Preclinical PET/CT for imaging of Rabbits and Non-Human Primates

expired opportunity(Expired)
From: Federal Government(Federal)
SS-RML-C-1889463

Basic Details

started - 01 Feb, 2018 (about 6 years ago)

Start Date

01 Feb, 2018 (about 6 years ago)
due - 09 Feb, 2018 (about 6 years ago)

Due Date

09 Feb, 2018 (about 6 years ago)
Bid Notification

Type

Bid Notification
SS-RML-C-1889463

Identifier

SS-RML-C-1889463
Department of Health and Human Services

Customer / Agency

Department of Health and Human Services
unlockUnlock the best of InstantMarkets.

Please Sign In to see more out of InstantMarkets such as history, intelligent business alerts and many more.

Don't have an account yet? Create a free account now.

IntroductionThis is a Sources Sought notice. This is NOT a solicitation for proposals, proposal abstracts, or quotations. The purpose of this notice is to obtain information regarding the availability and capability of all qualified sources to perform a potential requirement.Background, Purpose, ObjectivesThe National Institute of Allergy and Infectious Diseases (NIAID) is currently seeking sources that have the capability to provide a Positron Emission Tomography (PET) coupled with High-Resolution Computed Tomography (HR-CT) or PET/CT for imaging 0.3-.05 kg marmosets, 3-5 kg rabbits, and 4 to 9 kg Rhesus or Cynomolgus macaques. This equipment will expand the capacity of the Institute to image animals for multiple NIAID investigators. The PET/CT imaging equipment will be located in a Biosafety Level 3 (BSL-3) animal facility and must have sufficient resolution and speed to image 0.2 mm anatomic structures in animals as big as Rhesus macaques and adult New Zealand White (NZW) rabbits.
The new scanner must fit within the animal room allotted for imaging (4' x 6' ft2) along with the other required equipment for caring for the animals during the procedure.Project RequirementsThe PET/CT system must meet, at a minimum, the following technical requirements:1. Due to size limitations where this equipment will be housed, the maximum footprint for the PET/CT system is 6' x 6' x 6'2. Internal X-ray shielding such that the operator may be within the room3. The PET and CT subsystems must be co-registered by both hardware and software design (within one machine unit) with a common animal support4. Active product with at least 10 years of planned maintenance/parts support5. Large bore size (~25cm) witha. Transaxial Field of View (TFOV) 16 to 20 cm,b. Axial Field of View (AFOV) ~ 15 cm per bed,c. Multiple bed acquisition protocols programmable to acquire whole body images of medium size animals (rabbit, rhesus NHP)d. The integrated and physically co-registered CT must have the same TFOV and AFOV as the PET6. PET capable of 1 mm resolution7. CT capable of 0.2 mm resolution8. Segmented CT is used for attenuation and scatter correction of PET signal9. Automated movements for both CT and PET subsystem beds using scout view CT planning image10. Beds offered for various animal types: rhesus monkey, rabbit, marmoset, rat, mouse11. Beds for rabbits and smaller animals are integrated with the temperature control (heating support), anesthesia delivery and vital monitoring systems12. Prospective gating for respiratory and cardiac cycles - programmable with triggering by included animal vital monitoring system13. US based support and serviceThe Government anticipates making a single award, Firm Fixed Price (FFP) purchase order.Anticipated Period of PerformanceIt is anticipated that an award will be made on or about April 1, 2018. Completion of services will be expected no later than July 30, 2018.Capability Statement/Information SoughtIf your organization has the potential capacity to provide this PET/CT imaging system, please provide the following information:1. Organization name, address, point of contact, email address, website address, telephone number, DUNS number2. Size and type of ownership for the organization3. Tailored capability statement addressing the system requirements4. Are you the manufacturer of the PET/CT system?5. Are you an authorized distributor/reseller of the PET/CT system?6. What is the manufacturing country of origin of the PET/CT system?If significant subcontracting or teaming is anticipated in order to deliver technical capability, organizations should address the administrative and management structure of such arrangements.Capability document shall be no more than 6 pages.Submission InstructionsInterested businesses who consider themselves qualified to provide the above listed PET/CT system are invited to submit a response to this Sources Sought Notice by February 9, 2018 at 5:00 PM EST. All responses under this Sources Sought Notice shall be emailed to Tamara McDermott tamara.mcdermott@nih.gov.Disclamer and Important NotesThis notice does not obligate the Government to award a contract or otherwise pay for the information provided in response. The Government reserves the right to use information provided by respondents for any purpose deemed necessary and legally appropriate. Any organization responding to this notice should ensure that its response is complete and sufficiently detailed to allow the Government to determine the organization's qualifications to perform the work. Respondents are advised that the Government is under no obligation to acknowledge receipt of the information received or provide feedback to respondents with respect to any information submitted. After a review of the responses received, a pre-solicitation synopsis and solicitation may be published in Federal Business Opportunities. However, responses to this notice will not be considered adequate responses to a solicitation.ConfidentialityNo proprietary, classified, confidential, or sensitive information should be included in your response. The Government reserves the right to use any non-proprietary technical information in any resultant solicitation(s). 

C.W. Bill Young Center 33 North Drive Building 33 Bethesda, Maryland 20892 United StatesLocation

Place Of Performance : C.W. Bill Young Center 33 North Drive Building 33

Country : United States

Classification

334 -- Computer and Electronic Product Manufacturing/334510 -- Electromedical and Electrotherapeutic Apparatus Manufacturing
naicsCode 334510Electromedical and Electrotherapeutic Apparatus Manufacturing
pscCode 65MEDICAL/DENTAL/VETERINARY EQPT/SUPP