIPMENT SCHEDULE KEY NOTE TYPE MANUFACTURER MODEL COMMENTS A BABY CHANGING STATION KOALA KARE KB311-SSWM CONTRACTOR PROVIDED AND INSTALLED B 36" GRAB BAR BOBRICK B-6806x36 CONTRACTOR PROVIDED AND INSTALLED C 42" GRAB BAR BOBRICK B-6806x42 CONTRACTOR PROVIDED AND INSTALLED D 24"X36" MIRROR BOBRICK B-169 2436 SEE ELEC. DRAWINGS E 24"X72" MIRROR BOBRICK B-290 2472 CONTRACTOR PROVIDED AND INSTALLED I SOAP DISPENSER BRADLEY 6562 OWNER PROVIDED AND INSTALLED J SEMI-RECESSED PAPER TOWEL & TRASH RECEPTACLE BOBRICK B-43944 CONTRACTOR PROVIDED AND INSTALLED K SANITARY NAPKIN DISPOSAL BOBRICK B-254 CONTRACTOR PROVIDED AND INSTALLED L TOILET TISSUE DISPENSER BRADLEY 5126 CONTRACTOR PROVIDED AND INSTALLED M 18" VERTICAL GRAB BAR BOBRICK B-6806x18 CONTRACTOR PROVIDED AND INSTALLED N PAPER TOWEL DISPENSER BOBRICK B-4262 OWNER PROVIDED AND INSTALLED ACCESSORY AND FIXTURE LAYOUTACCESSIBLE FIXTURES AND ACCESSORIES TERMINAL EXPANSION KEARNEY REGIONAL AIRPORT (EAR) KEARNEY, NEBRASKA AIP 3-31-0045-036 (CARES) ADDENDUM NO. 1 Attachment No. 3 Revised Plan Sheet Drawing A9.3 4 ' - 8 " PAINT (P-3); (TYP) WALL BASE (WB-1); (TYP) ACOUSTIC PANEL (AP-1, AP-2); SEE A9.0 FOR PATTERN REPEAT 4 ' - 0 " TRIM ACOUSTIC PANEL TIGHT TO WALL (TYP) V.I.F. 17' - 1" V .I .F . 8 ' - 8 " WALL BASE (WB-1); (TYP) CUSTOM WALLCOVERING (WC-2); EXTEND FULL LENGTH OF WALL (V.I.F.) COORDINATE ELEC. FIXTURES WITH WALLCOVERING; CUT SEAMS TIGHT TO EDGE OF FIXTURE (TYP.) BJ D 1 ' - 0 " 5 ' - 0 " 6 " 1' - 6" 2' - 1" WALL TILE (WT-2); (TYP) WALL TILE (WT-1); (TYP) WALL BASE (WB-2); (TYP) TRIM (TR-4); (TYP) PAINT (P-1); (TYP) WALL TILE (WT-2); (TYP) WALL TILE (WT-1); (TYP) WALL BASE (WB-2); (TYP) 1 ' - 0 " 5 ' - 0 " 6 " TRIM (TR-4); (TYP) PAINT (P-1); (TYP)CJ; (TYP) C E L K M WALL TILE (WT-2); (TYP) WALL TILE (WT-1); (TYP) WALL BASE (WB-2); (TYP) 6 " 5 ' - 0 " 1 ' - 0 " TRIM (TR-4); (TYP) PAINT (P-1); (TYP) A WALL TILE (WT-2); (TYP) WALL TILE (WT-1); (TYP) WALL BASE (WB-2); (TYP) 1 ' - 0 " 5 ' - 0 " 6 " TRIM (TR-4); (TYP) PAINT (P-1); (TYP) A WALL TILE (WT-2); (TYP) WALL TILE (WT-1); (TYP) WALL BASE (WB-2); (TYP) 1 ' - 0 " 5 ' - 0 " 6 " TRIM (TR-4); (TYP) PAINT (P-1); (TYP) 3' - 6" 1' - 6" WALL TILE (WT-2); (TYP) WALL TILE (WT-1); (TYP) WALL BASE (WB-2); (TYP) CJ; (TYP) 1 ' - 0 " 5 ' - 0 " 6 " TRIM (TR-4); (TYP) PAINT (P-1); (TYP) C E L K M WALL TILE (WT-2); (TYP) WALL TILE (WT-1); (TYP) WALL BASE (WB-2); (TYP) 6 " 5 ' - 0 " 1 ' - 0 " TRIM (TR-4); (TYP) PAINT (P-1); (TYP) JB D 2' - 1" 1' - 6" WALL TILE (WT-2); (TYP) WALL TILE (WT-1); (TYP) WALL BASE (WB-2); (TYP) 1 ' - 0 " 5 ' - 0 " 6 " 2' - 7 3/4" 4' - 0" 3' - 11"3' - 3 7/8" EQ EQ EQ EQ EQ EQ EQ EQ 3' - 4 3/8"EQEQ2' - 5 1/2" WALLCOVERING (WC-1); (TYP) CJ (TYP) CJ (TYP) CJ (TYP) CJ (TYP) WALL BASE (WB-1); (TYP) 4 " FLAT SCREEN TV; SEE A/V WALLCOVERING SEAM (TYP) 6' - 4 1/4" 6 ' - 1 0 " 7' - 8 5/8" S E E A /V 4 ' - 1 0 " 3' - 0" 3' - 0" 3' - 0" 2" REF. N.I.C. FE I N 3 ' - 0 " 1 ' - 1 0 " 2 ' - 1 0 " CG CG WALL BASE (WB-1); (TYP) 2' - 10" 1 ' - 8 " 1 ' - 4 " 2 A10.0 1 A10.0 3 A10.0 PAINT (P-1); (TYP) PAINT (P-1); (TYP) CJ; (TYP) MICRO. N.I.C. 2" 3' - 9" 4 " 2 ' - 1 0 " VENDING MACHINE (N.I.C.) VENDING MACHINE (N.I.C.) WALL BASE (WB-1); (TYP) 4 A10.0 PAINT (P-1); (TYP) FILLER QUARTZ COUNTERTOP (QZ-1) PLASTIC LAMINATE (PL-1) PAINT (P-3); (TYP) WALL BASE (WB-1); (TYP) ACOUSTIC PANEL (AP-1, AP-2); SEE A9.0 FOR PATTERN REPEAT 4 ' - 8 " 4 ' - 0 " TRIM ACOUSTIC PANEL TIGHT TO WALL (TYP) CG CG CG CG PAINT (P-1); (TYP) OPEN TO BEYONDOPEN TO BEYOND WALL BASE (WB-1); (TYP) FLAT SCREEN TV; SEE A/V 8' - 4 5/8" S E E A /V 4 ' - 7 1 /2 " SHEET NO. DATE PROJECT KEARNEY TERMINAL SEAL NO . RE VI SI ON S DA TE CIVIL ENGINEER DR AW N BY : DE SI GN ED BY : RE VI EW ED BY : QU AN TI TI ES CH EC KE D BY : ARCHITECT CONSULTANT K E A R N E Y R E G IO N A L A IR P O R T T E R M IN A L E X P A N S IO N K E A R N E Y , N E B R A S K A 07/29/2022 A9.3 In te rio r E lev at io ns A d d e nd um # 1 8 / 2 4 / 2 0 2 2 SCALE: 3/8" = 1'-0"A9.3 3 INT. ELEV. - SECURE HOLDROOM WEST 137 - N SCALE: 3/8" = 1'-0"A9.3 4 INT. ELEV - SECURE HOLDROOM 130 - N SCALE: 3/8" = 1'-0"A9.3 5 INT. ELEV. - FAMILY RESTROOM 116 - E SCALE: 3/8" = 1'-0"A9.3 6 INT. ELEV. - FAMILY RESTROOM 116 - N SCALE: 3/8" = 1'-0"A9.3 7 INT. ELEV. - FAMILY RESTROOM 116 - S SCALE: 3/8" = 1'-0"A9.3 8 INT. ELEV. - FAMILY RESTROOM 116 - W SCALE: 3/8" = 1'-0"A9.3 9 INT. ELEV. - FAMILY RESTROOM 136 - E SCALE: 3/8" = 1'-0"A9.3 10 INT. ELEV. - FAMILY RESTROOM 136 - N SCALE: 3/8" = 1'-0"A9.3 11 INT. ELEV. - FAMILY RESTROOM 136 - S SCALE: 3/8" = 1'-0"A9.3 12 INT. ELEV. - FAMILY RESTROOM 136 - W SCALE: 3/8" = 1'-0"A9.3 1 INT. ELEV. - TSA CHECKPOINT 121 -S SCALE: 3/8" = 1'-0"A9.3 13 INT. ELEV. - TSA BREAK ROOM 125 - N SCALE: 3/8" = 1'-0"A9.3 14 INT. ELEV. - SECURE HOLDROOM WEST 137 -W SCALE: 3/8" = 1'-0"A9.3 15 INT. ELEV. - SECURE HOLDROOM EAST 131 -S SCALE: 3/8" = 1'-0"A9.3 2 INT. ELEV. - SECURE HOLDROOM 130 - E 1 1 TERMINAL EXPANSION KEARNEY REGIONAL AIRPORT (EAR) KEARNEY, NEBRASKA AIP 3-31-0045-036 (CARES) ADDENDUM NO. 1 Attachment No. 4 Revised Plan Sheet Drawing S2.1 NOTES 1. 2. 3. 4. 5. REFER TO DESIGN DATA, SCHEDULES & TYP DETAILS INDICATES SHEET NOTE REFER TO PLAN FOR LOCATION TOF = 99'-4" UNLESS NOTED OTHERWISE COLUMN SCHEDULE GUIDE C-X COLUMN MARK BP-X BASE PLATE MARK F-X FOOTING MARK XX'-X TOP OF FOOTING INDICATES HOLDDOWN SIMPSON HDU2-SDS2.5 UNLESS NOTED OTHERWISE 4" CONCRETE ON PROPERLY PREPARED GRANULAR FILL & SUBGRADE REFER TO SOILS REPORT. REINFORCE w/ 6x6-W1.4xW1.4 WWF. REFER TO ARCH FOR VAPOR BARRIER. 6 # DOWEL FOOTING REINF INTO EXISTING FND DRILL & ADHERE w/ HILTI HIT-HY 200 w/ 9" EMBED DRILL VERTICAL DOWELS 3" INTO STOOP SLAB ADHERE w/ HILTI HIT-HY 200 ALL EXTERIOR WALLS ARE CONSIDERED SHEAR WALLS, ADDITIONALLY ALL WALLS BETWEEN HOLD DOWNS (INDICATED BY MARK SW) SAWCUT NOTCH IN EXISTING FOOTING FOR RESTROOM PLUMBING, NOT TO EXCEED 8"x8"x8" IN SIZE. 7 8 9. 10 1 EX. 5 EX. 5 EX. 4 EX. 4 EX. 3 EX. 3 EX. 2 EX. 2 10'-8" 7'-10" EX. A EX. B EX. C EX. D EX. EEX. B.9 EX. D.2 2 5 '- 1 0 3 /8 " 2 6 '- 4 " 2 7 '- 9 1 /4 " 2 0 '- 0 3 /8 " 2 5 '- 9 1 /8 " 1 9 '- 1 1 /2 " 73'-7 3/4" 5'-10 1/8" 18'-5 5/8" 2'-0" 23'-0" 5'-6 3/8" 18'-5 5/8" 4" EX. E.1 EX. F C C B 3 3 EX. 1 EX. 1 2 2 1 A 4 7 '- 9 5 /8 " 5 7 /8 " 2 2 '- 9 1 /4 " 2 '- 6 " 1 9 '- 1 1 /2 " CF-1 C F -1 CF-2 CF-2 CF-1 C F -2 C F -2 CF-2 C F -1 C F -1 CF-1 C F -2 HDU4-SDS2.5 HDU4-SDS2.5 21 S3.1 20 S3.1 21 S3.1 21 S3.1 21 S3.1 20 S3.1 20 S3.1 20 S3.1 20 S3.1 18 S3.1 18 S3.1 19 S3.1 19 S3.1 1.9 1.9 1 4 '- 0 1 /4 " 3'-11 3/8" HSS5X5X1/4 BP-1 F-1 35'-6" 49'-0" 84'-6" 1 0 0 '- 0 " 4 4 '- 1 0 5 /8 " 2 3 '- 3 1 /8 " 2 '- 6 " F-10 1 3 '- 3 1 1 /1 6 " 16 S3.1 17 S3.1 SIM 7 7 7 6 FINISH FLOOR = 100'-0 6 6 6 '- 9 " 2 '- 3 " 3 " 4 '- 6 " 7 '- 0 " 9'-0" 3" 2 1 /2 " 1 3 '- 9 1 /2 " B.8 8'-10 1/4" CF-10 3'-6" 1 1/2" 22 S3.1 22 S3.1 7 8 7 SW S W SW S W S W SW S W S W SW 10 1 1 1 1 1 1 1 1 1 1 EX. 5 EX. 5 EX. 4 EX. 4 EX. 3 EX. 3 EX. 2 EX. 2 EX. A EX. B EX. C EX. D EX. EEX. B.9 EX. D.2 2 5 '- 1 0 3 /8 " 2 6 '- 4 " 2 7 '- 9 1 /4 " 2 0 '- 0 3 /8 " 2 5 '- 9 1 /8 " 1 9 '- 1 1 /2 " 97'-3 7/8" 5'-10 1/8" 18'-5 5/8" 2'-0" 23'-0" 5'-6 3/8" 18'-5 5/8" 24'-0 1/8" FV 18'-0" FV 12'-6 3/8" EX. E.1 EX. F C C B 3 3 EX. 1 EX. 1 2 2 1 A 35'-6" 49'-0" 4" 4 7 '- 9 5 /8 " 5 7 /8 " 2 2 '- 9 1 /4 " 2 '- 6 " 1 9 '- 1 1 /2 " 11 7/8" TJI 560 11 7/8" TJI 360 @ 16" OC 11 7/8" TJI 360 @ 16" OC 11 7/8" TJI 210 11 7/8" TJI 110 @ 16" OC 11 7/8" TJI 110 @ 16" OC 1 1 7 /8 " T J I 1 1 0 @ 1 6 " O C 3- 1 3/4"x9 1/2" LVL 2 5 S3.1 5 S3.1 5 S3.1 4 S3.1 4 S3.1 3 S3.1 3 S3.1 3 S3.1 3 S3.1 3 S3.1 2 1.9 1.9 11 S3.1 8 S3.1 3 S3.1 2- 1 3/4"x11 7/8" LVL 2- 1 3/4"x11 7/8" LVL 1 1 7 /8 " T J I 1 1 0 @ 1 6 " O C 1 1 7 /8 " T J I 1 1 0 @ 1 6 " O C 3 - 1 3 /4 "x 1 4 " L V L 3 3 13 S3.1 14 S3.1 12 S3.1 12 S3.1 15 S3.1 10 S3.1 1 S3.1 2 - 1 3 /4 "x 1 1 1 /4 " L V L 2 - 1 3 /4 "x 1 1 1 /4 " L V L 7 S3.1 2 2 2 2 1 3/4x9 1/4" @ 16" OC D O U B L E J O IS T D O U B L E J O IS T D O U B L E J O IS T D O U B L E J O IS T D O U B L E J O IS T D O U B L E J O IS T D O U B L E J O IS T D O U B L E J O IS T D O U B L E J O IS T D O U B L E J O IS T D O U B L E J O IS T D O U B L E J O IS T D O U B L E J O IS T 2- 1 3/4"x11 7/8" LVL 2 2 3- 2x12 2 2 D O U B L E J O IS T D O U B L E J O IS T D O U B L E J O IS T D O U B L E J O IS T L-3 L -1 L -3 L-3 84'-6" 1 0 0 '- 0 " 4 4 '- 1 0 5 /8 " 2 3 '- 3 1 /8 " 2 '- 6 " L -3 L-2 L -3 3- 2x12 L-3 2- 2x12 1 1 2 S3.1 B.8 1 3 /4 x 1 1 1 /4 " 5 5 6 9" 2'-3" 1'-0" T O P O F P A R A P E T = 1 1 3 '- 6 T O P O F P A R A P E T = 1 1 3 '- 6 TOP OF PARAPET = 113'-6 TOP OF PARAPET = 113'-6 T O P O F P A R A P E T = 1 1 3 '- 6 TOP OF SHEATHING = 111'-6 W8x18 W8x10 W8x10 W8x10 7 7 7 7 8'-10 1/4" 3 9 S3.1 6 S3.1 NOTES 1. 2. 3. 4. REFER TO DESIGN DATA, SCHEDULES & TYP DETAILS UNLESS NOTED OTHERWISE ALL DIMENSIONS ARE TO FACE OF WALL FRAMING OR CENTERLINE OF COLUMNS FRAMING KEY BEAR ON COLUMN FRAME INTO COLUMN TOP OF STEEL BOTTOM OF STEEL INDICATES SHEET NOTE REFER TO PLAN FOR LOCATION SISTER 2x12 TO EXISTING JOIST, ATTACH TO EXISTING JOIST w/ 3- .148"x3" NAIL @ 12" OC REMOVE 2- 2x12 JOIST REPLACE w/ 2x12 JOIST AS INDICATED T ### B ### 5 # 6 POCKET BEAM INTO EXISTING WALL. BEAR BEAM MIN 4" ON 3/8x6x8" EMBED PL w/ 2- 1/2"x6" HS, WELD TO EMBED w/ 3/16"x3" FILLET EA SIDE 7 7/2 9/2 022 SHEET NO. DATE PROJECT KEARNEY TERMINAL SEAL NO . RE VI SI ON S DA TE CIVIL ENGINEER DR AW N BY : DE SI GN ED BY : RE VI EW ED BY : QU AN TI TI ES CH EC KE D BY : ARCHITECT CONSULTANT K E A R N E Y R E G IO N A L A IR P O R T T E R M IN A L E X P A N S IO N K E A R N E Y , N E B R A S K A 1 AD DE ND UM 1 08 -2 4- 22 7/29/2022 S2.1 ST RU CT UR AL P LA NS 1/8" = 1'-0" 1 FOUNDATION PLAN 1/8" = 1'-0" 2 ROOF FRAMING TERMINAL EXPANSION KEARNEY REGIONAL AIRPORT (EAR) KEARNEY, NEBRASKA AIP 3-31-0045-036 (CARES) ADDENDUM NO. 1 Attachment No. 5 Revised Plan Sheets (Mechanical) Sheets M1.1, M1.2, M2.0, M2.1, M3.1, M4.1, M5.1 and M5.2 L AD A G AT E L BINS EMPTY BINS EMPTY B IN S EM PT Y L3 PROVISION2 AIT2E N TE R EX IT ETD 224 SS ET D TABLE630 2 TDC/CATTDC/CAT AVS W TM D C EI A TABLE630 2 2 2 ST SO 3'-9"3' 35. 0000 24. 0000 35. 0000 24. 0000 0. 0000 0. 0000 AT 2 60 40 a Ti X B IN S EM PT Y B IN S EM PT Y T T T T M T T T T T T T T T T T T GENERAL MECHANICAL NOTES 1. DO NOT ROUTE DUCTWORK OR PIPING ABOVE ELECTRICAL PANELS. MAINTAIN ALL CODE REQUIRED CLEARANCES. 2. FIRE CAULK ALL DUCTWORK PENETRATIONS THROUGH FIRE RATED WALLS AND ASSEMBLIES. CAULK AROUND ALL DUCTWORK PENETRATIONS THROUGH FULL HEIGHT SOUND WALLS. REFER TO ARCHITECTURAL DRAWINGS FOR WALL CONSTRUCTION. 3. SPACE ABOVE CEILINGS IS LIMITED. COORDINATE DUCT AND PIPE ROUTING WITH ALL OTHER TRADES. OFFSET AND EXTEND DUCTWORK AND PIPING AS REQUIRED TO AVOID CONFLICTS. 4. CENTER DIFFUSERS, REGISTERS, AND GRILLES IN CEILING TILES WHERE 24x24 OR 24x12 CEILING DEVICES ARE NOT USED. 5. ROUND RUN-OUTS TO DIFFUSERS SHALL BE THE SAME SIZE AS THE NECK UNLESS OTHERWISE NOTED. SEE DIFFUSER CONNECTION DETAIL 2 ON SHEET M4.1. 6. CONTRACTOR TO PROVIDE ALL LOW VOLTAGE AND LINE VOLTAGE CONTROL WIRING REQUIRED FOR COMPLETE OPERATION OF ALL MECHANICAL EQUIPMENT. 7. PROVIDE VOLUME DAMPER IN EACH SUPPLY AIR BRANCH OFF OF MAIN DUCTWORK AS INDICATED ON PLAN. AC-108 ACCU-108 TSA DATA 124 PRIVATE SCREENING ROOM 129 TSA BAG SCREENING 118 OUTBOUND BAGGAGE 119 TSA OFFICE 127 TSA OFFICE 128 TSA BREAK ROOM 125 TSA WORK AREA 123 BOARDING 132 SECURE HOLDROOM 130 OFFICE 108 VESTIBULE 101 TSA CHECKPOINT 121 MECHANICAL 122 TSA PASSENGER QUEUING 120 MECHANICAL M150 SECURE HOLDROOM WEST 137 ARRIVALS VESTIBULE 103 INBOUND BAGGAGE 104 BAGGAGE CLAIM 105 RENTAL DESK 106 R E N T A L O F F IC E 1 0 7 OFFICE 109 NON-SECURE WAITING 111 AIRLINE OFFICE 113 ALCOVE 133 RESTROOM 134 RESTROOM 135 RESTROOM 115 RESTROOM 114 CUST. 117 HALLWAY 112 LOBBY CONCOURSE 102 TICKETING 110 TSA ENTRY 126 AIRPORT STORAGE 105A FAMILY RESTROOM 116 FAMILY RESTROOM 136 ACCU-124 AC-124 10"ø D-1 310 10"ø D-1 310 10"ø D-1 310 10"ø D-1 310 10"ø D-1 310 10"ø D-1 300 10"ø D-1 300 8"ø D-1 250 8"ø D-1 250 8"ø D-1 250 22"x22" G-1 22 "x 10 " G -2 22"x10" G-2 10"ø D-1 320 10"ø D-1 320 10"ø D-1 320 10"ø D-1 320 10"ø D-1 320 22"x22" G-1 CU (E) CU (E) 12/12 16/12 20 /1 4 22"x22" G-1 (TYP 2) 10"ø D-1 300 22"x10" G-2 12/12 20 /1 2 22"x10" G-2 14/10 22"x10" G-2 22"x10" G-2 10/8 EWH-126 20/12 12/6 16/10 24 /1 0 12/10 12/6 12/6 12/6 12/6 24/10 6"Ø EWH-129 20/14 SECURE HOLDROOM EAST 131 EWH-103 EUH-122 8'-0" AFF 24"x8" LBG-1 600 10"ø D-1 400 10"ø D-1 400 G (E ) 40 0 G (E ) 40 0 8'-0" AFF 24"x8" LBG-1 600 AC-118 14/12 14/12 10/12 10/12 22 "x 22 " G -1 22 "x 22 " G -1 8"ø D-1 210 8"ø D-1 210 10"ø D-1 350 6"ø D-1 100 10"ø D-1 365 10"ø D-1 365 8"ø D-1 280 8"ø D-1 280 6" ø D -1 13 0 G (E ) 60 0 G (E ) G (E ) 50 0 G (E ) 50 0 8" ø D -1 20 0 12 "ø D -1 40 0 8"ø D-1 200 22/8 (E) 16/8 (E) 14/8 (E) 26/8 (E) 46 /1 2 (E ) 42 /1 0 (E ) 38 /1 0 (E ) 18 /1 0 (E ) 18/10 (E) 22 /1 2 (E ) 22 /1 2 (E ) 14 /8 ( E ) 14/12 (E) 14/12 (E) 16 /1 0 (E ) 16 /1 4 (E ) 8"ø D-1 150 EBH-2 (E) 8"ø D-1 250 10/8 AHU (E) AHU (E) G F D F (E ) GFDF (E) 16 "Ø ( E ) 16 "Ø ( E ) 16 "Ø ( E ) 14"Ø (E) 12"Ø (E) 14"Ø (E) 24"Ø (E) 18"Ø (E) 14"Ø (E) EF-116 EF-136 8"Ø 8"x8" G-3 200 EF-125 8/8 8/8 8"ø D-2 160 8"ø D-2 160 10"x10" G-3 250 6"ø D-2 50 8" x8 " G -3 75 8"x8" G-3 75 6"ø D-2 50 10"x10" G-3 250 G(E) 600 GFUH-119 GFUH-104 GFUH-M150 G(E) 100 6" ø D -1 10 0 10/8 10/8 10/8 18"x12" IL-1 360 8/8 8/ 8 12/10 14/12 (E) 14 /1 4 (E ) G(E) G(E) G (E ) G(E) G(E) G(E) G (E ) G(E) G(E) G(E) G(E) G(E) G (E ) (TYP.)M102 (TYP.)M102 (TYP.)M102 (TYP.)M103 8x8 EA UP 8"Ø EA UP (T Y P .) M 10 3 M104 M 10 5 M106 M106 M106 M106 M106 M106 M106 M107 LBG-2 (TYP.) 3 M4.1 (TYP.) 4 M4.1 6 M4.1 (TYP.) 11 M4.1 12 M4.1 8/8 8/8 18"x6" G-2 (TYP 2) EX. 5 EX. 4 EX. 3 EX. 2 EX. A EX. C EX. D EX. EEX. B.9 EX. D.2 EX. F 1 2 3 EX. 1 EX. B A B C M102 M 10 2 M111 M111 M113 M114 M115 M115 M115 M115 M116 M117 M 12 0 EH-101A EH-101B M121 M121 M122 1 m o e y rr Is s e n g I n e e r I n g I n c m e c h a n ic a l | e le c tr ic a l | te c h n o lo g y | c o m m is s io n in g 4 9 4 0 N o rt h 1 1 8 th S tr e e t O m a h a , N E 6 8 1 6 4 P : 4 0 2 .4 9 1 .4 1 4 4 w w w .m o rr is s e y e n g in e e ri n g .c o m M E I P R O J E C T # : E N G I N E E R S O ET A T S P R O F E RBENF A KSA E O N S I AL M CH IAN CAL ∆ ∆ JASON R. E-12778 EICKMEIER SHEET NO. DATE PROJECT KEARNEY TERMINAL SEAL NO . RE VI SI ON S DA TE CIVIL ENGINEER DR AW N BY : DE SI GN ED BY : RE VI EW ED BY : QU AN TI TI ES CH EC KE D BY : ARCHITECT CONSULTANT K E A R N E Y R E G IO N A L A IR P O R T T E R M IN A L E X P A N S IO N K E A R N E Y , N E B R A S K A 2 0 3 7 1 07/29/2022 7/29/2022 M1.1 HV AC P LA N KEYNOTES M102 EXTEND EXISTING DUCTWORK AS NECESSARY TO NEW DIFFUSER. M103 PROVIDE NEW TO EXISTING CONNECTION. M104 CONNECT NEW OUTDOOR AIR DUCT TO EXISTING RETURN AIR PLENUM. BALANCE DAMPER TO PROVIDE 200 CFM OF OUTDOOR AIR TO EXISTING AHU. M105 CONNECT NEW OUTDOOR AIR DUCT TO EXISTING RETURN AIR PLENUM. BALANCE DAMPER TO PROVIDE 160 CFM OF OUTDOOR AIR TO EXISTING AHU. M106 PROVIDE 7 DAY PROGRAMMABLE THERMOSTAT WITH REMOTE CONNECTIVITY CAPABILITY. M107 EXISTING GROUND MOUNTED UNIT SERVING THIS AREA WILL BE DEMOLISHED IN PHASE 1. THE NEW RTU SERVING THIS SPACE WILL BE INSTALLED IN PHASE 2. PROVIDE TEMPORARY HEATING AND COOLING AS REQUIRED. M111 CUT EXISTING FLOOR GRILLE TO AVOID BEING UNDER NEW WALL. PROVIDE BLANK OFF PANEL FOR PORTION OF GRILLE THAT IS COVERED BY NEW WALL. M113 NEW FLOOR GRILLE IS INTENDED TO FIT WITHIN EXISTING FLOOR OPENING WITH NO ADDITIONAL CONCRETE WORK. ADJUST SIZE AS NECESSARY TO FIT EXISTING OPENING. M114 PROVIDE LOW LEAKAGE MOTORIZED DAMPER. INTERLOCK MOTORIZED DAMPER WITH SUPPLY FAN OF EXISTING AHU AND BALANCE TO PROVIDE 360 CFM OF OUTDOOR AIR. ALL 120V WIRING BY ELECTRICAL CONTRACTOR. 24V WIRING BY MECHANICAL CONTRACTOR. M115 REBALANCE EXISTING GRILLE TO THE CFM SHOWN. M116 EXISTING AHU TO BE BALANCED TO PROVIDE 1,530 CFM OF SUPPLY AIR. M117 EXISTING AHU TO BE BALANCED TO PROVIDE 4,830 CFM OF SUPPLY AIR. M120 COORDINATE PATCHING OF EXISTING CMU WALL WITH GENERAL CONTRACTOR. M121 MOUNT ELECTRIC INFRARED HEATER FROM WALL WITH MANUFACTURER PROVIDED WALL MOUNT. INSTALL 3" FROM CEILING, MINIMIZE MANUFACTURER REQUIRED CLEARANCE TO CEILING AS MUCH AS POSSIBLE. M122 PROVIDE LINE VOLTAGE THERMOSTAT FOR EH-101A AND EH-101B CONTROL. COORDINATE WITH ELECTRICAL CONTRACTOR. SCALE:N 1/8" = 1'-0"M1.1 1 HVAC PLAN 1 A d de nd um N o. 1 8/ 24 /2 02 2 1 MECHANICAL ROOF PLAN GENERAL NOTES 1. SEAL ALL ROOF PENETRATIONS WATER TIGHT. COORDINATE ALL PENETRATIONS WITH GENERAL CONTRACTOR AND ROOFING CONTRACTOR. 2. COORDINATE ALL DUCT AND PIPE ROUTING IN ATTIC WITH ATTIC WALKWAYS. MAINTAIN ACCESSIBLE PATHS FROM ATTIC HATCHES TO AREA WELL ACCESS DOORS. 3. ALL OUTDOOR AIR INTAKES SHALL BE LOCATED AT LEAST 10 FEET FROM EXHAUST OUTLETS, COMBUSTION AIR STACKS, AND PLUMBING VENTS. 4. MAINTAIN ALL CODE AND MANUFACTURER'S RECOMMENDED CLEARANCES AROUND ALL ROOF EQUIPMENT. 5. WASTE AND VENT RISERS ARE DESIGNATED BY . SEE WASTE AND VENT RISER DIAGRAMS ON SHEETS M3.1 FOR WASTE AND VENT PIPE SIZES. X RTU-123 RTU-121 RTU-131 RTU (E) RTU (E) EF (E) EF (E) EF (E) 4" RD-1 4" OD-1 4" RD-14" OD-1 4" VTR 4" VTR ACCU-118 HD-1 HD-2 G G 3/4" G 1" G 1" G 3/4" G 3/4" G 1" G 1" G 1" G 1" G 3/ 4" G 3/4" G 3/4" G DN (TYP.) 5 M4.1 (TYP.) 14 M4.1 M202 (TYP.)M108 (TYP.)M109 M110 M110 M110 1" G DN 1 2 EX. 5 EX. 4 EX. 3 EX. 2 EX. A EX. C EX. D EX. EEX. B.9 EX. D.2 EX. F 1 2 3 EX. 1 EX. B A B C RH-1 M118 M119 15 M4.1 4" RD-1 4" RD-1 4" RD-1 4" RD-1 4" RD-1 4" RD-1 4" RD-1 M217 M217 M202 1 1 1 1 1 1 1 1 1 1 1 1 m o e y rr Is s e n g I n e e r I n g I n c m e c h a n ic a l | e le c tr ic a l | te c h n o lo g y | c o m m is s io n in g 4 9 4 0 N o rt h 1 1 8 th S tr e e t O m a h a , N E 6 8 1 6 4 P : 4 0 2 .4 9 1 .4 1 4 4 w w w .m o rr is s e y e n g in e e ri n g .c o m M E I P R O J E C T # : E N G I N E E R S O ET A T S P R O F E RBENF A KSA E O N S I AL M CH IAN CAL ∆ ∆ JASON R. E-12778 EICKMEIER SHEET NO. DATE PROJECT KEARNEY TERMINAL SEAL NO . RE VI SI ON S DA TE CIVIL ENGINEER DR AW N BY : DE SI GN ED BY : RE VI EW ED BY : QU AN TI TI ES CH EC KE D BY : ARCHITECT CONSULTANT K E A R N E Y R E G IO N A L A IR P O R T T E R M IN A L E X P A N S IO N K E A R N E Y , N E B R A S K A 2 0 3 7 1 07/29/2022 7/29/2022 M1.2 M EC HA NI CA L R OO F P LA N KEYNOTES M108 ALL MECHANICAL EQUIPMENT SHALL BE A MINIMUM OF 10'-0" FROM THE EDGE OF THE ROOF. M109 ALL EXHAUST OUTLETS AND VTRS SHALL BE A MINIMUM OF 10'-0" FROM ANY OUTDOOR AIR INTAKE. M110 CONCENTRIC VENT KIT FOR GFUH SHALL BE A MINIMUM OF 10'-0" FROM ANY OUTDOOR AIR INTAKE. M118 EXISTING RTU TO BE BALANCED TO PROVIDE 1,200 CFM OF SUPPLY AIR. M119 EXISTING RTU TO BE BALANCED TO PROVIDE 2,000 CFM OF SUPPLY AIR. M202 PROVIDE NEW TO EXISTING CONNECTION. VERIFY SIZE AND LOCATION OF EXISTING PIPE PRIOR TO INSTALLATION. M217 PROVIDE NEW GAS REGULATOR FOR EXISTING EQUIPMENT. SCALE:N 1/8" = 1'-0"M1.2 1 MECHANICAL ROOF PLAN 1 A d de nd um N o. 1 8/ 24 /2 02 2 1 T GENERAL UNDERGROUND PLUMBING NOTES 1. ALL PLUMBING SHOWN LIGHT OR INDICATED WITH (E) IS EXISTING. NOT ALL EXISTING PLUMBING ITEMS ARE SHOWN. ITEMS SHOWN DARK ARE NEW. 2. EXISTING SYSTEMS ARE BASED ON EXISTING CONSTRUCTION DOCUMENTS (FURNISHED BY OTHERS) AND APPROXIMATIONS FROM FIELD OBSERVATIONS. DRAWINGS ARE SCHEMATIC IN NATURE. FIELD VERIFY EXACT LOCATION OF ALL EXISTING PIPING. 3. HOLES AND SAW CUTS IN FLOORS TO PERMIT THE INSTALLATION OF PIPING SHALL BE CAREFULLY MADE AND RESTRICTED TO THE SMALLEST PRACTICAL SIZE. PATCH SLAB AS REQUIRED FOR NEW WORK TO MATCH EXISTING. 4. PIPE ROUTING IS SHOWN FOR CLARITY AND GENERAL ROUTING INFORMATION. CONTRACTOR SHALL COORDINATE EXACT ROUTING WITH ALL TRADES. OFFSET AND TRANSITION PIPING AS REQUIRED TO AVOID CONFLICTS. 5. REFER TO WASTE AND VENT RISER DIAGRAM FOR COMPLETE WASTE AND VENT SIZES ON SHEET M3.1. 6. COORDINATE ALL BELOW GRADE PIPING WITH STRUCTURAL FOOTINGS. PROVIDE SLEEVES AS REQUIRED. CITY OF KEARNEY COMPLIANCE NOTES 1. ALL PLUMBING VENTS SHALL MEET THE MINIMUM SIZE REQUIREMENTS OF THE 2015 UNIFORM PLUMBING CODE. 2. THE DOMESTIC WATER METER FURNISHED BY THE CITY OF KEARNEY UTILITIES DEPARTMENT AND INSTALLED BY THE CONTRACTOR MUST BE LOCATED IN AN AREA THAT WILL ALLOW FOR EASE OF MAINTENANCE. THE METER CANNOT BE INSTALLED ABOVE A CEILING. THE CITY UTILTIES DEPARTMENT WILL FURNISH A WIRE TO RUN FROM THE INDOOR WATER METER TO THE OUTDOOR REMOTE READER. THE WIRE WILL BE INSTALLED BY THE CONTRACTOR. 3. MAINTAIN SEPARATION BETWEEN THE WATER SERVICE AND SANITARY SEWERS AS STATED IN "RECOMMENDED STANDARDS FOR WATER WORKS 8.8.2" 4. BACKFLOW DEVICES SHALL BE INSTALLED AS PER CITY OF KEARNEY CODE CHAPTER 10-405. FINAL DETERMINATION OF BACKFLOW REQUIREMENTS WILL BE MADE BY THE CITY OF KEARNEY'S WATER QUALITY COORDINATOR. 5. TEMPORARY WATER SERVICE, IF REQUIRED BY THE CONTRACTOR FOR CONSTRUCTION, WILL REQUIRE THE DOMESTIC WATER METER TO BE INSTALLED IN IT'S PERMANENT LOCATION, PROTECTED FROM COLD TEMPERATURES, AND AN ACCOUNT WILL NEED TO BE SET UP WITH THE CITY OF KEARNEY'S UTILITIY BILLING DEPARTMENT TO PAY FOR ALL WATER USE. 2" G (E) 2" CW (E) 4" W (E) 4" W (E) 4" W (E) 2" CW (E) F.C.O. 4" W 4" W F.C.O. (E) F.C.O. FIRE SERVICE ENTRANCE 6" F 3" FS-1 F.C.O. 2" W UP 2" V UP 2" W 2" W UP 2" W UP 2" V UP 2" V UP 2" W UP 2" D-1 2" D-1 WC-1 WC-1 6" ST I.E. 2125.17 D.G.C.O 6" S T 6" ST UP 6" ST UP3/4" IRRIGATION F.C.O.4" W D.G.C.O M212 M202 M213 (TYP.) 7 M4.1 (TYP.) 8 M4.1 EX. 5 EX. 4 EX. 3 EX. 2 EX. A EX. C EX. D EX. EEX. B.9 EX. D.2 EX. F 1 2 3 EX. 1 EX. B A B C I.E. 2126.93 SEE CIVIL FOR CONTINUATION SEE CIVIL FOR CONTINUATION 2" W UP 1 m o e y rr Is s e n g I n e e r I n g I n c m e c h a n ic a l | e le c tr ic a l | te c h n o lo g y | c o m m is s io n in g 4 9 4 0 N o rt h 1 1 8 th S tr e e t O m a h a , N E 6 8 1 6 4 P : 4 0 2 .4 9 1 .4 1 4 4 w w w .m o rr is s e y e n g in e e ri n g .c o m M E I P R O J E C T # : E N G I N E E R S O ET A T S P R O F E RBENF A KSA E O N S I AL M CH IAN CAL ∆ ∆ JASON R. E-12778 EICKMEIER SHEET NO. DATE PROJECT KEARNEY TERMINAL SEAL NO . RE VI SI ON S DA TE CIVIL ENGINEER DR AW N BY : DE SI GN ED BY : RE VI EW ED BY : QU AN TI TI ES CH EC KE D BY : ARCHITECT CONSULTANT K E A R N E Y R E G IO N A L A IR P O R T T E R M IN A L E X P A N S IO N K E A R N E Y , N E B R A S K A 2 0 3 7 1 07/29/2022 7/29/2022 M2.0 BE LO W G RA DE P LU M BI NG PL AN KEYNOTES M202 PROVIDE NEW TO EXISTING CONNECTION. VERIFY SIZE AND LOCATION OF EXISTING PIPE PRIOR TO INSTALLATION. M212 NEW BUILDING ADDITION TO BE CONSTRUCTED IN PHASE 1. EXISTING BUILDING RENOVATION TO OCCUR IN PHASE 2. SEE ARCHITECTURAL PLANS FOR PHASING. COORDINATE TIMING OF ALL WORK IN EXISTING BUILDING REQUIRED IN PHASE 1 WITH GENERAL CONTRACTOR. M213 PROVIDE 3/4" IRRIGATION LINE. SEE CIVIL FOR CONTINUATION. PROVIDE REDUCED PRESSURE BACK-FLOW PREVENTER. VERIFY IRRIGATION LINE SIZE AND DEMAND WITH IRRIGATION CONTRACTOR. SCALE:N 1/8" = 1'-0"M2.0 1 BELOW GRADE PLUMBING 1 A d de nd um N o. 1 8/ 24 /2 02 2 L AD A G AT E L BINS EMPTY BINS EMPTY B IN S EM PT Y L3 PROVISION2 AIT2E N TE R EX IT ETD 224 SS ET D TABLE630 2 TDC/CATTDC/CAT AVS W TM D C EI A TABLE630 2 2 2 ST SO 3'-9"3' 35. 0000 24. 0000 35. 0000 24. 0000 0. 0000 0. 0000 AT 2 60 40 a Ti X B IN S EM PT Y B IN S EM PT Y T PIPING/PLUMBING GENERAL NOTES 1. DO NOT ROUTE PIPING ABOVE ELECTRICAL PANELS. MAINTAIN ALL CODE REQUIRED CLEARANCES. 2. SPACE ABOVE CEILINGS IS LIMITED. COORDINATE PIPE ROUTING WITH ALL OTHER TRADES. PROVIDE ALL ADDITIONAL OFFSETS AND TRANSITIONS AS REQUIRED TO COMPLETE INSTALLATION. 3. PLANS ARE SCHEMATIC IN NATURE. COORDINATE EXACT ROUTING AND EQUIPMENT LOCATIONS WITH ALL OTHER TRADES. PROVIDE ALL ADDITIONAL OFFSETS AS REQUIRED TO COMPLETE INSTALLATION. 4. INSTALL ALL ISOLATION VALVES AND BALANCING VALVES IN ACCESSIBLE LOCATIONS. 5. ALL PIPING SHOWN FOR CLARITY. ROUTE WASTE, VENT, WATER, AND GAS PIPING CONCEALED IN CHASES, IN WALLS, OR ABOVE CEILINGS AS REQUIRED. 6. DO NOT ROUTE WATER PIPING IN EXTERIOR WALLS UNLESS OTHERWISE NOTED. PIPING ROUTED IN EXTERIOR WALLS SHALL BE LOCATED ON THE INTERIOR SIDE OF INSULATION. 7. NOT ALL CLEANOUTS ARE SHOWN. PROVIDE CLEANOUTS PER UNIFORM PLUMBING CODE. EXTEND CLEANOUTS TO WALLS WHERE APPLICABLE. COORDINATE CLEANOUT LOCATIONS WITH GENERAL CONTRACTOR. 8. COORDINATE ALL BELOW GRADE PIPING WITH STRUCTURAL FOOTINGS. SLEEVE PIPING AS REQUIRED. SEE STRUCTURAL DRAWINGS. COORDINATE WITH GENERAL CONTRACTOR. 9. WASTE AND VENT RISERS ARE DESIGNATED BY . SEE WASTE AND VENT RISER DIAGRAMS ON SHEET M5.2 FOR WASTE AND VENT PIPE SIZES. 10. SEE PLUMBING FIXTURE SCHEDULE SHEET M7.3 FOR PLUMBING FIXTURE CONNECTION REQUIREMENTS. 11. ALL PENETRATIONS OF FIRE RESISTANT CONSTRUCTION SHALL BE SEALED WITH A LISTED FIRESTOPPING ASSEMBLY BY THE CONTRACTOR RESPONSIBLE FOR THE PENETRATION. X CITY OF KEARNEY COMPLIANCE NOTES 1. ALL PLUMBING VENTS SHALL MEET THE MINIMUM SIZE REQUIREMENTS OF THE 2015 UNIFORM PLUMBING CODE. 2. THE DOMESTIC WATER METER FURNISHED BY THE CITY OF KEARNEY UTILITIES DEPARTMENT AND INSTALLED BY THE CONTRACTOR MUST BE LOCATED IN AN AREA THAT WILL ALLOW FOR EASE OF MAINTENANCE. THE METER CANNOT BE INSTALLED ABOVE A CEILING. THE CITY UTILTIES DEPARTMENT WILL FURNISH A WIRE TO RUN FROM THE INDOOR WATER METER TO THE OUTDOOR REMOTE READER. THE WIRE WILL BE INSTALLED BY THE CONTRACTOR. 3. MAINTAIN SEPARATION BETWEEN THE WATER SERVICE AND SANITARY SEWERS AS STATED IN "RECOMMENDED STANDARDS FOR WATER WORKS 8.8.2" 4. BACKFLOW DEVICES SHALL BE INSTALLED AS PER CITY OF KEARNEY CODE CHAPTER 10-405. FINAL DETERMINATION OF BACKFLOW REQUIREMENTS WILL BE MADE BY THE CITY OF KEARNEY'S WATER QUALITY COORDINATOR. 5. TEMPORARY WATER SERVICE, IF REQUIRED BY THE CONTRACTOR FOR CONSTRUCTION, WILL REQUIRE THE DOMESTIC WATER METER TO BE INSTALLED IN IT'S PERMANENT LOCATION, PROTECTED FROM COLD TEMPERATURES, AND AN ACCOUNT WILL NEED TO BE SET UP WITH THE CITY OF KEARNEY'S UTILITIY BILLING DEPARTMENT TO PAY FOR ALL WATER USE. WH (E) DN (E) 4" ST (E) 4" S T ( E ) 4" ST (E) DN (E) EWH (E) WC-1 2" D-1 L-1 L-1 2" D-1 WC-1 F.C.O. FD (E) FD (E) FD (E) FD (E) S-1 AC-124 F.C.O. (E) IEWH-1 3/4" CW (E) 3/4" CW (E) 2" CW (E) 3/4" HW (E) WH-1 WH-1 3/4" CW 3/ 4" C W F.C.O. FIRE SERVICE ENTRANCE WS-1 3" FS-1 2" V UP TO VTR 4" DN-1 4" DN-1 4" OF 4" OF 2" C W 2" C W 2" CW 2" SCW 2" S C W 3/4" SCW EWC-1 2" SCW 1/2" HW 2" S C W 1/ 2" H W 2" V UP TO VTR DN (R) TSA DATA 124 PRIVATE SCREENING ROOM 129 TSA BAG SCREENING 118 OUTBOUND BAGGAGE 119 TSA OFFICE 127 TSA OFFICE 128 TSA BREAK ROOM 125 TSA WORK AREA 123 BOARDING 132 SECURE HOLDROOM 130 OFFICE 108 VESTIBULE 101 TSA CHECKPOINT 121 MECHANICAL 122 TSA PASSENGER QUEUING 120 MECHANICAL M150 SECURE HOLDROOM WEST 137 ARRIVALS VESTIBULE 103 INBOUND BAGGAGE 104 BAGGAGE CLAIM 105 RENTAL DESK 106 RENTAL OFFICE 107 OFFICE 109 NON-SECURE WAITING 111 AIRLINE OFFICE 113 ALCOVE 133 RESTROOM 134 RESTROOM 135 RESTROOM 115 RESTROOM 114 CUST. 117 HALLWAY 112 LOBBY CONCOURSE 102 TICKETING 110 TSA ENTRY 126 AIRPORT STORAGE 105A FAMILY RESTROOM 116 FAMILY RESTROOM 136 SECURE HOLDROOM EAST 131 1 1/2" V2" V 4" ST R E F 6" ST DN 4" S T AC-118 FDC 4" S T C.O. 6" ST 1/ 2" W 1 1/4" CW OB-1 3/4" CD AC-108 3/ 4" C D ACCU-108 R E F REF R E F ACCU-124 F.C.O. WH-1 GFUH-119 GFUH-M150 GFUH-104 GAS METER (E) 1" G 3/ 4" G 3/ 4" G 3/4" G 1 1/ 2" G 1 1/2" G 1" G UP 3/4" G (T Y P .) M 20 1 M202 M202 M202 M203 M203 (TYP.)M204 (TYP.) M204 M206 M207 M208 M209 M209 M210 4" OF UP 4" ST UP 4" ST UP 4" OF UP M211 (TYP.)M212 (TYP.) M212 9 M4.1 13 M4.1 EX. 5 EX. 4 EX. 3 EX. 2 EX. A EX. C EX. D EX. EEX. B.9 EX. D.2 EX. F 1 2 3 EX. 1 EX. B A B C M 21 4 3/4" CD M205 M213 UP TO RH-1 3/4" CW 3/4" G UP 3/4" G UP M 21 5 M215 M215 M215 M215 M216 M 21 7 M217 UR-1 1 1 M218 16 M4.1 1 m o e y rr Is s e n g I n e e r I n g I n c m e c h a n ic a l | e le c tr ic a l | te c h n o lo g y | c o m m is s io n in g 4 9 4 0 N o rt h 1 1 8 th S tr e e t O m a h a , N E 6 8 1 6 4 P : 4 0 2 .4 9 1 .4 1 4 4 w w w .m o rr is s e y e n g in e e ri n g .c o m M E I P R O J E C T # : E N G I N E E R S O ET A T S P R O F E RBENF A KSA E O N S I AL M CH IAN CAL ∆ ∆ JASON R. E-12778 EICKMEIER SHEET NO. DATE PROJECT KEARNEY TERMINAL SEAL NO . RE VI SI ON S DA TE CIVIL ENGINEER DR AW N BY : DE SI GN ED BY : RE VI EW ED BY : QU AN TI TI ES CH EC KE D BY : ARCHITECT CONSULTANT K E A R N E Y R E G IO N A L A IR P O R T T E R M IN A L E X P A N S IO N K E A R N E Y , N E B R A S K A 2 0 3 7 1 07/29/2022 7/29/2022 M2.1 PL UM BI NG & M EC HA NI CA L PI PI NG P LA N KEYNOTES M201 DO NOT ROUTE DUCTWORK OR PIPING ABOVE ELECTRICAL PANELS. MAINTAIN ALL NEC REQUIRED CLEARANCES. M202 PROVIDE NEW TO EXISTING CONNECTION. VERIFY SIZE AND LOCATION OF EXISTING PIPE PRIOR TO INSTALLATION. M203 ROUTE REFRIGERANT PIPING FROM WALL MOUNTED MINI-SPLIT TO CONDENSING UNIT. M204 LOCATE STORM OVERFLOW DRAIN DOWNSPOUT NOZZLE AT 18" ABOVE ADJACENT GRADE. M205 ROUTE CONDENSATE FROM AC-124 TO FLOOR SINK. TERMINATE WITH AIR GAP AS REQUIRED. M206 RELOCATE EXISTING DOWNSPOUT TO NEW EXTERIOR. CONNECT TO EXISTING LEADER. FIELD VERIFY EXISTING CONDITIONS. M207 PROVIDE STOP VALVE WITH WATER CONNECTION FOR OWNER PROVIDED INSTANT HOT WATER DISPENSER. M208 ROUTE CONDENSATE TO MECHANICAL M150. CONNECT TO EXISTING CONDENSATE PIPING FROM EXISTING AHU. M209 ROUTE STORM PIPING IN JOIST SPACE ABOVE DUCT. M210 ROUTE DRAIN LINE FROM ROOF HYDRANT TO FLOOR SINK. M211 CONNECT 2" SCW TO EXISTING 2" CW. M212 NEW BUILDING ADDITION TO BE CONSTRUCTED IN PHASE 1. EXISTING BUILDING RENOVATION TO OCCUR IN PHASE 2. SEE ARCHITECTURAL PLANS FOR PHASING. COORDINATE TIMING OF ALL WORK IN EXISTING BUILDING REQUIRED IN PHASE 1 WITH GENERAL CONTRACTOR. M213 PROVIDE 3/4" IRRIGATION LINE. SEE CIVIL FOR CONTINUATION. PROVIDE REDUCED PRESSURE BACK-FLOW PREVENTER. VERIFY IRRIGATION LINE SIZE AND DEMAND WITH IRRIGATION CONTRACTOR. M214 PROVIDE 2" SCW TO EXISTING WATER HEATER. M215 CONNECT EXISTING STORM PIPING TO NEW ROOF DRAIN. M216 EXISTING GAS METER TO REMAIN. NORTHWESTERN ENERGY TO REPLACE REGULATOR TO DELIVER 2 PSI GAS TO THE BUILDING. EXISTING REGULATOR IS PROVIDING 7" WC TO THE BUILDING. COORDINATE REPLACEMENT WITH NORTHWESTERN ENERGY. M217 PROVIDE NEW GAS REGULATOR FOR EXISTING EQUIPMENT. M218 PROVIDE 1/4" TUBE FROM CONDENSATE PUMP TO GRAVITY CONDENSATE MAIN. INSTALL PER MANUFACTURER'S REQUIREMENTS. SCALE:N 1/8" = 1'-0"M2.1 1 PLUMBING & MECHANICAL PIPING PLAN 1 A d de nd um N o. 1 8/ 24 /2 02 2 1 1 PLUMBING NOTES 1. INSTALL ALL PLUMBING PIPING PER UNIFORM PLUMBING CODE. 2. NOT ALL CLEANOUTS ARE SHOWN. PROVIDE CLEANOUTS PER LOCAL CODE REQUIREMENTS. 3. SEE PLUMBING FIXTURE SCHEDULE ON SHEET M5.2 FOR FIXTURE VENT AND WASTE CONNECTION SIZE. CITY OF KEARNEY COMPLIANCE NOTES 1. ALL PLUMBING VENTS SHALL MEET THE MINIMUM SIZE REQUIREMENTS OF THE 2015 UNIFORM PLUMBING CODE. 2. THE DOMESTIC WATER METER FURNISHED BY THE CITY OF KEARNEY UTILITIES DEPARTMENT AND INSTALLED BY THE CONTRACTOR MUST BE LOCATED IN AN AREA THAT WILL ALLOW FOR EASE OF MAINTENANCE. THE METER CANNOT BE INSTALLED ABOVE A CEILING. THE CITY UTILTIES DEPARTMENT WILL FURNISH A WIRE TO RUN FROM THE INDOOR WATER METER TO THE OUTDOOR REMOTE READER. THE WIRE WILL BE INSTALLED BY THE CONTRACTOR. 3. MAINTAIN SEPARATION BETWEEN THE WATER SERVICE AND SANITARY SEWERS AS STATED IN "RECOMMENDED STANDARDS FOR WATER WORKS 8.8.2" 4. BACKFLOW DEVICES SHALL BE INSTALLED AS PER CITY OF KEARNEY CODE CHAPTER 10-405. FINAL DETERMINATION OF BACKFLOW REQUIREMENTS WILL BE MADE BY THE CITY OF KEARNEY'S WATER QUALITY COORDINATOR. 5. TEMPORARY WATER SERVICE, IF REQUIRED BY THE CONTRACTOR FOR CONSTRUCTION, WILL REQUIRE THE DOMESTIC WATER METER TO BE INSTALLED IN IT'S PERMANENT LOCATION, PROTECTED FROM COLD TEMPERATURES, AND AN ACCOUNT WILL NEED TO BE SET UP WITH THE CITY OF KEARNEY'S UTILITIY BILLING DEPARTMENT TO PAY FOR ALL WATER USE. 4" W (E ) 4" W (E) S-1 WC-1 L-1 2" D-1 F.C.O. F.C.O. WC-1 L-1 2" D-1 4" W 4" W 4" VTR 4" W 3" W F .C .O . 3" FS-1 2" V 2" V 4" VTR EWC-1 1 1/2" V2" V 2" W F.C.O. FD (E) FD (E) F.C.O. (E) FD (E) FD (E) 1 2 UR-1 m o e y rr Is s e n g I n e e r I n g I n c m e c h a n ic a l | e le c tr ic a l | te c h n o lo g y | c o m m is s io n in g 4 9 4 0 N o rt h 1 1 8 th S tr e e t O m a h a , N E 6 8 1 6 4 P : 4 0 2 .4 9 1 .4 1 4 4 w w w .m o rr is s e y e n g in e e ri n g .c o m M E I P R O J E C T # : E N G I N E E R S O ET A T S P R O F E RBENF A KSA E O N S I AL M CH IAN CAL ∆ ∆ JASON R. E-12778 EICKMEIER SHEET NO. DATE PROJECT KEARNEY TERMINAL SEAL NO . RE VI SI ON S DA TE CIVIL ENGINEER DR AW N BY : DE SI GN ED BY : RE VI EW ED BY : QU AN TI TI ES CH EC KE D BY : ARCHITECT CONSULTANT K E A R N E Y R E G IO N A L A IR P O R T T E R M IN A L E X P A N S IO N K E A R N E Y , N E B R A S K A 2 0 3 7 1 07/29/2022 7/29/2022 M3.1 PL UM BI NG R ISE R DI AG RA M S SCALE:M3.1 1 WASTE AND VENT RISER DIAGRAM 1 A d de nd um N o. 1 8/ 24 /2 02 2 1 SEE FLOOR PLANS FOR DUCTWORK CONTINUATION AND SIZE PLENUM WITH BITMASTIC LOUVER BIRD SCREEN COAT SHEET METAL 2" RIGID INSULATION BOARD SLOPE PLENUM LABEL CLEANOUT PLUG AS EITHER 'STORM' OR 'SANITARY' CLEANOUT COVER 4" CONCRETE SLAB FROM BUILDING EXTERIOR WALL CLEANOUT PLUG GRADE TO SEWER CLEANOUT COVER SEE PLANS FOR MAIN SIZE TO SEWER CLEANOUT PLUG LABEL CLEANOUT PLUG AS EITHER 'STORM' OR 'SANITARY' FLOOR FROM BUILDING PROVIDE CARPET MARKER WHERE NECESSARY OR RECESSED COVER FOR TILE INLAY (SEE ARCHITECTURAL FOR FLOORING MATERIAL) TERMINAL BOX TAKE-OFF - 2 30° MAX. OVERSIZED BRANCH TAKE-OFF TAKE OFF TO TERMINAL BOX D = WIDTH OF DUCT 1/2 D 45° TAKEOFF TERMINAL BOX TAKE-OFF -1 30° MAX. 1-1/2" R BELLMOUTH FITTING TAKE OFF TO TERMINAL BOX W x D R"Ø DUCT MAIN DEPTH (D) SHALL BE 4" LARGER THAN RUNOUT (R) TO ALLOW BELLMOUTH FITTING. WHERE DUCT SIZES DO NOT ALLOW BELLMOUTH, USE TERMINAL BOX TAKE-OFF - 2 W x D R"Ø PROVIDE CONICAL REDUCER SIZED FROM DUCT MAIN DEPTH (D) TO TAKEOFF SIZE (R) D CONICAL TAKEOFF (USE ONLY WHEN BELLMOUTH FITTING CANNOT BE USED) 45° ROUND TAKE-OFF 45° ENTRY BRANCH CONVERGING TEE (ROUND) 30° MAX. DOUBLE BRANCH TAKE-OFFSINGLE BRANCH TAKE-OFF 30° MAX. 30° MAX. 45° ENTRY BRANCH CONVERGING TEE 90° ELBOW"Y" BRANCH FITTING R = 1/2 D R = 1 X D (UNLESS SHOWN OTHERWISE) R D = WIDTH OF DUCT D NOTE: WHERE FITTING NOT POSSIBLE, USE EXTRACTOR ROUND DUCT TO DIFFUSER SEE PLAN FOR SIZE DIFFUSER TAKE-OFF H.E.T. (HI-EFFICIENCY TAKEOFF) WITH VOLUME DAMPER VOLUME DAMPER DUCTWORK MAIN FLEXIBLE DUCT ROUND DUCT CEILING FLEXIBLE DUCT 36" MAXIMUM LENGTH 45° MAXIMUM BEND SHEET METAL 90° ELBOW ROUND DUCT FLEXIBLE DUCT LINEAR DIFFUSER BOOT 36" MAXIMUM LENGTH 45° MAXIMUM BEND CEILING DIFFUSER LINEAR DIFFUSER TO DIFFUSER 1" WIDE FLANGE WITH GASKET 45 DEGREE TAKEOFF (TYPICAL ALL TAKEOFFS) DAMPER WITH LOCKABLE HANDLE AND INSULATION STANDOFF CEILING DUCT MAIN NOTES: 1) USE OF FLEX DUCT FOR 90 DEGREE TURNS INTO DIFFUSERS WILL NOT BE ACCEPTABLE. 2) ALL DIFFUSER RUNOUTS SHALL UTILIZE 45 DEGREE TAKEOFFS AS INDICATED. STRAIGHT TAPS WILL NOT BE ACCEPTABLE. RECTANGULAR DUCT CEILING FLEXIBLE DUCT 36" MAXIMUM LENGTH 45° MAXIMUM BEND DIFFUSER DUCT TO BE SAME SIZE AS DIFFUSER NECK CEILING DIFFUSER SHEET METAL 90° ELBOW 36" MAXIMUM LENGTH 45o MAXIMUM BEND ROUND DUCT DUCT TO BE SAME SIZE AS DIFFUSER NECK LIQUID LINE MOISTURE INDICATOR SIGHT GLASS FILTER DRYER INDOOR UNIT POWER PUMPED CONDENSATE TO FLOOR DRAIN (SEE FLOOR PLANS) WEATHERPROOF FUSED DISCONNECT (SEE ELECTRICAL) SUCTION LINE SIZE REFRIGERANT PIPING PER MANUFACTURER'S RECOMMENDATIONS POWER WIRING CONDENSING UNIT LOCATED ON GRADE WALL MOUNTED AIR CONDITIONING UNIT CEILING APPROX. 4" ACCU-X AC-X MAINTAIN MANUFACTURER'S RECOMMENDED CLEARANCE AROUND ALL SIDES OF UNIT CONTROL WIRING NOTES: 1. WIRING AND PIPING SHOWN ARE GENERAL POINTS-OF-CONNECTION GUIDES ONLY AND ARE NOT INTENDED FOR A SPECIFIC INSTALLATION. REFER TO FLOOR PLANS FOR EQUIPMENT ORIENTATION. ALSO REFER TO MANUFACTURER'S INSTALLATION MANUALS FOR SPECIFIC INSTALLATION REQUIREMENTS. 2. CONDENSATE PIPING ROUTED IN CEILING PLENUMS SHALL BE COPPER AND SHALL BE INSULATED. SEE SPECIFICATIONS. 3. INSULATE SUCTION LINES. G G G FLEXIBLE CONNECTION (TYP.) DIRT LEG CONDENSATE DRAIN DISCHARGE CONDENSATE TO ROOF GAS COCK LBS TO OZS GAS PRESSURE REGULATOR UNION (TYP.) ROOFTOP UNIT MINIMUM 2" DISTANCE RELIEF AIR HOOD. HEAT EXCHANGER FLUE NOTE : MAINTAIN ALL MANUFACTURER'S RECOMMENDED CLEARANCES FOR AIRFLOW AND SERVICE. SET UNIT ON ROOF CURB PER MANUFACTURER'S INSTRUCTIONS. VERIFY EXACT LOCATION OF UNIT WITH GENERAL CONTRACTOR, STRUCTURE, AND ACTUAL UNIT PROVIDED. MAINTAIN ALL MANUFACTURER'S RECOMMENDED CLEARANCES FOR SERVICES. CUT AND PATCH ROOF AS REQUIRED. COORDINATE ALL ROOF WORK WITH GENERAL CONTRACTOR. SEAL ALL PENETRATIONS WEATHER TIGHT. SUPPORT GAS PIPE WITH PIPE SUPPORTS. SUPPORTS SHALL BE COMPATIBLE WITH ROOFING SYSTEM. NOTE: DISCHARGE CONDENSATE AT ROOF LEVEL. ROUTE CONDENSATE PIPING AWAY FROM RTU TO LOCATION SO CONDENSATE DIVERTED AWAY FROM RTU AND DRAINS WITH THE ROOF SLODE. ROUTE DUCT AS HIGH AS POSSIBLE. SEE PLANS FOR DUCTWORK DISTRIBUTION. SEE SPECIFICATIONS FOR INSULATION REQUIREMENTS (TYP). TRANSITION DUCTWORK TO ROOFTOP UNIT INLET. TRANSITION IN CURB. TRANSITION AROUND STRUCTURE AS REQUIRED (TYP). CURB FLASHING. COORDINATE WITH GENERAL CONTRACTOR. VIBRATION ISOLATION CURB RAIL ROOF CURB. INSTALL CURB LEVEL. SECURE TO ROOF STRUCTURE. SECURE DUCT TO OPENING IN ROOF CURB (TYP.) OUTSIDE AIR HOOD. MAINTAIN 10'-0" MINIMUM CLEARANCE TO BUILDING VENTS. 10 M4.1 SUPPORT DUCT FROM STRUCTURE GRILLE - SEE PLANS GRILLE - SEE PLANS SEE PLANS FOR SIZE LINE PLENUM BOX AND DUCTWORK WITH ACOUSTICAL DUCT LINER SEE SPECIFICATIONS FOR DUCT LINER THICKNESS SEAL DUCT PENETRATION THROUGH WALL ROOFTOP UNIT FULL SIZE THREADED DRAIN CONNECTION (3/4" MINIMUM) THREADED PLUG DRILL 1/4" HOLE THROUGH PLUG RO OF CU RB THREADED DRAIN PLUG FULL SIZE CONDENSATE DRAIN (3/4" MIN.) 4" (MIN) 2" +STATIC PRESSURE OF FAN OR 4" WHICHEVER IS GREATER DISCHARGE CONDENSATE AT ROOF LEVEL. ROUTE CONDENSATE PIPING AWAY FROM RTU TO LOCATION SO CONDENSATE IS DIVERTED AWAY FROM RTU AND DRAINS WITH THE ROOF SLOPE NOTES: 1) PROVIDE DRAIN AT EACH AC UNIT DRAIN OUTLET. 2) PROVIDE THREADED PLUGS WITH HEX HEAD EXTENSION SUITABLE FOR CRESENT WRENCH REMOVAL AND REINSTALLTION. SINK 1/2" HW FAUCET 1/2" CW 1/2" HW IWH-X INSTANTANEOUS WATER HEATER INSTALL IN PER LOCAL CODES 1/2" CW 3/4" CW FROM SPACE ABOVE CEILING DOWN CONCEALED IN WALL TO SPACE BELOW SINK ISOLATION VALVE (TYP.) PROVIDE ESCUTCHEON PLATE AT WALL 3/4" CW ADJUSTABLE LOUVER G DIRT LEG GAS COCK SEE PLANS FOR SIZE UNION UNIT HEATER PROVIDE SINGLE WALL VENT PIPE APPROVED FOR CATEGORY III APPLIANCE UP TO CONCENTRIC ADAPTOR AS REQUIRED BY MANUFACTURER INSTALL PER MANUFACTURER'S RECOMMENDATIONS PROVIDE ROOF FLASHING AS REQUIRED STORM COLLAR ROOF VERTICAL CONCENTRIC ROOF TERMINATION COMBUSTION AIR PROVIDE VENT PIPE TYPE BEYOND CONENTRIC ADAPTOR REQUIRED BY MANUFACTURER LBS TO OZS GAS PRESSURE REGULATOR BRINE TANK MANUAL INLET VALVEMANUAL OUTLET VALVE HARD WATERSOFT WATER WATER SOFTENER CONTROLS S O F T E N E R T A N K FLOW METER FLOOR DRAIN FLOOR MANUAL BYPASS VALVE (NORMALLY CLOSED) INSTALL WATER SOFTENER PER MANUFACTURER'S RECOMMENDATIONS AND LOCAL PLUMBING CODE REQUIREMENTS 2" HARD CW2" SOFT CW HOUSEKEEPING PAD M BUILDING STRUCTURE TRANSITION TO FAN INLET/DISCHARGE SIZE FLEXIBLE DUCT CONNECTION M SUPPORT UNIT FROM STRUCTURE WITH VIBRATION ISOLATION HANGERS. SEE FLOOR PLANS FOR DUCTWORK CONTINUATION AND SIZE DISCONNECT SWITCH MOTORIZED DAMPER EXHAUST FAN AIRFLOW PREFABRICATED ROOF CURB A.B.S. COVER STAINLESS STEEL DRAWBANDS ROOF FLASHING ROOF CONSTRUCTION (VERIFY)GAS LINE THRU ROOF GAS LINE THRU ROOF GAS LINE THRU ROOF SECURE TO ROOF CURB COORDINATE ROOFCURB WITH ROOF CONSTRUCTION NOTE: ROOF CURB BY MECHANICAL CONTRACTOR. COORDINATE ROOF PENETRATIONS AND SEALING WITH WITH ROOFING AND GENERAL CONTRACTOR. SEAL PENETRATIONS WATERTIGHT TO MAINTAIN ROOF WARRANTY. CW HYDRANT SUPPORT MOUNT THREADED HOSE OUTLET ROOF INSULATION MECHANICAL SEAL NOTE: INSTALL PER MANUFACTURER'S RECOMMENDATIONS. SEAL ROOF PENETRATION WATER TIGHT. 1/2" DRAIN LINE TO NEAREST FLOOR SINK OR MOP SINK. SEE FLOOR PLANS FOR LOCATIONS. CONCEAL PIPING IN WALLS AS REQUIRED. EPDM BOOT TO PROTECT MECHANICAL SEAL ROOF DECKING CLAMP TO ROOF DECKING ISOLATION VALVE ROOF HYDRANT RH-1 SEE SPECIFICATIONS. SLOPE TOWARDS DRAIN LOCATION SEE FLOOR PLANS FOR SIZE SLOPE PUMPED CONDENSATE GRAVITY CONDENSATE MAIN CONNECT TO TOP OF GRAVITY DRAIN LINE PROVIDE WYE FITTING TO DIRECT PUMPED CONDENSATE IN DIRECTION OF GRAVITY FLOW m o e y rr Is s e n g I n e e r I n g I n c m e c h a n ic a l | e le c tr ic a l | te c h n o lo g y | c o m m is s io n in g 4 9 4 0 N o rt h 1 1 8 th S tr e e t O m a h a , N E 6 8 1 6 4 P : 4 0 2 .4 9 1 .4 1 4 4 w w w .m o rr is s e y e n g in e e ri n g .c o m M E I P R O J E C T # : E N G I N E E R S O ET A T S P R O F E RBENF A KSA E O N S I AL M CH IAN CAL ∆ ∆ JASON R. E-12778 EICKMEIER SHEET NO. DATE PROJECT KEARNEY TERMINAL SEAL NO . RE VI SI ON S DA TE CIVIL ENGINEER DR AW N BY : DE SI GN ED BY : RE VI EW ED BY : QU AN TI TI ES CH EC KE D BY : ARCHITECT CONSULTANT K E A R N E Y R E G IO N A L A IR P O R T T E R M IN A L E X P A N S IO N K E A R N E Y , N E B R A S K A 2 0 3 7 1 07/29/2022 7/29/2022 M4.1 M EC HA NI CA L D ET AI LS SCALE: NTSM4.1 7 DOUBLE GRADE CLEANOUT DETAIL SCALE: NTSM4.1 8 FLOOR CLEANOUT DETAIL SCALE: NTSM4.1 1 DUCT FITTING DETAILS SCALE: NTSM4.1 2 DIFFUSER CONNECTION DETAILS SCALE: NTSM4.1 3 DUCTLESS SPLIT AC UNIT DETAIL SCALE: NTSM4.1 5 ROOFTOP UNIT DETAIL SCALE: NTSM4.1 4 RETURN AIR TRANSFER DETAIL SCALE: NTSM4.1 10 CONDENSATE DRAIN DETAIL SCALE: NTSM4.1 9 INSTANTANEOUS WATER HEATER DETAIL SCALE: NTSM4.1 11 GAS FIRED UNIT HEATER DETAIL SCALE: NTSM4.1 13 WATER SOFTENER DETAIL SCALE: NTSM4.1 12 LOUVER DETAIL SCALE: NTSM4.1 6 INLINE EXHAUST FAN DETAIL SCALE: NTSM4.1 14 GAS LINE ROOF PENETRATION DETAIL SCALE: NTSM4.1 15 ROOF HYDRANT DETAIL 1 A d de nd um N o. 1 8/ 24 /2 02 2 1 SCALE: NTSM4.1 16 PUMPED CONDENSATE CONNECTION DETAIL P.T.T PRESSURE/TEMPERATURE TEST PORT GLOBE VALVE GATE VALVE BALANCING VALVE ISOLATION VALVE (BALL OR BUTTERFLY) ELBOW DN / ELBOW UP PIPE TEE / PIPE ELBOW UNION STRAINER CHECK VALVE (ARROW INDICATES FLOW) AUTOMATIC CONTROL VALVE TWO-WAY/THREE-WAY PRESSURE REGULATING VALVE (PRV) PRESSURE GAUGE THERMOMETER DOMESTIC COLD WATER (CW) DOMESTIC HOT WATER (HW) (NUMBER INDICATES TEMPERATURE) DOMESTIC HOT WATER CIRCULATION (HWC) (NUMBER INDICATES TEMPERATURE) SANITARY WASTE (BELOW GRADE) SANITARY WASTE (ABOVE GRADE) VENT PIPING STORM PIPING (BELOW GRADE) STORM PIPING (ABOVE GRADE) OVERFLOW STORM PIPING (BELOW GRADE) OVERFLOW STORM PIPING (ABOVE GRADE) ACID WASTE PIPING (BELOW GRADE) ACID WASTE PIPING (ABOVE GRADE) ACID VENT PIPING COMPRESSED AIR PIPING NATURAL GAS PIPING SITE SANITARY PIPING SITE STORM PIPING SITE WATER PIPING HOT WATER SUPPLY PIPING HOT WATER RETURN PIPING COLD WATER SUPPLY PIPING COLD WATER RETURN PIPING CONDENSER WATER SUPPLY PIPING CONDENSER WATER RETURN PIPING REFRIGERANT LIQUID LINE REFRIGERANT SUCTION LINE REFRIGERANT HOT GAS DISCHARGE LINE GAS COCK FLOOR DRAIN - SIZE TYPE ROOF DRAIN - SIZE TYPE OVERFLOW DRAIN - SIZE TYPE HOSE BIBB WALL HYDRANT (NON-FREEZE) VENT THROUGH ROOF INVERT ELEVATION FLOW LINE WATER CLOSET (SEE SPECIFICATIONS FOR TYPE) URINAL (SEE SPECIFICATIONS FOR TYPE) LAVATORY (SEE SPECIFICATIONS FOR TYPE) SINK (SEE SPECIFICATIONS FOR TYPE) ELECTRIC WATER COOLER (SEE SPECIFICATIONS FOR TYPE) MOP SINK (SEE SPECIFICATIONS FOR TYPE) DUCTILE IRON CAST IRON POLY VINYL CHLORIDE HEAT PUMP LOOP SUPPLY PIPING HEAT PUMP LOOP RETURN PIPING GLYCOL WATER SUPPLY PIPING GLYCOL WATER RETURN PIPING AIR VENT COIL CONDENSATE DRAIN (SLOPE TO DRAIN) SOLENOID VALVE SYMBOL DESCRIPTION SYMBOL PLUMBING TYPICAL PIPING DESCRIPTION HYDRONIC HVAC PIPING REFRIGERATION PIPING MECHANICAL SYMBOLS ST OF AW GREASE WASTE (BELOW GRADE) GREASE WASTE (ABOVE GRADE) GW ST OF AW GW GREASE VENT PIPINGGV AV A G SAN W ST HWS HWR CWS CWR CS CR RL RS RD CD GWR GWS HPLR HPLS PVC CI VTR I.E. F.L. WC UR L S EWC MS DI 2" OD-1 2" RD-1 2" D-1 WH HB S SENSOR THERMOSTAT HUMIDISTAT MOTORIZED CONTROL DAMPER WITH ACTUATOR BACKDRAFT DAMPER VOLUME DAMPER FIRE DAMPER WITH SLEEVE AND ACCESS DOOR SMOKE DAMPER WITH SLEEVE AND ACCESS DOOR FIRE/SMOKE DAMPER WITH SLEEVE AND ACCESS DOOR SUPPLY AIR RETURN AIR EXHAUST AIR RELIEF AIR OUTSIDE AIR MIXED AIR FIRE HYDRANT POST INDICATOR VALVE O,S & Y VALVE FLOW SWITCH ALARM CHECK VALVE FIRE SPRINKLER PIPING STANDPIPE PIPING FIRE HOSE CABINET FIRE VALVE CABINET SPRINKLER BRANCH AND HEADS SIDEWALL SUPPLY REGISTER OR GRILLE SIDEWALL RETURN OR EXHAUST REGISTER OR GRILLE SUPPLY AIR REGISTER SUPPLY AIR , OUTSIDE AIR OR MIXED AIR DUCT END OR RISER UP/RISER DN RETURN AIR, EXHAUST AIR OR RELIEF AIR DUCT END OR RISER UP/RISER DN RECTANGULAR DUCTWORK (WIDTH/DEPTH)(IN) (FIRST NUMBER IS SIDE SHOWN) ROUND DUCTWORK (DIAMETER)(IN) (SPIRAL DUCT IN EXPOSED AREAS) TURNING VANES HVAC FIRE PROTECTION 6x6 R-1 100 6x6 R-1 100 6 Ø D-1 100 NECKSIZE (IN), TAG AIRFLOW (CFM) NECKSIZE (IN), TAG AIRFLOW (CFM) NECKSIZE (IN), TAG AIRFLOW (CFM) F SP S.A. R.A. E.A. RLF.A. O.A. M.A. P.I.V. S T H FSFVC FHC FH M B.D.D. V.D. FD SD FSD 12/8 12"Ø PIPING INSULATION SCHEDULE INSULATION TYPE INSULATION THICKNESS VAPOR RETARDER SERVICE REMARKSPIPING SIZES MINERAL FIBER 1/2" YES -ALLCONDENSATE DRAIN (COPPER) FLEXIBLE ELASTOMERIC 1/2" YES -1-1/4" AND SMALLERREFRIGERANT SUCTION (RS) FLEXIBLE ELASTOMERIC 1/2" YES -ALLREFRIGERANT LIQUID (RL) MINERAL FIBER 1/2" YES -ALLDOMESTIC COLD WATER (CW) MINERAL FIBER 1" NO -1/2" TO 2"DOMESTIC HOT WATER (WITH RECIRC.) NONE - - -ALLSANITARY WASTE FLEXIBLE ELASTOMERIC 1/2" YES -ALLROOF DRAIN BODIES (RD & OFD) MINERAL FIBER 1/2" YES -ALLPLUMBING VENTS (24" BELOW ROOF) MINERAL FIBER 1" YES -ALLSTORM DRAIN (ST & OF) REMARKS: 1. - DUCTWORK INSULATION SCHEDULE INSULATION TYPE INSULATION THICKNESS VAPOR RETARDER SERVICE REMARKSDUCTWORK APPLICATION MINIMUM R-VALUE MINERAL FIBER BLANKET 2" YES -ALLSUPPLY AIR CONCEALED ABOVE CEILING R-5 DUCT LINER 1-1/2" YES -RECTANGULARRETURN AIR CONCEALED ABOVE CEILING R-5 DUCT LINER 1" NO (1)RECTANGULARRETURN / XFR AIR PLENUM BOOTS & TRANSFER DUCTS - REMARKS: 1. PLENUM BOOTS SHALL BE CONSTRUCTED OUT OF SHEETMETAL WITH ACOUSTICAL DUCT LINER. SEE DETAILS. MINERAL FIBER BLANKET 2" YES -FROM FAN TO ROOF HOODEXHAUST AIR CONCEALED ABOVE CEILING R-5 MINERAL FIBER BLANKET 2-1/2" YES -ALLOUTDOOR AIR EXPOSED, MECHANICAL ROOM R-8 m o e y rr Is s e n g I n e e r I n g I n c m e c h a n ic a l | e le c tr ic a l | te c h n o lo g y | c o m m is s io n in g 4 9 4 0 N o rt h 1 1 8 th S tr e e t O m a h a , N E 6 8 1 6 4 P : 4 0 2 .4 9 1 .4 1 4 4 w w w .m o rr is s e y e n g in e e ri n g .c o m M E I P R O J E C T # : E N G I N E E R S O ET A T S P R O F E RBENF A KSA E O N S I AL M CH IAN CAL ∆ ∆ JASON R. E-12778 EICKMEIER SHEET NO. DATE PROJECT KEARNEY TERMINAL SEAL NO . RE VI SI ON S DA TE CIVIL ENGINEER DR AW N BY : DE SI GN ED BY : RE VI EW ED BY : QU AN TI TI ES CH EC KE D BY : ARCHITECT CONSULTANT K E A R N E Y R E G IO N A L A IR P O R T T E R M IN A L E X P A N S IO N K E A R N E Y , N E B R A S K A 2 0 3 7 1 07/29/2022 7/29/2022 M5.1 M EC HA NI CA L S CH ED UL ES NATURAL GAS USAGE TABLE METER EQP. TAG GAS LOAD (BTU/h) EXISTING GFDF 150,000 EXISTING GFDF 350,000 EXISTING GFUH-104 60,000 EXISTING GFUH-119 60,000 EXISTING GFUH-M150 60,000 EXISTING RTU 160,000 EXISTING RTU 120,000 EXISTING RTU-121 108,000 EXISTING RTU-123 108,000 EXISTING RTU-131 108,000 Grand total: 10 1,284,000 REMARKS: 1. VERIFY CEILING/WALL CONSTRUCTION PRIOR TO FURNISHING MATERIAL. 2. NOISE CRITERIA (NC) SHALL BE LESS THAN 25 ON DIFFUSERS, REGISTERS AND GRILLES LOCATED IN OCCUPIED SPACES. 3. COLOR TO BE SELECTED BY ARCHITECT. 4. PROVIDE WITH FRAME STYLE N AND PENCIL PROOF BAR SPACING. 5. SIZE TO MATCH EXISTING FLOOR OPENING WITH NO ADDITIONAL CONCRETE WORK. VERIFY SIZE PRIOR TO ORDERING. DIFFUSER REGISTER AND GRILLE SCHEDULE PLAN TAG MFR. MODEL FUNCTION DESCRIPTION DEFLECTION MAX S.P. DROP MATERIAL FINISH NECK SIZE FACE SIZE REMARKS D-1 KRUEGER PLQ SUPPLY PLAQUE DIFFUSER 360° 0.10" STEEL WHITE SEE PLANS 24"x24" (1) (2) D-2 KRUEGER PLQ SUPPLY PLAQUE DIFFUSER 360° 0.10" STEEL WHITE SEE PLANS 12"x12" (1) (2) G-1 KRUEGER 6490 RETURN RECT NECK PERFORATED FACE PERFORATED 0.10" STEEL WHITE SEE PLANS 24"x24" (1) (2) G-2 KRUEGER 6490 RETURN / XFR RECT NECK PERFORATED FACE PERFORATED 0.10" STEEL WHITE SEE PLANS 12"x24" (1) (2) G-3 KRUEGER S80H EXHAUST RECT SINGLE DEFLECTION GRILLE FIXED 3/4", 35° 0.10" STEEL WHITE SEE PLANS NECK SIZE + 1-3/4" (1) (2) LBG-1 KRUEGER 1500 SUPPLY LINEAR BAR GRILLE FIXED - 0° 0.10" ALUMINUM ALUMINUM SEE PLANS VARIES (1) (2) LBG-2 KRUEGER 1800 RETURN LINEAR BAR GRILLE 0° 0.10" ALUMINUM ALUMINUM 50"x4" (5) VARIES (1) (2) (3) (4) REMARKS: 1. HIGH-WALL DUCTLESS AIR-COOLED SPLIT SYSTEM WITH OUTDOOR REMOTE CONDENSING UNIT. PLAN TAG ON SCHEDULE CORRESPONDS WITH INDOOR UNIT. ALL UNITS HAVE OUTDOOR UNIT WITH MATCHING NUMERAL. 2. PROVIDE WITH CONDENSATE PUMP CAPABLE OF A MINIMUM OF 6 FOOT OF HEAD. PUMP RESERVE SHALL HAVE HIGH LEVEL ALARM. 3. CONDENSING UNIT LOCATED ON GRADE. PROVIDE ALL ADDITIONAL REFRIGERANT PIPING ACCESSORIES AS REQUIRED TO ACCOMMODATE REFRIGERANT LINE LENGTH AND CONDENSING UNIT ELEVATION (SEE PLANS). 4. PROVIDE MANUFACTURER'S STANDARD WALL MOUNTED WIRED THERMOSTAT. 5. PROVIDE COMPRESSOR WITH 5-YEAR WARRANTY. 6. PROVIDE WITH MANUFACTURER'S WASHABLE , MILDEW-RESISTANT, FILTERS. 7. PROVIDE LOW AMBIENT TEMPERATURE KIT TO ALLOW COOLING DOWN TO -20°F AMBIENT. PROVIDE BASE PAN HEATER. 8. ELECTRICAL DISCONNECT BY ELECTRICAL CONTRACTOR. SEE ELECTRICAL DRAWINGS. SPLIT SYSTEM AIR CONDITIONER SCHEDULE GENERAL PHYSICAL SIZE AIRFLOW RANGE ELECTRICAL REFRIG. TYPE COOLING REMARKSINDOOR PLAN TAG INDOOR MODEL OUTDOOR MODEL OUTDOOR PLAN TAG MANUFACTURER SERVES CONFIG. INDOOR UNIT (L x W x H) OUTDOOR UNIT (L x W x H) WEIGHT (lbs.) VOLTAGE / PHASE MCA AC / ACCU MOCP ACCU CAPACITY (BTU/h) MIN. NET SEERTONS TOTAL SENSIBLE AC-108 MWMA024 MLA024 ACCU-108 LENNOX OFFICE 108 (1) 47" x 12" x 15" 38" x 13" x 37" 46 485-625-695 208 V / 1 1 / 20 30 R-410A 2.0 24000.0 Btu/h 18480.0 Btu/h 20 (2) (3) (4) (5) (6) (7) (8) AC-118 MWMA024 MLA024 ACCU-118 LENNOX TSA BAG SCREENING 118 (1) 47" x 12" x 15" 38" x 13" x 37" 46 485-625-695 208 V / 1 1 / 20 30 R-410A 2.0 24000.0 Btu/h 18480.0 Btu/h 20 (2) (4) (5) (6) (7) (8) AC-124 MWMA024 MLA024 ACCU-124 LENNOX TSA DATA 124 (1) 47" x 12" x 15" 38" x 13" x 37" 46 485-625-695 208 V / 1 1 / 20 30 R-410A 2.0 24000.0 Btu/h 18480.0 Btu/h 20 (2) (3) (4) (5) (6) (7) (8) REMARKS: 1. DIRECT DRIVE, CEILING MOUNTED, CENTRIFUGAL EXHAUST FAN. 2. PROVIDE WITH DISCONNECT, INTEGRAL BACKDRAFT DAMPER, AND WHITE CEILING GRILLE. 3. DIRECT DRIVE, INLINE, CENTRIFUGAL EXHAUST FAN. 4. PROVIDE WITH DISCONNECT, UNIT MOUNTED SPEED CONTROL, AND MOTORIZED BACKDRAFT DAMPER. THE BACKDRAFT DAMPER SHALL OPERATE AT THE SAME VOLTAGE AS THE EXHAUST FAN MOTOR, AND BE HARDWIRED TO THE POWER SUPPLY FOR THE EXHAUST FAN. 5. EXHAUST FAN TO BE INTERLOCKED WITH LIGHT SWITCH. FAN SCHEDULE GENERAL PHYSICAL SIZE FAN MOTOR REMARKS PLAN TAG MANUFACTURER MODEL SERVES TYPE WEIGHT (lbs) AIRFLOW (CFM) E.S.P. (in-wg) MAXIMUM HP RPM VOLTAGE / PHASE TYPE BHP RPM SONES EF-116 GREENHECK SP-B110 EXHAUST CEILING (1) 12 lb 75 CFM 0.50 0.04 809 2 0.1 950 115 V / 1 ODP (2) (5) EF-125 GREENHECK SQ-97-VG SEE PLANS IN-LINE (3) 60 lb 200 CFM 0.50 0.12 1554 12.3 0.25 1725 115 V / 1 ECM (4) EF-136 GREENHECK SP-B110 EXHAUST CEILING (1) 12 lb 75 CFM 0.50 0.04 900 2 0.1 950 115 V / 1 ODP (2) (5) REMARKS: 1. PROVIDE WITH SINGLE POINT ELECTRICAL CONNECTION AND FACTORY INSTALLED DISCONNECT. 2. PROVIDE WITH FIELD POWERED CONVENIENCE OUTLET. 3. PROVIDE WITH CONDENSER COIL HAIL GUARDS. 4. PROVIDE WITH MULTI-STAGE AIR VOLUME SUPPLY CONTROL. 5. PROVIDE WITH DIFFERENTIAL ENTHALPY ECONOMIZER. 6. PROVIDE WITH HONEYWELL 7-DAY PROGRAMMABLE THERMOSTAT WITH ECONOMIZER CONTROL, HUMIDITY CONTROL, NETWORK (WI-FI) CAPABILITY, AND REMOTE ACCESS. 7. PROVIDE WITH 14" ROOF CURB. 8. PROVIDE WITH ON / OFF HOT GAS REHEAT COIL AND DEHUMIDIFCATION CONTROLS. 9. PROVIDE WITH ECM SUPPLY FAN MOTOR. 10. PROVIDE WITH BAROMETRIC RELIEF. ROOF-TOP UNIT SCHEDULE GENERAL PHYSICAL SIZE AIRFLOW (CFM) SUPPLY FAN ELECTRICAL DX COOLING GAS FIRED HEATING HOT GAS REHEAT REMARKS PLAN TAG MFR. MODEL SERVES WEIGHT MINIMUM OA AIRFLOW (CFM) E.S.P. (in-wg) HP VOLTAGE / PHASE MCA MOCP CAPACITY (BTU/h) AMBIENT AIR TEMP DB (°F) MIN. NET SEER TEMPERATURES (°F) DB / WB - (EAT | LAT) GAS LOAD LAT (°F) DB / WB LAT (°F) DEW PT. CAPACITY (BTU/h)NOM. TONS TOTAL SENSIBLE HIGH (BTU/h) LOW INPUT OUTPUT INPUT OUTPUT RTU-121 LENNOX LGH060H4E SEE PLANS 910 lb 180 2,000 0.50 1.0 208 V / 3 28.0 A 40.0 A 5 52600.0 Btu/h 45600.0 Btu/h 105 °F 17.1 77.0 / 63.0 | 54.7 / 53.6 108,000 86,400 81,000 64,800 77.4 / 63.6 55.3 22,000 (1 - 10) RTU-123 LENNOX LGH048H4E SEE PLANS 910 lb 110 1,600 0.50 1.0 208 V / 3 25.0 A 35.0 A 4 48400.0 Btu/h 39700.0 Btu/h 105 °F 17.6 80.0 / 66.0 | 55.6 / 55.6 108,000 86,400 81,000 64,800 74.9 / 63.1 56.1 20,000 (1 - 10) RTU-131 LENNOX LGH048H4E SEE PLANS 910 lb 385 1,600 0.50 1.0 208 V / 3 25.0 A 35.0 A 4 48400.0 Btu/h 39700.0 Btu/h 105 °F 17.6 80.0 / 66.0 | 55.6 / 55.6 108,000 86,400 81,000 64,800 74.9 / 63.1 56.1 20,000 (1 - 10) REMARKS: 1. ARCHITECTURAL RECESSED WALL HEATER. 2. PROVIDE WITH INTEGRAL THERMOSTAT. 3. CEILING HUNG ELECTRIC UNIT HEATER. 4. PROVIDE WITH DISCONNECT. 5. INFRARED ELECTRIC HEATER. 6. PROVIDE WITH WALL MOUNTING BRACKET AND WIRE GUARD. ELECTRIC HEATER SCHEDULE GENERAL PHYSICAL SIZE ELECTRICAL HEATING REMARKS PLAN TAG MANUFACTURER MODEL SERVES CONFIG. DIMENSIONS (D x W x H) VOLTAGE / PHASE CAPACITY (BTU/h) ELECTRIC HEAT kW / STAGE # OF STAGES EH-101A QMARK HRK SEE PLANS (5) 6" x 3" x 57" 208 V / 1 8,872 3.0 kW 1 (5) (6) EH-101B QMARK HRK SEE PLANS (5) 6" x 3" x 57" 208 V / 1 8,872 3.0 kW 1 (5) (6) EUH-122 KING ELECTRIC KB2003-1-T-B1 SEE PLANS (3) 18" x 15" x 17" 208 V / 1 11,100 3.3 kW 1 (2) (4) EWH-103 QMARK SSAR SEE PLANS (1) 4" x 16" x 20" 208 V / 1 16,378 4.8 kW 1 (2) (4) EWH-126 QMARK SSAR SEE PLANS (1) 4" x 16" x 20" 208 V / 1 16,378 4.8 kW 1 (2) (4) EWH-129 QMARK SSAR SEE PLANS (1) 4" x 16" x 20" 120 V / 1 6,142 1.8 kW 1 (2) (4) REMARKS: 1. BREAK ROOM SINK. 2. INSTANTANEOUS POINT OF USE ELECTRIC WATER HEATER. 3. 57 DEGREE RISE AT 1.0 GPM. 4. DISCONNECT PROVIDED BY ELECTRICAL CONTRACTOR. VERIFY REQUIRED ELECTRICAL CONNECTIONS. 5. PROVIDE WITH 1.0 GPM FLOW RESTRICTOR ELECTRIC WATER HEATER SCHEDULE GENERAL DOMESTIC HOT WATER ELECTRICAL REMARKS PLAN TAG MANUFACTURER MODEL SERVES CONFIGURATION RECOVERY VOLTAGE / PHASE CAPACITY (kW) # OF STAGES IEWH-1 EEMAX SPEX8208T (1) (2) (3) 208 V / 1 8.3 kW 1 (4) (5) REMARKS: 1. ROOF MOUNTED, ROUND, GRAVITY INTAKE VENT. 2. PROVIDE WITH BIRDSCREEN AND 12" ROOF CURB. ROOF HOOD SCHEDULE GENERAL PHYSICAL SIZE AIRFLOW OPTIONS PLAN TAG MFR. MODEL SERVICE OVERALL SIZE WEIGHT NECK SIZE NECK VELOCITY CFM MAX S.P. DROP REMARKS D W H Dia. HD-1 GREENHECK GRSR-8 EXHAUST 20.5" 20.5" 9" 30 lb 8" 405 FPM 150 .017" (1) (2) HD-2 GREENHECK GRSR-8 EXHAUST 20.5" 20.5" 9" 30 lb 8" 541 FPM 200 0.03" (1) (2) REMARKS: 1. BUILDING DOMESTIC COLD AND HOT WATER. 2. SIMPLEX / AQUA-SENSOR / DELAY CONFIGURATION. 3. PROVIDE WITH FULLY INTEGRATED PROGRAMMABLE ELECTRIONC CONTROLLER, 120 / 24 V TRANSFORMER, FRP TANK, AND CORROSION RESISTANT POSITIVE MOTOR-DRIVEN REGENERATION VALVE. 4. WATER SOFTENER SELECTION SHALL BE BASED ON INCOMING WATER PARAMETERS OF: 19 GPG HARDNESS. WATER SOFTENER SCHEDULE PLAN TAG MANUFACTURER MODEL SERVES DIMENSIONS (D x W x H) FLOWRATE (GPM) PRESSURE DROP (PSI) REMARKS CONTINUOUS PEAK CONTINUOUS PEAK WS-1 CULLIGAN CTM-60 (1) 43 x 20 x 66 55 GPM 73 GPM 15 25 (2) (3) (4) REMARKS: 1. GAS FIRED, SEPARATED COMBUSTION, LOW STATIC, AXIAL FAN UNIT HEATER. 2. PROVIDE WITH DISCHARGE LOUVERS, FAN GUARDS, AND FACTORY MOUNT DISCONNECT SWITCH. 3. PROVIDE WITH CONCENTRIC ROOF TERMINATION. 4. PROVIDE WITH INTEGRAL CONTROLS TRANSFORMER AND 24V THERMOSTAT. GAS-FIRED UNIT HEATER SCHEDULE GENERAL PHYSICAL SIZE MOTOR GAS HEATING REMARKS PLAN TAG MANUFACTURER MODEL SERVES CONFIG. WEIGHT HP RPM VOLTAGE / PHASE TYPE INPUT OUTPUT GFUH-104 REZNOR UDZ-60 SEE PLANS (1) 70 lb 0.06 hp 1550 115 V / 1 T.E.F.M. 60,000 49,800 (3) GFUH-119 REZNOR UDZ-60 SEE PLANS (1) 70 lb 0.06 hp 1550 115 V / 1 T.E.F.M. 60,000 49,800 (3) GFUH-M150 REZNOR UDZ-60 SEE PLANS (1) 70 lb 0.06 hp 1550 115 V / 1 T.E.F.M. 60,000 49,800 (3) REMARKS: 1. DRAINABLE LOUVER WITH 6" STATIONARY, 37.5°, EXTRUDED ALUMINUM BLADES WITH .081" WALL THICKNESS. 2. PROVIDE WITH 70% PVDF FINISH. CUSTOM COLOR TO BE SELECTED BY ARCHITECT DURING THE SUBMITTAL PHASE. 3. PROVIDE WITH INTERNAL BIRD SCREEN. 4. PROVIDE WITH EXTENDED SILL. LOUVER SCHEDULE GENERAL PHYSICAL SIZE AIRFLOW OPTIONS PLAN TAG MFR. MODEL SERVES CONFIG. FACE SIZE FREE AREA FREE AREA VELOCITY CFM S.P. DROP REMARKS H W IL-1 RUSKIN ELF6375DX OUTDOOR AIR (1) 12" 18" 0.48 SF 753 FPM 360 CFM 0.09" (2) (3) (4) (E) (E) (E) (E) 1 A d de nd um N o. 1 8/ 24 /2 02 2 1 m o e y rr Is s e n g I n e e r I n g I n c m e c h a n ic a l | e le c tr ic a l | te c h n o lo g y | c o m m is s io n in g 4 9 4 0 N o rt h 1 1 8 th S tr e e t O m a h a , N E 6 8 1 6 4 P : 4 0 2 .4 9 1 .4 1 4 4 w w w .m o rr is s e y e n g in e e ri n g .c o m M E I P R O J E C T # : E N G I N E E R S O ET A T S P R O F E RBENF A KSA E O N S I AL M CH IAN CAL ∆ ∆ JASON R. E-12778 EICKMEIER SHEET NO. DATE PROJECT KEARNEY TERMINAL SEAL NO . RE VI SI ON S DA TE CIVIL ENGINEER DR AW N BY : DE SI GN ED BY : RE VI EW ED BY : QU AN TI TI ES CH EC KE D BY : ARCHITECT CONSULTANT K E A R N E Y R E G IO N A L A IR P O R T T E R M IN A L E X P A N S IO N K E A R N E Y , N E B R A S K A 2 0 3 7 1 07/29/2022 7/29/2022 M5.2 PL UM BI NG FI XT UR E SC HE DU LE S 1 A d de nd um N o. 1 8/ 24 /2 02 2 1 1 TERMINAL EXPANSION KEARNEY REGIONAL AIRPORT (EAR) KEARNEY, NEBRASKA AIP 3-31-0045-036 (CARES) ADDENDUM NO. 1 Attachment No. 6 Revised Plan Sheets (Electrical) Sheets E2.1, E3.1, E6.1, and E6.2 J S T L AD A G AT E L BINS EMPTY BINS EMPTY B IN S EM PT Y L3 PROVISION2 AIT2E N TE R EX IT ETD 224 SS ET D TABLE630 2 TDC/CATTDC/CAT AVS W TM D C EI A TABLE630 2 2 2 ST SO 3'-9"3' 35. 0000 24. 0000 35. 0000 24. 0000 0. 0000 0. 0000 AT 2 60 40 a Ti X B IN S EM PT Y B IN S EM PT Y M J J TC T J J M M M CR CR TV KP S ES ES TV M M J TV ES JJ T V PP CR ES CR ES CR CR ES CR CR CRES CR CR CR CR ES JJ CR ES CR TV M M TV TV TV TV TV TV CR CR CR ES M CR PT CRCR PT PT V V M M CR ES ES ES ES CR PT ES CR CR ES PT ES ES ES PT PT T M T T T T T T T T T T T S T SEE SHEET E0.0 FOR GENERAL ELECTRICAL NOTES RTU (E) RTU-123 RTU-121 RTU-131 EF (E) EF (E) RTU (E) EF (E) T-33 (PART.) LP2-9,R (PART.) ACCU-118 (TYP.)E249 LP3-7 EX. 5 EX. 4 EX. 3 EX. 2 EX. C EX. D EX. EEX. B.9 EX. D.2 1 2 3 EX. 1 EX. B A B C TSA COORDINATION NOTE 1. THE GENERAL CONTRACTOR SHALL COORDINATE WITH THE "SYSTEMS INTEGRATOR" CONTRACTOR (TSA APPROVED EQUIPMENT CONTRACTOR, SEE PROJECT MANUAL). 60 CALENDAR DAYS IN ADVANCE OF THE COMPLETION OF PHASE 1 FOR THE RELOCATION OF THE EXISTING TSA SCREENING EQUIPMENT (INCLUDING BODY SCANNERS, LUGGAGE SCANNERS, ETC.) FROM THE EXISTING TERMINAL BUILDING (PHASE 2) TO THE NEW TERMINAL EXPANSION (PHASE 1). SCHEDULE AND SEQUENCE OF EQUIPMENT RELOCATION WORK SHALL BE COORDINATED WITH AIRPORT PERSONNEL AND COMPLETED OUTSIDE BUSINESS HOURS TO ENSURE NO INTERRUPTION OF AIRLINE SERVICES. THE GENERAL CONTRACTOR WILL NEED TO INCLUDE COSTS TO COORDINATE WITH, AS WELL AS COMPLETE ALL REQUIRED WORK, WITH THE SYSTEM INTEGRATOR CONTRACTOR. 2. CONTRACTORS SHALL COORDINATE WITH TSA, AND THE TSA PROVIDED CONTRACTOR, 60 CALENDAR DAYS IN ADVANCE OF THE COMPLETION OF PHASE 1 FOR THE RELOCATION OF THE EXISTING TSA SCREENING EQUIPMENT (INCLUDING BODY SCANNERS, LUGGAGE SCANNERS, ETC.) FROM THE EXISTING TERMINAL BUILDING (PHASE 2) TO THE NEW TERMINAL EXPANSION (PHASE 1). THE TSA WILL COMPLETE THE RELOCATION OF THE EXISTING TSA SCREENING EQUIPMENT (WITH THEIR OWN CONTRACTOR). NO COSTS SHALL BE INCLUDED IN THE CONTRACTOR’S BID FOR THE RELOCATION OF THE EXISTING TSA SCREENING EQUIPMENT (COSTS COVERED BY OTHERS). THE EQUIPMENT RELOCATION WORK SHALL BE COMPLETED AT NIGHT BY THE TSA, JUST PRIOR TO PUTTING PHASE 1 BUILDING AREAS INTO SERVICE, TO ENSURE NO INTERRUPTION OF AIRLINE SERVICES. 'T' 48" 48" 48" 54" SAS 48" 48" 90" T-13 T-36 T-17 T-15 T-11 T-14 TSA DATA 124 G,44" 44" G,44" 'T' 44" 84" E2.1 1 E201 1"C. 108" BOARDING 132 SECURE HOLDROOM 130 OFFICE 108 44" G,44" 44" 120" 132" 46" 78" 44" 48" 108" FBE4 FBE4 FBE6A T-1,3 E205 FBE4 FBE8A T-4,6,8,10 T-2 (#10) T-12 E206 120" 120" G,WP 132" 132" 132" 132" E208 E208 60"48" M 108" 96" (TYP.) 2 E5.1 120" 120" 120" (TYP.) 5 E5.1 23" LP2-28,N,G LP2-30,N,G 23" G,48" G,48" 36" 36" TSA WORK AREA 123 T-27 (PART.) 44" 44" G,48" G ,4 8" G,48" G,48" LP3-8 LP3-1,3,5 (3#6,#10G.,1'C.) BAGGAGE SYSTEM MCP T-32,G 44" G,WP E225 E225 E225 E227 E228 'LP1' (E) T-35 FBE4 44" 44" G,44" G,WP TSA DATA 124 MECHANICAL 122 TSA BREAK ROOM 125 TSA OFFICE 127 TSA OFFICE 128 PRIVATE SCREENING ROOM 129 RENTAL OFFICE 107 M M M RESTROOM 114 RESTROOM 115 RESTROOM 135 RESTROOM 134 AIRLINE OFFICE 113 TICKETING 110 TSA BAG SCREENING 118 OUTBOUND BAGGAGE 119 ARRIVALS VESTIBULE 103 LOBBY CONCOURSE 102 VESTIBULE 101 OFFICE 109 INBOUND BAGGAGE 104 BAGGAGE CLAIM 105 MECHANICAL M150 NON-SECURE WAITING 111 HALLWAY 112 SECURE HOLDROOM WEST 137 CUST. 117 FAMILY RESTROOM 116 FAMILY RESTROOM 136 G,48" ACCU-124 AC-124 G,WP T-24,G 78" G,40" 'LP2' (E) TSA ENTRY 126 TSA CHECKPOINT 121 EWH-126 'MDP' (E) FAAP 'LP5' (E) FACP E247 (TYP OF 6) E247 E247 G,44" G,44" E247 E247 E247 E247 LP2-20 E247 (TYP OF 8) E247 LP2-19 E239 E247 LP1-8 LP1-10 E247 E247 (TYP OF 3) RENTAL DESK 106 AIRPORT STORAGE 105A G,44" G,44" 132" 132" WS-1 G,44" EWC,24" LP2-26,N,G 84" 'INV-2' 72" E248 'INV-1' 44" 44" (TYP.) E211 EWH-129 AHU (E) AHU (E) GFDF (E) GFDF (E) R,44" E239 E239 CU (E) CU (E) EWH-103 E239 LP2-9 LP2-9 LP2-9 LP2-9 E209E209 E223 E223 E223 E223 T-39 LP2-40 TSA PASSENGER QUEUING 120 LP2-17 LP2-17 LP2-17 (TYP.) 8 E5.1 LP2-40 LP2-7 LP2-7 LP2-7 LP2-7 LP2-11,R LP2-14LP2-14 LP2-14 LP2-10 LP2-10 LP2-10 LP2-8 LP2-8 LP2-22 LP2-21 LP2-24 LP2-23 T-5 T-7 T-30 T-30 T-30 T-30 T-29 T-26 T-26 T-26 T-26 T-25 T-25T-25 T-33 T-33 T-33 T-22 T-22 T-22 T-22 44" T-41,G T-23 IEWH-1 T-31 T-31 T -9 T -3 7 LP1-13 LP1-13 LP1-13 LP1-13 LP1-17 LP1-17 LP1-17 LP1-17 LP1-16 LP1-16 LP1-16 G,44" T-39 E239 LP2-2 84" AC-118 (TYP.) E249 AC-108 ACCU-108 EUH-122 (ABOVE) 54" LP2-36 54" LP2-36 E250 E250 EF-125 EF-116 EF-136 GFUH-119 GFUH-M150 GFUH-104 E239 'LP3' LP3-7 LP3-2 LP 3- 2 LP3-4 LP3-4 LP3-4 LP3-4 LP3-6 LP3-7 LP3-10 LP3-10 LP3-10 LP3-10 LP2-32 LP2-32 LP2-34 LP2-34 LP2-34 T-31120" G,WP 120" 120" LP1-7 36" LP2-38 E247 EX. 5 EX. 4 EX. 3 EX. 2 EX. A EX. C EX. D EX. EEX. B.9 EX. D.2 EX. F 1 2 3 EX. 1 EX. B A B C E251 G,WP G,WPLP5-12 LP5-12 E208 LP1-13 G,WP T-31 G,WP T-26 LP1-19,R,L 108" 108" E252 T -3 8 T -3 8 T-25 T-25 T-28 T-28 LP1-13 LP1-17 LP1-17 E239 E253 E5.1 7 T-57 E254 PP L6-30 1 T-16,18 (#10) T-20 E255 1 EH-101A EH-101B 1 m o e y rr Is s e n g I n e e r I n g I n c m e c h a n ic a l | e le c tr ic a l | te c h n o lo g y | c o m m is s io n in g 4 9 4 0 N o rt h 1 1 8 th S tr e e t O m a h a , N E 6 8 1 6 4 P : 4 0 2 .4 9 1 .4 1 4 4 w w w .m o rr is s e y e n g in e e ri n g .c o m M E I P R O J E C T # : E N G I N E E R S O ET A T S P R O F E RBENF A KSA L O N S I AL E EC ITR CAL ∆ ∆ TOBY J. E-12606 SAMUELSON SHEET NO. DATE PROJECT KEARNEY TERMINAL SEAL NO . RE VI SI ON S DA TE CIVIL ENGINEER DR AW N BY : DE SI GN ED BY : RE VI EW ED BY : QU AN TI TI ES CH EC KE D BY : ARCHITECT CONSULTANT K E A R N E Y R E G IO N A L A IR P O R T T E R M IN A L E X P A N S IO N K E A R N E Y , N E B R A S K A 2 0 3 7 1 07/29/2022 7/29/2022 E2.1 PO W ER P LA NS KEYNOTES E201 TIME CLOCK LOCATION. COORDINATE FINAL INSTALLATION LOCATION WITH TSA PRIOR TO ROUGH-IN AND INSTALLATION OF POWER AND DATA OUTLETS. E205 RECEPTACLE FOR DURESS ALARM RECEIVER, COORDINATE FINAL LOCATION AND HEIGHT WITH TSA PRIOR TO ROUGH-IN AND INSTALLATION. E206 PROVIDE HARDWIRED ELECTRICAL CONNECTION FOR TSA EQUIPMENT. COORDINATE FINAL ROUGH-IN REQUIREMENTS WITH TSA PRIOR TO ROUGH-IN AND INSTALLATION. E208 INSTALL RECEPTACLE AND DATA OUTLET IN CASEWORK. COORDINATE INSTALLATION LOCATION WITH CASEWORK ELEVATION AND APPROVED CASEWORK SHOP DRAWINGS. E209 PROVIDE ELECTRICAL CONNECTION TO LAVATORY. COORDINATE INSTALLATION LOCATION WITH MECHANICAL CONTRACTOR. E211 PROVIDE SINGLE GANG JUNCTION BOX WITH 1"C. TO ABOVE NEAREST ACCESSIBLE CEILING. PROVIDE INSULATED BUSHING ON CONDUIT END. E223 INTERCEPT EXISTING BRANCH CIRCUIT. EXTEND EXISTING BRANCH CIRCUIT AS REQUIRED TO REACH NEW ELECTRICAL PANEL LOCATION. E225 PROVIDE ROUGH-IN AND CONDUIT AND WIRING TO OVERHEAD DOOR SENSOR THAT OPENS/CLOSES DOOR AUTOMATICALLY BASED ON MOTION. SENSOR PROVIDED BY OTHERS AT A FUTURE DATE. COORDINATE REQUIREMENTS WITH OVERHEAD DOOR MANUFACTURER. E227 PROVIDE SINGLE GANG JUNCTION BOX WITH 1"C. TO ABOVE NEAREST ACCESSIBLE CEILING FOR SHADE CONTROLLER. PROVIDE INSULATED BUSHING ON CONDUIT END. E228 PROVIDE THREE GANG JUNCTION BOX WITH 1"C. TO ABOVE NEAREST ACCESSIBLE CEILING FOR SHADE CONTROLLER. PROVIDE INSULATED BUSHING ON CONDUIT END. E239 CONNECT TO EXISTING BRANCH CIRCUIT INDICATED. E247 CONNECT NEW RECEPTACLE TO EXISTING CIRCUIT RETAINED DURING DEMOLITION. E248 CONNECT NEW DOOR MOTOR TO EXISTING CIRCUIT MAINTAINED DURING DEMOLITION. EXTEND EXISTING CIRCUIT AS REQUIRED. E249 SEE MECHANICAL CONNECTION SCHEDULE FOR ELECTRICAL INFORMATION. E250 PROVIDE RECEPTACLE FOR LIGHTED MIRROR. COORDINATE INSTALLATION LOCATION WITH MANUFACTURER. CONNECT RECEPTACLE DOWN STREAM OF ROOM OCCUPANCY SENSOR SO MIRROR OPERATES DURING OCCUPANCY. SEE LIGHTING PLANS FOR SENSOR LOCATION. E251 PROVIDE CONDUIT AND WIRING AS REQUIRED TO RELOCATE EXISTING OVERHEAD DOOR CONTROLLER. E252 PROVIDE 1" CONDUIT CONCEALED IN WALL AND CASEWORK FOR SECURITY CABLING. PROVIDE INSULATED BUSHING ON CONDUIT ENDS. E253 PROVIDE 120V TO 24V TRANSFORMER FOR OPERATION OF MOTORIZED DAMPER. CONTROL WIRING BY MECHANICAL CONTRACTOR. E254 PROVIDE ELECTRICAL CONNECTION FOR FIRE SPRINKLER AIR COMPRESSOR. COORDINATE INSTALLATION LOCATION WITH FIRE SPRINKLER CONTRACTOR. E255 PROVIDE POWER POLE TO SERVE EQUIPMENT, LEGRAND # 30TP-4WH. PROVIDE WITH 30TP-J ACCESSORY TO INSTALLATION OF SPECIAL PURPOSE RECETPACLE. COORDINATE FINAL LOCATION OF POLE WITH TSA EQUIPMENT INSTALLATION. COORDINATE FINISH COLOR WITH ARCHITECT PRIOR TO ORDERING. SCALE:N 1/8" = 1'-0"E2.1 3 ROOF PLAN - POWER SCALE: 1/4" = 1'-0"E2.1 1 ENLARGED TSA DATA - POWER SCALE:N NOT TO SCALEE2.1 4 FIRST FLOOR - POWER 1 Ad de nd um N o. 1 8/ 24 /2 02 2 1 R R J L AD A G AT E L BINS EMPTY BINS EMPTY B IN S EM PT Y L3 PROVISION2 AIT2EN TE R EX IT ETD 224 SS ET D TABLE630 2 TDC/CATTDC/CAT AVS W TM D C EI A TABLE630 2 2 2 ST SO 3'-9"3' 35. 0000 24. 0000 35. 0000 24. 0000 0. 0000 0. 0000 AT 2 60 40 a Ti X B IN S EM PT Y B IN S EM PT Y M J J TC T J J M M M CR CR TV F KP F ES ES TV F M M J TV ES R R F JJ F F PP CR ES CR ES CR CR ES CR CR CRES CR CR CR CR ES S F F F F F F F JJ CR ES CR F TV PP M M F F F F F F F F F F F F F F T F F TV TV TV TV TV TV CR CR CR ES F F M CR PT CRCR PT PT M M CR ES ES ES ES CR PT ES CR CR ES PT ES ES ES PT PT T T T T T T T T T T T F F F F R R F T SEE SHEET E0.0 FOR GENERAL ELECTRICAL NOTES RTU-123 RTU-121 RTU-131 EF (E) EF (E) RTU (E) RTU (E) EF (E) (TYP.)E337 ACCU-118 EX. 5 EX. 4 EX. 3 EX. 2 EX. A EX. C EX. D EX. EEX. B.9 EX. D.2 1 2 3 EX. 1 EX. B A B C TSA COORDINATION NOTE 1. THE GENERAL CONTRACTOR SHALL COORDINATE WITH THE "SYSTEMS INTEGRATOR" CONTRACTOR (TSA APPROVED EQUIPMENT CONTRACTOR, SEE PROJECT MANUAL). 60 CALENDAR DAYS IN ADVANCE OF THE COMPLETION OF PHASE 1 FOR THE RELOCATION OF THE EXISTING TSA SCREENING EQUIPMENT (INCLUDING BODY SCANNERS, LUGGAGE SCANNERS, ETC.) FROM THE EXISTING TERMINAL BUILDING (PHASE 2) TO THE NEW TERMINAL EXPANSION (PHASE 1). SCHEDULE AND SEQUENCE OF EQUIPMENT RELOCATION WORK SHALL BE COORDINATED WITH AIRPORT PERSONNEL AND COMPLETED OUTSIDE BUSINESS HOURS TO ENSURE NO INTERRUPTION OF AIRLINE SERVICES. THE GENERAL CONTRACTOR WILL NEED TO INCLUDE COSTS TO COORDINATE WITH, AS WELL AS COMPLETE ALL REQUIRED WORK, WITH THE SYSTEM INTEGRATOR CONTRACTOR. 2. CONTRACTORS SHALL COORDINATE WITH TSA, AND THE TSA PROVIDED CONTRACTOR, 60 CALENDAR DAYS IN ADVANCE OF THE COMPLETION OF PHASE 1 FOR THE RELOCATION OF THE EXISTING TSA SCREENING EQUIPMENT (INCLUDING BODY SCANNERS, LUGGAGE SCANNERS, ETC.) FROM THE EXISTING TERMINAL BUILDING (PHASE 2) TO THE NEW TERMINAL EXPANSION (PHASE 1). THE TSA WILL COMPLETE THE RELOCATION OF THE EXISTING TSA SCREENING EQUIPMENT (WITH THEIR OWN CONTRACTOR). NO COSTS SHALL BE INCLUDED IN THE CONTRACTOR’S BID FOR THE RELOCATION OF THE EXISTING TSA SCREENING EQUIPMENT (COSTS COVERED BY OTHERS). THE EQUIPMENT RELOCATION WORK SHALL BE COMPLETED AT NIGHT BY THE TSA, JUST PRIOR TO PUTTING PHASE 1 BUILDING AREAS INTO SERVICE, TO ENSURE NO INTERRUPTION OF AIRLINE SERVICES. TSA E311 E5.2 5 "TGB-TSA" 7 E5.2 1D(T) SAS WALL SPACE FOR PHYSICAL SECURITY SYSTEM 1D(T) (FUT) WALL SPACE FOR PUNCHDOWN BLOCKS E322 1D(T) E312 E313 E314 E315 E316 E318 E319 E310 8 E5.2 2 E3.1 3 2D(T) 2D 2D(T) 2D(CT),1D 2D(CT) WAP WAP WAP WAP WAP WAP WAP WAP (TYP.)E302 (TYP.)E304 (TYP.)E303 4D 4D 2D 2D(T),1C(T) 2D(T) PRIVATE SCREENING ROOM 129 TSA BAG SCREENING 118 TSA OFFICE 127 TSA OFFICE 128 TSA WORK AREA 123 SECURE HOLDROOM 130 BOARDING 132 OFFICE 108 2D 1D 1D 2D(T) 2D(T) 2D(T) 4D(T) 1V(T) 4D(CT) 6D(CT) 2D WAP WAP WAP WAP WAP 2D1D M E324 E324 B A A B A C C A A B A (TYP.) 6 E5.1 2D(T) 2D(T) B C (2) 4" (2) 4" E320 (1) 4" E320 E326 2D E326 E335 0D 2D(T) 4D(T)4D(T) 1V(T) 2D(T) TSA DATA 124 TSA BREAK ROOM 125 MECHANICAL 122 WAP 4D M M M SECURE HOLDROOM WEST 137 TSA PASSENGER QUEUING 120 NON-SECURE WAITING 111 HALLWAY 112 RESTROOM 114 RESTROOM 134 RESTROOM 135 RESTROOM 115 ALCOVE 133 FAMILY RESTROOM 136 FAMILY RESTROOM 116 AIRLINE OFFICE 113 2D(T) "TDC1 A/B" "TDC2 A/B" "STSO A/B""WTMD 1/2" "ETD1 / SPARE" "WTMD 1/2" "AT/CT 1/2" "AVS/AT 1/2" "AIT 1/2" "ETD 1/2" "PSR 1/2" 2D B B BB B WAP B FAAP B C A C F A C P WAP 6 E5.2 RACK A E309 2D 2D 2D 2D(T),1C(T) 2D 2D 2D(T),1C(T) 2D 2D 2D B WAP B E323 E323 B AHU (E) AHU (E) GFDF (E)GFDF (E) 2D (2) 4" (2) 4" (2) 4" (2) 4" (2) 4" E341 (2) 4" A B 8 E5.2 (2) 2" (2) 2" (TYP.)E321 E320 E320 EX. 5 EX. 4 EX. 3 EX. 2 EX. A EX. C EX. D EX. EEX. B.9 EX. D.2 EX. F 1 2 3 EX. 1 EX. B A B C 2D(T) EXTERIOR DOUBLE DOOR, INTERIOR READER 1D 1D EXISTING PHONE EQUIPMENT CABINET E305 E310 WALL SPACE FOR REMOTE ALARM INDICATORS E342 OUTBOUND BAGGAGE 119 SECURE HOLDROOM EAST 131 1 2D(T) m o e y rr Is s e n g I n e e r I n g I n c m e c h a n ic a l | e le c tr ic a l | te c h n o lo g y | c o m m is s io n in g 4 9 4 0 N o rt h 1 1 8 th S tr e e t O m a h a , N E 6 8 1 6 4 P : 4 0 2 .4 9 1 .4 1 4 4 w w w .m o rr is s e y e n g in e e ri n g .c o m M E I P R O J E C T # : E N G I N E E R S O ET A T S P R O F E RBENF A KSA L O N S I AL E EC ITR CAL ∆ ∆ TOBY J. E-12606 SAMUELSON SHEET NO. DATE PROJECT KEARNEY TERMINAL SEAL NO . RE VI SI ON S DA TE CIVIL ENGINEER DR AW N BY : DE SI GN ED BY : RE VI EW ED BY : QU AN TI TI ES CH EC KE D BY : ARCHITECT CONSULTANT K E A R N E Y R E G IO N A L A IR P O R T T E R M IN A L E X P A N S IO N K E A R N E Y , N E B R A S K A 2 0 3 7 1 07/29/2022 7/29/2022 E3.1 SP EC IA L S YS TE M S P LA NS KEYNOTES E302 PROVIDE (1) CATEGORY 6A DATA CABLE TO EACH WIRELESS ACCESS POINT. PROVIDE 30' SERVICE LOOP. TERMINATE WITH PLENUM RATED SURFACE BOX MOUNTED ABOVE ACCESSIBLE CEILING. PROVIDE 3' PATCH CORD FOR CONNECTION TO OWNER-FURNISHED WIRELESS ACCESS POINT. E303 PROVIDE (2) CATEGORY DATA CABLES FOR EACH TELEVISION LOCATION, UNLESS OTHERWISE INDICATED. E304 PROVIDE (1) CATEGORY DATA CABLE FOR CONNECTION TO POE SECURITY CAMERA. PROVIDE 20' SERVICE LOOP. TERMINATE WITH PLENUM RATED SURFACE BOX MOUNTED ABOVE ACCESSIBLE CEILING. PROVIDE 3' PATCH CORD FOR CONNECTION TO SECURITY CAMERA (CAMERA BY OWNER SECURITY VENDOR). E305 PROVIDE (2) CATEGORY DATA CABLES FOR CONNECTION TO FACP. TERMINATE WITH MODULAR JACK IN FACP. EXTEND CABLES TO ABOVE SERVICE PROVIDER DEMARC, COIL CABLES AND LEAVE UN-TERMINATED. E309 FIRE ALARM CONTRACTOR TO PROVIDE MONITORING OF FLOW AND TAMPER SWITCHES AT FIRE ALARM RISER. VERIFY LOCATION AND QUANTITY OF SWITCHES REQUIRED WITH FIRE SPRINKLER CONTRACTOR PRIOR TO ROUGH-IN. E310 PROVIDE COMMUNICATIONS BACKBOARD, 3/4" A/C GRADE A SIDE OUT, ALL SIDES PAINTED WITH 2 COATS OF WHITE FIRE RATED PAINT, (TYP) E311 PROVIDE 12" HORIZONTAL LADDER CABLE RUNWAY, CPI PART#: 10250-712 (OR APPROVED EQUAL), (TYP) E312 PROVIDE WALL ANGLE SUPPORT KIT FOR EACH INSTANCE LADDER RUNWAY TERMINATES AT WALL, CPI PART#: 11421-712 (OR APPROVED EQUAL), (TYP) E313 PROVIDE 12" VERTICAL LADDER CABLE RUNWAY FOR EACH INSTANCE CABLING DROPS VERTICALLY FROM CONDUITS INTO HORIZONTAL RUNWAY, CPI PART#: 10250-712 (OR APPROVED EQUAL), (TYP) E314 PROVIDE LADDER RUNWAY ADDITIONAL CORNER RADIUS, CPI PART#: 11959-715 (OR APPROVED EQUAL), (TYP) E315 PROVIDE 12" TRIANGULAR SUPPORT BRACKET THROUGHOUT ENTIRE ROOM FOR MOUNTING RUNWAY TO WALL, CPI PART#: 11746-712 (OR APPROVED EQUAL), (TYP) E316 PROVIDE ONE (1) LADDER RUNWAY TRAPEZE SUPPORT BRACKET EVERY 5', CPI PART#: 34730-712. PROVIDE INDIVIDUAL SUPPORTS FOR EACH END OF BRACKET, (TYP) E318 BOND LADDER RUNWAY TO COMMUNICATIONS GROUND BAR WITH #6 AWG THHN, (TYP) E319 BOND EACH SECTION OF LADDER RUNWAY NOT BONDED WITH A FACTORY WELD, REMOVE POWDER COAT UNDER BONDING CONNECTION, (TYP) E320 PROVIDE HILTI CP 653 SPEED SLEEVE (OR EQUAL BY STI), MECHANICAL FIRESTOP DEVICE FOR WALL PENETRATIONS. PROVIDE SIZE AND QUANTITY INDICATED ADJACENT TO KEYNOTE, (TYP) E321 PROVIDE HILTI CS-SL SA SMOKE AND ACOUSTIC SLEEVE (OR EQUAL BY STI), FOR WALL PENETRATIONS. PROVIDE SIZE AND QUANTITY INDICATED ADJACENT TO KEYNOTE, (TYP) E322 PROVIDE 1-1/2"C. FROM ABOVE OVERHEAD LADDER RUNWAY TO ROOF FOR ROOF MOUNTED IT EQUIPMENT BY OTHERS. PROVIDE WEATHERHEAD ON CONDUIT END ABOVE ROOF, COORDINATE ROOF PENETRATION WITH GENERAL CONTRACTOR AND ROOFING MANUFACTURER. E323 PROVIDE REMOTE CLOSED CONTACT FOR LOCAL LOCKDOWN AND PROGRAMMED SCHEDULING OF DOOR INDICATED. E324 PROVIDE FIRE ALARM RELAY AT CONTROLLER OF DOOR INDICATED, COORDINATE FINAL LOCATION WITH DOOR MANUFACTURER. RELAY SHALL RELEASE DOOR WHEN A FIRE ALARM EVENT IS TRIGGERED. COORDINATE PROGRAMMING WITH DOOR MANUFACTURER. E326 INSTALL SEPARATE DATA CABLES BETWEEN EQUIPMENT LOCATIONS INDICATED, CABLING SHALL NOT NEED BE TERMINATED TO DATA RACK. TERMINATE AND TEST BOTH END TO DATA CABLES TO FACEPLATE JACKS FOR EQUIPMENT INTERCONNECTIONS BY OTHERS. E335 PROVIDE 16/4 CABLE FROM X-RAY ALARM MONITORING POINT TO BUILDING LEO ALARM HEADEND LOCATION. COORDINATE INSTALLATION LOCATIONS WITH TSA AND XRAY EQUIPMENT MANUFACTURER. COORDINATE FINAL WIRING TYPE WITH TSA AND X-RAY EQUIPMENT MANUFACTURER. E337 DUCT SMOKE DETECTOR(S) AND RELAY. PROVIDE DUCT MOUNTED SMOKE DETECTOR, FAN SHUTDOWN RELAY, REMOTE INDICATOR, CONTROLS CONNECTIONS FOR SHUT-DOWN, AND CONNECTION TO FIRE ALARM CONTROL PANEL. SHUT DOWN OF UNIT SHALL BE FROM DUCT DETECTOR ALARM. LOCATE REMOTE INDICATOR ON ADJACENT WALL IN ROOM. E341 PROVIDE WHITE STI EZ PATH SMOKE AND ACOUSTIC SLEEVE THROUGH CEILING FOR DATA CABLING. PROVIDE SIZE AND QUANTITY INDICATED ADJACENT TO KEYNOTE, (TYP) E342 PROVIDE CONCEALED PANIC BUTTON IN TICKETING CASEWORK. ACTIVIATION OF BUTTON SHALL TIE INTO CITY DISPATCH CENTER. COORDINATE PROGRAMMING AND ALERT NOTIFICATIONS WITH OWNER. SCALE:N 1/8" = 1'-0"E3.1 2 ROOF PLAN - SPECIAL SYSTEMS SCALE: 1/4" = 1'-0"E3.1 3 ENLARGED TSA DATA ROOM SCALE:N 1/8" = 1'-0"E3.1 4 FIRST FLOOR - SPECIAL SYSTEMS 1 Ad de nd um N o. 1 8/ 24 /2 02 2 1 GENERAL REQUIREMENTS: A. CONTRACTOR SHALL VERIFY CATALOG NUMBERS AND INSTALLATION REQUIREMENTS PRIOR TO ORDERING. NOTIFY ENGINEER OF ANY CONFLICTS WITH PROPOSED INSTALLATION. B. ALL LUMINAIRES SHALL BE 'BUY AMERICA' COMPLIANT. LUMINAIRE SCHEDULE NOTES: 1. LUMINAIRE SHALL BE CONSIDERED EQUAL AS MANUFACTURED BY: ACUITY BRANDS, HUBBELL, COOPER, OR PHILIPS LIGHTING. 2. LUMINAIRE SHALL BE CONSIDERED EQUAL AS MANUFACTURED BY: GOTHAM, PATHWAY, PRESCOLITE, OR COOPER PORTFOLIO. 3. REFER TO PLANS FOR MOUNTING REQUIREMENTS SUCH AS WALL MOUNT, END MOUNT, CEILING MOUNT AND PROVIDE LUMINAIRES ACCORDINGLY. PROVIDE DIRECTIONAL CHEVRON ARROWS AS INDICATED ON PLANS. 4. REFER TO PLANS FOR RUN LENGTHS AND CONFIGURATIONS REQUIRED. LUMINAIRE SHALL BE CONTINUOUS FOR ENTIRE LENGTHS OF WALLS. PRIOR TO ORDERING CONTRACTOR SHALL VERIFY WALL DIMENSIONS. GENERAL REQUIREMENTS: A. CONTRACTOR SHALL VERIFY CATALOG NUMBERS AND INSTALLATION REQUIREMENTS PRIOR TO ORDERING. NOTIFY ENGINEER OF ANY CONFLICTS WITH PROPOSED INSTALLATION. B. INSTALL PER MANUFACTURER'S INSTRUCTIONS. C. CONFIRM FINAL LOCATION WITH ARCHITECT AND OWNER PRIOR TO ROUGH-IN. D. VERIFY FINISH AND FLOORING TYPE PRIOR TO ORDERING. E. SAWCUT EXISTING CONCRETE FLOORS AS REQUIERD TO INSTALL NEW BOXES. FLOORBOX SCHEDULE NOTES: 1. FLOORBOX SHALL BE CONSIDERED EQUAL AS MANUFACTURED BY: WIREMOLD, HUBBELL. 2. PROVIDE WITH INTERNAL RJ DEVICE BRACKETS AND ALL OTHER MOUNTING HARDWARE AS REQUIRED. 3. PROVIDE CONDUIT FROM CONNECTOR ROUTED UNDERFLOOR, UP CONCEALED IN WALL, AND STUBBED TO ABOVE ACCESSIBLE CEILING SPACE. TERMINATE WITH INSULATING BUSHING. 4. COORDINATE FINISH AND COLOR WITH ARCHITECT PRIOR TO OREDERING. 5. PROVIDE L5-15 RECEPTACLE FOR SPECIALTY EQUIPMENT, FIELD VERIFY RECEPTACLE CONFIGURATION WITH TSA EQUIPMENT. 6. PROVIDE WITH BARE CONCRETE / TERRAZO RING # EFB45-CTR. GENERAL REQUIREMENTS: A. VERIFY VOLTAGE, AND PHASE WITH MECHANICAL CONTRACTOR AND APPROVED SHOP DRAWINGS PRIOR TO INSTALLATION. SCHEDULE NOTES: 1. MECHANICAL EQUIPMENT PROVIDED WITH INTEGRAL DISCONNECT. 2. PROVIDE 2#12,#12G,1/2"C. BETWEEN INDOOR AND OUTDOOR UNIT. MECHANICAL UNIT DERIVES POWER FROM AUXILIARY MECHANICAL EQUIPMENT. EQUIPMENT LISTED IN (). 3. PROVIDE 1/2"C. FOR CONTROL WIRING BETWEEN INDOOR AND OUTDOOR UNIT. ROUTE CONDUIT WITH REFRIGERANT PIPING. 4. PROVIDE VOLTAGE MATCHED ELECTRICAL CONNECTION TO MOTORIZED DAMPER ON EQUIPMENT. 5. CONNECT FAN DOWN STREAM OF ROOM OCCUPANCY SENSOR SO FAN OPERATES DURING OCCUPANCY. 6. CONNECT TO BRANCH CIRCUIT INDICATED ON FLOOR PLANS. 7. DISCONNECT SHIPPED LOOSE FROM EQUIPMENT, ELECTRICAL CONTRACTOR TO CONNECT TO EQUIPMENT AND BRANCH CIRCUIT TO DISCONNECT PROVIDED. 8. ROUTE CONDUITS CONCEALED AS BEST AS POSSIBLE IN EXISTING CEILING AREA. PAINT EXPOSED CONDUITS TO MATCH CEILING / WALL COLORS. TS S EXIT L 6" EXIT DOOR 6 4 STANDARD DOOR 1 DEVICES: 2 3 4 5 6 N O T E 4 DIMMER SWITCH F I R E F TEMPERATURE SENSORTHERMOSTAT NOTE 1 WALL SWITCH FLOOR C WALL BOX CR SCTC NOTES: ALIGN DEVICES VERTICALLY AND HORIZONTALLY WHEREVER POSSIBLE. NOT ALL DEVICES OR CONFIGURATIONS ARE DEPICTED ON THIS DETAIL. FOR ANY CONFIGURATIONS WITH FOUR OR MORE DEVICES, COORDINATE ARRANGEMENT WITH THE ENGINEER PRIOR TO ROUGH-IN. SEE FLOOR PLANS FOR INDIVIDUAL DOOR REQUIREMENTS. WHERE MULTIPLE SWITCHES OR WALL BOX DIMMERS ARE GANGED TOGETHER, ALIGN FIRST GANG WITH DEVICES ABOVE AND ADD DEVICES TO THE RIGHT AS REQUIRED. DIMENSIONS ARE TO BE MEASURED FROM OUTSIDE EDGE OF DOOR FRAME OR TRIM. WHERE SIDE LIGHT WINDOWS ARE PROVIDED, DIMENSIONS SHOULD BE MEASURED FROM OUTSIDE EDGE OF SIDE LIGHT WINDOW FRAME OR TRIM. ALL DEVICES SHALL BE LOCATED TO MAINTAIN ALL A.D.A. MOUNTING HEIGHT REQUIREMENTS AND SUCH THAT CENTER OF ADJACENT DEVICES ARE AT SAME ELEVATION (TYPICALLY 44" A.F.F. TO CENTER OF DEVICE). NOTIFY ENGINEER OF ANY CONFLICTS WITH THE PROPOSED INSTALLATION. WALL SWITCH, WALL OCCUPANCY SENSOR SWITCH, WALL BOX DIMMER SWITCH, OR ENTRY STATION THERMOSTAT, TEMPERATURE SENSOR, OR CARBON DIOXIDE SENSOR ROUGH-IN FIRE ALARM AUDIO/VISUAL INDICATING DEVICE FIRE ALARM PULL STATION ACCESS CONTROL CARD READER EXIT SIGN TV CONTROL SHADE CONTROL ACCESS CONTROL CARD READER WALL OCCUPANCY SENSOR SWITCH CARBON DIOXIDE SENSOR FIRE ALARM PULL STATION ENTRY STATION 3 1 NOTE 2 44 " U .N .O . 6" 2 CL CL CL 6" 3 CL 6" 6" 5 44 " U .N .O . LC NOTE 3 (TYPICAL) 1. 2. 3. 4. NOTE 3 (TYPICAL) 84 " 84 " 1 (XX-##) 3[a] 2[b] 2[b] 2[b] 2[b] 2[b] 2[b] 3[a]3[a] [a] (XX-##) [b] (XX-##) 1 [a] 4[a] 4[a]4 NL [a,b] [a] [b]LS1 LS2 LS3 PP PP PP [a] (XX-##) SUBSCRIPT "NL" DENOTES NIGHT LIGHT HATCHING INDICATES LUMINAIRE WITH INTEGRAL BATTERY OR CONNECTED TO EMERGENCY CIRCUIT CONNECT LUMINAIRES AND CONTROL DEVICE TO CIRCUIT INDICATED CONNECT LUMINAIRES TO LIGHTING CONTROL DEVICE WITH MATCHING SUBSCRIPT SEE LIGHTING CONTROL SEQUENCE OF OPERATIONS SEE LIGHTING CONTROL DEVICE SCHEDULE AND SPECIFICATIONS CONNECT LIGHTING CONTROL DEVICE TO LUMINAIRES IN ROOM UNLESS NOTED OTHERWISE NOTE: NOT ALL CONFIGURATIONS ARE SHOWN ON TYPICAL PLAN. m o e y rr Is s e n g I n e e r I n g I n c m e c h a n ic a l | e le c tr ic a l | te c h n o lo g y | c o m m is s io n in g 4 9 4 0 N o rt h 1 1 8 th S tr e e t O m a h a , N E 6 8 1 6 4 P : 4 0 2 .4 9 1 .4 1 4 4 w w w .m o rr is s e y e n g in e e ri n g .c o m M E I P R O J E C T # : E N G I N E E R S O ET A T S P R O F E RBENF A KSA L O N S I AL E EC ITR CAL ∆ ∆ TOBY J. E-12606 SAMUELSON SHEET NO. DATE PROJECT KEARNEY TERMINAL SEAL NO . RE VI SI ON S DA TE CIVIL ENGINEER DR AW N BY : DE SI GN ED BY : RE VI EW ED BY : QU AN TI TI ES CH EC KE D BY : ARCHITECT CONSULTANT K E A R N E Y R E G IO N A L A IR P O R T T E R M IN A L E X P A N S IO N K E A R N E Y , N E B R A S K A 2 0 3 7 1 07/29/2022 7/29/2022 E6.1 EL EC TR IC AL SC HE DU LE S LUMINAIRE SCHEDULE MARK DESCRIPTION MANUFACTURER CATALOG NUMBER LIGHT SOURCE ELECTRICAL FINISH MOUNTING ACCEPTABLE MANUFACTURERS REMARKSSPEC. CCT T...

City of Kearney, NE 68847, United StatesLocation

Address: City of Kearney, NE 68847, United States

Country : United StatesState : Nebraska

You may also like

Adirondack Regional Airport (SLK) -- Airport Terminal Revitalization

Due: 14 May, 2024 (in 16 days)Agency: Passero Associates Engineering Archtecture

TSA RDU TERMINAL 1 REMODEL RALEIGH DURHAM INTERNATIONAL AIRPORT, RALEIGH, NC 27604-3889

Due: 30 Apr, 2024 (in 2 days)Agency: PUBLIC BUILDINGS SERVICE