H168--Boiler & Chiller Chemical Water Treatment Supplies and Services | Base + 4

From: Federal Government(Federal)
36C25724Q0525

Basic Details

started - 16 Apr, 2024 (13 days ago)

Start Date

16 Apr, 2024 (13 days ago)
due - 21 May, 2024 (in 21 days)

Due Date

21 May, 2024 (in 21 days)
Bid Notification

Type

Bid Notification
36C25724Q0525

Identifier

36C25724Q0525
VETERANS AFFAIRS, DEPARTMENT OF

Customer / Agency

VETERANS AFFAIRS, DEPARTMENT OF
[object Object]

SetAside

SDVOSBC(Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14))
unlockUnlock the best of InstantMarkets.

Please Sign In to see more out of InstantMarkets such as history, intelligent business alerts and many more.

Don't have an account yet? Create a free account now.

Boiler/Chiller Plants Chemical Water Treatment Supplies and Services WATER TREATMENT OBJECTIVES: Contractor will provide a complete water treatment program that will protect critical equipment and piping from deterioration due to corrosion and fouling of waterside surfaces while allowing the equipment to operate at optimum efficiency. The water treatment supplier shall furnish effective products, quality service and good communications, all designed to meet the performance expectation outlined in this specification. Places of Performance: Dallas - Energy Center, Dallas VAMC, 4500 S. Lancaster Rd, Dallas, TX 75216 Garland - Boiler Chiller Plant Garland VAMC, 2301 Marie Curie Blvd, TX 75042 Bonham - Bonham VAMC Boiler Chiller Plant, 1209 E 9th St, Bonham, TX 75418 Period of Performance: Base plus 4 option years Base Year: 08/21/2024 08/20/2025 Option Year 1: 08/21/2025 08/20/2026 Option Year 2: 08/21/2026 08/20/2027 Option Year 3: 08/21/2027 08/20/2028 Option Year 4: 08/21/2028
08/20/2029 CHEMICAL WATER TREATMENT CONTRACTOR QUALIFICATIONS: 1. The contractor shall have been in business at least 10 years providing chemical treatment of boiler/chiller plant and steam and chilled water distribution systems similar in design and annual steam production rates to that of the VA facility. Provide a list of at least five customers similar to VA who have utilized the services for boiler chemical treatment for at least three years. 2. One water treatment specialist who has a bachelor s degree in chemical engineering or the physical sciences from an accredited college or university shall be assigned to this contract. The water treatment specialist must have at least five years successful experience with boiler and chilled water treatment programs and shall furnish references from at least three customers who utilize boiler and chilled water treatment programs. 3. The water treatment specialist/subcontractor assigned to sites must be centrally located in the North Texas metroplex and 50 miles between all three sites to enable reasonable response times to request for site visits. 4. The contractor must operate (or continuously maintain a contract with) a state certified laboratory to perform complete scientific analyses of water chemistry, deposits, metallic materials affected by corrosion and provide recommendations for correction of problems related to the chemical and mechanical water treatment program. See RFQ for more details.

Multiple Locations in TX Bonham, Dallas, Garland See Statement of WorkLocation

Place Of Performance : Multiple Locations in TX Bonham, Dallas, Garland See Statement of Work

Country : United States

You may also like

CHEMICAL WATER TREATMENT (221324-002)

Due: 31 Dec, 2025 (in 20 months)Agency: Erie County

Furnish & Deliver Water and Wastewater Treatment Chemicals

Due: 10 May, 2024 (in 10 days)Agency: City of Fall River

Waste Water Treatment & Ultra Pure Water Chemicals

Due: 31 May, 2024 (in 1 month)Agency: Research Foundation of the State University of New York

Please Sign In to see more like these.

Don't have an account yet? Create a free account now.

Classification

NAICS CodeCode 221310
Classification CodeCode H168