**This is not a Small Business Set Aside**References:U. S. Coast Guard Coatings and Color Manual, COMDTINST M10360.3D (January 2014)U. S. Coast Guard Surface Forces Logistics Center Standard Specification 6310 (2020), Requirements for Preservation of Ship StructuresRequirements:Provide authorized coating systems per SFLC Std Spec 6310, Appendix C, which meet the requirements of Table 1 below. For each system, assume a 30% loss. For systems which require stripe coat(s), assume that that 20% of the volume required for a full coat is required for a stripe coat. Colors for primer and intermediate coats must be in accordance with CIM 10360.3D. All multi-coat systems, including stripe coats, must be in contrasting colors for application.Table 1 – List of Coating Systems, Coverage, & Topcoat ColorSystem per SFLC Std Spec 6310, Appendix ACoverage (Sq. Ft.) Description of Paint:1. Smoke Stack (Smoke Stack Casing, Steel Exterior) (Stack Preservation)6,000White 179252. Smoke Stack (Smoke Stack Casing, Steel Exterior) (Stack Preservation)2,000Black 37038Proposal Submission Requirements:For each system, identify for each coat, and include calculations as applicable:- Manufacturer- Product- National Stock Number or Part Number, as applicable- Color- Volume Solids- Dry Film Thickness- Theoretical Coverage (Sq. Ft./Gal)- Practical Coverage (Sq. Ft./Gal) – apply loss assumption here- Coat Gallons- Stripe Coat Gallons – apply stripe coat assumption here, if stripe coat is required- Total Gallons (Coat + Stripe Coat)- Number of Product KitsSee the Appendix for an example presentation of the above information.For each product, submit a Product Data Sheet.Delivery Requirements:Include delivery to Honolulu, HI by 15 February