RPR Potable Water Lines, Area 1

expired opportunity(Expired)
From: Federal Government(Federal)
FA5575-19-B-0005

Basic Details

started - 16 Aug, 2019 (about 4 years ago)

Start Date

16 Aug, 2019 (about 4 years ago)
due - 30 Aug, 2019 (about 4 years ago)

Due Date

30 Aug, 2019 (about 4 years ago)
Bid Notification

Type

Bid Notification
FA5575-19-B-0005

Identifier

FA5575-19-B-0005
Department of the Air Force

Customer / Agency

Department of the Air Force

Attachments (13)

unlockUnlock the best of InstantMarkets.

Please Sign In to see more out of InstantMarkets such as history, intelligent business alerts and many more.

Don't have an account yet? Create a free account now.

Added:Jul 12, 2019 9:36 am The United States Air Force intends to issue solicitation FA5575-19-B-A005 to solicit proposals for a Firm-Fixed Price contract to Replace potable water lines at Morón AB, Spain. The magnitude of construction for this project is estimated to be between $500,000 and $1,000,000 U.S. Dollars. The period of performance for this project is estimated at 360 calendar days.A solicitation package will be available on the Federal Business Opportunities website at www.fbo.gov on or after 29 July 2019.In accordance with the Agreement of Defense and Cooperation between the Kingdom of Spain and the United States of America, any contract resulting from this notice/solicitation can only be entered into with companies authorized to carry out these activities in Spain under Spanish law. Companies must meet the requirements established by Spanish legislation for execution of Government works. In addition, in
accordance with the Agreement of Defense Cooperation between the U.S.A. and the Kingdom of Spain, Annex 6, Article 1 (5) " Spanish material, labor, and equipment shall be used whenever feasible and consistent with the requirements".NOTE: THIS SOLICITATION IS INTENDED ONLY FOR LOCAL SOURCES IN ACCORDANCE WITH FEDERAL ACQUISITION REGULATION 5.202(a)(12). LOCAL SOURCES ARE THOSE SOURCES NORMALLY RESIDENT, LICENSED AND REGISTERED TO CONDUCT CONSTRUCTION BUSINESS IN SPAIN. OFFERS FROM NON-LOCAL SOURCES WILL NOT BE CONSIDERED UNDER THIS SOLICITATION.The work includes, but is not limited to:1.1 Basic Package:a. Demolish existing underground pipe, manholes, valves, valve boxes, backflow preventers, water meters, fire hydrants, air relief valves and other existing elements and accessories, as indicated in the drawings. Those pipe sections that are no longer part of the potable water distribution system shall be capped.b. Furnish and install underground pipe, valves, valve boxes, "T" connections, backflow preventers, water flow meters, fire hydrants, and related elements and accessories, as indicated in the drawings.c. Paint new barrel type hydrants, including hydrant number. Install bollards around the new barrel type fire hydrants. Install bollards around the existing barrel type fire hydrants to remain. Disassemble the existing 4 1⁄2" quick connectors in the barrel type hydrants to demolish and reinstall them in the new barrel type fire hydrants. Furnish and install similar 4 1⁄2" quick connectors for the new hydrants, if necessary. Perform flow test in each hydrant (said tests will be performed by the Government, but the Contractor will be present during the test performance).d. Perform directional boring for the passage of new water piping below pavements, as indicated on the drawings. The drill opening will be protected by high density PN10 polyethylene jacket with an interior diameter big enough to easily introduce the new pipe including its electro-welded fittings.e. Repair leak #1: Replace PVC DN200 pipe with PE100 PN10 DN200 high density polyethylene pipe from the exterior of the manhole to the existing gate valve.f. Repair leak #2: Replace PVC DN200 pipe with PE100 PN10 DN200 high density polyethylene pipe, replace PVC "T" with 200x200x160 electro-welded polyethylene "T", replace existing lateral pipe with high density polyethylene pipe PE100 PN10 DN160, replace gate valve, valve box and above ground barrel type hydrant. Install 4 1⁄2"quick connection at the new hydrant. The gate valve and valve box for hydrant shall be furnished by the Government and installed by the Contractor.g. Repair leak #3: Replace PVC DN200 pipe with PE100 PN10 DN200 high density polyethylene pipe from the exterior of the manhole to the existing gate valve.h. Repair leak #4: Replace PVC DN200 pipe with PE100 PN10 DN200 high density polyethylene pipe, replace PVC "T" with 200x200x160 electro-welded polyethylene "T", replace existing lateral pipe with high density polyethylene pipe PE100 PN10 DN160, replace gate valve, valve box and above ground barrel type hydrant. Install 4 1⁄2"quick connection at the new hydrant. The gate valve and valve box for hydrant shall be furnished by the Government and installed by the Contractor.i. Repair leak #5: Demolish PVC DN200 main pipe section, T, manhole, lateral pipe to the backflow preventer and water meter. Install main PE100 PN10 DN200 high density polyethylene pipe, electro-welded polyethylene "T", service line to the backflow preventer, gate valve, valve box and water meter. Reinstall above ground gate valve and strainer.j. Repair leak #6: Demolish 10" backflow preventer, water meter and accessories and install PE100 PN10 DN250 high density polyethylene pipe section. Demolish PE DN250 pipe section and install PE100 PN10 DN160 high density polyethylene pipe, 6" galvanized steel pipe, 6" backflow preventer, gate valves, water meter and accessories.k. Repair leak #7: Uncover 1 1⁄2" galvanized steel pipe and replace with new PE100 PN10 DN50 high density polyethylene.l. Repair leak #8: Replace PVC DN200 pipe with PE100 PN10 DN200 high density polyethylene pipe from the exterior of the manhole to the existing gate valve.m. Repair leak #9: Demolish PVC DN250 main pipe section, vertical pipe, air relief valve (to be relocated) and hammer arrestor. Install main PE100 PN10 DN250 high density polyethylene, polyethylene "T" with vertical outlet, DN110 polyethylene vertical pipe and relocate existing air relief valve.n. Repair leak #10: Demolish PVC DN200 main pipe section, vertical pipe and air relief valve (to be relocated). Install main PE100 PN10 DN200 high density polyethylene, polyethylene "T" with vertical outlet, DN110 polyethylene vertical pipe and relocate existing air relief valve.o. Repair leak #11: Replace PVC DN200 pipe with PE100 PN10 DN200 high density polyethylene pipe, replace PVC "T" with 200x200x160 electro-welded polyethylene "T", replace existing lateral pipe with high density polyethylene pipe PE100 PN10 DN160, replace gate valve, valve box and above ground barrel type hydrant. Install 4 1⁄2"quick connection at the new hydrant. The gate valve and valve box for hydrant shall be furnished by the Government and installed by the Contractor.p. Repair leak #12: Demolish PVC DN200 main pipe section, "T", lateral pipe, valve and valve box. Install main PE100 PN10 DN200 high density polyethylene, "T", DN110 polyethylene lateral pipe, valve and valve box.q. Repair leak #13: Replace PVC DN200 pipe section with PE100 PN10 DN200 high density polyethylene pipe.r. Repair leak #14: Replace PVC DN200 pipe with PE100 PN10 DN200 high density polyethylene pipe, replace PVC "T" with 200x200x160 electro-welded polyethylene "T", replace existing lateral pipe with high density polyethylene pipe PE100 PN10 DN160 to the gate valve. Gate valve, valve box and flush type fire hydrant are to remain.s. Repair elements affected by project execution (pavement, topsoil, vegetation, sidewalks, etc.). The finish will be similar to the adjacent finish.t. Perform a leak detection survey to include the new water system installed, as well as the existing pipes that are fed from the new system and supply water to the buildings located inside the areas shown on the drawings as Zones A, B, C, D, E and F.u. GPS topographic study.v. General cleaning of the work site.w. Delivery of As-Built drawings.1.2 Additive item: In case of finding underground obstructions during the pipe excavation, said obstructions shall be demolished and the excavation restored. In order to account for this potential fact an additive item computation has been considered in the project to include the following specific itemsa. Demolish underground concrete block (3 meters deep, 2x2x2 meters) and restore terrain: account for 20 units.b. Supply/install high density polyethylene pipe DN200 mm: account for 150 linear meters.c. Supply/install new underground 8" gate valve and valve box: account for 8 unitsd. Road crossing (15 meters long): account for 10 units.The certification requirements are as follows:CERTIFICATION OF CLASSIFICATION: Bidders and/or their subcontractors must hold an updated Certificate of Classification issued by the "Registro Oficial de Licitadores y Empresas Clasificadas del Estado", covering the following groups, subgroups, and categories. The certificate holder must execute the activities related to the certificate.GROUP SUBGROUP CATEGORYE 1 CIt is highly recommended that you register to be notified of any new postings for this solicitation and/or any other postings published by our office. However, failure of the service to notify you of changes cannot be used against the Government in any way, shape or form. Therefore, you should check FedBizOps, https://www.fbo.gov , frequently for any new postings that may have been made.The Government anticipates and reserves the right, to issue all solicitation documents including specifications and drawings in the English language only.In order to be awarded a contract by the U.S. Government, the company must be registered in the System for Award Management (SAM); contracts cannot be awarded to unregistered contractors. Registration can be made online at www.sam.gov/portal/public/SAM/NOTE: You must have a DUNS number and a NATO Commercial and Government Entity (NCAGE) Code to register. To obtain a Data Universal Numbering System (DUNS) Number you can contact Dun and Bradstreet and request one by calling: 902-446-688. To obtain a NATO CAGE code you must fill out the form found in: http://www.dlis.dla.mil/Forms/Form AC135.asp.Failure to be registered in SAM at the time of award may delay the award and depending on the criticality of the project, may be cause to award to the next qualified best value offeror who is SAM registered. However, do not delay submitting your proposal pending receipt of a DUNS number or CAGE Code.***NOTICE: FUNDING FOR THIS REQUIREMENT IS CURRENTLY NOT AVAILABLE FOR THIS PROJECT. NO AWARD WILL BE MADE UNDER THIS SOLICITATION UNTIL FUNDS ARE AVAILABLE. THE BID ACCEPTANCE PERIOD SHOULD BE VALID THROUGH 30 SEP 2019. THE GOVERNMENT RESERVES THE RIGHT TO CANCEL THIS SOLICITATION.

United StatesLocation

Place Of Performance : Morón AB, Spain

Country : United States

Classification

237 -- Heavy and Civil Engineering Construction/237990 -- Other Heavy and Civil Engineering Construction
naicsCode 237990Other Heavy and Civil Engineering Construction
pscCode ZMAINT, REPAIR, ALTER REAL PROPERTY