OGS Group 71007 RFP 2544 Building 17 Power Plant Equipment Maintenance, Testing, and Repair RFP 2544 Addendum 3 Attachment 1 Automated Logic System Details OGS Group 71007 RFP 2544 Building 17 Power Plant Equipment Maintenance, Testing, and Repair RFP 2544 Addendum 3 Attachment 1a Automated Logic As Built NYPA OGS Harriman Campus Central Plant State Campus Road Albany, NY 12203 As Prepared By: 23 Village Lane ALC NE Wallingford T: 203-284-0100 PROJECT TEAM F: Wallingford, CT 06492 Client Name: Postler & Jaeckle Corp.Client Name: Postler & Jaeckle Corp. Consulting Engineer: WendelConsulting Engineer: Wendel ALC Design Engineer: Doug LookALC Design Engineer: Doug Look ALC Project Manager: Christina LudwinALC Project Manager: Christina Ludwin Project Number: CT-11-18-0343-PProject Number: CT-11-18-0343-P Drawing Designation: As-BuiltDrawing Designation: As-Built Drawing Date: 11/16/2021Drawing Date: 11/16/2021 Client Name: Postler & Jaeckle Corp. Consulting Engineer: Wendel ALC Design
Engineer: Doug Look ALC Project Manager: Christina Ludwin Project Number: CT-11-18-0343-P Drawing Designation: As-Built Drawing Date: 11/16/2021 DRAWING NO.: SYM.1 TAG DESCRIPTIONS AA Remote Annunciator Module & Auto Dialer P Pressure Probe ALC Automated Logic Controller PDS Pressure Differential Switch ASA Smoke Detector PDT Pressure Differential Transmitter CR Control Relay PS Pressure Switch ENC Enclosure PT Pressure Transmitter ES Direct Current Power Supply QT Gas Transmitter FCV Flow Control Valve / Damper Actuator ST Speed Transmitter FE Flow Element SUB Subpanel FS Flow Switch TE Temperature Element FT Flow Transmitter TS Temperature Switch G Generic Device TSH Temperature Switch High IP Electro-Pneumatic Transducer TSL Temperature Switch Low IS Current Switch TT Temperature Transmitter ISE Circuit Breaker TY Dew Pt./Enthaply/Wet Bulb Transducer IT Current Transducer V Valve JT BTU Meter VT Vibration Transmitter / Switch JY Power Meter X Unclassified KS Electronic Timeclock XF Transformer LS Level Switch YKS Position Transmitter LT Level Transmitter YL Position Transmitter MS Humidistat YS Leak Detector MT Humidity Transmitter YSE Emergency Stop MTE Humidity Transmitter w/ Temperature Element YY Transducer MTT Humidity Transmitter w/ Temperature Transmitter ZS Position Indicating Switch N Accessories ZT Position Transmitter NY Network Device TE-# Field Mounted Instrument LEGEND Pneumatic Tubing Line Voltage Wire Misce llaneous Notations FLP = Fails At Last Position FC = Fails Closed FO = Fails Open LL High Voltage Terminal T1T1 Low Voltage Terminal Wire Color Shield Pigtail Cable Master to Controller Cable Number and Locat ion of Other End Shield Cable Slave to Field Device Low Voltage ConnectionX1 Modbus 120 Ohm End of Line Resistor, 1/4 Watt, +/- 1% BACNet MS/TP Plug-In EOL Terminator & Bias Amplifier for ARC156 Network Ethernet (Cat 6 RJ45 Cable) ARC156 Fiber Optic Cable 120 Ώ BT485 TE-# Field Mounted Instrument LEGEND Pneumatic Tubing Line Voltage Wire Misce llaneous Notations FLP = Fails At Last Position FC = Fails Closed FO = Fails Open L High Voltage Terminal T1 Low Voltage Terminal Wire Color Shield Pigtail Cable Master to Controller Cable Number and Locat ion of Other End Shield Cable Slave to Field Device Low Voltage ConnectionX1 Modbus 120 Ohm End of Line Resistor, 1/4 Watt, +/- 1% BACNet MS/TP Plug-In EOL Terminator & Bias Amplifier for ARC156 Network Ethernet (Cat 6 RJ45 Cable) ARC156 Fiber Optic Cable 120 Ώ BT485 LEGEND W H T B L K (1.0,B1)(1.0,B1)C-2 W H T B L K (1.0,B1)C-2 WHT BLK (1.0,C1)(1.0,C1)C-2 WHT BLK (1.0,C1)C-2 DRAWING NO.: WIRE.1 2 PAIR - 2 CONDUCTOR SHIELDED - RNET Windy City Wire Part Number 160100-S 160100-30S Cable Specifications Jacket Color: White Yellow Description: 18 AWG 2 Pair Bare Copper, Individually Shielded Plenum, UL Subject 444, Type CMP, C(UL) or FPLP UL Conductor Description: 18 (7/26 Bare Copper) Insulation: Low-Smoke PVC .008" Color Code: Black/Red & White/Green Shield: Each Pair Aluminum Polyester Foil - 100% Coverage Drain Wire: 24 AWG 7 Strand Tinned Copper Jacket: Low-Smoke PVC .018" Marking: Temperature Control System, 22 AWG CMP (UL) C(UL). Overall Diameter: .195" Nom Capacitance: 68 pF/ft. Temperature and Voltage Rating: 75 C / 300Volt Cable Weight: 35 Lbs/Mft. Agency Approvals: NEC Article 800; 725, UL CMP, C(UL) or FPLP UL Approved For Plenum Use Without Conduit Per NFPA 262 Flame Test ARC156 / MSTP/ MODBUS COMMUNICATIONS CABLE Windy City Part Number 043006AL-S Description 1 Pair, 22 AWG Tinned Copper Shielded RS-232, RS-422 Low- Capacitance Communication, Instrumentation and Special Application Plenum Cable Conductor Description 22 AWG (7/30) Tinned Copper Insulation FEP .020" Color Code Black/White Shield Aluminum Mylar Foil Drain Wire 24 AWG Stranded Tinned Copper Jacket Low-Smoke PVC .018" Marking ARC156 A B C D E 0 1 2 3 4 5 6 7 8 9 LO-CAP 12.5 PF/FT CL3P OR CMP 22 AWG 75 C. (UL) Overall Diameter .174" Nom. Conductor DCR 18.1 Ohms/Mft. Capacitance 12.5 pF/ft. Nom. Impedance 100 Ohms Nom. Velocity of Propagation N/A Temperature and Voltage Rating 75 C / 300 Volt Cable Weight 18 Lbs/Mft. Agency Approvals: UL Subject 444 and NEC Article 800 Type CMP or FPLP Communication Cable. Approved For Plenum Use Without Conduit Per NFPA 262 Flame Test ALL SPECIFIED CABLE IS AVAILABLE FROM: Windy City Wire Inc. 4250 Madison Street Hillside, Illinois 60162 Phone: 800-379-1191 Fax: 708-493-1380 Web: windycitywire.com SUBSTITUTIONS MUST BE APPROVED EQUAL CABLE SPECIFICATIONS 2 CONDUCTOR SHIELDED - I/O Points Windy City Wire Part Number 0023250-S 002320-S Cable Specifications Jacket Color: Purple White Description: 18 AWG 2 Conductor Bare Copper Shielded Plenum, UL Subject 444, Type CMP, C(UL) or FPLP UL Conductor Description: 18 (7/26 Bare Copper) Insulation: Low-Smoke PVC .008" Color Code: Black/White Shield: Overall Aluminum Polyester Foil - 100% Coverage Drain Wire: 24 AWG 7 Strand Tinned Copper Jacket: Low-Smoke PVC .018" Marking: Temperature Control System, 18 AWG CMP (UL) C(UL). Overall Diameter: .158" Nom. Conductor DCR: 6.66 Ohms/Mft. Capacitance: 68 pF/ft Impedance: 28 Ohms/Mft. Temperature and Voltage Rating: 75 C / 300Volt Cable Weight: 21 Lbs/Mft. Agency Approvals: NEC Article 800; 725, UL CMP, C(UL) or FPLP UL Approved For Plenum Use Without Conduit Per NFPA 262 Flame Test ETHERNET - CAT 6 Windy City Wire Part Number 556600S CABLE SPECIFICATIONS Description: 23 AWG Category 6 Unshielded Twisted Pair (UTP) Cable For Data Transmissions up to 250MHz. This Cable is Plenum Rated and Verifed to Category 6 Electricals. Conductor Description: 23 AWG Solid Bare Copper Insulation: FEP Color Code: White-Blue/Blue, White-Orange/Orange, White- Green/Green, White-Brown/Brown Jacket: Low Smoke PVC Marking: A B C D E 0 1 2 3 4 5 6 7 8 9 (F) CMP (UL) C(UL) 4PR 23 AWG - - ETL VERIFIED TO TIA/EAI-568.B.2-1 UPT CAT 6 Max. Conductor DCR 9.38 Ohms/100m(328 ft) @ 20C Max. Max. Mutual Capacitance 5.6 nF/100m (328 ft) @ 1 kHx Nom. Characteristic Impedance 100 + 15 Ohms (1-250 MHz) Velocity of Propagation 72% Nom. Voltage 300 Volts Flame Rating: Approved For Plenum Use Without Conduit Per NFPA 262 Flame Test Agency Approvals: UL Listed Type CMP, C(UL) 3 CONDUCTOR SHIELDED - I/O Points Windy City Wire Part Number 0023350-S 002330-S Cable Specifications Jacket Color: Purple White Description: 18 AWG 3 Conductor Bare Copper, Shielded Plenum, UL Subject 444, Type CMP, C(UL) or FPLP UL Conductor Description: 18 (7/26 Bare Copper) Insulation: Low-Smoke PVC .008" Color Code: Black/White/Red Shield: Overall Aluminum Polyester Foil - 100% Coverage Drain Wire: 24 AWG 7 Strand Tinned Copper Jacket: Low-Smoke PVC .018" Marking: Temperature Control System, 18 AWG CMP (UL) C(UL). Overall Diameter: .168" Nom. Conductor DCR: 6.66 Ohms/Mft. Capacitance: 68 pF/ft Nom. Impedance: 28 Ohms/Mft. Temperature and Voltage Rating: 75 C / 300Volt Cable Weight: 26 Lbs/Mft. Agency Approvals: NEC Article 800; 725, UL CMP, C(UL) or FPLP UL Approved For Plenum Use Without Conduit Per NFPA 262 Flame Test 2 PAIR - 2 CONDUCTOR SHIELDED - RNET Windy City Wire Part Number 160100-S 160100-30S Cable Specifications Jacket Color: White Yellow Description: 18 AWG 2 Pair Bare Copper, Individually Shielded Plenum, UL Subject 444, Type CMP, C(UL) or FPLP UL Conductor Description: 18 (7/26 Bare Copper) Insulation: Low-Smoke PVC .008" Color Code: Black/Red & White/Green Shield: Each Pair Aluminum Polyester Foil - 100% Coverage Drain Wire: 24 AWG 7 Strand Tinned Copper Jacket: Low-Smoke PVC .018" Marking: Temperature Control System, 22 AWG CMP (UL) C(UL). Overall Diameter: .195" Nom Capacitance: 68 pF/ft. Temperature and Voltage Rating: 75 C / 300Volt Cable Weight: 35 Lbs/Mft. Agency Approvals: NEC Article 800; 725, UL CMP, C(UL) or FPLP UL Approved For Plenum Use Without Conduit Per NFPA 262 Flame Test ARC156 / MSTP/ MODBUS COMMUNICATIONS CABLE Windy City Part Number 043006AL-S Description 1 Pair, 22 AWG Tinned Copper Shielded RS-232, RS-422 Low- Capacitance Communication, Instrumentation and Special Application Plenum Cable Conductor Description 22 AWG (7/30) Tinned Copper Insulation FEP .020" Color Code Black/White Shield Aluminum Mylar Foil Drain Wire 24 AWG Stranded Tinned Copper Jacket Low-Smoke PVC .018" Marking ARC156 A B C D E 0 1 2 3 4 5 6 7 8 9 LO-CAP 12.5 PF/FT CL3P OR CMP 22 AWG 75 C. (UL) Overall Diameter .174" Nom. Conductor DCR 18.1 Ohms/Mft. Capacitance 12.5 pF/ft. Nom. Impedance 100 Ohms Nom. Velocity of Propagation N/A Temperature and Voltage Rating 75 C / 300 Volt Cable Weight 18 Lbs/Mft. Agency Approvals: UL Subject 444 and NEC Article 800 Type CMP or FPLP Communication Cable. Approved For Plenum Use Without Conduit Per NFPA 262 Flame Test ALL SPECIFIED CABLE IS AVAILABLE FROM: Windy City Wire Inc. 4250 Madison Street Hillside, Illinois 60162 Phone: 800-379-1191 Fax: 708-493-1380 Web: windycitywire.com SUBSTITUTIONS MUST BE APPROVED EQUAL CABLE SPECIFICATIONS 2 CONDUCTOR SHIELDED - I/O Points Windy City Wire Part Number 0023250-S 002320-S Cable Specifications Jacket Color: Purple White Description: 18 AWG 2 Conductor Bare Copper Shielded Plenum, UL Subject 444, Type CMP, C(UL) or FPLP UL Conductor Description: 18 (7/26 Bare Copper) Insulation: Low-Smoke PVC .008" Color Code: Black/White Shield: Overall Aluminum Polyester Foil - 100% Coverage Drain Wire: 24 AWG 7 Strand Tinned Copper Jacket: Low-Smoke PVC .018" Marking: Temperature Control System, 18 AWG CMP (UL) C(UL). Overall Diameter: .158" Nom. Conductor DCR: 6.66 Ohms/Mft. Capacitance: 68 pF/ft Impedance: 28 Ohms/Mft. Temperature and Voltage Rating: 75 C / 300Volt Cable Weight: 21 Lbs/Mft. Agency Approvals: NEC Article 800; 725, UL CMP, C(UL) or FPLP UL Approved For Plenum Use Without Conduit Per NFPA 262 Flame Test ETHERNET - CAT 6 Windy City Wire Part Number 556600S CABLE SPECIFICATIONS Description: 23 AWG Category 6 Unshielded Twisted Pair (UTP) Cable For Data Transmissions up to 250MHz. This Cable is Plenum Rated and Verifed to Category 6 Electricals. Conductor Description: 23 AWG Solid Bare Copper Insulation: FEP Color Code: White-Blue/Blue, White-Orange/Orange, White- Green/Green, White-Brown/Brown Jacket: Low Smoke PVC Marking: A B C D E 0 1 2 3 4 5 6 7 8 9 (F) CMP (UL) C(UL) 4PR 23 AWG - - ETL VERIFIED TO TIA/EAI-568.B.2-1 UPT CAT 6 Max. Conductor DCR 9.38 Ohms/100m(328 ft) @ 20C Max. Max. Mutual Capacitance 5.6 nF/100m (328 ft) @ 1 kHx Nom. Characteristic Impedance 100 + 15 Ohms (1-250 MHz) Velocity of Propagation 72% Nom. Voltage 300 Volts Flame Rating: Approved For Plenum Use Without Conduit Per NFPA 262 Flame Test Agency Approvals: UL Listed Type CMP, C(UL) 3 CONDUCTOR SHIELDED - I/O Points Windy City Wire Part Number 0023350-S 002330-S Cable Specifications Jacket Color: Purple White Description: 18 AWG 3 Conductor Bare Copper, Shielded Plenum, UL Subject 444, Type CMP, C(UL) or FPLP UL Conductor Description: 18 (7/26 Bare Copper) Insulation: Low-Smoke PVC .008" Color Code: Black/White/Red Shield: Overall Aluminum Polyester Foil - 100% Coverage Drain Wire: 24 AWG 7 Strand Tinned Copper Jacket: Low-Smoke PVC .018" Marking: Temperature Control System, 18 AWG CMP (UL) C(UL). Overall Diameter: .168" Nom. Conductor DCR: 6.66 Ohms/Mft. Capacitance: 68 pF/ft Nom. Impedance: 28 Ohms/Mft. Temperature and Voltage Rating: 75 C / 300Volt Cable Weight: 26 Lbs/Mft. Agency Approvals: NEC Article 800; 725, UL CMP, C(UL) or FPLP UL Approved For Plenum Use Without Conduit Per NFPA 262 Flame Test DRAWING NO.: TOC.1 DRAWING# DRAWING NAMEDRAWING# DRAWING NAME SYM.1 Symbol LegendSYM.1 Symbol Legend WIRE.1 Wire SpecificationWIRE.1 Wire Specification TOC.1 Table of ContentsTOC.1 Table of Contents Rev.1 Revision HistoryRev.1 Revision History 1.1 ALC Network Riser Diagram1.1 ALC Network Riser Diagram 2.1 Chilled Water Flow Diagram2.1 Chilled Water Flow Diagram 2.2 Chilled Water Pump and Flow Meter Wiring Diagram2.2 Chilled Water Pump and Flow Meter Wiring Diagram 2.3 Condenser Water Flow Diagram2.3 Condenser Water Flow Diagram 2.4 Condenser Water Pump2.4 Condenser Water Pump 2.5a Existing Chiller CH-2 Wiring Details2.5a Existing Chiller CH-2 Wiring Details 2.5b Existing Chiller CH-3 Wiring Details2.5b Existing Chiller CH-3 Wiring Details 2.6 2000 Ton WCH-1 Wiring Details2.6 2000 Ton WCH-1 Wiring Details 2.7 2000 Ton WCH-4 Wiring Details2.7 2000 Ton WCH-4 Wiring Details 2.8 3000 Ton WCH-5 Wiring Details2.8 3000 Ton WCH-5 Wiring Details 2.9 3000 Ton WCH-6 Wiring Details2.9 3000 Ton WCH-6 Wiring Details 2.10 Chilled Water System Control Panel (CP-2)2.10 Chilled Water System Control Panel (CP-2) 2.11 Chilled Water System Control Panel (CP-2) cont'd2.11 Chilled Water System Control Panel (CP-2) cont'd 2.12 Chilled Water System Control Panel (CP-3a)2.12 Chilled Water System Control Panel (CP-3a) 2.13 Chilled Water System Control Panel (CP-3b) cont'd2.13 Chilled Water System Control Panel (CP-3b) cont'd 2.14 Chilled Water Plant Sequence of Operations (1/3)2.14 Chilled Water Plant Sequence of Operations (1/3) 2.15 Chilled Water Plant Sequence of Operations (2/3)2.15 Chilled Water Plant Sequence of Operations (2/3) 2.16 Chilled Water Plant Sequence of Operations (3/3)2.16 Chilled Water Plant Sequence of Operations (3/3) 2.17 Cooling Tower Wiring Details (CT-1 thru CT-3)2.17 Cooling Tower Wiring Details (CT-1 thru CT-3) 2.18 Cooling Tower Wiring Details (CT-4 & CT-5)2.18 Cooling Tower Wiring Details (CT-4 & CT-5) 2.18.1 Cooling Tower Fan VFD Wiring Details2.18.1 Cooling Tower Fan VFD Wiring Details 2.19 Condenser Water System Control Panel (CP-4)2.19 Condenser Water System Control Panel (CP-4) 2.20 Condenser Water System Control Panel (CP-5)2.20 Condenser Water System Control Panel (CP-5) 2.20.1 CT Flow Metering Network Control Panel (CP-6)2.20.1 CT Flow Metering Network Control Panel (CP-6) 2.21 CW System Sequence of Operations2.21 CW System Sequence of Operations 2.22 Integration Points Lists - Energy Meters and Pump Controller2.22 Integration Points Lists - Energy Meters and Pump Controller DRAWING# DRAWING NAMEDRAWING# DRAWING NAME 2.23 Secondary Chilled Water Pump Wiring Details2.23 Secondary Chilled Water Pump Wiring Details 2.24 Secondary Chilled Water Pump Control Panel (CP-7)2.24 Secondary Chilled Water Pump Control Panel (CP-7) 2.25 Secondary Chilled Water Pump Sequence of Operations2.25 Secondary Chilled Water Pump Sequence of Operations 3.1 Break Glass Switch Refrigerant Monitoring System Wiring3.1 Break Glass Switch Refrigerant Monitoring System Wiring 3.2 Refrigerant Purge Exhaust Fan EF-2 Control3.2 Refrigerant Purge Exhaust Fan EF-2 Control 3.3 Chemical Storage Room Exhaust Fan EF-3 Control3.3 Chemical Storage Room Exhaust Fan EF-3 Control 3.4 Control Panel CP-13.4 Control Panel CP-1 3.5 Control Panel CP-1 (cont'd)3.5 Control Panel CP-1 (cont'd) 4.1 Typical Boiler Integration BACnet Points List4.1 Typical Boiler Integration BACnet Points List 4.2 Boiler Feedwater Integration BACnet Points List4.2 Boiler Feedwater Integration BACnet Points List 4.3 Boiler Plant Master Integration BACnet Points List4.3 Boiler Plant Master Integration BACnet Points List 7.1 Valve Schedule7.1 Valve Schedule 7.2 Energy/Flow Meter Schedule7.2 Energy/Flow Meter Schedule 0 0 0 0 0 DRAWING NAME: Revision History PROJECT: NYPA OGS Harriman Campus Central Plant State Campus Road Albany, NY 12203 CONTRACT NO: CT-11-18-0343-P REV DESCRIPTION DATE BY FILENAME: 00 Revision History DE: DL Revision History SE:ST/CH23 Village Lane Wallingford, CT 06492 A B C D E F G H 1 2 3 4 5 1 2 3 4 5 PR: DRAWING NO.: Rev.1 Drawing # Drawing Name Su b m it ta l (1 /1 8 /1 9 ) R ev is io n .1 (2 /7 /1 9 ) R ev is io n .2 (2 /1 3 /1 9 ) R ev is io n .3 (2 /1 5 /1 9 ) R ev is io n .4 (3 /7 /1 9 ) R ev is io n .5 (3 /2 7 /1 9 ) R ev is io n .6 (8 /2 6 /1 9 ) R ev is io n .7 (9 /9 /2 0 ) R ev is io n .8 (1 0 /3 0 /2 0 ) R ev is io n .9 (2 /9 /2 1 ) R ev is io n .1 0 (1 1 .1 6 .2 1 ) REVISION 1.1 ALC Network Riser Diagram X X X X CP-3 broken into CP-3a/CP-3b (rev.2), As-built (Rev.7), CO#6 (rev.8) 2.1 Chilled Water Flow Diagram X X X X X Added OA temp/humidity sensor (rev.3), Filter pump control added (rev.6), As-built (Rev.7), CO#6 (rev.8) 2.2 Chilled Water Pump and Flow Meter Wiring Diagram X X As-built (Rev.7) 2.3 Condenser Water Flow Diagram X X X X X Filter pump control added (rev.6), As-built (Rev.7), CO#6 (rev.8), CO#6 resubmittal (rev.9) 2.4 Condenser Water Pump X As-built (Rev.7) 2.5 Existing Chiller Wiring Details X X As-built (Rev.7) 2.6 2000 Ton WCH-1 Wiring Details X X As-built (Rev.7) 2.7 2000 Ton WCH-4 Wiring Details X X As-built (Rev.7) 2.8 3000 Ton WCH-5 Wiring Details X X As-built (Rev.7) 2.9 3000 Ton WCH-6 Wiring Details X X As-built (Rev.7) 2.10 Chilled Water System Control Panel (CP-2) X X X CP Layout detail revised (rev.2), As-built (Rev.7) 2.11 Chilled Water System Control Panel (CP-2) cont'd X X As-built (Rev.7) 2.12 Chilled Water System Control Panel (CP-3a) X X X CP-3 broken into CP-3a/CP-3b (rev.2), As-built (Rev.7) 2.13 Chilled Water System Control Panel (CP-3b) X X X X X CP-3 broken into CP-3a/CP-3b (rev.2), Added OA temp/humidity sensor (rev.3), Filter pump points added (rev.6), As-built (Rev.7) 2.14 Chilled Water Plant Sequence of Operations (1/3) X X X Sequence revs per engineers comments (rev.4), As-built (Rev.7) 2.15 Chilled Water Plant Sequence of Operations (2/3) X X X As-built (Rev.7), CO#6 resubmittal (rev.9) 2.16 Chilled Water Plant Sequence of Operations (3/3) X X X X X Filter pump SOO (rev.6), As-built (Rev.7), CO#6 (rev.8), As-built (rev.10) 2.17 Cooling Tower Wiring Details (CT-1 thru CT-3) X X X X X CT valve relay panel added (rev.1), Level Sensors Added (rev.5), As-built (Rev.7), CO#6 (rev.8) 2.18 Cooling Tower Wiring Details (CT-4 & CT-5) X X X X X CT valve relay panel added (rev.1), Level Sensors Added (rev.5), As-built (Rev.7), CO#6 (rev.8) 2.19 Condenser Water System Control Panel (CP-4) X X X X X CP Layout detail revised (rev.2), Level Sensors Added (rev.5), As-built (Rev.7), CO#6 (rev.8) 2.20 Condenser Water System Control Panel (CP-5) X X X X X CP Layout detail revised (rev.2), Level Sensors Added (rev.5), As-built (Rev.7), CO#6 (rev.8) 2.20.1 X 2.21 CW System Sequence of Operations X X X X X X Sequence revs per engineers comments (rev.4), Level Sensors Added (rev.5), As-built (Rev.7), CO#6 resubmittal (rev.9), As-built (rev.10) 2.22 Integration Points Lists - Energy Meters and Pump Controller X X As-built (Rev.7) 2.23 Secondary Chiller Water Pump Wiring Details X X CO#6 (Rev.8), CO#6 resubmittal (rev.9) 2.24 Secondary Chiller Water Pump Control Panel X X CO#6 (Rev.8), CO#6 resubmittal (rev.9) 2.25 Secondary Chilled Water Pump Sequence of Operations X X CO#6 (Rev.8), CO#6 resubmittal (rev.9) 3.1 Break Glass Switch Refrigerant Monitoring System Wiring X 3.2 Refrigerant Purge Exhaust Fan EF-2 Control X X CO#6 resubmittal (rev.9) 3.3 Chemical Storage Room Exhaust Fan EF-3 Control X X CO#6 resubmittal (rev.9) 3.4 Control Panel CP-1 X 3.5 Control Panel CP-1 (cont'd) X X As-built (Rev.7) 4.1 Typical Boiler Integration BACnet Points List X X X As-built - Points List (rev.10) 4.2 Boiler Feedwater Integration BACnet Points List X As-built - Points List (rev.10) 4.3 Boiler Plant Master Integration BACnet Points List X As-built - Points List (rev.10) 7.1 Valve Schedule X X CO#6 (Rev.8) 7.2 Energy/Flow Meter Schedule X X CO#6 (Rev.8) DL DL DL DL1/18/2019 2/13/2019 9/9/2020 10/30/2020 0 CO#6 As-Built Panel Shop Revisions Submittal0 1 2 3 DRAWING NAME: ALC Network Riser Diagram PROJECT: NYPA OGS Harriman Campus Central Plant State Campus Road Albany, NY 12203 CONTRACT NO: CT-11-18-0343-P REV DESCRIPTION DATE BY FILENAME: 01 Riser DE: DL ALC Network Riser Diagram SE:ST/CH23 Village Lane Wallingford, CT 06492 A B C D E F G H 1 2 3 4 5 1 2 3 4 5 PR: MSTP Trunk. 38400 Baud MSTP Trunk. 38400 Baud CP-5 CP-1 CP-3a CP-2 DRAWING NO.: 1.1 Ethernet BACnet Port S 2 Xnet PlantCTRL MAC: 2 IP: 192.168.1 68.2 Dev ID: 240201 MEx816u MAC: 2 MEx816u MAC: 1 MEx816u MAC: 4 MEx816u MAC: 3 Carrier 19XR Series Chiller - 2000 Tons ADD: 1 CH-1 Existing Carrier 19 XR Chiller - 1000 Tons ADD: 2 CH-2 Existing Carrier 19 XR Chiller - 1000 Tons ADD: 3 CH-3 Carrier 19XR Series Chiller - 2000 Tons ADD: 4 CH-4 Carrier 19XR Series Chiller - 3000 Tons ADD: 5 CH-5 Carrier 19XR Series Chiller - 3000 Tons ADD: 6 CH-6 Cable Reference Modbus 120 Ohm End of Line Resistor, 1/4 Watt, +/- 1% BACNet MS/TP Plug-In EOL Terminator & Bias Amplifier for ARC156 Network Ethernet (Cat 6 RJ45 Cable) ARC156 Fiber Optic Cable 120 Ώ BT485 Carrier CCN Cable Reference Modbus 120 Ohm End of Line Resistor, 1/4 Watt, +/- 1% BACNet MS/TP Plug-In EOL Terminator & Bias Amplifier for ARC156 Network Ethernet (Cat 6 RJ45 Cable) ARC156 Fiber Optic Cable 120 Ώ BT485 Carrier CCN Honeywell 301C-1-BIP ADD: Refrigerant Monitoring Panel BACnet/IP Dev ID 2402103 Flexim Flexus 7407 Energy Meter (FT-1) ADD: 103 CH-1 CHW BTU Meter Dev ID 2402104 Flexim Flexus 7407 Energy Meter (FT-2) ADD: 104 CH-1 CW BTU Meter Dev ID 2402105 Flexim Flexus 7407 Energy Meter (FT-3) ADD: 105 CH-4 CHW BTU Meter Dev ID 2402106 Flexim Flexus 7407 Energy Meter (FT-4) ADD: 106 CH-4 CW BTU Meter Dev ID 2402107 Flexim Flexus 7407 Energy Meter (FT-5) ADD: 107 CH-5 CHW BTU Meter Dev ID 2402108 Flexim Flexus 7407 Energy Meter (FT-6) ADD: 108 CH-5 CW BTU Meter Dev ID 2402109 Flexim Flexus 7407 Energy Meter (FT-7) ADD: 109 CH-6 CHW BTU Meter Dev ID 2402110 Flexim Flexus 7407 Energy Meter (FT-8) ADD: 110 CH-6 CW BTU Meter BACnet/IP CP-4 MEx816u MAC: 2 MEx816u MAC: 1 MEx816u MAC: 3 CMnet BACnet Xnet ME812u MAC: 13 Condenser Water/ CT Controller Dev ID: 240113 Dev ID: 52001 VFD ADD: 1 CT-1 Fan VFD Dev ID: 52002 VFD ADD: 2 CT-2 Fan VFD Dev ID: 52003 VFD ADD: 3 CT-3 Fan VFD Dev ID: 52004 VFD ADD: 4 CT-4 Fan VFD Dev ID: 52005 VFD ADD: 5 CT-5 Fan VFD Ethernet ARC156 Port S 2 Port S 1 LGR1000 MAC: 1 IP: 192.168.1 68.1 Dev ID: 240101 ALC- 1 ALC- 2 ALC- 3 ALC- 4 Dev ID 2402101 Armstrong Parallel Pump Controller ADD: 101 CW Pumps PC-1 to PC-5 Dev ID 2402102 Armstrong Parallel Pump Controller ADD: 102 CHW Pump PP-1 to PP-5 Operators Workstation Operators Workstation Located in Office 100 G-1 G-2 Servers to be rack mounted in Server Room 102 G-3G-4 G-5 1 10 -2 40 V A CG n d N L Ethernet Switch 12345678 17181920 9101112 1314151621222324 NY-1 Connection to Customer Network (by others) Laptop ComputerLaptop Computer Redundant connection to Customer Network (by others) Ethernet Switch to be rack mounted in Server Room 102. Tag Part Number Product Description Manufacturer Quantity G-1 R640 Dell PowerEdge R640 Rack Server Dell 1 G-2 R640 Dell PowerEdge R640 Rack Server Dell 1 G-3 OptiPlex 7050 MT Desktop WebCTRL Server Dell 1 G-4 P2417H 24-inch monitor Dell 1 G-5 Latitude 3580 Intel Core i3-6006U, 15.6-inch non-touch HD Dell 1 ALC-1 WC-Superset WebCTRL Superset Automated Logic 1 ALC-2 WC-ADV_ALARM WebCTRL Superset Automated Logic 1 ALC-3 WC-ADV_REP WebCTRL Superset Automated Logic 1 ALC-4 WC-ADV_SEC WebCTRL Superset Automated Logic 1 NY-1 SG112-24 24 Port 10BASE-T/100BASE-T/1000BASE-T rack mountable switch Cisco 1 Bill of Material w/ Tags SE6104a MAC: 11 EF-2 & EF-3 AMR #3 MAC: 3 BT485 BT485 120 Ώ Dev ID 2402111 Flexim Flexus 7407 Energy Meter (FT-9) ADD: 111 Common Primary CHW Ethernet Switch 12345678 CP-3b MEx816u MAC: 5 MEx48u MAC: 6 IP Address: 192.168.168.222 IP Address: 192.168.168.200 Dev 1 - IP Address: 192.168.168.4, Dev ID: 7000 Redundant Devices Dev 2 - IP Address: 192.168.168.5, Dev ID: 7001 DevID: 24 0103 DevID: 24 0111 IP Address: 192.168.168. 3 Dev ID: 52006 Dev ID 2402114 Flexim Flexus 7407 Energy Meter (FT-13) ADD: 114 CH-3 CW BTU Meter Dev ID 2402115 Flexim Flexus 7407 Energy Meter (FT-12) ADD: 115 CH-3 CHW BTU Meter Dev ID 2402113 Flexim Flexus 7407 Energy Meter (FT-11) ADD: 113 CH-2 CHW Dev ID 2402112 Flexim Flexus 7407 Energy Meter (FT-10) ADD: 112 CH-2 CW CCN Trunk. 9600 Baud Main SCADA Boiler Panel BACnet/IP CP-6 Ethernet Port S 1 Port S 2 G5CE MAC: IP: Flexim Flexus 721 Energy Meter (FT-14) ADD: 2 CT-1 CHS/R Flexim Flexus 721 Energy Meter (FT-15) ADD: 3 CT-2 CHS/R Flexim Flexus 721 Energy Meter (FT-16) ADD: 4 CT-3 CHS/R Flexim Flexus 721 Energy Meter (FT-17) ADD: 5 CT-4 CHS/R Flexim Flexus 721 Energy Meter (FT-18) ADD: 6 CT-5 CHS/R CAT6 cable to nearest ALC network switch. Note which switch and port for as-built documentation CP-7 Ethernet Act N etI/O BusPort S 2Port S 1 OF1628 MAC: IP: Secondary CHW Pumps DL DL DL DL DL1/18/2019 2/7/2019 2/13/2019 3/7/2019 8/26/2019Added CHW & CW Filter Pump Control Sequence revs per engineeers comments Panel Shop Revisions Update - Added Tower Valve Relay Panel Submittal0 1 2 3 4 5 As-Built 9/9/2020 DL 6 CO#6 10/30/2020 DL 7 As-Built 11/16/2021 DL DRAWING NAME: Chilled Water Flow Diagram PROJECT: NYPA OGS Harriman Campus Central Plant State Campus Road Albany, NY 12203 CONTRACT NO: CT-11-18-0343-P REV DESCRIPTION DATE BY FILENAME: 02 CHW System DE: DL Chilled Water Flow Diagram SE:ST/CH23 Village Lane Wallingford, CT 06492 A B C D E F G H 1 2 3 4 5 1 2 3 4 5 PR: 30" 30" 6" 6" 24" 24" 30" 30" 30" 30" 30" 30" 30" 16" 16" 16" 16" 16" 12" 12" 12" 12" 16" DRAWING NO.: 2.1 ...--.-. -..--|-.: ::: |-||--. WCH-5 3000 Tons ...--.-. -..--|-.: ::: |-||--. WCH-5 3000 Tons ...--.-. -..--|-.: ::: |-||--. Ex. Chiller No.3 1000 Tons ...--.-. -..--|-.: ::: |-||--. Ex. Chiller No.3 1000 Tons ...--.-. -..--|-.: ::: |-||--. WCH-1 2000 Tons ...--.-. -..--|-.: ::: |-||--. WCH-1 2000 Tons ...--.-. -..--|-.: ::: |-||--. WCH-6 3000 Tons ...--.-. -..--|-.: ::: |-||--. WCH-6 3000 Tons ...--.-. -..--|-.: ::: |-||--. WCH-4 2000 Tons ...--.-. -..--|-.: ::: |-||--. WCH-4 2000 Tons ...--.-. -..--|-.: ::: |-||--. Ex. Chiller No. 2 1000 Tons ...--.-. -..--|-.: ::: |-||--. Ex. Chiller No. 2 1000 Tons EX. PD-5 PP-5 EX. PD-4 EX. PD-3 EX. PD-2 EX. PD-1 PP-4 PP-3 PP-2 PP-1VFD VFD VFD VFD VFD Existing Chilled Water Filtration 1. Optimal flow meter installation locations to be determined on site based on field conditions. FT-7 FT-7 FT-1 FT-1 FT-5 FT-5 V-WCH-5-CHWS V-ECH-3-CHWS V-WCH-1-CHWS V-ECH-2-CHWS V-WCH-4-CHWS V-WCH-6-CHWS V-WCH-5-CHWR V-WCH-1-CHWR V-WCH-4-CHWRV-WCH-6-CHWR VFD VFD VFD VFD VFD FT-3 FT-3 FT-9FT-9 CHWR from Bldg. No. 18 CHWS to Bldg. No. 18 CHWS to Campus Distribution System CHWR from Campus Distribution System 16" 16" 2-Po s M O D M O D M O D M O D M O D M O D 2-Po s 2-Po s 2-Po s 30" 24" 30" 30" 4000 GPM 4000 GPM 4000 GPM 4000 GPM 4000 GPM 6000 GPM 6000 GPM 6000 GPM 6000 GPM 6000 GPM Max. CHWS Flow = 7187 GPM Max. CHWS Flow = 7187 GPM Max. CHWS Flow = 4791 GPM Max. CHWS Flow = 4791 GPM T T TE -1 T T TE -2 T T TE -3 T T TE-4 T T TE-5 T T TE-6 TT TE-7 T T TE-8 TT TE-10 T T TE-9 WHT BLK (2 .1 1 ,A 1 ) W C H -1 C H W S T em p (2 .1 1 ,A 1 ) W C H -1 C H W S T em p C - 4 5 WHT BLK (2 .1 1 ,A 1 ) W C H -1 C H W S T em p C - 4 5 WHT BLK (2 .1 0, A 1) C H -2 C H W S Te m p (2 .1 0, A 1) C H -2 C H W S Te m p C - 1 WHT BLK (2 .1 0, A 1) C H -2 C H W S Te m p C - 1 WHT BLK (2.10,A3) CH-3 CHWS Temp (2.10,A3) CH-3 CHWS Temp C-21 WHT BLK (2.10,A3) CH-3 CHWS Temp C-21 W H T B LK (2.10,A5) Sec CHWR T (2.10,A5) Sec CHWR T C-36 W H T B LK (2.10,A5) Sec CHWR T C-36 W H T B LK (2.10,A4) PrmryCHWS T (2.10,A4) PrmryCHWS T C-33 W H T B LK (2.10,A4) PrmryCHWS T C-33 WHT BLK(2.10,A5) Primary CHWR T (2.10,A5) Primary CHWR T C-34 WHT BLK(2.10,A5) Primary CHWR T C-34 WHT BLK (2.10,A5)Secondary CHWS T (2.10,A5)Secondary CHWS T C-35 WHT BLK (2.10,A5)Secondary CHWS T C-35 WHT BLK (2.12,A1) WCH-4 CHWS Temp (2.12,A1) WCH-4 CHWS Temp C-69 WHT BLK (2.12,A1) WCH-4 CHWS Temp C-69 WHT BLK (2.12,A3) WCH-5 CHWS Temp (2.12,A3) WCH-5 CHWS Temp C-93 WHT BLK (2.12,A3) WCH-5 CHWS Temp C-93 WHT BLK (2.13,A1) WCH-6 CHWS Temp (2.13,A1) WCH-6 CHWS Temp C-117 WHT BLK (2.13,A1) WCH-6 CHWS Temp C-117 S ig + C om - See Drawing No. 2.6 for WCH-1 valve, flow meter and chiller wiring details See Drawing No. 2.5a for WCH-3 valve, flow meter and chiller wiring details See Drawing No. 2.7 for WCH-4 valve, flow meter and chiller wiring details See Drawing No. 2.8 for WCH-5 valve, flow meter and chiller wiring details See Drawing No. 2.9 for WCH-6 valve, flow meter and chiller wiring details See Drawing No. 2.5b for WCH-2 valve, flow meter and chiller wiring details See Drawing No. 2.2 for flow meter FT-9 wiring details W H T B LK (2.13,A3) OA Temperature (2.13,A3) OA Temperature C-142 W H T B LK (2.13,A3) OA Temperature C-142 W H T B LK (2.13,A3) OA Humidity (2.13,A3) OA Humidity C-143 W H T B LK (2.13,A3) OA Humidity C-143 MTE- 1 V+GND TEV OUT TE Mount temperature sensor in shaded area on north facing wall. IS-1 C NO Wht/Yel 2 4V 1 20 V C O M C N O N C C R -1 Wht/Bl k Wht/Bl u Blu Yel O rg R IB M HAND AUTO OFF L1 L2 MOTOR STARTER M 2 M 1 Power by others M HAND AUTO OFF L1 L2 MOTOR STARTER M 2 M 1 Power by others CHW Filter Pump Wiring Power to filtration pump Tag Part Number Product Description Manufacturer Quantity CR-1 RIBU1C Encl. Relay, 10A,SPDT,24/120 VAC Coils Functional Devices 1 IS-1 H608 Current Switch, Split Core, Adj. Setpoint to 0.5A, Mini Veris 1 PDT-2 2301-050PD-3V-11-B Diff. Press. Transmitter, Wet, 4-20 mA, 0-50 psid Setra 1 MTE-1 NSB-10K-2-H200-O-BB2-A 2%RH Outside Air Temp & Humidity Sensor, Bapi-Box Enclosure Automated Logic 1 TE-1 ALC/10K-2-I-8"-MB Immersion 8" Insertion, J-Box, w/Brass Thermowell BAPI 1 TE-10 ALC/10K-2-I-8"-MB Immersion 8" Insertion, J-Box, w/Brass Thermowell BAPI 1 TE-2 ALC/10K-2-I-8"-MB Immersion 8" Insertion, J-Box, w/Brass Thermowell BAPI 1 TE-3 ALC/10K-2-I-8"-MB Immersion 8" Insertion, J-Box, w/Brass Thermowell BAPI 1 TE-4 ALC/10K-2-I-8"-MB Immersion 8" Insertion, J-Box, w/Brass Thermowell BAPI 1 TE-5 ALC/10K-2-I-8"-MB Immersion 8" Insertion, J-Box, w/Brass Thermowell BAPI 1 TE-6 ALC/10K-2-I-8"-MB Immersion 8" Insertion, J-Box, w/Brass Thermowell BAPI 1 TE-7 ALC/10K-2-I-8"-MB Immersion 8" Insertion, J-Box, w/Brass Thermowell BAPI 1 TE-8 ALC/10K-2-I-8"-MB Immersion 8" Insertion, J-Box, w/Brass Thermowell BAPI 1 TE-9 ALC/10K-2-I-8"-MB Immersion 8" Insertion, J-Box, w/Brass Thermowell BAPI 1 Bill of Material w/ Tags W H T B LK (2.13,A3) CHW Filter Pump Status (2.13,A3) CHW Filter Pump Status C-144 W H T B LK (2.13,A3) CHW Filter Pump Status C-144 WHT BLK (2.13,E5) CHW Filter Pump S/S (2.13,E5) CHW Filter Pump S/S C-146 WHT BLK (2.13,E5) CHW Filter Pump S/S C-146 FT-11FT-11 FT-12FT-12 WHT BLK (2.19,A2) CHW System DP (2.19,A2) CHW System DP C-203 WHT BLK (2.19,A2) CHW System DP C-203 FT-19 FT-19 W H T B LK (2.24,C3) CHW Differential Pressure (2.24,C3) CHW Differential Pressure C-408 W H T B LK (2.24,C3) CHW Differential Pressure C-408 W H T B LK (2 .2 4, C3 ) C H W R et u rn P SI (2 .2 4, C3 ) C H W R et u rn P SI C - 4 0 9 W H T B LK (2 .2 4, C3 ) C H W R et u rn P SI C - 4 0 9 WHT BLK(2.24,C3) CHW Supply PSI (2.24,C3) CHW Supply PSI C-410 WHT BLK(2.24,C3) CHW Supply PSI C-410 Sig + Com - CHW Flow meter, CHW Supply Pressure, CHW Return Pressure and CHW Differential Pressure sensors and associated wiring are existing to remain. Field verify wir ing, range and control signal. R ed B lu Y el P w rC om O ut Red Blu Yel Pwr Com Out DL DL DL DL DL1/18/2019 2/7/2019 2/13/2019 3/7/2019 8/26/2019Added CHW & CW Filter Pump Control Sequence revs per engineeers comments Panel Shop Revisions Update - Added Tower Valve Relay Panel Submittal0 1 2 3 4 5 As-Built 9/9/2020 DL 6 CO#6 10/30/2020 DL 7 As-Built 11/16/2021 DL DRAWING NAME: Chilled Water Pump and Flow Meter Wiring Diagram PROJECT: NYPA OGS Harriman Campus Central Plant State Campus Road Albany, NY 12203 CONTRACT NO: CT-11-18-0343-P REV DESCRIPTION DATE BY FILENAME: 02 CHW System DE: DL Chilled Water Pump and Flow Meter Wiring Diagram SE:ST/CH23 Village Lane Wallingford, CT 06492 A B C D E F G H 1 2 3 4 5 1 2 3 4 5 PR: DRAWING NO.: 2.2 N L G 120 VAC Common Primary CHW Energy Meter (FT-9) Wiring Details T1a T1A T1b T1B T2a T2A T2b T2B S1 S2 N- L+ PE J-Box Note: Cable between J-box and Energy meter shall be shielded 4-wire 18 gauge wire. Jbox with terminal strip provided with meter. (typ.) 20' cable provided with temp transmitter RTD CHW Supply Clamp-on RTD provided with meter. J-Box 20' cable provided with temp transmitter RTD J-Box CHW Return Clamp-on RTD provided with meter. X_AR X_AV Coaxial cable provided with flow transmitter Coaxial cable provided with flow transmitter RS-485 BACnet MSTP Com. Bus IN and OUT As per Riser Diagram Wht Blk Wht Blk Wht Blk G-1 Note: All details are based on manufacturers documentation available at time of design. Verify with manufacturers documentation provided with energy meter. Refer to manufacturers documentation for additional installation details. 33+ 34- IPS 4003 Terminal Block Chilled Water Pump Controller Wiring Chilled Water Pump Wiring 24 VDC DI Signal 35+ 36- 24 VDC DI Signal 37+ 38- 24 VDC DI Signal 39+ 40- 24 VDC DI Signal 41+ 42- 24 VDC DI Signal 43+ 44- 24 VDC DI Signal 45+ 46- 24 VDC DI Signal 47+ 48- 24 VDC DI Signal 49+ 50- 24 VDC DI Signal S/S Speed Run Status Fault Auto Bypass RS-485 BAS Remote Start/Stop Pump 1 VFD Fault Pump 2 VFD Fault Pump 3 VFD Fault Pump 4 VFD Fault Pump 1 VFD Run Feedback Pump 2 VFD Run Feedback Pump 3 VFD Run Feedback Pump 4 VFD Run Feedback 53+ 54- AO Signal 0V Pump 1 VFD Speed Reference (0-10 VDC) 55+ 56- AO Signal 0V 57+ 58- AO Signal 0V 59+ 60- AO Signal 0V Pump 2 VFD Speed Reference (0-10 VDC) Pump 3 VFD Speed Reference (0-10 VDC) Pump 4 VFD Speed Reference (0-10 VDC) G G 61+ 62- NO Com Pump 1 VFD Start Signal 63+ 64- NO Com Pump 2 VFD Start Signal 65+ 66- NO Com Pump 3 VFD Start Signal 67+ 68- NO Com Pump 4 VFD Start Signal 73+ 74- NO Com General System Alarm (Dry Contact) 75+ 76- NO Com Pump 1 VFD Auto Bypass 77+ 78- NO Com 79+ 80- NO Com 81+ 82- NO Com Pump 2 VFD Auto Bypass Pump 3 VFD Auto Bypass Pump 4 VFD Auto Bypass 93 91 92 Rx+/Tx+ Ground BAS Serial Interface Rx-/Tx- 96- 94 95+Rx+/Tx+ Ground Pump Serial I nterface Rx-/Tx- BACnet MSTP Com. Bus IN and OUT As per Riser Diagram Wht Blk Wht Blk Wht Blk Wht Blk Wht Blk Wht Blk Wht Blk Wht Blk Wht Blk Modbus Com. Bus in from Pump Controller, Out to Pump 2 VFD Modbus Com. Bus out to Pump 1 VFD 135+ 136- 24 VDC DI Signal Pump 5 VFD Fault 153+ 154- AO Signal 0V Pump 5 VFD Speed Reference (0-10 VDC) G 161+ 162- NO Com Pump 5 VFD Start Signal 175+ 176- NO Com Pump 5 VFD Auto Bypass PP-1 Terminal Strip S/S Speed Run Status Fault Auto Bypass RS-485 Wht Blk Wht Blk Wht Blk Modbus Com. Bus in from Pump 1 VFD, Out to Pump 3 VFD PP-2 Terminal Strip S/S Speed Run Status Fault Auto Bypass RS-485 Wht Blk Wht Blk Wht Blk Modbus Com. Bus in from Pump 2 VFD, Out to Pump 4 VFD PP-3 Terminal Strip S/S Speed Run Status Fault Auto Bypass RS-485 Wht Blk Wht Blk Wht Blk Modbus Com. Bus in from Pump 3 VFD, Out to Pump 5 VFD PP-4 Terminal Strip S/S Speed Run Status Fault Auto Bypass RS-485 PP-5 Terminal Strip WHT BLK (2.2,E1)(2.2,E1)C-326 WHT BLK (2.2,E1)C-326 WHT BLK (2.2,B1)(2.2,B1) C-326 WHT BLK (2.2,B1) C-326 WHT BLK (2.2,E2)(2.2,E2)C-327 WHT BLK (2.2,E2)C-327 WHT BLK (2.2,B1)(2.2,B1) C-327 WHT BLK (2.2,B1) C-327 WHT BLK (2.2,E3)(2.2,E3)C-328 WHT BLK (2.2,E3)C-328 WHT BLK (2.2,B1)(2.2,B1) C-328 WHT BLK (2.2,B1) C-328 WHT BLK (2.2,E4)(2.2,E4)C-329 WHT BLK (2.2,E4)C-329 WHT BLK (2.2,B1)(2.2,B1) C-329 WHT BLK (2.2,B1) C-329 143+ 144- 24 VDC DI Signal Pump 5 VFD Run Feedback WHT BLK (2.2,E5)(2.2,E5)C-330 WHT BLK (2.2,E5)C-330 WHT BLK (2.2,B4)(2.2,B4) C-330 WHT BLK (2.2,B4) C-330 Wht Blk Wht Blk Wht Blk Modbus Com. Bus in from Pump 4 VFD WHT BLK (2.2,E1)(2.2,E1)C-331 WHT BLK (2.2,E1)C-331 WHT BLK (2.2,B2)(2.2,B2) C-331 WHT BLK (2.2,B2) C-331 WHT BLK (2.2,E2)(2.2,E2)C-332 WHT BLK (2.2,E2)C-332 WHT BLK (2.2,B2)(2.2,B2) C-332 WHT BLK (2.2,B2) C-332 WHT BLK (2.2,E3)(2.2,E3)C-333 WHT BLK (2.2,E3)C-333 WHT BLK (2.2,B2)(2.2,B2) C-333 WHT BLK (2.2,B2) C-333 WHT BLK (2.2,E4)(2.2,E4)C-334 WHT BLK (2.2,E4)C-334 WHT BLK (2.2,B2)(2.2,B2) C-334 WHT BLK (2.2,B2) C-334 WHT BLK (2.2,E5)(2.2,E5)C-335 WHT BLK (2.2,E5)C-335 WHT BLK (2.2,B4)(2.2,B4) C-335 WHT BLK (2.2,B4) C-335 WHT BLK (2.2,E1)(2.2,E1)C-336 WHT BLK (2.2,E1)C-336 WHT BLK (2.2,B2)(2.2,B2) C-336 WHT BLK (2.2,B2) C-336 WHT BLK (2.2,E2)(2.2,E2)C-337 WHT BLK (2.2,E2)C-337 WHT BLK (2.2,B2)(2.2,B2) C-337 WHT BLK (2.2,B2) C-337 WHT BLK (2.2,E3)(2.2,E3)C-338 WHT BLK (2.2,E3)C-338 WHT BLK (2.2,B2)(2.2,B2) C-338 WHT BLK (2.2,B2) C-338 WHT BLK (2.2,E4)(2.2,E4)C-339 WHT BLK (2.2,E4)C-339 WHT BLK (2.2,B2)(2.2,B2) C-339 WHT BLK (2.2,B2) C-339 WHT BLK (2.2,E4)(2.2,E4)C-340 WHT BLK (2.2,E4)C-340 WHT BLK (2.2,B4)(2.2,B4) C-340 WHT BLK (2.2,B4) C-340 WHT BLK (2.2,E1)(2.2,E1)C-341 WHT BLK (2.2,E1)C-341 WHT BLK (2.2,B3)(2.2,B3) C-341 WHT BLK (2.2,B3) C-341 WHT BLK (2.2,E2)(2.2,E2)C-342 WHT BLK (2.2,E2)C-342 WHT BLK (2.2,B3)(2.2,B3) C-342 WHT BLK (2.2,B3) C-342 WHT BLK (2.2,E3)(2.2,E3)C-343 WHT BLK (2.2,E3)C-343 WHT BLK (2.2,B3)(2.2,B3) C-343 WHT BLK (2.2,B3) C-343 WHT BLK (2.2,E3)(2.2,E3)C-344 WHT BLK (2.2,E3)C-344 WHT BLK (2.2,B3)(2.2,B3) C-344 WHT BLK (2.2,B3) C-344 WHT BLK (2.2,E4)(2.2,E4)C-345 WHT BLK (2.2,E4)C-345 WHT BLK (2.2,B4)(2.2,B4) C-345 WHT BLK (2.2,B4) C-345 WHT BLK (2.2,E1)(2.2,E1)C-346 WHT BLK (2.2,E1)C-346 WHT BLK (2.2,B3)(2.2,B3) C-346 WHT BLK (2.2,B3) C-346 WHT BLK (2.2,E2)(2.2,E2)C-347 WHT BLK (2.2,E2)C-347 WHT BLK (2.2,B3)(2.2,B3) C-347 WHT BLK (2.2,B3) C-347 WHT BLK (2.2,E3)(2.2,E3)C-348 WHT BLK (2.2,E3)C-348 WHT BLK (2.2,B3)(2.2,B3) C-348 WHT BLK (2.2,B3) C-348 WHT BLK (2.2,E4)(2.2,E4)C-349 WHT BLK (2.2,E4)C-349 WHT BLK (2.2,B4)(2.2,B4) C-349 WHT BLK (2.2,B4) C-349 WHT BLK (2.2,E5)(2.2,E5)C-350 WHT BLK (2.2,E5)C-350 WHT BLK (2.2,B5)(2.2,B5) C-350 WHT BLK (2.2,B5) C-350 Note: BACnet MSTP Add = 2 Wht/Yel 2 4V 1 20 V C O M C N O N C CR - 11 Wht/Bl k Wht/Bl u Blu Yel O rg R IB WHT BLK (2.10,F2) CHW Pump S/S (2.10,F2) CHW Pump S/S C-19 WHT BLK (2.10,F2) CHW Pump S/S C-19 WHT BLK (2.10,A3)CHW PumpAlm(2.10,A3)CHW PumpAlmC-12 WHT BLK (2.10,A3)CHW PumpAlmC-12 Tag Part Number Product Description Manufacturer Quantity CR-11 RIB2401C Encl. Relay, 10A,SPDT,24/120 VAC Coils Functional Devices 1 G-1 F721 Flexus F721 Energy Meter, RTDs, Flow Xmtr, BACNet MSTP Flexim 1 Bill of Material w/ Tags See Drawing No. 2.1 for flow meter location P1+ P1- CHW Flow: 4-20 mA W HT BLK (2.13,A3) Common Primary CHW Flow (2.13,A3) Common Primary CHW Flow C-141 W HT BLK (2.13,A3) Common Primary CHW Flow C-141 DL DL DL DL DL1/18/2019 2/7/2019 2/13/2019 3/7/2019 8/26/2019Added CHW & CW Filter Pump Control Sequence revs per engineeers comments Panel Shop Revisions Update - Added Tower Valve Relay Panel Submittal0 1 2 3 4 5 As-Built 9/9/2020 DL 6 CO#6 10/30/2020 DL 7 As-Built 11/16/2021 DL DRAWING NAME: Condenser Water Flow Diagram PROJECT: NYPA OGS Harriman Campus Central Plant State Campus Road Albany, NY 12203 CONTRACT NO: CT-11-18-0343-P REV DESCRIPTION DATE BY FILENAME: 02 CHW System DE: DL Condenser Water Flow Diagram SE:ST/CH23 Village Lane Wallingford, CT 06492 A B C D E F G H 1 2 3 4 5 1 2 3 4 5 PR: 16" 16"16"16" 16"16"16"16" 18" 36" 36" 18" 18" 18" 16" 16" 12" 12" 12" 12" 16" DRAWING NO.: 2.3 PC-5 PC-4 PC-3 PC-2 PC-1VFD VFD VFD VFD VFD Existing Condenser Water Filtration 1. Optimal flow meter installation locations to be determined on site based on field conditions. Cell 5Cell 5 Cell 4Cell 4 Cell 3Cell 3 Cell 2Cell 2 Cell 1Cell 1 VFDVFDVFDVFDVFD M U M U D M U M U M U Roof ...--.-. -..--|-.: ::: |-||--. WCH-5 3000 Tons ...--.-. -..--|-.: ::: |-||--. WCH-5 3000 Tons ...--.-. -..--|-.: ::: |-||--. Ex. Chiller No.3 1000 Tons ...--.-. -..--|-.: ::: |-||--. Ex. Chiller No.3 1000 Tons ...--.-. -..--|-.: ::: |-||--. WCH-1 2000 Tons ...--.-. -..--|-.: ::: |-||--. WCH-1 2000 Tons ...--.-. -..--|-.: ::: |-||--. WCH-6 3000 Tons ...--.-. -..--|-.: ::: |-||--. WCH-6 3000 Tons ...--.-. -..--|-.: ::: |-||--. WCH-4 2000 Tons ...--.-. -..--|-.: ::: |-||--. WCH-4 2000 Tons ...--.-. -..--|-.: ::: |-||--. Ex. Chiller No. 2 1000 Tons ...--.-. -..--|-.: ::: |-||--. Ex. Chiller No. 2 1000 Tons 2- Po s 2- Po s 2- Po s 2- Po s V-WCH-5-CWS V-ECH-3-CWS V-WCH-1-CWS V-ECH-2-CWS V-WCH-4-CWSV-WCH-6-CWS M O D M O D V-WCH-5-CWR V-WCH-1-CWR V-WCH-4-CWRV-WCH-6-CWR S ig + C om - V-CT-5-CWR V-CT-5-CWS V-CT-4-CWR V-CT-4-CWS V-CT-3-CWR V-CT-3-CWS V-CT-2-CW-BYPASS V-CT-2-CWS V-CT-1-CW-BYPASS V-CT-1-CWS FT -2 FT -2 FT -4 FT -4 FT -8 FT -8 FT -6 FT -6 16" 18" 36" 36" 36" 36"30"24" 2- Po s M O D 2-Po s M O D M O D M O D M O D M O D M O D M O D M O D M O D M O D M O D M O D M O D M O D 16" 16" Max. CWS Flow = 6000 GPM Max. CWS Flow = 6000 GPMMax. CWS Flow = 9000 GPM Max. CWS Flow = 9000 GPM 7500 GPM 7500 GPM 7500 GPM 7500 GPM 7500 GPM C NC NO C NC NO T TTE -1 1 T TTE -1 2 T TTE -1 3 T TTE -1 4 T TTE -1 5 T TTE -1 6 TT TE-17 T TTE -1 8 T TTE -1 9T TTE -2 0T TTE -2 1T TTE -2 2T TTE -2 3 WHT BLK (2.11,A1) WCH-1 CWR Temp (2.11,A1) WCH-1 CWR Temp C-46WHT BLK (2.11,A1) WCH-1 CWR Temp C-46 WHT BLK (2.10,A1) CH-2 CWR Temp (2.10,A1) CH-2 CWR Temp C-2WHT BLK (2.10,A1) CH-2 CWR Temp C-2 WHT BLK (2.10,A3) CH-3 CWR Temp (2.10,A3) CH-3 CWR Temp C-22WHT BLK (2.10,A3) CH-3 CWR Temp C-22 WHT BLK (2 .1 9, A 2) C T- 4 B as in T em p(2 .1 9, A 2) C T- 4 B as in T em p C - 2 0 7 WHT BLK (2 .1 9, A 2) C T- 4 B as in T em p C - 2 0 7 WHT BLK (2 .1 9, A 2) C T- 5 B as in T em p(2 .1 9, A 2) C T- 5 B as in T em p C - 2 0 8 WHT BLK (2 .1 9, A 2) C T- 5 B as in T em p C - 2 0 8 WHT BLK (2 .1 9, A 2) C T- 2 B as in T em p(2 .1 9, A 2) C T- 2 B as in T em p C - 2 0 5 WHT BLK (2 .1 9, A 2) C T- 2 B as in T em p C - 2 0 5 WHT BLK (2 .1 9, A 2) C T- 3 B as in T em p(2 .1 9, A 2) C T- 3 B as in T em p C - 2 0 6 WHT BLK (2 .1 9, A 2) C T- 3 B as in T em p C - 2 0 6 WHT BLK (2.19,A2) CT-1 Basin Temp (2.19,A2) CT-1 Basin Temp C-204 WHT BLK (2.19,A2) CT-1 Basin Temp C-204 WHT BLK (2 .1 9, A 1) C om m o n C W S T em p (2 .1 9, A 1) C om m o n C W S T em p C - 2 0 2 WHT BLK (2 .1 9, A 1) C om m o n C W S T em p C - 2 0 2 W H T B LK (2.19,A1) Common CWR Temp (2.19,A1) Common CWR Temp C-201 W H T B LK (2.19,A1) Common CWR Temp C-201 WHT BLK (2.12,A1) WCH-4 CWR Temp (2.12,A1) WCH-4 CWR Temp C-70WHT BLK (2.12,A1) WCH-4 CWR Temp C-70 WHT BLK (2.12,A3) WCH-5 CWR Temp (2.12,A3) WCH-5 CWR Temp C-94WHT BLK (2.12,A3) WCH-5 CWR Temp C-94 WHT BLK (2.13,A1) WCH-6 CWR Temp (2.13,A1) WCH-6 CWR Temp C-118WHT BLK (2.13,A1) WCH-6 CWR Temp C-118 See Drawing No. 2.6 for WCH-1 valve, flow meter and chiller wiring details See Drawing No. 2.5a for WCH-3 valve, flow meter and chiller wiring details See Drawing No. 2.7 for WCH-4 valve, flow meter and chiller wiring details See Drawing No. 2.8 for WCH-5 valve, flow meter and chiller wiring details See Drawing No. 2.9 for WCH-6 valve, flow meter and chiller wiring details See Drawing No. 2.5a for WCH-2 valve, flow meter and chiller wiring details IS-2 C NO W h t/Y e l 24V 120VCOM C NONC CR-2 W h t/B lk W h t/B lu B lu Y el O rg RIB M HAND AUTO OFF L1 L2 MOTOR STARTER M 2 M 1Power by others M HAND AUTO OFF L1 L2 MOTOR STARTER M 2 M 1Power by others CW Filter Pump Wiring Power to filtration pump Tag Part Number Product Description Manufacturer Quantity CR-2 RIBU1C Encl. Relay, 10A,SPDT,24/120 VAC Coils Functional Devices 1 IS-2 H608 Current Switch, Split Core, Adj. Setpoint to 0.5A, Mini Veris 1 PDT-1 2301-050PD-3V-11-B Diff. Press. Transmitter, Wet, 4-20 mA, 0-50 psid Setra 1 TE-11 ALC/10K-2-I-8"-MB Immersion 8" Insertion, J-Box, w/Brass Thermowell BAPI 1 TE-12 ALC/10K-2-I-8"-MB Immersion 8" Insertion, J-Box, w/Brass Thermowell BAPI 1 TE-13 ALC/10K-2-I-8"-MB Immersion 8" Insertion, J-Box, w/Brass Thermowell BAPI 1 TE-14 ALC/10K-2-I-8"-MB Immersion 8" Insertion, J-Box, w/Brass Thermowell BAPI 1 TE-15 ALC/10K-2-I-8"-MB Immersion 8" Insertion, J-Box, w/Brass Thermowell BAPI 1 TE-16 ALC/10K-2-I-8"-MB Immersion 8" Insertion, J-Box, w/Brass Thermowell BAPI 1 TE-17 ALC/10K-2-I-8"-MB Immersion 8" Insertion, J-Box, w/Brass Thermowell BAPI 1 TE-18 ALC/10K-2-I-8"-MB Immersion 8" Insertion, J-Box, w/Brass Thermowell BAPI 1 TE-19 ALC/10K-2-I-8"-MB Immersion 8" Insertion, J-Box, w/Brass Thermowell BAPI 1 TE-20 ALC/10K-2-I-8"-MB Immersion 8" Insertion, J-Box, w/Brass Thermowell BAPI 1 TE-21 ALC/10K-2-I-8"-MB Immersion 8" Insertion, J-Box, w/Brass Thermowell BAPI 1 TE-22 ALC/10K-2-I-8"-MB Immersion 8" Insertion, J-Box, w/Brass Thermowell BAPI 1 TE-23 ALC/10K-2-I-8"-MB Immersion 8" Insertion, J-Box, w/Brass Thermowell BAPI 1 Bill of Material w/ Tags W H T B LK (2.13,A4) CW Filter Pump Status (2.13,A4) CW Filter Pump Status C-145 W H T B LK (2.13,A4) CW Filter Pump Status C-145 W H T B LK (2.13,E5) CW Filter Pump S/S (2.13,E5) CW Filter Pump S/S C-147 W H T B LK (2.13,E5) CW Filter Pump S/S C-147 FT-10 FT-10 FT-13 FT-13 WHT BLK (2.13,A3) Primary CW DP (2.13,A3) Primary CW DP C-132 WHT BLK (2.13,A3) Primary CW DP C-132 M O D M O D FT-14 s FT-14 s FT-14rFT-14rFT-15sFT-15sFT-15rFT-15rFT-16sFT-16s FT-16rFT-16r FT-17sFT-17s FT-17rFT-17r FT-18sFT-18s FT -1 8 r FT -1 8 r Note: Level sensor in each tower monitored by ALC. Refer to drawings 2.17 and 2.18 for additional cooling tower details. DL DL DL DL DL1/18/2019 2/7/2019 2/13/2019 3/7/2019 8/26/2019Added CHW & CW Filter Pump Control Sequence revs per engineeers comments Panel Shop Revisions Update - Added Tower Valve Relay Panel Submittal0 1 2 3 4 5 As-Built 9/9/2020 DL 6 CO#6 10/30/2020 DL 7 As-Built 11/16/2021 DL DRAWING NAME: Condenser Water Pump PROJECT: NYPA OGS Harriman Campus Central Plant State Campus Road Albany, NY 12203 CONTRACT NO: CT-11-18-0343-P REV DESCRIPTION DATE BY FILENAME: 02 CHW System DE: DL Condenser Water Pump SE:ST/CH23 Village Lane Wallingford, CT 06492 A B C D E F G H 1 2 3 4 5 1 2 3 4 5 PR: DRAWING NO.: 2.4 33+ 34- IPS 4003 Terminal Block Condenser Water Pump Controller Wiring Condenser Water Pump Wiring 24 VDC DI Signal 35+ 36- 24 VDC DI Signal 37+ 38- 24 VDC DI Signal 39+ 40- 24 VDC DI Signal 41+ 42- 24 VDC DI Signal 43+ 44- 24 VDC DI Signal 45+ 46- 24 VDC DI Signal 47+ 48- 24 VDC DI Signal 49+ 50- 24 VDC DI Signal S/S Speed Run Status Fault Auto Bypass RS-485 BAS Remote Start/Stop Pump 1 VFD Fault Pump 2 VFD Fault Pump 3 VFD Fault Pump 4 VFD Fault Pump 1 VFD Run Feedback Pump 2 VFD Run Feedback Pump 3 VFD Run Feedback Pump 4 VFD Run Feedback 53+ 54- AO Signal 0V Pump 1 VFD Speed Reference (0-10 VDC) 55+ 56- AO Signal 0V 57+ 58- AO Signal 0V 59+ 60- AO Signal 0V Pump 2 VFD Speed Reference (0-10 VDC) Pump 3 VFD Speed Reference (0-10 VDC) Pump 4 VFD Speed Reference (0-10 VDC) G G 61+ 62- NO Com Pump 1 VFD Start Signal 63+ 64- NO Com Pump 2 VFD Start Signal 65+ 66- NO Com Pump 3 VFD Start Signal 67+ 68- NO Com Pump 4 VFD Start Signal 73+ 74- NO Com General System Alarm (Dry Contact) 75+ 76- NO Com Pump 1 VFD Auto Bypass 77+ 78- NO Com 79+ 80- NO Com 81+ 82- NO Com Pump 2 VFD Auto Bypass Pump 3 VFD Auto Bypass Pump 4 VFD Auto Bypass 93 91 92 Rx+/Tx+ Ground BAS Serial Interface Rx-/Tx- 96- 94 95+Rx+/Tx+ Ground Pump Serial I nterface Rx-/Tx- BACnet MSTP Com. Bus IN and OUT As per Riser Diagram Wht Blk Wht Blk Wht Blk Wht Blk Wht Blk Wht Blk Wht Blk Wht Blk Wht Blk Modbus Com. Bus in from Pump Controller, Out to Pump 2 VFD Modbus Com. Bus out to Pump 1 VFD 135+ 136- 24 VDC DI Signal Pump 5 VFD Fault 153+ 154- AO Signal 0V Pump 5 VFD Speed Reference (0-10 VDC) G 161+ 162- NO Com Pump 5 VFD Start Signal 175+ 176- NO Com Pump 5 VFD Auto Bypass PC-1 Terminal Strip S/S Speed Run Status Fault Auto Bypass RS-485 Wht Blk Wht Blk Wht Blk Modbus Com. Bus in from Pump 1 VFD, Out to Pump 3 VFD PC-2 Terminal Strip S/S Speed Run Status Fault Auto Bypass RS-485 Wht Blk Wht Blk Wht Blk Modbus Com. Bus in from Pump 2 VFD, Out to Pump 4 VFD PC-3 Terminal Strip S/S Speed Run Status Fault Auto Bypass RS-485 Wht Blk Wht Blk Wht Blk Modbus Com. Bus in from Pump 3 VFD, Out to Pump 5 VFD PC-4 Terminal Strip S/S Speed Run Status Fault Auto Bypass RS-485 PC-5 Terminal Strip WHT BLK (2.4,E1)(2.4,E1)C-301 WHT BLK (2.4,E1)C-301 WHT BLK (2.4,B1)(2.4,B1) C-301 WHT BLK (2.4,B1) C-301 WHT BLK (2.4,E2)(2.4,E2)C-302 WHT BLK (2.4,E2)C-302 WHT BLK (2.4,B1)(2.4,B1) C-302 WHT BLK (2.4,B1) C-302 WHT BLK (2.4,E3)(2.4,E3)C-303 WHT BLK (2.4,E3)C-303 WHT BLK (2.4,B1)(2.4,B1) C-303 WHT BLK (2.4,B1) C-303 WHT BLK (2.4,E4)(2.4,E4)C-304 WHT BLK (2.4,E4)C-304 WHT BLK (2.4,B1)(2.4,B1) C-304 WHT BLK (2.4,B1) C-304 143+ 144- 24 VDC DI Signal Pump 5 VFD Run Feedback WHT BLK (2.4,E5)(2.4,E5)C-321 WHT BLK (2.4,E5)C-321 WHT BLK (2.4,B4)(2.4,B4) C-321 WHT BLK (2.4,B4) C-321 Wht Blk Wht Blk Wht Blk Modbus Com. Bus in from Pump 4 VFD WHT BLK (2.4,E1)(2.4,E1)C-305 WHT BLK (2.4,E1)C-305 WHT BLK (2.4,B2)(2.4,B2) C-305 WHT BLK (2.4,B2) C-305 WHT BLK (2.4,E2)(2.4,E2)C-306 WHT BLK (2.4,E2)C-306 WHT BLK (2.4,B2)(2.4,B2) C-306 WHT BLK (2.4,B2) C-306 WHT BLK (2.4,E3)(2.4,E3)C-307 WHT BLK (2.4,E3)C-307 WHT BLK (2.4,B2)(2.4,B2) C-307 WHT BLK (2.4,B2) C-307 WHT BLK (2.4,E4)(2.4,E4)C-308 WHT BLK (2.4,E4)C-308 WHT BLK (2.4,B2)(2.4,B2) C-308 WHT BLK (2.4,B2) C-308 WHT BLK (2.4,E5)(2.4,E5)C-322 WHT BLK (2.4,E5)C-322 WHT BLK (2.4,B4)(2.4,B4) C-322 WHT BLK (2.4,B4) C-322 WHT BLK (2.4,E1)(2.4,E1)C-309 WHT BLK (2.4,E1)C-309 WHT BLK (2.4,B2)(2.4,B2) C-309 WHT BLK (2.4,B2) C-309 WHT BLK (2.4,E2)(2.4,E2)C-310 WHT BLK (2.4,E2)C-310 WHT BLK (2.4,B2)(2.4,B2) C-310 WHT BLK (2.4,B2) C-310 WHT BLK (2.4,E3)(2.4,E3)C-311 WHT BLK (2.4,E3)C-311 WHT BLK (2.4,B2)(2.4,B2) C-311 WHT BLK (2.4,B2) C-311 WHT BLK (2.4,E4)(2.4,E4)C-312 WHT BLK (2.4,E4)C-312 WHT BLK (2.4,B2)(2.4,B2) C-312 WHT BLK (2.4,B2) C-312 WHT BLK (2.4,E4)(2.4,E4)C-323 WHT BLK (2.4,E4)C-323 WHT BLK (2.4,B4)(2.4,B4) C-323 WHT BLK (2.4,B4) C-323 WHT BLK (2.4,E1)(2.4,E1)C-313 WHT BLK (2.4,E1)C-313 WHT BLK (2.4,B3)(2.4,B3) C-313 WHT BLK (2.4,B3) C-313 WHT BLK (2.4,E2)(2.4,E2)C-314 WHT BLK (2.4,E2)C-314 WHT BLK (2.4,B3)(2.4,B3) C-314 WHT BLK (2.4,B3) C-314 WHT BLK (2.4,E3)(2.4,E3)C-315 WHT BLK (2.4,E3)C-315 WHT BLK (2.4,B3)(2.4,B3) C-315 WHT BLK (2.4,B3) C-315 WHT BLK (2.4,E3)(2.4,E3)C-316 WHT BLK (2.4,E3)C-316 WHT BLK (2.4,B3)(2.4,B3) C-316 WHT BLK (2.4,B3) C-316 WHT BLK (2.4,E4)(2.4,E4)C-324 WHT BLK (2.4,E4)C-324 WHT BLK (2.4,B4)(2.4,B4) C-324 WHT BLK (2.4,B4) C-324 WHT BLK (2.4,E1)(2.4,E1)C-317 WHT BLK (2.4,E1)C-317 WHT BLK (2.4,B3)(2.4,B3) C-317 WHT BLK (2.4,B3) C-317 WHT BLK (2.4,E2)(2.4,E2)C-318 WHT BLK (2.4,E2)C-318 WHT BLK (2.4,B3)(2.4,B3) C-318 WHT BLK (2.4,B3) C-318 WHT BLK (2.4,E3)(2.4,E3)C-319 WHT BLK (2.4,E3)C-319 WHT BLK (2.4,B3)(2.4,B3) C-319 WHT BLK (2.4,B3) C-319 WHT BLK (2.4,E4)(2.4,E4)C-320 WHT BLK (2.4,E4)C-320 WHT BLK (2.4,B4)(2.4,B4) C-320 WHT BLK (2.4,B4) C-320 WHT BLK (2.4,E5)(2.4,E5)C-325 WHT BLK (2.4,E5)C-325 WHT BLK (2.4,B5)(2.4,B5) C-325 WHT BLK (2.4,B5) C-325 Note: BACnet MSTP Add = 1 Wht/Yel 2 4V 1 20 V C O M C N O N C CR -1 Wht/Bl k Wht/Bl u Blu Yel O rg R IB Tag Part Number Product Description Manufacturer Quantity CR-1 RIB2401C Encl. Relay, 10A,SPDT,24/120 VAC Coils Functional Devices 1 Bill of Material w/ Tags WHT BLK (2.10,F4) CWP S/S (2.10,F4) CWP S/S C-43 WHT BLK (2.10,F4) CWP S/S C-43 WHT BLK (2.10,A4)CW Pump Alarm(2.10,A4)CW Pump AlarmC-32 WHT BLK (2.10,A4)CW Pump AlarmC-32

163 W 125th St #215, New York, NY 10027, United StatesLocation

Address: 163 W 125th St #215, New York, NY 10027, United States

Country : United StatesState : New York

You may also like

HVAC/R Maintenance Statewide

Due: 09 May, 2024 (in 20 days)Agency: Massachusetts Department of Transportation

Fuel Oil - Statewide (dyed diesel, heating, kerosene)

Due: 30 Jun, 2025 (in 14 months)Agency: ADMINISTRATION, DEPT OF

FUEL OILS

Due: 29 Sep, 2024 (in 5 months)Agency: STATE, DEPARTMENT OF

Please Sign In to see more like these.

Don't have an account yet? Create a free account now.