Roof Replacement

expired opportunity(Expired)
From: Federal Government(Federal)
089495-23-A-0007

Basic Details

started - 27 Oct, 2022 (18 months ago)

Start Date

27 Oct, 2022 (18 months ago)
due - 02 Dec, 2022 (16 months ago)

Due Date

02 Dec, 2022 (16 months ago)
Bid Notification

Type

Bid Notification
089495-23-A-0007

Identifier

089495-23-A-0007
POSTAL SERVICE

Customer / Agency

POSTAL SERVICE (1031)POSTAL SERVICE (1031)SUPPLIES MATERIAL MGMT (974)

Attachments (1)

unlockUnlock the best of InstantMarkets.

Please Sign In to see more out of InstantMarkets such as history, intelligent business alerts and many more.

Don't have an account yet? Create a free account now.

SUMMARY OF ROOF REPLACEMENT WORK – AREAS A, B, C & DA. Provide an alternate price for temporary interior protection under roof Areas A & B. Refer toSection 015617. Unit costs will be used to adjust final amountB. Asbestos laboratory analysis report: Refer to Section 022623 for information relating to thelocation of ACM, if applicable, within project areas. If positive refer to Sections 013543 and028233 for procedures and requirements related to the removal and disposal of non-friableasbestos related to this project.C. Roof removal and substrate preparation: Remove existing roof system down to the structuraldeck, including roof membrane(s), and underlying insulation, underlayments, and additional roofmembranes. Inspect the existing structural deck, and inform the Owner immediately of observeddamage and or deterioration. Temporarily displace rooftop equipment as necessary to completethe specified work. Refer to Section 024100.D. Provide an alternate price for complete refastening of existing structural decks; provide a unitprice for areas of existing structural deck that require refastening. Note that refastening ofperimeter wood blocking is required. Refer to Section 053123 for re-fastening requirements.E. After roof removal and inspection of the existing structural deck and perimeter wood blocking,perform repairs to the structural deck, as determined necessary by the Owner. Refer to Section053123. Replace damaged or deteriorated wood blocking, as determined necessary by theOwner. Refer to Section 061053.F. Provide required wood blocking where indicated on the project drawings. Refer to

Eau Claire ,
 WI  54703  USALocation

Place Of Performance : N/A

Country : United States

You may also like

Pecan Building Warehouse Roof Replacement

Due: 23 Apr, 2024 (in 3 days)Agency: Public Works, Purchasing

33 Marlborough Roof Replacement

Due: 30 Apr, 2024 (in 10 days)Agency: County of Wellington

ROOF REPLACEMENT

Due: 09 May, 2024 (in 19 days)Agency: United Counties of Prescott and Russell

Please Sign In to see more like these.

Don't have an account yet? Create a free account now.

Classification

naicsCode 238160Roofing Contractors